Schneider LUCM12BL is a multifunction motor control unit of the TeSys Ultra series, 정격 전류가 3~12A인 단상/3상 모터용으로 특별히 설계되었습니다.. 포괄적인 보호 기능을 제공합니다., 진단 및 통신 기능. TeSys Ultra의 클래식 모델로서, 그 핵심가치는 일체형 모터 스타터의 통합 제어 능력에 있습니다.. When matched with the LUB series power base, it realizes motor protection, control and status monitoring. This model is discontinued and now only supplied as a spare part. For selection, priority shall be given to upgraded models in the same series (예를 들어. LUCD12BL) to balance performance improvement and system compatibility.
- 모델 세그먼트 정의 (Precise Decoding)
| 분절 | 암호 | 설명 | 주요 특징 |
| Product Family ID | LUC | Schneider TeSys Ultra series control unit (L=TeSys series, U=Ultra, C=Control) | Compatible with TeSys Ultra all-in-one motor starter system |
| 기능 유형 | 중 | Multifunction type | Equipped with LCD display and 4-key keypad, supports advanced diagnosis and parameter setting |
| 현재 범위 | 12 | Suitable for motor rated current 3–12A (Ir adjustable) | Compatible with 5.5kW(400다섯)/9kW(690다섯) three-phase motors and 2.2kW(400다섯) single-phase motors |
| 제어 전압 | BL | 24V DC control coil (B=24V, L=DC) | Control circuit requires external 24V DC power supply; 대략적인 전력 소비. 5여 |
- Core Specification Table (High-Density Technical Parameters)
| 매개변수 카테고리 | 상세사양 | 비고 |
| Core Performance | • Rated current range: 3–12A (Ir continuously adjustable) | Supports single/three-phase motors, covering most small and medium motor application scenarios |
| • Overload class: Class 5–30 optional | ||
| • Short-circuit protection: 13×Irmax (동시에 일어나는) | ||
| • Overcurrent protection: 14.2×Ir (시간 지연) | ||
| • Motor compatibility: 5.5kW(400다섯)/9kW(690다섯) 삼상, 2.2kW(400다섯) 단상 | ||
| 전원공급장치 | • Control circuit: 24DC에서, 대략. 5W power consumption | Independent power supply for control unit and power base improves system reliability |
| • Operating voltage: AC 200–690V, 50/60헤르츠 | ||
| • Power base connection: controlled via A1/A2 terminals | ||
| 물리적 특성 | • 크기: 60mm×45mm×60mm (Depth×Width×Height) | Compact design saves cabinet space and fits standard industrial installation environments |
| • 무게: 0.175kg (net) / 0.210kg (gross) | ||
| • 장착: 표준 35mm DIN 레일 | ||
| • Protection class: IP20 (cabinet installation) | ||
| Environmental Ratings | • 작동 온도: -25°C ~ +70°C | Meets industrial reliability requirements, IEC를 준수 60947-6-2 |
| • 보관 온도: -40°C ~ +85°C | ||
| • Humidity: 5%–95% (비응축) | ||
| • Vibration resistance: 10-150Hz, 0.5mm double amplitude | ||
| • Shock resistance: 15g (11ms) | ||
| 보호 기능 | • Overload / 단락 보호 (thermal-magnetic) | Supports manual / 자동 재설정; records the last 5 trip events for fault analysis |
| • Phase loss / phase unbalance protection | ||
| • Insulation fault protection (equipment side) | ||
| • No-load / underload operation protection | ||
| • Stall / long start protection | ||
| • Differentiated diagnosis of thermal overload and magnetic faults | ||
| Interface Capabilities | • Control input: 2 configurable digital inputs | Supports remote monitoring and parameter configuration; integrable into SCADA/PLC systems |
| • Status output: 2 릴레이 출력 (NO+NC) | ||
| • Communication: RS485 Modbus RTU, RJ45 port | ||
| • Display: LCD screen + 4-key keypad (real-time display of current, 전압, 힘, 등.) | ||
| 제품 수명주기 | • Status: 더 이상 사용되지 않음 / 단종 | Supplied only as spare parts; upgrade replacement is recommended |
| • Recommended replacement: LUCD12BL (enhanced digital display version) | ||
| • Discontinued around 2020 | ||
| 인증 & 규정 준수 | • Green Premium (RoHS/REACh) | Compliant with global industrial safety and environmental regulations |
| • IEC 60947-6-2 기준 | ||
| • CE certification |
- 액세서리 목록 (Complete Supporting Parts)
| Accessory Type | 추천 모델 | 기능 설명 | 호환성 |
| Power Base | LUB12 / LUB32 / LUB38 / LUB120 | Provides main circuit connection and short-circuit protection; snap-on connection with control unit | 완벽하게 호환됨, must be used together |
| Connection Cable | Schneider dedicated connection cable | Internal connection between control unit and power base to ensure signal transmission | Original accessory ensuring communication stability |
| 마운팅 레일 | 표준 DIN 35mm 레일 | For cabinet installation and fixing, ensuring heat dissipation and shock resistance | Universal industrial standard, compatible with all TeSys Ultra products |
| Power Adapter | Schneider 24V DC industrial power supply | Provides stable power for the control unit to ensure reliable system operation | Original power supply recommended to avoid voltage fluctuation impact |
| 통신 모듈 | Optional Modbus RTU module | Expands communication function for connection with PLC or SCADA | 플러그 앤 플레이, no additional programming required |
| 구성 소프트웨어 | TeSys Ultra Configuration Tool | For parameter setting, fault diagnosis and data logging | Free download, supports offline / online configuration |
| Function Expansion Module | LUFDA (alarm indication) / LULC (원격 제어) | Extends local alarm indication or remote control functions | Direct snap-on mounting, 추가 배선 없음 |
- Competitor & 브랜드 간 참조 (Selection Guidance)
4.1 Schneider Internal Upgrade Replacement Models (Recommended Priority)
| 교체 모델 | 핵심 차이점 | 성능 업그레이드 | Compatibility Description |
| LUCD12BL | Enhanced digital display version with more diagnosis functions | Higher display accuracy; supports trend recording and fault analysis | 직접 교체, no system modification required, fully function compatible |
| LUCA12BL | Standard version with fixed Class 10 초과 적재 | Lower cost for basic protection needs | Direct replacement with slightly simplified protection functions |
| LUCL12BL | Standard control unit without display | Lowest cost for simple control scenarios | 완벽하게 호환됨, only without LCD and keypad operation |
| LUCM18BL | Current range 3–18A for higher power motors | Extended current range for 7.5kW(400다섯) 모터 | Requires LUB18 series power base; suitable for capacity expansion |
4.2 Cross-Brand Replacement Solutions (System Adaptation Required)
| 상표 | 모델 | 핵심 매개변수 | Adaptation Description |
| 지멘스 | 3RW5024-1BB14 | Soft starter control unit, 3–12A, 24DC에서 | Control logic reconfiguration required; matches Siemens soft starter base |
| 씨줄 | PSR12-600-70 | Soft starter, 3–12A, 모드버스 통신 | 모드버스 지원; parameter adjustment needed for motor protection matching |
| 이튼 | DS7-12 | Motor protection controller, 3–12A, 24DC에서 | Base and interface replacement required; protection performance equivalent to LUCM12BL |
| 뮐러 | DILM12-10+Z012 | 접촉기 + thermal overload relay combination, 3–12A | 기본 보호만; no communication or diagnosis functions; lowest cost |
- 선택 지침 & Replacement Strategy (Mnemonic Rules + 운영안내)
5.1 Selection Mnemonic
Three Principles for TeSys Ultra Selection:
Check Current: 3–12A choose 12 시리즈; 12–18A choose 18 시리즈; match motor power accordingly (5.5kW/400V corresponds to 12A)
Check Function: Basic protection choose LUCA/LUCL; advanced diagnosis choose LUCM/LUCD (with LCD)
Check Supply Voltage: 24V DC = suffix BL; 110V AC = suffix FU; 230V AC = suffix FE
5.2 Replacement Priority for Fault Replacement
- Same Model Spare Replacement: LUCM12BL (simplest, plug-and-play without configuration)
- Same-Series Upgrade: LUCD12BL (enhanced digital version, 업그레이드된 기능으로 직접 교체)
- Function Downgrade Replacement: LUCA12BL (표준 버전, lower cost for budget-limited scenarios)
- New Platform Replacement: TeSys Island series (IoT-enabled, hardware adaptation required for system upgrade)
5.3 애플리케이션 노트
호환성: Only applicable to TeSys Ultra series; must be used with LUB power base, incompatible with TeSys Classic series
설치: Snap-on connection between control unit and power base; cut off power before installation and ensure correct wiring of A1/A2 terminals
매개변수 설정: Configure via LCD keypad or TeSys Ultra Configuration Tool; parameter backup recommended
유지: Regularly check heat dissipation and dust cleaning; record trip events for fault analysis
Upgrade Matters: When replacing with higher-version control units, synchronously update parameters to ensure normal protection functions
수명주기 관리: As a discontinued product, stock up on key spare parts or upgrade entirely to TeSys Island platform (supports remote monitoring and predictive maintenance)
Schneider LUCM12BL is a classic multifunction control unit in the TeSys Ultra series. Featuring compact design, 완전한 보호, advanced diagnosis and Modbus communication, it is widely applied in small and medium motor control fields. Though discontinued, it remains valuable as spare parts for legacy equipment maintenance. Follow the priority: Current Matching → Function Requirement → Supply Voltage → Lifecycle. For obsolete models, prioritize same-series upgraded replacement such as LUCD12BL to ensure system stability and easy maintenance.
Selected Application Cases of Schneider LUCM12BL (5 Major Industry Scenarios)
As a multifunction motor control unit of the TeSys Ultra series, Schneider LUCM12BL features 3–12A current adaptation, full protection functions, LCD diagnostic display and Modbus communication capability. It realizes reliable motor control and intelligent monitoring across multiple industrial sectors. Below are 5 typical application cases covering process industry, manufacturing and infrastructure, highlighting its advantages in fault prevention, maintenance efficiency improvement and system integration.
- Wastewater Treatment Plant – Submersible Pump Motor Protection & Remote Monitoring
Application Background
An urban wastewater treatment plant is equipped with 20 sets of 5.5kW submersible pumps (400다섯, rated current 11A) for sewage lifting and aeration systems. The traditional contactor + thermal overload relay solution had limited protection functions, difficult fault location and no remote monitoring, resulting in high equipment failure rate (3–5 times/month), high maintenance cost and unstable treatment efficiency.
해결책
Adopt LUCM12BL + LUB12 power base to replace the original protection device with the following configuration:
과부하 보호: 수업 10 (adapted to heavy starting characteristics of submersible pumps)
위상 손실 / phase unbalance protection: Prevent motor burnout caused by phase loss
Insulation fault protection: Monitor winding insulation status of submersible pumps to prevent electric leakage
모드버스 통신: Connect to PLC via RS485 for remote start/stop and parameter monitoring
오류 기록: Store the last 5 trip events for rapid diagnosis
Implementation Effect
| 지시자 | Before Improvement | After Improvement | Improvement Range |
| Equipment Failure Rate | 3–5 times/month | 0–1 time/month | Reduced over 80% |
| Fault Troubleshooting Time | 2–4 hours/time | 15–30 minutes/time | Reduced over 75% |
| Annual Maintenance Cost | 120,000 위안화 | 35,000 위안화 | Reduced over 70% |
| System Availability | 88% | 99.50% | Increased by 11.5% |
Key Value
예측 유지 관리: Early detection of winding aging via insulation monitoring to avoid sudden failure
Remote Management: Central control room real-time monitoring of pump current, 전압, power and optimization of operation strategy
Data-Driven Decision: Optimize maintenance schedule and extend equipment service life based on fault record analysis
- Automotive Parts Factory – Intelligent Control of Conveyor Line Motors
Application Background
The stamping workshop of an auto parts factory has 15 automatic conveyor lines, each equipped with 3–5 sets of 2.2–5.5kW three-phase motors (400다섯, rated current 4–11A) for workpiece handling and positioning. Traditional magnetic starters had low protection accuracy, unable to distinguish fault types and lack of status monitoring, causing frequent production line shutdowns (6–8 times/month) and affecting production rhythm.
해결책
Equip each conveyor motor with LUCM12BL + LUB32 power base and connect to the workshop SCADA system via Modbus RTU:
Adjustable overload class (Class 5–30): Adapt to conveyor motors with different load characteristics
Stall / long start protection: Prevent motor burnout caused by workpiece jamming
No-load operation protection: Timely detect abnormal conditions such as conveyor chain breakage
Real-time status display: LCD directly shows current, voltage and power for on-site inspection
Remote diagnosis: SCADA centrally displays all motor operating status for fast fault location
Implementation Effect
Monthly production line downtime reduced from 48 hours to 8 시간; production efficiency increased by 25%
Motor replacement frequency reduced from 3–4 units per quarter to 1 unit every six months; spare parts cost reduced by 60%
Maintenance response time shortened from 30 분까지 10 분; O&M efficiency increased by 67%
Energy saving optimized by monitoring no-load operation and adjusting conveyor start-stop strategy timely; power saving by 12%
Innovative Application
Utilize LUCM12BL’s differentiated diagnosis of thermal overload and magnetic faults to build a motor fault knowledge base, enabling automatic fault identification and maintenance recommendation, transforming traditional breakdown maintenance into preventive maintenance + precise maintenance.
- 음식 & Beverage Factory – Motor Protection for Stirring & Mixing Equipment
Application Background
The fermentation workshop of a large dairy plant has 10 sets of 5.5kW stirring motors (400다섯, rated current 11A) for yogurt and cheese fermentation. The original simple protection scheme had protection blind spots such as phase unbalance and insulation faults, and no fault process recording, resulting in batch product scrapping and severe economic losses due to motor failures.
해결책
Adopt LUCM12BL + LUB38 power base with customized configuration for food processing environment:
과부하 보호: 수업 20 (adapted to high inertia load during stirring equipment startup)
Phase unbalance protection: Threshold set at 15% to prevent motor overheating due to phase loss
Insulation fault protection: Monitor equipment-side insulation resistance to prevent electric leakage in humid environment
Automatic reset: Auto reset for short-term overload faults to avoid manual intervention and ensure continuous production
Data recording: Store current and voltage data 10 seconds before trip for fault analysis
Implementation Effect
Product scrapping rate reduced from 2–3 batches/month to zero; annual economic loss avoided over 500,000 위안화
Equipment reliability raised to 99.8%, meeting strict continuous production requirements of food industry
Maintenance efficiency improved: Hidden faults such as agitator blade wear and bearing damage quickly located via fault data
Compliance upgraded: Meets HACCP certification requirements and realizes full traceability of key equipment
Industry Adaptation Points
Select IP20 control unit with sealed cabinet design for humid and corrosive food processing environment
Realize MES system docking via Modbus communication to record equipment operation data and meet production traceability requirements
- Pharmaceutical Factory – Fan & Water Pump Control for HVAC System
Application Background
The HVAC system in the clean workshop of a biopharmaceutical factory includes 8 sets of 3.7–5.5kW fans and 6 sets of 5.5kW water pumps (400다섯, rated current 8–11A) to maintain constant temperature, humidity and air cleanliness. The original decentralized control had low control accuracy, high energy consumption and difficult maintenance, failing to meet strict GMP environmental parameter requirements.
해결책
Adopt LUCM12BL + LUB120 advanced power base to build a centralized motor control and monitoring system:
Fan control: 수업 10 overload protection with variable frequency linkage via air volume sensors
Water pump control: 수업 15 overload protection with constant pressure water supply via pressure sensors
통신 통합: Connect to Building Automation System (바스) via Modbus RTU for centralized HVAC management
Status monitoring: LCD real-time display of motor parameters with on-site parameter adjustment and fault diagnosis
Alarm linkage: Automatic sound-light alarm upon motor fault and maintenance notification via BAS
Implementation Effect
Environmental parameter stability improved: Temperature fluctuation reduced from ±1.5°C to ±0.5°C; humidity fluctuation from ±5%RH to ±2%RH, fully meeting GMP standards
Energy consumption reduced: 위에 20% power saving for fan and water pump system via frequency conversion linkage and no-load monitoring
Maintenance efficiency improved: Remote diagnosis shortens fault troubleshooting from 2 hours to 30 분
System integration upgraded: Seamless connection between HVAC and production management system improves overall automation level
Key Technical Highlights
Upgrade traditional motor control to intelligent nodes via LUCM12BL’s multi-protection and communication capability, laying a foundation for digital transformation of pharmaceutical plants
Batch parameter configuration and backup supported by TeSys Ultra Configuration Tool improves system commissioning efficiency
- Mining Machinery – Motor Protection for Belt Conveyors
Application Background
The raw coal conveying system of an open-pit coal mine has 12 sets of 5.5kW belt conveyor motors (690다섯, rated current 6A) for short-distance raw coal transportation. Harsh mining environment (고온, 먼지, 진동) caused traditional protection devices to have poor anti-interference, frequent failures and high maintenance costs, affecting coal conveying efficiency.
해결책
Adopt LUCM12BL + LUB380 advanced power base with enhanced configuration for mining conditions:
과부하 보호: 수업 30 (adapted to heavy start and frequent start-stop of belt conveyors)
Stall protection: Threshold set at 200%Ir to prevent motor stall caused by raw coal accumulation
Anti-vibration design: Special mounting bracket improves stability under vibration conditions
Wide temperature adaptability: Operating range -25°C ~ +70°C adapts to extreme mine temperatures
오류 기록: Store last 5 trip events for analyzing causes such as belt slippage and raw coal overload
Implementation Effect
Equipment failure rate reduced from 4–6 times/month to 0–1 time/month; conveying efficiency increased by 15%
Maintenance cost reduced: Spare parts consumption down 60% and manual maintenance cost down 50%
Reliability enhanced: Stable operation under high temperature, dust and vibration with MTBF over 8000 시간
Safety improved: Insulation and phase loss protection effectively prevent motor electric leakage and burnout, ensuring personnel safety
Environmental Adaptation Points
Install control unit in sealed cabinet with dust-proof fan to avoid dust ingress affecting operation
Use shielded communication cable to improve Modbus communication reliability under strong electromagnetic interference in mines
- Application Case Summary & 선택 포인트
6.1 Summary of Core Application Scenarios
| 산업 | Typical Equipment | 적용 가능한 전력 | Core Protection Requirements | LUCM12BL Advantages |
| 수처리 | Submersible pump, aeration pump | 3.7–5.5kW | Insulation fault, 위상 손실, 초과 적재 | 원격 모니터링, 오류 기록, predictive maintenance |
| 조작 | Conveyor line, machine tool | 2.2–5.5kW | Stall, 무부하, phase unbalance | Intelligent diagnosis, fast fault location |
| 음식 & 음료 | Stirrer, mixer | 3.7–5.5kW | 초과 적재, phase unbalance, insulation fault | Data recording, compliance traceability |
| 제약 | HVAC fan, water pump | 3.7–5.5kW | 초과 적재, 무부하, precise control | 시스템 통합, 에너지 최적화 |
| 채광 | Belt conveyor | 5.5kW(690다섯) | Heavy start, stall, 진동 저항 | Wide temperature adaptability, fault analysis |
6.2 Selection Mnemonic (Application Version)
Three Matching Rules for LUCM12BL Selection:
현재 매칭: 3–12A motors choose 12 시리즈, suitable for 5.5kW(400다섯)/9kW(690다섯) 모터
부하 매칭: Heavy start choose Class 20–30; light load choose Class 5–10
Environment Matching: Severe environment adopt advanced power base (LUB120/LUB320/LUB380) with sealed installation
6.3 Key Implementation Points
- Matching Selection: Must be used with LUB series power base to realize complete protection functions
- 매개변수 구성: Set proper protection parameters via LCD keypad or software according to motor type and load characteristics
- Communication Integration: Connect with PLC/SCADA via Modbus RTU to improve system intelligence
- Maintenance Management: Back up parameters regularly, analyze equipment operation status via fault records and optimize maintenance plans
- 교체 권장사항
Considering LUCM12BL is discontinued, priority is recommended for the following solutions in new projects or system upgrades:
- Same-Series Upgrade: LUCD12BL (enhanced digital display version, fully compatible with stronger diagnosis capability)
- 기능 확장: TeSys Island series (IoT connectivity supporting remote monitoring and predictive maintenance)
- Cross-Series Replacement: TeSys Advanced series (supports higher power motors and more communication protocols)
접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지