Schneider XPSAV11113 안전 릴레이 - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

Schneider XPSAV11113 안전 릴레이 - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

전기 같은/

Schneider XPSAV11113 안전 릴레이

Schneider XPSAV11113 안전 릴레이 (Correction for XPSAX11113) This is a Schneider Preventa XPS AV series emergency stop safety relay, powered by 24VDC, dual-channel input, with 3NO instantaneous + 3NO timed + 3 solid-state auxiliary outputs. It complies with ISO 13849-1 Cat.4/PL eand IEC 61508 실 3, used for machine safety circuit monitoring and emergency stop ...

  • 제품 세부정보

Schneider XPSAV11113 안전 릴레이 (Correction for XPSAX11113)

This is a Schneider Preventa XPS AV series emergency stop safety relay, powered by 24VDC, dual-channel input, with 3NO instantaneous + 3NO timed + 3 solid-state auxiliary outputs. It complies with ISO 13849-1 Cat.4/PL eand IEC 61508 실 3, used for machine safety circuit monitoring and emergency stop control. XPSAX11113 is a likely input error; the correct model is XPSAV11113(suffix P for front cover version).

  1. 모델 분석 (Correct Model: XPSAV11113)
모델 부분의미주요 설명
XPSPlatform codePreventa safety automation platform for machine safety protection
AV시리즈 코드XPS AV series, dedicated for emergency stop & safety switch monitoring, with timer function
11113Function code1=24VDC supply, 1=dual-channel input, 1=auto/monitored reset, 1=0–300s timer, 3=3NO instant + 3NO timed outputs
Optional suffixWith front protective cover, IP rating upgraded to IP40 (basic version IP20)
31114No equivalentUser input “XPSAX11113” is likely a typo; no official model exists
  1. 핵심 기술 사양 (공식 표준)
사양적용규격
제품 유형Dual‑channel emergency stop safety relayIEC 61508, ISO 13849-1
정격전압24VDC (-15% ~ +10%)For industrial control power
Input Channels2 채널 (configurable as 1/2 채널)Monitors single/dual‑channel safety switches / E‑stop buttons
Safety Outputs3NO instantaneous + 3NO timed (0–300s adjustable)Contact rated current: 2.5A@AC-15 230V
Auxiliary Outputs3 solid-state outputs (봄 여름 시즌)For status indication or alarm
Safety LevelCat.4/PL e/SIL 3Highest level of machine safety protection
재설정 모드Auto reset / monitored reset selectableMeets various safety circuit designs
설치35mm DIN 레일W45mm × D114mm × H99mm
유입 방지IP20 (기초적인) / IP40 (P‑version)For cabinet mounting
작동 온도-25°C ~ +70°CIndustrial environment range
Thermal CurrentIth=20ATotal output current limit
  1. 시리즈 모델 목록 (XPS AV Series)
모델공급 전압Input ChannelsOutput Configuration시간제 노동자재설정 모드
XPSAV1111324VDC듀얼3NO instant + 3NO timed + 3봄 여름 시즌0–300sAuto/monitored
XPSAV1111224VDC듀얼3NO instant + 3NC timed + 3봄 여름 시즌0–300sAuto/monitored
XPSAV2111324VAC/DC듀얼3NO instant + 3NO timed + 3봄 여름 시즌0–300sAuto/monitored
XPSAV1121324VDC듀얼3NO instant + 3NO timed + 3봄 여름 시즌0–10sAuto/monitored
XPSAV1112324VDC듀얼3NO instant + 3NO timed + 3봄 여름 시즌0–300s수동
  1. 일반적인 응용 분야 & 선택 참고 사항

-4.1 일반적인 응용 분야

애플리케이션Suitability추천
CNC machine safety circuitsCat.4/PL e meets high safety levels; timer for spindle brakingSeries with E‑stop, safety door switches, two‑hand controls
Automated line emergency stopDual‑channel prevents single‑point failure; timer for coordinated stoppingAuto reset for fast restart
Packaging machinery safetySolid-state outputs for status; timer for process sequencingUsed with safety light curtains, safety mats
Robot workstation safetySIL3 for high‑risk robot areas; dual‑channel monitors fence doorsConnected to robot controller safety inputs
Printing machinery safetyTimer for drum deceleration; protects equipment and operatorsMonitored reset to prevent misuse

-4.2 Key Selection & Usage Rules

요인올바른 선택잘못된 선택의 위험
Safety LevelCat.4/PL e/SIL3 for high‑risk machinesLower levels fail risk assessment
Input ChannelsDual for critical circuits; single for auxiliarySingle channel creates single‑point failure risk
재설정 모드Auto for production; manual for fault confirmationAuto in hazardous zones may cause unexpected start
Timer Requirement0–300s for motors, spindles requiring brakingNo timer may cause impact damage
출력 유형Relay for power; solid-state for signalsSolid-state on high current may burn out
  1. 제품특징 & 장점
  2. High safety level: Cat.4/PL e/SIL3 certified
  3. 유연한 구성: Input channels, reset mode, timer adjustable
  4. Rich outputs: 3NO instant + 3NO timed + 3SS for complex circuits
  5. Diagnostics: LED indicators for power, run, fault
  6. 콤팩트: 45mm width saves cabinet space
  7. Backward compatible: XPSUAT13A3AP is official replacement, same dimensions
  8. 유지 & 문제 해결
  9. 정기점검: Check LEDs and terminal tightness monthly
  10. Function test: Simulate faults quarterly to verify safety response
  11. 문제 해결:

-Frequent alarms: Check safety input devices (비상 정지, door switches)

-No output: Verify supply voltage and output fuses

-Abnormal timer: Recalibrate or replace timing module

  1. Warning: Never bridge safety inputs; this reduces safety level to Cat.0

Schneider XPSAV11113 is a high-performance emergency stop safety relay for machines requiring high safety levels.

If you entered XPSAX11113 intentionally, please provide more details for confirmation. If it was a typo, use XPSAV11113or its replacement XPSUAT13A3APto ensure compliance.

-Complete Guide to Replacement Models for Schneider XPSAV11113

Core Replacement Conclusion:

Schneider has discontinued the XPSAV series. XPSUAT13A3APis the official direct replacement.

Precise alternatives from major international brands are listed below, all meeting Cat.4/PL e/SIL3, 24VDC, dual-channel, timed output.

  1. Official Schneider Replacement (First Choice)
원래 모델공식 교체주요 일치 매개변수교체 노트
XPSAV11113 / XPSAV11113PXPSUAT13A3AP24VDC, dual input, 3NO instant + 3NO timed + 3봄 여름 시즌, Cat.4/PL e/SIL3Officially designated; 완벽하게 호환됨, same dimensions, minor wiring changes

-주요 매개변수 (XPSUAT13A3AP)

-Supply: 24VDC (±15%)

-입력: Dual-channel (switchable to single)

-Outputs: 3NO instant + 3NO timed (0–300s) + 3봄 여름 시즌

-Reset: 자동 / monitored

-인증: ISO 13849-1 Cat.4/PL e, IEC 61508 SIL3, EN ISO 13850

-설치: 35mm DIN 레일, W45 × H99 × D114mm

-교체 노트

  1. 배선: Terminal arrangement differs slightly from XPSAV
  2. Setting: Knob + DIP switches instead of pure DIP
  3. Cover: Basic IP20; P-version IP40
  4. 호환성: Fully compatible with existing safety circuits
  5. Precision International Brand Alternatives
상표시리즈교체 모델주요 일치 매개변수차이점
지멘스3SK3SK1122-1AB4024VDC, 듀얼, 3NO+3NO timed+2SS, Cat.4/PL e/SIL3Timer 0–10s (extension for 300s); 1 fewer SS
씨줄MSRMSR132TP-2424VDC, 듀얼, 3NO+3NO timed+2SS, Cat.4/PL e/SIL31 fewer SS; simpler interface, better price
PilzPNOZ XPNOZ X3 24VDC24VDC, 듀얼, 3NO+1NC+2SS, Cat.4/PL e/SIL3No internal timer (needs PNOZ X4); manual/monitored reset
옴론G9SAG9SA-50124VDC, 듀얼, 3NO+3NO timed+3SS, Cat.4/PL e/SIL3Fixed 1s timer; for applications without long delay
바이드뮐러PROtopPROtop 4.1p 24VDC24VDC, 듀얼, 3NO+3NO timed+3SS, Cat.4/PL e/SIL3Timer 0–100s (special for 300s); modular
피닉스컨택트PSRPSR-SPP-24DC/TS3/3X1/1X224VDC, 듀얼, 3NO+3NO timed+1SS, Cat.4/PL e/SIL32 fewer SS; 확장 가능
  1. 선택 & Implementation Guidelines

-3.1 Selection Principles

요인추천Risk
Safety LevelMust be Cat.4/PL e/SIL3Fails assessment
시간제 노동자0–300s: XPSUAT13A3AP; 0–10s: 3SK1122No/insufficient timer causes mechanical damage
Outputs3NO+3NO+3SS ideal; 2SS acceptable for simpler systemsOverloading solid-state outputs
ResetAuto for production; manual for hazardous areasAuto reset risks unexpected startup
상표Match existing system brandIncompatibility increases commissioning work

-3.2 Replacement Steps

  1. Assess circuit: Confirm inputs, outputs, 짐, timer
  2. Rewire: Follow new model wiring diagram
  3. Set parameters: Reset mode, timer, input mode
  4. 시험: 비상 정지, door switch, timer function
  5. Update docs: Revise drawings and manuals
  6. Performance Comparison
Schneider XPSUAT13A3APSiemens 3SK1122-1AB40ABB MSR132TP-24Pilz PNOZ X3 24VDC
Supply24VDC24VDC24VDC24VDC
Inputs2-채널2-채널2-채널2-채널
Instant Out3아니요3아니요3아니요3아니요
Timed Out3아니요 (0–300s)3아니요 (0–10s)3아니요 (0–100s)없음
Solid State3222
ResetAuto/monitoredAuto/manual/monitoredAuto/manualManual/monitored
수준Cat.4/PL e/SIL3Cat.4/PL e/SIL3Cat.4/PL e/SIL3Cat.4/PL e/SIL3
가격Mid‑highMidMid‑lowMid‑high
Lead Time2–4 weeks3–5 weeks2–3 weeks2–4 weeks
  1. Recommended Scenarios
  2. First choice: Schneider-dominated projects, 로봇, precision machines → XPSUAT13A3AP
  3. 비용 효율적: Budget projects → ABB MSR132TP-24or Siemens 3SK1122-1AB40
  4. Long timer: 대형 모터, spindles → XPSUAT13A3AP
  5. Brand consistency: Match existing Siemens / ABB systems

The best replacement for XPSAV11113is XPSUAT13A3AP.

Alternatives from Siemens, 씨줄, Pilz, 등., all meet Cat.4/PL e/SIL3.

Select based on input/output, timer, reset mode, and brand to avoid safety risks or functional mismatch.

이전:

다음:

답장을 남겨주세요

메시지를 남겨주세요