SICK WFS340N415 Label Sensor - 접촉기,회로 차단기,태양광 인버터,전기 계량기,감지기,인코더,PLC

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

 SICK WFS340N415 Label Sensor - 접촉기,회로 차단기,태양광 인버터,전기 계량기,감지기,인코더,PLC

전기 같은/

SICK WFS340N415 Label Sensor

주문번호: 6043920 애플리케이션: Labeling machines, label dispensers; detecting labels, label gaps, transparent labels, doublelabel prevention. Infrared forktype label photoelectric sensor Model Code Explanation WFS: Fork Sensor series 3: Fork width 3 mm 40: Fork depth 42 mm N: NPN 출력 (sinking) 415: M84pin male connector, front panel keys + dynamic teachin function Core Technical Specifications Item ...

  • 제품 세부정보

주문번호: 6043920

애플리케이션: Labeling machines, label dispensers; detecting labels, label gaps, transparent labels, doublelabel prevention. Infrared forktype label 광전 센서

모델 코드 설명

WFS: Fork Sensor series

3: Fork width 3 mm

40: Fork depth 42 mm

N: NPN 출력 (sinking)

415: M84pin male connector, front panel keys + dynamic teachin function

핵심 기술 사양

매개변수
공급 전압10‑30 VDC, ripple <10%
Quiescent Current20 엄마
산출NPN, 최대. load 100 mA, light‑on / dark‑on selectable
응답 시간≤50 μs, switching frequency 10 kHz
감지 가능한 최소 개체2 mm (상표 / label gap)
광원적외선 LED
기계적 치수10 × 25 × 64.3 mm
Fork Width / 깊이3 mm / 42 mm
연결M8 4‑pin male plug
인클로저 등급IP65
작동 온도-20℃~+60℃
하우징 재질Glass‑fiber‑reinforced PA plastic아픈

M84pin Pin Assignment

  1. 갈색: DC + (1030다섯)
  2. 하얀색: Teachin input
  3. 파란색: 0V/GND
  4. 검은색: NPN output Q

Adjustment via Panel Buttons

  1. Dynamic Teachin (autolearn labels): Press「+」and「」simultaneously for 1 sec, LED flashes; feed several labels through the fork slot, press「」to exit and save settings.
  2. 아니요 / NC switching: Hold「+」and「」for 6 sec to toggle lighton / darkon mode.
  3. Key Lockout: Hold「+」and「」for 3 sec to lock buttons against unintended operation.
  4. External teachin via white teachin pin can be triggered by PLC for fullyautomated production lines.

일반적인 응용 분야

Automatic labeling machines & label dispensers: label arrival and gap detection

투명한 / thinlabel detection; doubleoverlap label identification

포장, 기호 논리학, pharmaceutical highspeed labeling stations; up to 10 kHz switching frequency

Alternative Models in Same Series

  1. WFS340P415, Order No.6043921: identical mechanical dimensions, PNP 출력
  2. WFS340N115: fixed cable outlet (nonconnector version)

Domestic replacement selection criteria: fork width 3 mm, fork depth ≥40 mm, dynamic teachin supported, response ≤100 μs, NPN 출력.

Basic Troubleshooting

  1. 불안정한 감지: Perform dynamic teachin; ensure label web runs centrally without rubbing fork slot; avoid strong ambient light shining into the fork.
  2. No output at all: Verify M8 wiring; avoid reversed power polarity; confirm output load ≤100 mA.
  3. Buttons nonresponsive: Check whether keylock mode is activated.

Practical Application Cases for SICK WFS340N415 (Order No.6043920)

Key capabilities: 10 kHz switching frequency, dynamic teachin, NPN sinking output, 3 mm fork width, IP65 rating. Primarily for selfadhesive labelgap detection, transparentlabel sensing and doublelabel monitoring at labelpeeling stations.

Case 1 Highspeed Food & Beverage Labeler (종이 + PET transparent labels)

장비: Automatic roundbottle labelpeeling machine; line speed 180 bottles/min; paper labels and transparent PET sealing labels on glassine release liner.

Process challenges: Conventional colormark sensors frequently miss transparent labels; manual sensitivity adjustment is required when changing label stock; highprecision gap detection is needed for servo label feed control.

구현: Mount WFS340N415 at the labelpeeling edge. Run web while performing dynamic teachin to autocalibrate lightlevel differences among labelfacestock, liner and gap. NPN signal is sent to PLC to stop labelfeed servo for accurate peel positioning.

이익: Eliminates missed detection of transparent labels; oneshot dynamic teachin for label changeover without manual trimming; doublelabel overlap detection prevents feeding two labels at once and reduces packaging rejects.

Site note: IP65 housing tolerates condensation; prevent strong ambient light hitting the fork window.

Case 2 Pharmaceutical Industry-Cartridge / Vial Labeling & Traceability Coding Line

장비: Inline printandapply labeler for regulatory traceability labels; narrow labels with only 23 mm gaps; line speed 120 pcs/min.

Process challenges: Narrow labels and tiny gaps demand high resolution; PLCtriggered remote teachin is required for recipe switching.

구현: Use the white teachin pin for PLCdriven external teachin. PLC pulses trigger autothreshold calibration when switching product recipes; sensor output synchronizes printing and labeling actions.

이익: Reliable detection of narrow gaps; no manual button operation for recipe changeover; supports batch productswitching and prevents missing / misapplied labels.

Case 3 Dailychemical Industry-Hose / Flatbottle Dualsided Labeler

장비: Automatic labeling machine for cosmetic hoses with thinbacking selfadhesive labels; risk of label wrinkling and doublelabels.

Process challenges: Web jitter causes false triggers; heavy EMI from nearby servodrives and frequency inverters.

구현: Ground shielded M8 connector; install sensor at peeling station; run dynamic teachin on good web condition; enable output shortcircuit protection; activate keylock to block operator misconfiguration.

이익: Improved tolerance to web wrinkles; alarm on doublelabel overlap; keylock eliminates accidental parameter changes and reduces machine downtime.

Case 4 Electronics-Lithiumcell & PCB Label Inspection

장비: Automatic label applicator for polyimide (PI) hightemperature labels; intermittent highspeed feeding at 200 cycles/min.

Process challenges: Low optical contrast between PI label and liner; fast response requirement; confined installation space.

구현: Compact forkform factor fits cramped peelhead layout. 50 μs response and 10 kHz frequency support intermittent highspeed motion. Dynamic teachin learns lightlevel difference of PI label against its liner.

이익: Reliable labelpresent signal at high speed; consistent labeling accuracy and avoids offset labels on battery cells.

Case 5 Converting Industry-Rolllabel Rewind & Slitting Counter

장비: Label rewindslitting machine for continuous selfadhesive rolls; label counting and missinglabel detection on running web.

Process challenges: Continuous nonstop web; frequent labelmaterial changeovers.

구현: Label web passes through fork slot. Dynamic teachin identifies label gaps. Sensor pulse feeds PLC for label counting; missinglabel / webbreak condition stops machine via loss of pulses.

Nonlabel Specialpurpose Applications (limiteduse scenarios)

  1. Doublesheet detection for thin materials: Thin paper / 영화; overlapping sheets passing through fork change light transmission and trigger doublesheet alarm; minimum detectable thickness ~2 mm.
  2. Smallpart counting: Count thin flat discrete parts passing continuously through fork slot.

Key Site Lessons Learned from Field Cases

  1. Dynamic teachin is mandatory for transparent labels; do NOT rely solely on manual +/ adjustment, otherwise intermittent unreliable detection occurs.
  2. Leave white teachin pin tied to 0 V when unused. For PLCtriggered teachin, send ≥100 ms highlevel pulse.
  3. Keep label web centered inside fork; avoid rubbing emitter/receiver windows, which causes signal drift.
  4. Direct overhead lamp / daylight illumination onto fork slot creates false triggers; fit simple lightshield sheetmetal.
  5. NPNsinking output requires PLC sinkingtype input module; wrong input type yields zero signal.

Complete Standard Commissioning SOP for SICK WFS340N415

  1. Document Basic Information

목적: 표준화된 설치, 시운전, acceptance and maintenance guideline for labelers, dispensers and coding lines.

Applicable Model: WFS340N415 (Order No. 6043920, NPNsinking, M84pin male, dynamic teachin).

핵심 기능: Labelgap detection, transparentlabel sensing, doublelabel alarm, missinglabel alarm, highspeed labelfeed positioning.

  1. Precommissioning Safety & Prerequisites
  2. Power OFF before wiring / disassembly to avoid shortcircuit damage to sensor or PLC inputs.
  3. 공급: DC 1030 V, ripple <10 %. Avoid poorlyregulated power supplies.
  4. 설치환경: Keep away from direct bright light, condensation water, heavy EMI from servos / 주파수 변환기.
  5. Output load limit: Max. 100 mA; never exceed rated load.
  6. Pinout & 표준 배선

M84pin male, NPNsinking output, only compatible with sinkingtype PLC inputs:

  1. 갈색 (Pin 1): DC+, connect to 24 V positive.
  2. 하얀색 (Pin 2): External teachin input; tie to 0 V if unused; ≥100 ms highlevel pulse for PLCinitiated teachin.
  3. 파란색 (Pin 3): 0 다섯 / 접지, connect to power negative and PLC common.
  4. 검은색 (Pin 4): NPN signal output, connect to PLC digital input terminal.

Wiring Warnings: Never reverse brownblue power leads. Do NOT leave white teachin wire floating to prevent spurious false teachin triggers.

  1. Mechanical Installation Requirements
  2. Mounting location: At labelpeeler outlet; run label web horizontally and centrally through the 3 mm fork slot.
  3. 정리: Label web must NOT touch emitter or receiver windows; no friction or lateral offset.
  4. Fastening: Tighten mounting screws firmly. No mechanical vibration during highspeed web travel, to prevent measurement drift.
  5. Environmental protection: Install lightshield sheetmetal for brightlight stations. Maintain intact housing sealing for dusty / humid locations to satisfy IP65.
  6. Parameter Setup via Frontpanel Buttons

5.1 Dynamic AutoTeachin (primary operation)

For standard labels, transparentPET labels, PI hightemperature labels, and materialchange calibration:

  1. Poweron machine; thread label web and run at low speed.
  2. Hold【+】and【】together for 1 sec. LED flashes, entering teachin mode.
  3. Pull 510 complete cycles of “label + gap” through fork slot to let sensor autolearn lightdifference thresholds.
  4. Press【】to exit; 자동으로 저장된 매개변수.

5.2 Outputmode Toggle (아니요 / NC, Lighton / Darkon)

Hold【+】and【】for 6 seconds to toggle lighton / darkon; match to PLC program logic.

5.3 Button Lockout / Unlock

Hold【+】and【】3 seconds to lock or unlock frontpanel buttons to prevent accidental fieldside modification.

5.4 PLCtriggered External Teachin (for frequentrecipechange production lines)

  1. Connect white teachin wire to PLC digitaloutput point.
  2. PLC sends ≥100 ms highlevel pulse to trigger sensor teachin routine.
  3. Drop pulse after labelweb learning completes; parameters autosaved without local operator intervention.
  4. LED 상태 표시
  5. 계속 켜져 있음: Normal powered standby.
  6. 섬광: Teachin configuration mode.
  7. Flashes synchronously with label gaps: Normal detection and stable output signal.
  8. No LED / irregular flashing: 전원 결함, corrupted parameters or wiring shortcircuit.
  9. Machine Integration & Acceptance Criteria

7.1 Noload Test

Run empty releaseliner web; no false triggers or spurious output pulses.

7.2 Loadedweb Functional Test

  1. Normal labels: Precise pulses at each gap; reliable PLC counting & 포지셔닝.
  2. Missinglabel / webbreak: No output pulses; machine triggers alarm and stops.
  3. Doublelabel overlap: Abnormality detected and alarm activated.
  4. Highspeed operation: 180200 cycles/min web speed; zero missed detections and false triggers.

7.3 Acceptance Pass Criteria

  1. Zero detectionerror rate during continuous 30min run.
  2. No missed / false detection on transparent and thin labels.
  3. Fast adaption after materialchange teachin; no further trimming needed.
  4. No signal drift or EMIcaused false triggering over test period.
  5. Troubleshooting Summary
  6. 불안정한 감지: Rerun dynamic teachin; center label web; clean optical windows; fit lightshield.
  7. 출력 신호 없음: Doublecheck wiring; confirm PLC uses sinkinginput mode; inspect supply voltage; rule out output overload.
  8. Constanton output cannot reset: Toggle NO/NC lighton/darkon setting; redo dynamic teachin; investigate abnormal liner lighttransmission.
  9. Buttons unresponsive: Hold【+】&【】3 sec to unlock keylock.
  10. Missed detection at high speed: Reperform dynamic teachin; tighten mounting bracket; stabilize web transport speed.
  11. Routine Maintenance Instructions
  12. 일일: PowerOFF then wipe forkslot windows to remove dust and adhesive residue.
  13. 주간: Check tightness of mounting screws and wiring terminals to eliminate intermittent poorcontact.
  14. Mandatory action upon materialchange: Always perform dynamic teachin after changing label material, thickness or color.
  15. Longterm storage: Poweroff unit; avoid humid and hightemperature environments accelerating aging.
  16. Common Field Pitfalls & 메모
  17. For transparent labels do NOT manually adjust sensitivity; always perform dynamic teachin, or unstable detection results occur.
  18. This NPNsinking sensor works only with sinkinginput PLC hardware. For sourcinginput PLC systems select PNPversion WFS340P415.
  19. Teachin white wire must not float; tie to 0 V when unused.
  20. Never let label web rub optical windows; rubbing causes permanent optical offset and parameter drift.
  21. When installed close to servos and inverters, apply cable shielding and proper grounding to mitigate electromagnetic interference.

Standard Fault & Remedy Table for SICK WFS340N415

  1. Unstable / intermittent detection

Root cause: Missing dynamic teachin; lateral web offset; contaminated optical window; direct ambientlight intrusion.

치료: Execute dynamic teachin; recenter label web path; clean fork windows; install lightshield sheetmetal.

  1. Zero sensor output signal

Root cause: 잘못된 배선; PLC sourcinginput module incompatible with NPNsinking; supplyvoltage anomaly; outputcircuit overload.

치료: Crosscheck M8 pinassignment wiring; configure PLC for sinkinginput; verify DC24 V supply; keep output load ≤100 mA.

  1. Output stays high and cannot reset

Root cause: Lighton / darkon setting mismatches PLC logic; unusual liner lighttransmission property; sensorparameter drift.

치료: Toggle NO/NC mode via buttons; rerun dynamic teachin; inspect / replace defective releaseliner stock.

  1. Frontpanel buttons have no reaction

Root cause: Buttonlockout function is active.

치료: Hold【+】and【】3 seconds to unlock buttons.

  1. Missed detection under highspeed operation

Root cause: No reteachin for highspeed condition; loose mounting bracket; web mechanical jitter.

치료: Rerun dynamic teachin for sensitivity calibration; secure mounting hardware; stabilize webtransport velocity.

이전:

답장을 남겨주세요

메시지를 남겨주세요