Siemens MXG461.20-5.0 Solenoid Modulating Valve - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

Siemens MXG461.20-5.0 Solenoid Modulating Valve - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

전기 같은/

Siemens MXG461.20-5.0 Solenoid Modulating Valve

This is a 3-way/2-way solenoid proportional modulating valve with DN20 (3/4″) threaded connection and a Kvs value of 5.0 m³/h. It operates on 24V AC/DC power supply, with selectable control signals: 0-10다섯 / 2-10다섯 / 4-20엄마. It features a positioning time of less than 2 초, a resolution of 1:1000 and an IP54 protection rating. ...

  • 제품 세부정보

This is a 3-way/2-way solenoid proportional modulating valve with DN20 (3/4″) threaded connection and a Kvs value of 5.0 m³/h. It operates on 24V AC/DC power supply, with selectable control signals: 0-10다섯 / 2-10다섯 / 4-20엄마. It features a positioning time of less than 2 초, a resolution of 1:1000 and an IP54 protection rating. It is designed for mixing and straight flow control of cold and hot water in closed HVAC systems.

  1. 모델 코드 설명
코드 세그먼트설명
MXG제품 시리즈 코드: MX stands for solenoid actuator; G stands for external thread connection, suitable for cold and hot water systems
461Model type code: ACVATIX™ series solenoid control valve, PN16 pressure rating
0.2Nominal diameter DN: 20mm (3/4 인치)
-5Kvs flow coefficient: 5.0 m³/h (flow rate of cold water at 1 bar pressure differential)
(Suffix P)Optional version: For media containing mineral oil (SAE05SAE50)
(접미사 U)Optional version: Equipped with NPT thread fitting set
  1. Main Technical Specifications
범주명세서비고
기본 매개변수
Valve TypeSwitchable 3-way mixing valve / 2-way straight valveNot applicable for diverting service
연결 유형External thread G1¼B (ISO 228-1)DN20 corresponds to 3/4 인치
Nominal PressurePN16 (1.6MPa)맥스. working pressure: 1000kPa
Flow CoefficientKvs=5.0 m³/h, Cv=5.9Cold water at 5-30℃, 1 bar pressure differential
Actuator Parameters
전원공급장치AC/DC 24V ±20% (셀프/PELV)빈도: 45-65헤르츠
Control SignalDC 0/2-10V or DC 4-20mA (DIP switch selectable)입력 임피던스: ≥100kΩ (voltage signal), 100오 (current signal)
Position FeedbackDC 0-10V (Load resistance >500오)Non-wear inductive measurement
Positioning Time< 2 초빠른 응답
Stroke Resolution0.736111111High regulating accuracy
보호 등급IP54Dustproof and splash-proof
Valve Body Parameters
Valve Body MaterialCast iron EN-GJL-250 (GG25)Plug: CrNi steel; Seat: 놋쇠
씰 재질EPDM (기준) / FPM (P형)For different media
Medium Temperature1-130℃For cold and hot water systems
Leakage RateA→AB: ≤0.02% Kvs; B→AB: ≤0.2% KvsAt Δp=0.1MPa
장착 위치Vertical to horizontal installation availableNo special angle restrictions
Fail-Safe FunctionPort A→AB closes automatically upon power loss (봄 귀환)Safety protection feature
물리적 매개변수
치수 (L1×L2×L3×H2)95×47.5×52.5×260mmUnder straight flow status
무게4.2kg
  1. 전체 시리즈 모델 목록
모델DNKvs (m³/h)연결 유형Applicable Medium비고
MXG461.15-0.6150.6외부 스레드추운 & 뜨거운 물표준 모델
MXG461.15-1.5151.5외부 스레드추운 & 뜨거운 물표준 모델
MXG461.15-3.0153외부 스레드추운 & 뜨거운 물표준 모델
MXG461.20-5.0205외부 스레드추운 & 뜨거운 물현재 모델
MXG461.25-8.0258외부 스레드추운 & 뜨거운 물표준 모델
MXG461.32-123212외부 스레드추운 & 뜨거운 물표준 모델
MXG461.40-204020외부 스레드추운 & 뜨거운 물표준 모델
MXG461.50-305030외부 스레드추운 & 뜨거운 물표준 모델
MXG461.XX-XXP15-500.6-30외부 스레드Mineral oilVersion for oil media
MXG461.XX-XXU15-500.6-30외부 스레드추운 & 뜨거운 물Version with NPT fittings
MXF461.XX-XX15-650.6-50플랜지추운 & 뜨거운 물Flanged version
  1. Cross-Brand & 교체 모델 참조
범주모델Matching Rate차이점
지멘스 등가 모델MXG461.20-5.0P100%Only seal material changed to FPM, suitable for mineral oil
MXG461.20-5.0U100%Supplied with NPT thread fittings for easier installation
MXF461.20-5.095%Flanged connection type, different mounting method
국내 대안Muyi MVC20-5.090%Identical functions, 대략. 60% of Siemens price, response time 2-3s
Chuanyi ZDLP-20K85%Electric actuator, slightly lower accuracy, IP65 rating
Imported CompetitorsHoneywell V5011P201090%Similar structure and price, positioning time around 2s
Danfoss AVTA20-5085%Slightly different flow characteristics, operating temperature 2-120℃
  1. 응용 환경 & 산업 사례

5.1 적용 가능한 시나리오

HVAC 시스템: Cold/hot water mixing control and fan coil unit temperature regulation for commercial buildings, hotels and hospitals

District Heating: Secondary hot water temperature control for residential communities and office parks

Industrial Temperature Control: Water flow regulation for chillers and heat pumps, cooling systems for data centers

공정 냉각: Temperature control loops for plastic molding machines and printing equipment

5.2 Not Recommended Scenarios

Media with solid particles (A pre-filter with filtration accuracy ≥100μm is required)

Vacuum systems or working conditions with high pressure differential (>300kPa)

Diverting flow applications (For mixing and straight flow only)

Corrosive media (Select MXG461S stainless steel version)

5.3 일반적인 적용 사례

사례 1: HVAC System of Commercial Complex

Project: HVAC water system renovation for a 30-floor shopping mall

애플리케이션: Cold and hot water mixing control for air handling units on each floor, 총 80 sets of MXG461.20-5.0

Outcome: Temperature control accuracy improved to ±0.5℃, energy consumption reduced by 18%, response speed tripled

사례 2: Industrial Water Chiller

장비: 500RT screw chiller

애플리케이션: Chilled water outlet temperature control (7℃), 4 units operated in parallel

특징: Matched with Siemens PLC for 0-10V proportional control, water temperature fluctuation stabilized below 0.3℃

  1. 문제 해결 & 유지보수 가이드
결함 현상가능한 원인문제 해결 단계솔루션
Valve fails to operate1. No power supply1. Measure terminal voltage (24V±20%)1. Repair power circuit
2. Missing control signal2. Check 0-10V/4-20mA control signal2. Inspect controller output
3. Actuator failure3. Manual operation test (Turn handwheel clockwise)3. Replace ASE1 electronic module
Poor regulating accuracy1. Position offset1. Perform auto-calibration (Long press calibration button)1. Recalibrate the valve
2. Incorrect valve characteristic setting2. Check DIP switch (선의 / Equal percentage)2. Reset DIP switch
3. Impurities in medium3. Inspect filter cleanliness3. Clean the filter
Excessive leakage1. Aged seals1. Check seal condition1. Replace EPDM seals
2. Worn valve seat2. Measure leakage under closed status2. Replace valve seat assembly
3. Excessive pressure differential3. Confirm system pressure differential ≤300kPa3. Install bypass valve to reduce pressure difference
Abnormal feedback signal1. Faulty feedback wiring1. Measure feedback terminal voltage (0-10다섯)1. Repair feedback wiring
2. Damaged electronic module2. 모듈 표시등을 확인하세요.2. Replace electronic module
3. Defective inductive sensor3. Inspect sensor connection3. Replace inductive sensor

유지보수 일정

Maintenance Item주기Operation Content
육안검사월간 간행물Check valve body and actuator for damage and loose connections
Filter Cleaning계간지Clean inlet filter to prevent impurity ingress
Auto-Calibration반년마다Execute auto-calibration to ensure positioning accuracy
Seal Inspection매년Check seal aging and replace if necessary
Overhaul모든 3 연령Dismantle for internal inspection and replace wearing parts
  1. 선택 지침
  2. 세 가지 주요 선택 요소: DN size (match pipeline) → Kvs flow rate (meet system demand) → Medium type (Standard type for cold/hot water, Type P for mineral oil)
  3. Signal Selection: DC 0-10V for general control; DC 4-20mA for long-distance transmission (강력한 간섭 방지)
  4. 설치 팁: Follow the flow direction marked on the valve body; do not use as diverting valve; 4-wire connection for power and signal ensures higher stability
  5. Fault Judgment: Automatic shutdown after power loss (봄 귀환) is a standard safety function; manual operation can quickly verify mechanical performance
  6. 주문 정보

표준 모델: MXG461.20-5.0 (BPZ:MXG461.20-5.0)

추천 액세서리: ALG203 thread fitting set (3 union nuts + 3 gaskets + 3 일반 와셔), Z155/20 blind flange set

Replacement Module: ASE1 electronic module (Applicable for DN15-32)

Supplementary Application Description

MXG461.20-5.0 is a DN20 solenoid proportional modulating valve with Kvs=5.0. It is mainly used for continuous and precise temperature control in closed cold and hot water systems. Featuring fast positioning (<2에스) and high resolution (1:1000), it is only applicable for mixing and straight flow, not for diverting service.

  1. 공조 & 냉각 (Primary Application)

Air Handling Units / Fresh Air Units: Proportional regulation of cold/hot water coils to stabilize supply air temperature (±0.5℃)

Fan Coil Units (FCU): Terminal temperature control for high-rise and commercial buildings, available for 2-way on/off or 3-way mixing flow

Chilled Water Systems: Water temperature regulation and bypass mixing control for chillers

Cooling Tower Control: Stabilize cooling water temperature and save energy

Computer Room Precision Air Conditioning: High-precision water temperature control for data center and equipment room cooling

  1. District Heating & Boiler Systems

Heat Exchanger Stations: Secondary hot water temperature regulation and mixing loop control

Radiant Floor Heating: Limit supply water temperature (35–45℃) and prevent overheating via 3-way mixing

Boiler Load Control: Stabilize hot water outlet temperature and follow system load changes

Domestic Hot Water (DHW): Mix cold and hot water to provide constant-temperature water (예를 들어. 45–55℃)

  1. Industrial Process & Special Media

공정 냉각: Precise cooling water temperature control for injection molding machines, printing machines and lasers

Mold Temperature Controllers: Proportional regulation for thermal oil and hot water circuits (Type P for mineral oil)

음식 & 제약 산업 (Sanitary Application): Closed-loop temperature control for pure water and hot water

Solar Water Heating Systems: Mix water from solar collectors and return water for constant water supply

  1. Typical Circuit Applications

3-way Mixing (Combining Flow): Mix high-temperature primary water and low-temperature secondary water to stabilize supply water temperature (most common application)

2-way Straight Flow: On/off or proportional regulation for coil/equipment inlet, automatic shutdown upon power loss for safety

Bypass / Differential Pressure Control: Stabilize system pressure difference and balance flow under partial load

  1. Disqualified Application Scenarios

❌ Media with solid particles (Pre-filter ≥100μm required)

❌ Diverting flow service (Mixing and straight flow only)

❌ Vacuum conditions, high pressure differential (>300kPa) or highly corrosive media

❌ Steam systems (Operating medium: cold/hot water and thermal oil, 1–130℃)

  1. Application Matching Based on Core Advantages

빠른 응답 (<2에스): Ideal for systems with fluctuating load requiring rapid temperature stabilization, such as HVAC terminals and process cooling

High Resolution (1:1000): Suitable for high-precision temperature control scenarios including precision air conditioning, pharmaceutical and electronic manufacturing

전원 끄기 안전 (Port A→AB Closed): Safety loop for heating and hot water systems to avoid overheating and scalding risks

이전:

답장을 남겨주세요

메시지를 남겨주세요