ASV310F-01-06에스
- ASV: Series Code → Speed Exhaust Controller (Integrated speed control + quick exhaust function)
- 310에프: Size Series
310: Valve body dimension; F = Integrated quick exhaust function (Standard ASV without F has no quick exhaust)
- 01: Thread Port → Rc1/8 (Female Thread)
- 06: Tube Outer Diameter → φ6mm PU Air Tubing
- 에스: One-way throttling direction identifier
Specification S: Free flow for air supply, throttling for exhaust; Throttling + quick exhaust fitted on cylinder exhaust port to improve cylinder retraction speed
- 핵심사양
| 목 | 매개변수 |
| 제품명 | ASV Series Speed Exhaust Controller |
| Valve Thread | Rc1/8 |
| Compatible Tubing | Φ6 Polyurethane Hose |
| 조정 방법 | Knob throttling with lock nut |
| 작동 매체 | 압축공기 (Oiled / Oil-free operation available) |
| 작동 압력 | 0.05~0.8 MPa |
| 주변 온도 | 0~60℃ (No icing) |
| 장착 방법 | Direct mounting on cylinder port |
| Flow Definition (S형) | Supply air: Unrestricted flow; Exhaust air: Throttling + quick exhaust |
- 작동 원리
ASV-F integrates check valve + throttle valve + quick exhaust valve
Cylinder extend: Compressed air flows into the valve body, the check valve opens, airflow bypasses throttling, full-speed extension.
Cylinder retraction: Internal cylinder air discharges outwards, the check valve closes; air can only pass through the throttle knob for speed regulation. 그 동안에, the built-in quick exhaust channel discharges directly to atmosphere, reducing the influence of piping volume and greatly improving response speed during cylinder retraction.
- Piping & Connection Instructions
- Mount the valve body with Rc1/8 internal thread directly onto cylinder port
- Connect Φ6 tubing to one-touch port (Push-fit for quick assembly & 분해)
- Adjustment knob: Clockwise → Reduce flow, lower speed; Counterclockwise → Increase flow
- Tighten lock nut after adjustment to prevent drift caused by vibration
- 일반적인 애플리케이션 시나리오
Retraction speed boost for compact cylinders (CDQ2B, CJ2A, MB series)
Manipulators, tooling fixtures, pushing mechanisms requiring fast return and controllable forward speed
Short-stroke cylinders, eliminate exhaust lag caused by long piping
- 선택 가이드 & 교체 정보
- Distinguish Type S / 에이
ASVxxx-xx-xxS: Exhaust throttling (가장 일반적인, standard cylinder speed control)
ASVxxx-xx-xxA: Inlet throttling, rarely used – avoid wrong selection
- Similar models within the same series
ASV310F-01-04에스: Rc1/8, Φ4 tubing
ASV310F-02-06에스: Rc1/4, Φ6 tubing
- Standard ASV310 (without F) cannot be directly replaced; no built-in quick exhaust, obvious difference in retraction speed
- 일반적인 문제 해결
- Slow cylinder movement: Throttle knob closed too far; tubing flattened; joint leakage
- Invalid speed regulation, unstable speed: Loose lock nut leading to knob rotation; foreign particles jamming internal check valve
- 공기 누출: Tubing not fully inserted; insufficient PTFE tape on thread; worn internal valve seals
Complete Datasheet Package – SMC ASV310F-01-06S Speed Exhaust Controller
- 장착 치수 (ASV310F-01 Series Rc1/8)
단위: mm
| 매개변수 | 값 | 메모 |
| 스레드 사양 | Rc1/8 (Taper External Thread) | Directly screwed into cylinder port |
| Compatible Tubing | Φ6 PU / Nylon Hose | Push-in one-touch fitting |
| Overall Length L1 | 45.8 | Maximum valve length |
| L2 | 39.8 | Main body length |
| Valve Width H | 26.5 | T-type body width |
| Max Outer Diameter of Adjustment Knob D1 | 16.8 | Including lock nut |
| One-touch Port | Suitable for Φ6 tubing | Push-release connection |
| 순중량 | 대략. 14g | |
| Total Adjustment Turns of Needle Valve | 12 회전 | Fully Open ↔ Fully Closed |
Dimension Access: Search model on SMC Global Part Builder to download STEP/IGS 3D Models, DXF 2D Drawings
Official Website: Search ASV Series in SMC Global e-catalog
- Key Abstract from English & Chinese Catalog
Chinese Specification
제품명: Speed Exhaust Controller with Built-in Silencer
모델: ASV310F-01-06에스
- 작동 매체: 압축공기 (Oiled / Oil-free)
- 보증 압력: 1.5 MPa
- 작동 압력 범위: 0.1~1.0 MPa
- 주변 & 유체 온도: -5℃~60℃ (No icing allowed)
- 본체 재질: Flame-retardant resin UL94 V-0; Metal parts with electroless nickel plating
- Flow Definition (Type S Exhaust Throttling)
입구 (Thread → Tubing): Check valve fully open, unrestricted airflow
배기가스 (Tubing → Atmosphere): Air passes through adjustable needle valve, built-in quick exhaust channel + silencer for direct atmospheric discharge
- Effective Flow Area: Roughly doubled compared to standard AS speed controller, significantly improved cylinder retraction speed
- Compatible Tubing: Polyurethane PU, 부드러운 나일론, hard nylon tubing
- 흐름특성 (Key for Selection)
- IN→OUT (Air Supply): Large flow area, negligible pressure drop, cylinder extends at full speed
- OUT→EXH (배기가스): Adjustable throttling with simultaneous quick exhaust
- 적합: Short-stroke cylinders, applications requiring fast retraction response, no need for separate external quick exhaust valve.
⚠️ Comparison with standard ASV310 (without F): No built-in quick exhaust, severe exhaust lag in long piping, 교환불가.
- Replacement Model List
1) Direct SMC OEM Replacement (동일한 기능)
ASV310F-N01-06S: Thread changed to NPT1/8 (American thread; confirm thread standard before installation)
❗ Mismatched thread prevents direct mounting; Rc1/8 preferred for domestic standard
2) 국내 호환 대안 (Consistent structure, 차원 & flow direction)
| Import Model | Domestic Equivalent | 주목 |
| ASV310F-01-06에스 | JASV310F-01-06에스 (Xingchen / Shannais) | T-type, built-in silencer, Type S exhaust throttling |
| ASV310F-01-06에스 | PSV310F-01-06에스 | General imitation ASV model widely available |
메모: Many domestic manufacturers distinguish Type A/S; confirm suffix S = exhaust throttling. Low-cost variants may not meet UL-V0 flame resistance; avoid for welding environments.
3) Airtac Alternative Solution
Airtac does not manufacture integrated speed exhaust controllers with identical form factor. Alternative combination: PSL601 (Exhaust Speed Controller) + QE01 Quick Exhaust Valve. Larger overall installation footprint.
- 설치, Commissioning Specifications & 금지된 작업
설치 단계
- Wrap PTFE tape on external thread only (Do not block internal flow passage)
- Tightening torque for Rc1/8 thread: 2.5~3.5 N·m. Excessive torque cracks resin valve body
- Vertically insert Φ6 tubing into fitting until audible “딸깍 하는 소리” confirms locking
- 조정: Counterclockwise → Larger flow; Clockwise → Smaller flow
- Lock side nut after speed setting to avoid vibration drift
⚠️ Strictly Forbidden Operations
- Prohibited for vacuum circuits; Medium limited to compressed air only
- Operating pressure shall never exceed 1.0 MPa
- Do not block built-in exhaust silencer port; Blockage disables quick exhaust and causes cylinder stalling
- Avoid sharp bending of fitting root, which leads to air leakage
- Optional splash guard recommended for heavy dust environments (ASV310F optional accessory)
- Related Series Reference (Procurement Alternatives)
ASV310F-01-04S Rc1/8, Φ4 tubing
ASV310F-01-08S Rc1/8, Φ8 tubing
ASV310F-02-06S Rc1/4, Φ6 tubing
SMC ASV310F-01-06S Speed Exhaust Controller | Full Official Technical Specification
- Model Code Analysis
ASV310F-01-06에스
ASV: Speed Exhaust Controller
310: Valve body size (T-type integrated quick exhaust speed controller)
에프: Built-in quick exhaust function
01: Thread Specification R1/8 External Taper Thread (Matched with Rc1/8 internal thread)
06: Compatible tubing outer diameter Ø6mm
에스: Exhaust throttling type (OUT→EXH throttling; IN→OUT direct flow)
- General Official Specifications (SMC Catalog)
| 매개변수 항목 | 값 |
| Full Product Name | ASV Series Speed Exhaust Controller with Integrated Quick Exhaust & 소음 장치 |
| 작동유체 | 압축공기 (Clean dry air, oil-free / oil-lubricated acceptable) |
| 보증 압력 | 1.5 MPa |
| 최대 작동 압력 | 1.0 MPa (10 술집) |
| Minimum Operating Pressure | 0.1 MPa (1 술집) |
| Fluid / 주변 온도 | -5℃ ~ +60℃, no icing permitted |
| Flow Definition (S형) | IN→OUT: Check valve fully open, no throttling; OUT→EXH: Adjustable throttling + quick exhaust |
| Compatible Tubing | PU Polyurethane Tubing, Soft Nylon Tubing, Hard Nylon Tubing |
| 표준 구성 | Integrated one-touch fitting, built-in PVA silencer sponge, hexagon lock nut |
| Flame Resistance Class | Valve body PBT resin UL94 V-0 (Suitable for welding environments) |
| RoHS 준수 | RoHS directive compliant |
- Flow Performance Data (ASV310F-01 시리즈)
| 흐름 방향 | Sonic Conductance C [dm³/(s·bar)] | Critical Pressure Ratio b |
| IN → OUT (Supply Channel) | 7 | 0.25 |
| OUT → EXH (Fully open exhaust throttle) | 8 | 0.15 |
Performance Note: Effective flow area approx. twice of standard AS speed controller; Greatly reduced exhaust backpressure and shortened cylinder retraction response time.
- Material List
| 부품명 | 재료 | 표면 처리 |
| Valve Body | PBT Resin | UL94 V-0 Flame Retardant Grade |
| Thread Base, Needle Valve, Guide Sleeve | 놋쇠 | Electroless Nickel Plating |
| One-way Sealing Spool | HNBR Rubber | — |
| O-rings, Sealing Gaskets | NBR Nitrile Rubber | — |
| Silencer Element | PVA Porous Sponge | 내장, non-detachable |
| Adjustment Knob | PBT Resin | — |
| Lock Nut | 강철 | Chromate Zinc Plating |
- External Dimensions (단위: mm)
| Dimension Name | 값 | 메모 |
| 스레드 사양 | R1/8 External Thread | Directly screwed onto cylinder port |
| Compatible Tubing OD | Ø6mm | Push-in one-touch fitting |
| Overall Valve Length L1 | 45.8 | Maximum outer length |
| Main Body Length L2 | 39.8 | Excluding fitting protrusion |
| Valve Width H | 26.5 | T-type body width |
| Max Outer Diameter of Adjustment Knob D1 | 16.8 | Including lock nut |
| Total Needle Valve Adjustment Turns | 12 회전 (Fully Open ↔ Fully Closed) | |
| 순중량 | 대략. 14 g |
- Installation Technical Specification
- Thread tightening torque: 2.5~3.5 N·m
Excessive torque causes cracking of resin valve body; Avoid forced tightening.
- Apply PTFE tape only on external thread; Do not insert tape into internal flow channel.
- Fully insert Ø6 tubing into fitting until audible “딸깍 하는 소리”; Press release ring for tube removal.
- Speed regulation direction: Counterclockwise rotation → Flow increase; Clockwise → Flow reduction. Lock nut after adjustment to prevent vibration drift.
- 옵션 액세서리
- Splash guard (For welding dust environments)
- Round lock nut (Standard equipped with hexagon nut)
- Operating Boundaries & Prohibitions
✅ Suitable Applications: Cylinder retraction acceleration, short-stroke pneumatic fixtures, mechanical pushing mechanisms
❌ Prohibited Operating Conditions
- Must not be used in vacuum circuits
- Do not block EXH exhaust port on valve base (Blockage disables quick exhaust, cylinder jamming occurs)
- Operation forbidden below -5℃ with icing risk
- Long-term operation above 1.0 MPa accelerates seal aging
- External dust cover recommended for heavy dust conditions to prevent silencer sponge blockage
접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지