Telemecanique XMLB010A2S11 Electromechanical Pressure Switch

상표: 텔레메카니크 센서 (formerly Schneider OsiSense XM series, now part of YAGEO) 유형: Diaphragm type, adjustable differential pressure switch with dual setpoints, local scale indicator, 1 전환 연락처 (1콜로라도) ✅ Pressure Specifications Rising pressure setting range: 0.7~10 bar Falling pressure reset range: 0.13~9.15 bar Minimum differential: 0.57 술집; maximum differential: 7.5 bar Instantaneous overload pressure: ...

  • 제품 세부정보

상표: 텔레메카니크 센서 (전에 슈나이더 OsiSense XM series, now part of YAGEO)

유형: Diaphragm type, adjustable differential pressure switch with dual setpoints, local scale indicator, 1 전환 연락처 (1콜로라도)

✅ Pressure Specifications

Rising pressure setting range: 0.7~10 bar

Falling pressure reset range: 0.13~9.15 bar

Minimum differential: 0.57 술집; maximum differential: 7.5 술집

Instantaneous overload pressure: 22.5 술집; continuous maximum working pressure: 12.5 술집

파열 압력: 45 술집

Sensing element: 횡격막; wetted materials: FPM/FKM fluoroelastomer + zinc alloy

Compatible media: 압축공기, 정수, 유압유; medium temperature: 0~70 ℃

✅ Process & 전기 연결

프로세스 연결: G1/4 내부 스레드 (ISO228)

Electrical entry: Pg13.5 케이블 글랜드, cable OD 9–13 mm; 나사 터미널, wire size 0.5~2.5 mm²

연락하다: 1콜로라도 (13-14-11-12) silver contact, 스냅 액션

접점등급: AC-15 120V/3A; 240V/1.5A; DC-13 250V/0.1A

절연전압 Ui: 500다섯(IEC); impulse withstand voltage Uimp: 6 kV

보호 등급: IP66

반복성: ±2%; maximum switching frequency: 120 사이클/분

기계적 수명: 5 백만 사이클

주변 온도: -25~70 ℃; 보관 온도: -40~70 ℃

✅ Dimensions & 무게

너비 35 mm × 높이 113 mm × 깊이 75 mm; 순중량 0.705 kg; mounting in any orientation

✅ Approvals & 표준

CE, UL508, CSA, IEC60947-5-1; marine classification approval; 기원: 체코 / 모로코 가죽; 보증: 18 개월

✅ 일반적인 애플리케이션

공기 압축기, hydraulic power packs, water supply pumps, 윤활 시스템, 공조, general industrial pressure start/stop, high/low pressure interlock protection

✅ Cross-Series Replacement Reference

XMLB shares the same platform with XMLA/XMLC/XMLD. Please distinguish pressure ranges (0.25/10/16/25 술집), contact quantity and indicator versions. Legacy models XM2JM, XMJ can be replaced with XMLB.

Telemecanique XMLB010A2S11 Pressure Switch Installation Manual

Applicable series: XMLA / XMLB / XMLC / XMLD same-platform electromechanical pressure switches. 모델: XMLB010A2S11, 10 바 범위, adjustable differential, 1CO changeover contact, G1/4 내부 스레드, Pg13.5 gland, IP66

⚠️ Precautionary Safety Warnings (Read First)

  1. Do NOT disassemble, wire or adjust under pressure or live power. Depressurize the system and isolate control power before any work.
  2. Approved media: 압축공기, 정수, standard hydraulic oil. Strong corrosive media or high-temperature media are prohibited (max medium temperature 70 ℃).
  3. Pressure must not exceed instantaneous overload 22.5 bar or burst pressure 45 술집. Overpressure will permanently damage the diaphragm and void protection function.
  4. Contacts are designed for control circuits only. Do not switch main motor power directly. AC-15 120V 3A / 240V 1.5A, DC-13 250V 0.1A.
  5. IP66 rated. For outdoor installation, avoid direct sunlight and continuous heavy spray. Tighten the cable gland fully for sealing.
  6. 시운전, calibration and maintenance must be performed by qualified pneumatic/hydraulic and low-voltage electrical personnel.
  7. Unpacking Inspection

모델 확인: XMLB010A2S11

Check housing and thread for cracks or damage; confirm scale plate intact, gland and sealing washer supplied

부속품: Unit only, fitted with Pg13.5 cable gland; no adapter included

명판 대조 확인: 0.7~10 bar range, 1CO contact, G1/4 ISO228 internal process thread

  1. 기계적인 설치

2.1 장착 요구 사항

장착 방향: 모든 위치 (XMLB has no mandatory upright requirement). Prioritize easy visibility of the scale.

Keep away from high heat sources and heavy vibration (excessive vibration causes false tripping and shortens service life).

It is recommended to fit an isolation valve + drain valve at the tapping point for future calibration and replacement without full system shutdown.

Tapping point: Take pressure from the side wall of pipe runs. Avoid high points (air accumulation) and low points (sediment build-up).

2.2 Thread Connection (G1/4 Internal BSP)

  1. Clean male thread, remove burrs and metal debris to prevent particles entering the diaphragm chamber.
  2. 씰링: Use PTFE tape only on the male thread. Do not push tape residue into the switch internal thread as debris may jam the diaphragm.
  3. Tightening: Use a spanner on the bottom hexagonal process base only. Never clamp the plastic housing — this will damage the internal mechanism.
  4. Torque moderately until leak-tight; do not force over-tightening.

옵션 액세서리: G1/4 to NPT1/4 adapter for NPT piping systems.

2.3 Piping Recommendations

Keep impulse tubing short and large bore to reduce response lag. Long tubing may cause slow response and chattering.

Install a pre-filter for media with solids to protect the FKM fluoroelastomer diaphragm.

Drain water-filled systems in cold environments to prevent freezing; ice expansion ruptures the diaphragm.

  1. 전기 배선

3.1 케이블 사양

케이블 외경: 9~13 mm (matches Pg13.5 gland)

도체 단면적: 0.5~2.5mm² (AWG20~AWG14); ferrules are recommended for stranded conductors.

3.2 터미널 정의 (1CO dry contact)

단말기정의설명
11COM흔한
12NC평상시 닫힘: Conducts below set pressure, opens at trip pressure
14아니요상시 개방: Closes at trip pressure, opens at low pressure

마킹 13: Some versions mark 13 alongside 14 for the same NO circuit; follow housing marking.

3.3 배선 절차

  1. 전원 분리, remove top cover screws and open the lid.
  2. Loosen Pg13.5 gland nut, feed cable through and strip to suitable length.
  3. Insert wires into terminals and tighten screws securely to avoid loose connections.
  4. Route cables clear of the internal spring adjustment assembly. Refit cover and tighten screws evenly.
  5. Tighten gland and compress rubber seal to maintain IP66 integrity. Poor gland sealing causes water ingress and failure.

배선 참고사항: This is a passive dry contact. No supply voltage is carried by the switch. PLC or relay control power must be supplied externally.

  1. Pressure Setting & 구경 측정 (XMLB dual setpoint: trip point + 미분)

XMLB operation: Two adjustment screws: high setpoint (trip pressure) and differential (히스테리시스). The low reset point is not independently adjusted.

Specification range for this model:

Rising trip pressure: 0.7~10 bar

Falling reset pressure: 0.13~9.15 bar

Minimum differential 0.57 술집, maximum differential 7.5 술집

Calibration Steps

  1. Fully depressurize the line.
  2. Open the front scale cover to access the two adjustment screws with graduated scale.
  3. Connect a reference pressure gauge (accuracy ≥0.5 class). The built-in scale is only for rough setting.
  4. Raise pressure slowly while monitoring the reference gauge:

Main adjustment screw: Sets trip pressure. At this pressure, contact state reverses (닫히지 않음, NC 오픈).

Differential screw: Sets the pressure gap between trip and reset. Larger differential means greater pressure drop before reset.

  1. Cycle pressure up and down 2–3 times to confirm stable trip and reset points with no drift.
  2. Refit protective cover after setting to prevent accidental adjustment. Record values and apply identification label.

✅ Typical example (펌프 시작-정지):

Start at 3 술집, stop at 5 bar → differential = 2 술집. Pump stops at 5 술집, restarts at 3 술집.

메모: The built-in scale is approximate. Safety interlock applications must be calibrated against a certified reference gauge; accuracy ±2%.

  1. Commissioning Check
  2. Confirm no leakage, secure wiring and intact housing sealing.
  3. Ramp pressure slowly through working range and verify contact switching matches settings.
  4. Complete multiple cycles to confirm no chattering or rapid cycling.
  5. Verify contact load stays within rated limits; fit fuse protection for control circuits.
  6. 기록: trip pressure, reset pressure, 메디아, ambient temperature and calibration date.
  7. 유지
  8. 정기점검: 누출, 케이블 손상, gland water ingress and housing corrosion.
  9. Calibration interval: 6–12 months for standard air compressor / water pump service; quarterly calibration for safety interlock duty.
  10. 청소: Wipe housing externally only. Do NOT disassemble the process chamber. Diaphragm removal destroys sealing and accuracy.
  11. Long-term shutdown: Depressurize and drain the chamber. Drain water circuits to prevent corrosion and freezing.
  12. 기계적 수명: 5 백만 사이클. Replace at end of life.
  13. 오류 문제 해결 표
징후가능한 원인치료
Switch does not actuate at set pressureDiaphragm jammed by debris; differential set too large; 끊어진 배선Depressurize, inspect or replace unit; reset differential; 배선을 확인하세요
Rapid cycling / chatteringDifferential set too small; pressure pulsation in pipingIncrease differential; fit snubber or accumulator
Trip pressure drifts out of tolerance과압 충격; diaphragm aging; 과도한 진동Replace switch; add vibration dampening and surge protection
물 유입 / internal corrosionLoose gland, missing cover gasketReseal assembly; replace unit if sealing parts are damaged
Leakage at threadPTFE tape misapplied; cracked base from over-tighteningRe-seal thread; replace unit if base is cracked

Telemecanique XMLB Series Electromechanical Pressure Switch – Fault Troubleshooting Guide

For XMLB010A2S11, diaphragm type, adjustable differential, 건식 접촉. Always depressurize and isolate power before troubleshooting; test contacts with multimeter continuity mode.

결함 증상근본 원인검사 단계시정 조치
No switching when pressure reaches setpoint1. Tapping port / impulse line blocked by sludge, scale or debris2. Diaphragm jammed or ruptured3. Setpoint higher than system working pressure4. Internal adjustment thread stripped or spring seized5. Failed microswitch1. Depressurize and inspect tapping port2. Use reference gauge to confirm actual system pressure3. Test COM-NO / COM-NC continuity with multimeter1. Clear impulse line and add inlet filter2. Reduce trip setpoint and lock screw3. Replace complete unit if diaphragm or internal mechanism is damaged (diaphragm chamber not serviceable on site)
Switch fails to reset below reset pressure, contact stays latched1. Excessive differential setting2. 용접된 접촉 / 갇힌 (inductive load without surge suppression)3. Jammed mechanical linkage or fatigued spring4. Trapped pressure in piping, no pressure relief1. Test continuity after full depressurization2. Check differential scale and verify relief valve operation1. Reduce differential within published range2. Replace switch; add intermediate relay and RC snubber for inductive loads3. Clear piping to enable free pressure relief
Rapid cycling / chattering1. 미분 (히스테리시스) set too low2. Pulsating pressure from pump / compressor3. Insufficient accumulator volume or failed bladder4. Tapping point located in turbulent flow zone1. Observe pressure gauge for small fluctuations2. Check current differential setting1. Increase differential (XMLB max differential 7.5 술집)2. Fit pressure snubber or buffer tank on impulse line3. Relocate tapping point to straight pipe side wall
Trip pressure inconsistent, drifting between cycles1. Spring fatigue from repeated pressure shock2. Permanent diaphragm deformation by overpressure3. Extreme temperature or continuous vibration4. Relying only on built-in scale without reference gauge calibration1. Compare trip/reset points over multiple cycles against certified gauge2. Check history of exceeding 22.5 bar instantaneous overload1. Recalibrate and log values with reference gauge2. Add vibration bracket and heat shielding3. Replace unit if drift persists
Intermittent signal loss, unstable contact1. Loose terminals or oxidized conductors2. Burned / carbonized microswitch contacts3. Water ingress and terminal corrosion from loose gland4. Internal wiring loose due to vibration1. 전원 분리, open cover and retighten terminals2. Cycle and test continuity repeatedly1. 단자를 다시 조이세요, clean or replace oxidized conductors2. Tighten Pg13.5 gland and check seal for IP663. Replace unit if contacts are burned
Media leakage from switch body1. PTFE tape trapped inside the thread and scoring diaphragm2. Diaphragm aging / incompatibility with process fluid3. Freeze damage, overtemperature or overpressure4. Cracked base from spanner on plastic housing1. Identify leak location: thread joint or housing seam2. Verify process pressure and temperature are within ratings1. Re-seal correctly, apply tape only on male thread2. Select wetted material variant compatible with media3. Replace unit if base or diaphragm is damaged
Water ingress and internal rusting1. Missing or loose gland seal2. Aged cover gasket, unevenly tightened cover screws3. Outdoor installation with direct spray / UV exposure1. Open cover and inspect for standing water or oxidation1. Replace gasket, tighten cover screws evenly and compress gland seal2. Fit weather shield for outdoor use
Repeated contact burnout on power-up1. Direct switching of motors / 접촉기, exceeding contact ratingXMLB contact rating: AC-15 240V 1.5A, not for high-power loads2. Unsuppressed inductive arcing1. Check load current and separate control circuit from power circuit1. Use pressure switch to drive an intermediate relay only; relay switches the load2. Fit RC snubber across inductive coils

✅ Standard Troubleshooting Sequence

  1. Process check: Confirm pressure, media and temperature are within rating; verify isolation and relief valves are open and impulse line clear
  2. 기계적 점검: 누출, 진동, mounting and tapping location
  3. Setpoint check: Verify trip and differential with certified reference gauge
  4. Electrical check: 전원 분리, test dry contact continuity, check wiring and sealing
  5. Final decision: Replace complete unit if diaphragm, spring or microswitch fails. No spare internal parts are available for XMLB.

✅ Preventive Guidelines

  1. Install pre-filter for dirty media to protect diaphragm
  2. Quarterly calibration for safety interlock circuits; 6–12 months for standard compressor / water pump service
  3. Never apply spanner force to plastic housing; only grip the hexagonal base
  4. Use intermediate relay isolation for inductive loads to extend contact life
  5. Confirm wetted material compatibility: Standard XMLB uses FKM fluoroelastomer; special versions required for aggressive media

Telemecanique Nautilus / OsiSense XM Electromechanical Pressure Switch Series Overview

메모: XMLA / XMLB / XMLC / XMLD are current main diaphragm / piston pressure and vacuum switches. Legacy XM series (XMJ, XMG, XM2JM, XMP, FYG) are discontinued and only for cross-reference. 표준 연결: G1/4 internal ISO228 thread, passive dry contact, control circuit duty, IP66

Model coding rule (XMLB010A2S11 example):

XML [시리즈] [범위] [Wetted Material] [연락하다 / 기구] [Electrical Entry] [버전]

S11 = Pg13.5 cable gland, 나사 터미널 (XMLB010A2S11); S12=M20 gland; C11=DIN43650 connector

시리즈 비교

시리즈콘택트 렌즈미분주요 특징일반적인 사용
XMLA1콜로라도Fixed differentialSingle setpoint, fixed hysteresis, 비용 효율적공기 압축기, simple alarm, single threshold protection
XMLB1콜로라도Adjustable differential단일 전환, adjustable trip+reset, scale plate (당신의 모델)Pump start-stop, compressor pressure regulation, 매끄럽게 하기 & 유압 시스템
XMLC2콜로라도Adjustable differentialTwo independent changeover contacts, dual adjustable setpointsSeparate low-pressure warning + high-pressure shutdown, 연동, pump/fan sequencing
XMLD2콜로라도Fixed differentialDual independent switch elements, each with fixed hysteresisTwo independent fixed pressure thresholds, 안전 인터록
XMLAM / XMLBM진공결정된 / 조절할 수 있는Negative pressure vacuum switch, -1…0 barVacuum handling, suction lines
  1. XMLA (Fixed Differential, 1콜로라도) 모델 목록
모델범위 (술집)비고
XMLA002A2S110.25~2.5Low pressure air / 물
XMLA004A2S110.4~4상수도, 공조
XMLA010A2S110.7~10General air compressor
XMLA020A2S111.2~20유압, medium pressure pneumatic
XMLA035A2S112.1~35Medium pressure hydraulic
XMLA070D2S114.5~70High pressure hydraulic
XMLA160D2S119~160High pressure hydraulic
XMLA300D2S1116~300Heavy-duty hydraulic
XMLA500D2S1130~500Ultra-high pressure hydraulic
XMLAM01V2S11-1~0Vacuum switch
  1. XMLB (Adjustable Differential, 1콜로라도, including XMLB010A2S11)
모델범위 (술집)비고
XMLB002A2S110.25~2.5저기압
XMLB004A2S110.4~4공조 & 상수도
XMLB010A2S110.7~10귀하의 모델, popular for compressors & 슬리퍼
XMLB020A2S111.2~20Medium pressure pneumatic / 유압
XMLB035B2S112.1~35Hydraulic power units
XMLB070D2S114.5~70High pressure hydraulic
XMLB160D2S119~160High pressure hydraulic
XMLB300D2S1116~300Heavy-duty hydraulic
XMLB500D2S1130~500Ultra-high pressure hydraulic
XMLBM02V2S11-1~0Adjustable vacuum switch
  1. XMLC (Adjustable Differential, 2CO Dual Contacts)
모델범위 (술집)비고
XMLC004B2S110.4~4Dual signal output
XMLC010B2S110.7~1010 bar dual contact, 낮은 / high pressure alarm
XMLC020B2S111.2~20Medium pressure dual output
XMLC035B2S112.1~35Hydraulic dual interlock
XMLC070D2S114.5~70High pressure dual contact
XMLC160D2S119~160High pressure hydraulic
XMLC300D2S1116~300Heavy-duty hydraulic
XMLC500D2S1130~500Ultra-high pressure hydraulic
  1. XMLD (Fixed Differential, 2CO Dual Stage)
모델범위 (술집)비고
XMLD004B2S110.4~4Dual stage fixed hysteresis
XMLD010B2S110.7~1010 bar dual stage protection
XMLD020B2S111.2~20Medium pressure dual stage
XMLD035B2S112.1~35Hydraulic safety interlock
XMLD070D2S114.5~70High pressure dual stage
  1. 단종된 레거시 모델 (Cross-reference only, 새로운 프로젝트가 아닌)

XMJ: Old single setpoint pressure switch, replaced by XMLA

XMG: Old adjustable differential switch, replaced by XMLB

XM2JM: Simple fixed differential auxiliary sensor

XMP / FYG: Old dual setpoint switch, replaced by XMLC

Most legacy XM series discontinued in 2002; stock only available in spare parts market. Prefer XMLB/XMLC for replacement.

  1. Electrical Suffix Cross Reference (Interchangeable for same range)

S11: Pg13.5 케이블 글랜드, 나사 터미널 (XMLB010A2S11 standard)

S12: M20×1.5 케이블 글랜드, 나사 터미널

C11: DIN43650 square connector (solenoid valve style)

S13: Special extended housing version

  1. Wetted Material Code Definition

에이: FKM 불소탄성체 (일반적인: 공기, 정수, 유압유, 기준)

비: NBR 니트릴 고무 (mineral oil, not for hot water)

디: 스테인레스 스틸 + FKM (유압유, elevated temperature hydraulic)

다섯: Vacuum grade sealing

  1. 빠른 선택 가이드
  2. Single trip point, fixed hysteresis → XMLA
  3. Adjustable start-stop differential (펌프 / 압축기) → XMLB (XMLB010A2S11)
  4. Two independent alarm signals (low warning + high shutdown) → XMLC
  5. Two independent thresholds, no differential adjustment required → XMLD
  6. Negative vacuum pressure → XMLAM / XMLBM

이전: