(Part No.: 153495) LRMA-QS-4 is a direct-acting piston mini pressure regulator from Festo LRMA series. It is fitted with QS-4 push-in connectors on both ends and an integrated pressure gauge for precise pressure regulation on pneumatic branch circuits. It is a compact secondary-side pressure regulator, now discontinued by Festo; only surplus stock and used spare ...

  • Product Details

(Part No.: 153495)

LRMA-QS-4 is a direct-acting piston mini pressure regulator from Festo LRMA series. It is fitted with QS-4 push-in connectors on both ends and an integrated pressure gauge for precise pressure regulation on pneumatic branch circuits. It is a compact secondary-side pressure regulator, now discontinued by Festo; only surplus stock and used spare parts are available on the market.

  1. Type Code Explanation

LRMA: Series code, compact mini pressure regulator with built-in pressure gauge and secondary venting function

QS: Festo QS push-in quick connector

4: For PU/PA tubing with outer diameter 4 mm

Distinction: LRMA-M5-QS-4 (153488) has an M5 thread inlet and QS-4 outlet; LRMA-QS-4 (153495) has QS-4 push-in ports on both sides without any threaded connection.

  1. Working Principle

It adopts a direct-acting piston structure with secondary venting (relief-type regulator):

  1. High-pressure compressed air enters port 1. Internal piston and spring balance to stabilize output pressure.
  2. If downstream load pressure exceeds the set value, the built-in vent port automatically exhausts air to maintain constant outlet pressure.
  3. It keeps stable pressure regardless of upstream pressure fluctuation and downstream air consumption change.
  4. The top knurled adjustment knob comes with a lock nut to fix pressure setting and prevent pressure drift caused by vibration.
  5. Key Technical Specifications
ItemSpecification
Part Number153495
StructureDirect-acting piston regulator with secondary venting
Pneumatic PortsPort 1: QS-4; Port 2: QS-4 (double-ended QS-4 push-in)
Pressure Adjustment Range1 ~ 8 bar
Max Inlet Pressure0 ~ 9 bar
Standard Nominal Flow50 l/min
MediumCompressed air (lubricated or non-lubricated; ISO8573-1:2010 [7:-:-])Festo
Ambient Temperature0 ℃ ~ +60 ℃
Housing MaterialGlass fibre reinforced PBT
Adjustment MechanismKnurled knob + lock nut (pressure locking)
Pressure GaugeIntegral built-in gauge for real-time pressure reading
MountingFixed via through-hole; any mounting position
Connector FeatureQS fitting can rotate 360° for flexible piping layout
Product StatusDiscontinued, no new production
RepairabilityNon-repairable; replace the whole unit once failed
  1. Product Features
  2. Ultra-compact size: Ideal for narrow-space branch regulation, near valve islands, jigs, fixtures and small actuators.
  3. Relief pressure stabilization: Automatically exhausts excess downstream pressure, perfect for suction cups, low-pressure cylinders and precision air-blow circuits.
  4. Tool-free quick connection: Double-ended QS-4 fittings allow fast tubing insertion and 360° pipe rotation.
  5. Vibration-proof locking: Lock nut secures set pressure to avoid drift under machine vibration.
  6. Built-in pressure gauge: No extra external gauge required; direct visual pressure reading.
  7. Oil-free air compatible: Works with non-lubricated compressed air for electronics, food and precision assembly applications.
  8. Typical Applications

Independent pressure regulation for automation jigs, small cylinders and pneumatic grippers

Pressure stabilization for air blowing, dust removal and static elimination nozzles

Positive pressure circuits for vacuum suckers and miniature pneumatic actuators

Secondary pressure regulation on valve island outlets for multi-circuit independent pressure control

Small test benches, laboratory pneumatic loops and micro-pneumatic units in semiconductor equipment

  1. Installation & Commissioning Guidelines
  2. Airflow direction: Follow the arrow mark on the valve body (IN → OUT); reverse installation is prohibited.
  3. Tubing: Only use PU/PA tubing with OD 4 mm; push tubing fully into the fitting. Press the release ring before pulling out the tube.
  4. Pressure setting: Loosen the lock nut first. Turn the knob clockwise to raise pressure and counter-clockwise to lower pressure. Tighten the lock nut after setting to lock the value.
  5. Air source pretreatment: Install a filter upstream to prevent dirt from jamming the piston.
  6. Mounting: Secure the valve with screws through the through-hole; vertical, horizontal and upside-down installation are all allowed.
  7. Replacement & Spare Part Notes

Model 153495 is discontinued. Not recommended for new projects; select alternatives below:

Same-series alternative: LRMA-1/8-QS-4 (153489), with R1/8 thread inlet and QS-4 outlet

New-generation compact regulator: Festo LRPS series mini pressure regulator (same compact size with upgraded performance)

Sourcing: Only surplus stock and second-hand used units available. Inspect before purchase: intact pressure gauge, no air leakage, free piston movement without jamming.

  1. Troubleshooting
  2. Cannot build up pressure: Insufficient inlet air pressure, pipe leakage or stuck piston.
  3. Unstable pressure / pressure drift: Loose lock nut or aged internal seals (no separate seal kits for this obsolete model).
  4. Pressure keeps rising after shutdown: Damaged internal sealing or blocked vent channel.
  5. No gauge reading: Broken pressure gauge or blocked internal air passage.

Festo LRMA-QS-4 Mini Pressure Regulator (SEO Product Page for bestcontactor.com)

Category: Direct-acting Piston Mini Pressure Regulator | Brand: Festo | Series: LRMA Compact Regulator | Port: QS-4 push-in for OD4 mm PU tubing

  1. Type Code Definition

LRMA: Compact pressure regulator, direct-acting piston type with secondary venting (auto exhaust to stabilize load pressure)

QS: Festo QS push-in quick fitting

QS-4: Outlet push-in port for OD4 mm pneumatic tubing

Sub-series difference: LRMA-M5-QS-4 / LRMA-1/8-QS-4 / LRMA-1/4-QS-4 differ only in inlet thread. All belong to the LRMA-QS-4 port branch. These old sub-models are end-of-life; most orders are for equipment maintenance and replacement.

  1. Main Technical Parameters

Structure: Direct-acting piston regulator, straight air supply with secondary relief venting

Medium: Filtered compressed air (lubricated / oil-free air; 40μm pre-filter recommended)

Inlet Pressure: 0 ~ 9 bar

Regulation Range: 1 ~ 8 bar

Standard Nominal Flow: 36 L/min for M5 thread version; 59 L/min for R1/8 thread version

Ambient Temperature: 0 ℃ ~ +60 ℃

Mounting: Through-hole screw fixing; any installation position; 360° rotatable adjustment knob

Adjustment: Knurled screw with lock nut to lock pressure against vibration drift

Material: Glass fibre reinforced PBT housing, NBR rubber seals

Weight: Approx. 28–54.5 g, ultra-small miniature valve body

Optional: Matched pressure gauge for direct outlet pressure reading

  1. Application Scope

LRMA-QS-4 is a mini regulator designed for single-point pressure stabilization in confined spaces. Not suitable for main air line large-flow regulation. It is exclusively used for branch circuit secondary pressure control:

  1. Separate pressure control for automation fixtures, miniature pneumatic fingers and small bore cylinders
  2. Air source stabilization upstream of flow sensors and pressure transmitters on test equipment
  3. Pneumatic auxiliary circuits in 3C assembly, semiconductor production and laboratory test benches
  4. Small pneumatic actuator branches on textile and packaging machinery
  5. Pneumatic spare parts for complete sets of equipment exported to Central Asia and Uzbekistan

Selection Tip: Choose LR series for main air supply large-flow regulation; select LRLL differential pressure valves for constant pressure difference control; do not mix up with LRMA.

  1. Installation & Commissioning Steps
  2. Air pretreatment: Install a filter on the upstream side to avoid oil and dust scratching piston seals and shortening service life. Do not install directly on unfiltered air lines.
  3. Airflow direction: Port 1 (IN) = inlet; Port 2 (OUT) = load side. Strictly follow the arrow on the valve body; reverse connection is forbidden.
  4. Pressure setting: Unlock the lock nut first. Clockwise rotation increases pressure; counter-clockwise rotation decreases pressure. Lock the nut tightly after setting to prevent vibration-induced pressure change.
  5. Tubing matching: QS-4 fitting only fits OD4 mm tubing. Cut the tube flat and push fully into the fitting. Press the blue release ring before pulling out the tube; hard pulling will damage the connector.
  6. Maintenance cycle: Clean the piston assembly every 6–12 months under clean air conditions; inspect seals every 3–6 months in dusty environments.
  7. Fault Troubleshooting Table
Fault PhenomenonRoot CauseSolution
Output pressure drifts continuously, poor stabilizationDust in piston chamber, aged NBR seals; loose lock nutDisassemble and clean piston parts, replace seals; tighten lock nut after pressure setting
Pressure cannot reach the set upper limitInsufficient inlet pressure; stuck pistonEnsure inlet pressure is at least 0.5 bar higher than target output pressure; disassemble and clean the valve body
Continuous air exhaust from the relief portBackpressure from downstream load, broken seals, foreign matter stuck on valve seatCheck for backpressure in downstream circuit; clean valve seat or replace the whole valve
Air leakage at push-in fittingCropped tube end, incomplete insertion, worn fitting clipCut PU tube flat and reinsert firmly; replace the valve if the fitting is damaged
Adjustment knob spins freely with no pressure changeDisconnected internal adjusting pin or seized pistonReplace the spare part; forced disassembly is not recommended
  1. Alternative Replacement Options (New & Cross-Brand Substitutes)

After LRMA old part numbers were discontinued, Festo’s official upgraded replacement is the VRPA series mini pressure regulator (VRPA-LM-M5-QS-4 / VRPA-LM-1/8-QS-4), with higher flow rate and compatible mounting dimensions for simple retrofitting.

  1. Festo same-series substitute: LR-QS series (same working principle with wider flow options)
  2. Cross-brand alternatives:

Airtac: AR1000-M5 (mini regulator with 4mm port)

SMC: ARJ210-M5 (relief-type mini regulator, direct equivalent to LRMA)

Replacement Checklist: pressure range, rated flow, mounting hole pitch, inlet thread and tube size. For export projects, prioritize original Festo VRPA for best parameter consistency.

LRMA-QS-4 is a classic mini pressure regulator from Festo, widely used for end-of-line pneumatic pressure stabilization on European and Central Asian non-standard automation production lines. bestcontactor supplies genuine surplus Festo LRMA series regulators, plus obsolete part sourcing, technical confirmation for replacements, drawing parameter verification, English/Spanish technical documents. We support bulk foreign trade orders and small maintenance spare part orders.

Festo Mini Pressure Regulators LR / LRMA / LRL / LRLL Full Model & Part Number List

Note: LRMA = with built-in pressure gauge; LR = without pressure gauge; LRL / LRLL = differential pressure regulators for constant pressure difference. All models are direct-acting piston relief-type valves. LR/LRMA/LRL/LRLL have been discontinued; only surplus stock and used spare parts are available. Pressure regulation range: 1 ~ 8 bar for all models.

  1. LRMA Series (With Pressure Gauge, Standard Mini Regulator; LRMA-QS-4 belongs here)
ModelPart No.Port DescriptionNominal Flow (l/min)
LRMA-M5-QS-4153488Inlet M5 thread, outlet QS-436
LRMA-M5-QS-6153490Inlet M5 thread, outlet QS-642
LRMA-1/8-QS-4153489Inlet R1/8 thread, outlet QS-459
LRMA-1/8-QS-6153491Inlet R1/8 thread, outlet QS-675
LRMA-1/8-QS-8153493Inlet R1/8 thread, outlet QS-887
LRMA-1/4-QS-6153492Inlet R1/4 thread, outlet QS-696
LRMA-1/4-QS-8153494Inlet R1/4 thread, outlet QS-897
LRMA-QS-4153495QS-4 push-in on both ends (your model)50
LRMA-QS-6153496QS-6 push-in on both ends76
LRMA-QS-8153497QS-8 push-in on both ends124
  1. LR Series (Without Pressure Gauge, Same Body Size)
ModelPart No.Port Configuration
LR-M5-QS-4153532M5 → QS-4
LR-M5-QS-6153533M5 → QS-6
LR-1/8-QS-4153534R1/8 → QS-4
LR-1/8-QS-6153535R1/8 → QS-6
LR-1/8-QS-8153536R1/8 → QS-8
LR-1/4-QS-6153537R1/4 → QS-6
LR-1/4-QS-8153538R1/4 → QS-8
LR-QS-4153540QS-4 on both ends
LR-QS-6153541QS-6 on both ends
LR-QS-8153542QS-8 on both ends
  1. LRL Series (Differential Pressure Regulator, Top Outlet, Constant Pressure Difference)
ModelPart No.Port
LRL-M5-QS-4153510M5 → QS-4
LRL-M5-QS-6153512M5 → QS-6
LRL-1/8-QS-4153511R1/8 → QS-4
LRL-1/8-QS-6153513R1/8 → QS-6
LRL-1/8-QS-8153515R1/8 → QS-8
LRL-1/4-QS-6153514R1/4 → QS-6
  1. LRLL Series (Differential Pressure Regulator, Side Outlet, Constant Pressure Difference)
ModelPart No.Port
LRLL-M5-QS-4153498M5 → QS-4
LRLL-M5-QS-6153500M5 → QS-6
LRLL-1/8-QS-4153499R1/8 → QS-4
LRLL-1/8-QS-6153501R1/8 → QS-6
LRLL-1/8-QS-8153503R1/8 → QS-8
LRLL-1/4-QS-6153502R1/4 → QS-6
  1. Quick Series Identification
  2. LRMA: Standard pressure regulation + built-in pressure gauge (most popular for jigs, suction cups and air-blow branches)
  3. LR: Standard pressure regulation without gauge, lower cost
  4. LRL / LRLL: Differential pressure valves to maintain constant inlet-outlet pressure difference for flow compensation circuits; not for general pressure regulation
  5. Port suffix explanation: M5/R1/8/R1/4 = threaded inlet; QS-4/6/8 = push-in tubing port; double QS-xx means push-in connectors on both ends
  6. New project selection recommendation: LRPS new-generation mini precision pressure regulator (official replacement for obsolete LRMA series)
  7. Purchasing & Inspection Notes

All models are relief-type with automatic air exhaust when downstream pressure rises; lockable knob prevents pressure shift under vibration.

No separate seal repair kits available; replace the whole valve once failed.

Inspection checklist for surplus/used units: no stuck pressure gauge pointer, no external air leakage, fully functional lockable adjustment knob.

Prev:

Next:

Leave a Reply

Leave a message