SK-R1-FAN1-F8: Cooling Fan Kit for Rockwell PowerFlex 750 Series SK-R1-FAN1-F8 is an inverter cooling fan kit manufactured by Allen-Bradley (Rockwell Automation), designed as an internally mounted spare part specifically for PowerFlex 750 Series Frame 8 AC drives. Core Specifications & Features Parameter Description Brand Allen‑Bradley (Rockwell Automation) Product Type Fan Kit, Inverter Heat Sink Applicable ...

  • Product Details

SK-R1-FAN1-F8: Cooling Fan Kit for Rockwell PowerFlex 750 Series

SK-R1-FAN1-F8 is an inverter cooling fan kit manufactured by Allen-Bradley (Rockwell Automation), designed as an internally mounted spare part specifically for PowerFlex 750 Series Frame 8 AC drives.

Core Specifications & Features

ParameterDescription
BrandAllen‑Bradley (Rockwell Automation)
Product TypeFan Kit, Inverter Heat Sink
Applicable EquipmentPowerFlex 750 Series Frame 8 AC Drive
MountingInternal Mount
Lifecycle StatusACTIVE
Main FunctionProvides forced convection cooling for the inverter section of the drive, preventing overheating of power components
Applicable StandardsC-TICK, KC
Typical PriceApproximately US$3,780–3,835 per set (varies by distributor)

Model Interpretation

SK-R1: Prefix for cooling-related components in the Rockwell PowerFlex series

FAN1: Single-fan configuration (SK-R1-FAN2-F8 is the dual-fan version)

F8: Fits Frame 8 size drives

Applications

This fan kit is a critical cooling component for PowerFlex 750 Series Frame 8 variable frequency drives, used in high-power industrial automation applications including:

Large motor speed control

Heavy machinery drive systems

Industrial production line automation

Energy and infrastructure projects

Notes

  1. This is an original spare part; installation and maintenance should be performed by qualified technicians.
  2. Must be used with exact matching PowerFlex 750 Series Frame 8 drive models.
  3. Regularly inspect fan operation to ensure proper cooling system function and extend drive service life.

SK-R1-FAN1-F8 vs SK-R1-FAN2-F8

Detailed Parameter Comparison & Frame 8 Drive Compatibility List

  1. Core Parameter Comparison
ParameterSK‑R1‑FAN1‑F8SK‑R1‑FAN2‑F8Key Difference
Full Product NamePowerFlex 750 Inverter Heat Sink Fan KitPowerFlex 750 Internal Stirring Fan Kit with TrayFunctional purpose: primary cooling vs auxiliary airflow circulation
Core FunctionProvides forced convection cooling for inverter power modules, preventing overheating of IGBTs and other devicesOptimizes internal airflow distribution, eliminates local hot spots, and assists the main cooling systemCooling priority: FAN1 = primary, FAN2 = auxiliary
Fan ConfigurationSingle large centrifugal fan (R3G310‑AN48‑78)Two small stirring fans with mounting trayDifferent fan quantity and type
Air Volume (CFM)Approx. 1,200–1,400 CFM (ebmpapst R3G310 series, Germany)Approx. 2 × 200 CFM (dual fan combination)FAN1 has significantly higher airflow
Power ConsumptionApprox. 470W, 3A, 230V ACApprox. 2 × 30W, 0.25A × 2, 24V DCFAN1 has higher power and different voltage rating
Mounting LocationDedicated position for inverter heat sinkGeneral internal mounting position with trayDifferent mounting location and fixing method
WeightApprox. 9.5 kg (20.94 lb)Approx. 3.2 kg (7.05 lb)FAN1 is heavier due to large fan
Frame CompatibilityFrame 8–10 (primarily Frame 8)Frame 8 onlyFAN1 covers more frames
Typical PriceUS$3,780–3,835/setUS$1,200–1,500/setFAN1 is more expensive
Lifecycle StatusACTIVEACTIVEBoth are currently available spares
Applicable StandardsC-TICK, KCC-TICK, KCSame electrical safety compliance
MountingInternal MountInternal Mount with trayFAN2 is simpler to install
  1. Power Ratings & Typical Models for Frame 8 Drives

2.1 Applicable Power Range

PowerFlex 750 Series Frame 8 drives cover the following power ratings (varies by voltage):

VoltageRated Power RangeRated Current Range
400V AC450kW–560kW (ND/HD)770A–850A
480V AC400kW–500kW (ND/HD)740A–820A
690V AC375kW–450kW (ND/HD)460A–520A

2.2 Compatible Drive Model List

SK-R1-FAN1-F8 is compatible with these PowerFlex 750 Series Frame 8 drives:

PowerFlex 753 Series (20F prefix)

20F11NDxxxxNNNNNN (Standard, 400/480V)

20F11TDxxxxNNNNNN (With DC Terminals, 400/480V)

20F11LDxxxxNNNNNN (Light Duty, 400/480V)

20F11HDxxxxNNNNNN (Heavy Duty, 400/480V)

PowerFlex 755 Series (20G prefix)

20G11NDxxxxNNNNNN (Standard, 400/480V)

20G11TDxxxxNNNNNN (With DC Terminals, 400/480V)

20G11LDxxxxNNNNNN (Light Duty, 400/480V)

20G11HDxxxxNNNNNN (Heavy Duty, 400/480V)

20G1ABDxxxxNNNNNN (Common converter module, Frame 8–10)

20G1ALDxxxxNNNNNN (Common inverter module, Frame 8–10)

PowerFlex 758 Series (20P prefix, high performance)

20P11NDxxxxNNNNNN (Standard, 400/480V)

20P11TDxxxxNNNNNN (With DC Terminals, 400/480V)

General Rule: All Frame 8 PowerFlex 750 drives (753/755/758) are compatible with SK-R1-FAN1-F8; some Frame 9–10 models also apply. SK-R1-FAN2-F8 is designed exclusively for Frame 8 and is not compatible with Frame 9–10.

  1. Selection & Application Recommendations

When SK-R1-FAN1-F8 is Required

All newly installed Frame 8 drives

Drives operating under Heavy Duty (HD) or high ambient temperature (>40°C) conditions

Replacement after inverter cooling fan failure

When SK-R1-FAN2-F8 is Recommended

Local hot spots inside the drive

High altitude (>1000m) or enclosed cabinet installation

Need to improve internal airflow for better overall cooling efficiency

Installation Notes

Both can be installed together for a complete “primary cooling + auxiliary airflow” solution

Installation must be performed by qualified technicians to ensure safe electrical and mechanical connections

Disconnect power and allow heat sinks to cool fully before replacement to avoid burns

Inspect fan operation and clean dust regularly (recommended every 6 months)

Complete List of Cooling Fan Models

for Rockwell PowerFlex 750 Series

Below is the complete official list of cooling fan kits for the PowerFlex 750 series, categorized by function type and frame size, including the SK-R1 (internal core cooling components) and SK-R9 (external cooling fan kits) series.

  1. SK-R1 Series: Internal Core Cooling Fan Kits

1.1 Frame 8 Specific Core Cooling Fans

ModelFull NameDescriptionFrameLifecycle
SK‑R1‑FAN1‑F8PowerFlex 750 Inverter Heat Sink Fan KitPrimary cooling: forced convection for inverter power modules, fits Frame 8–10, includes large centrifugal fan (R3G310‑AN48‑78)Frame 8 (Frame 9–10 compatible)ACTIVE
SK‑R1‑FAN2‑F8PowerFlex 750 Internal Stirring Fan KitAuxiliary cooling: optimizes internal airflow, eliminates hot spots, includes mounting trayFrame 8ACTIVE
SK‑R1‑FAN2H‑F8PowerFlex 750 Internal Stirring Fan KitAuxiliary cooling: high‑performance internal stirring fan for improved circulationFrame 8ACTIVE
SK‑R1‑FAN4‑F8PowerFlex 750 IP54 Blower Assembly KitProtected cooling: blower system for IP54 environmental ratingFrame 8ACTIVE
SK‑R1‑FANH1‑F8PowerFlex 750 Fan Harness KitWiring component: dedicated harness for cooling fan electrical connectionFrame 8ACTIVE
SK‑R1‑FUSEFAN‑F8PowerFlex 750 Converter Input Fuse Stirring FanLocal cooling: stirring fan designed specifically for the converter input fuse areaFrame 8ACTIVE

1.2 Frame 9–10 Specific Cooling Fans

ModelFull NameDescriptionFrameLifecycle
SK‑R1‑FAN1‑F9PowerFlex 750 Inverter Heat Sink Fan KitFrame 9 primary cooling fan, same function as F8 with matched dimensionsFrame 9ACTIVE
SK‑R1‑FAN1‑F10PowerFlex 750 Inverter Heat Sink Fan KitFrame 10 primary cooling fan, maximum airflow configurationFrame 10ACTIVE
SK‑R1‑OCARTFAN‑F9PowerFlex 750 FR9 Option Slot Fan Tray KitOption area cooling: directed cooling for Frame 9 option slot (including reactors)Frame 9ACTIVE
SK‑R1‑OCARTFAN‑F10PowerFlex 750 FR10 Option Slot Fan Tray KitOption area cooling: directed cooling for Frame 10 option slotFrame 10ACTIVE
  1. SK-R9 Series: External Cooling Fan Kits (By Protection Rating)

2.1 NEMA Type 1 / IP20 External Cooling Fans (Frame 1–7)

ModelFull NameDescriptionFrameLifecycle
SK‑R9‑FAN11‑F1PowerFlex 750 Type 1 Heat Sink Fan KitBasic external cooling for Frame 1, NEMA 1 ratedFrame 1ACTIVE
SK‑R9‑FAN11‑F2PowerFlex 750 Type 1 Heat Sink Fan KitBasic external cooling for Frame 2, NEMA 1 ratedFrame 2ACTIVE
SK‑R9‑FAN11‑F3PowerFlex 750 Type 1 Heat Sink Fan KitBasic external cooling for Frame 3, NEMA 1 ratedFrame 3ACTIVE
SK‑R9‑FAN11‑F4PowerFlex 750 Type 1 Heat Sink Fan KitBasic external cooling for Frame 4, NEMA 1 ratedFrame 4ACTIVE
SK‑R9‑FAN11‑F5APowerFlex 750 Type 1 Heat Sink Fan KitBasic external cooling for Frame 5, NEMA 1 ratedFrame 5ACTIVE
SK‑R9‑FAN11‑F6PowerFlex 750 Type 1 Heat Sink Fan KitBasic external cooling for Frame 6, NEMA 1 ratedFrame 6ACTIVE
SK‑R9‑FAN11‑F7APowerFlex 750 Type 1 Heat Sink Fan KitBasic external cooling for Frame 7, NEMA 1 ratedFrame 7ACTIVE

2.2 NEMA Type 4X/12 / IP66/54 Protected External Cooling Fans (Frame 4–7)

ModelFull NameDescriptionFrameLifecycle
SK‑R9‑FAN14‑F45PowerFlex 750 Type 4X Heat Sink Fan KitProtected external cooling for Frame 4–5, NEMA 4X/12 ratedFrame 4–5ACTIVE
SK‑R9‑FAN14‑F6PowerFlex 750 Type 4X Heat Sink Fan KitProtected external cooling for Frame 6, NEMA 4X/12 ratedFrame 6ACTIVE
SK‑R9‑FAN14‑F7APowerFlex 750 Type 4X Heat Sink Fan KitProtected external cooling for Frame 7, NEMA 4X/12 ratedFrame 7ACTIVE
  1. Other Related Cooling Components
ModelFull NameDescriptionFrameLifecycle
SK‑R9‑FAN2‑F23PowerFlex 750 Internal Fan KitGeneral internal cooling for Frame 2–3Frame 2–3ACTIVE
SK‑R9‑FAN2‑F45PowerFlex 750 Internal Fan KitGeneral internal cooling for Frame 4–5Frame 4–5ACTIVE
SK‑R1‑OCARTFAN‑F9PowerFlex 750 FR9 Option Slot Fan Tray KitDirected cooling for Frame 9 option slot (including reactors)Frame 9ACTIVE
SK‑R1‑OCARTFAN‑F10PowerFlex 750 FR10 Option Slot Fan Tray KitDirected cooling for Frame 10 option slotFrame 10ACTIVE
  1. Model Naming Convention

PowerFlex 750 cooling fan models follow a unified coding system:

PrefixMain IdentifierSuffixMeaning
SK‑R1-FAN[number]-F[frame]-[variant]Internal core cooling components; FAN1 = primary fan, FAN2 = stirring fan, FAN4 = IP54 blower, F[number] = frame size
SK‑R9-FAN[number]-F[frame]-[variant]External cooling fan kits; FAN11 = NEMA Type 1, FAN14 = NEMA Type 4X, F[number] = frame size
  1. Selection & Application Guide
  2. Primary cooling fan is mandatory: All new PowerFlex 750 drives must be equipped with the corresponding frame-matched SK-R1-FAN1-Fx (internal primary) or SK-R9-FAN11-Fx (external primary) fan.
  3. Auxiliary cooling recommendation: For high ambient temperature (>40°C), high altitude (>1000m), or enclosed cabinet installations, add SK-R1-FAN2-Fx series stirring fans.
  4. Protection rating matching: For outdoor or dusty environments, select SK-R9-FAN14-Fx-series NEMA 4X protected fans.
  5. –Frame compatibility–: SK-R1-FAN1-F8 is compatible with Frame 8–10; all other models are frame-specific.

 