 INVT-CHF100A-055G-075Tabela de referência rápida para seleção do conversor de frequência P-4 - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

NotíciasNotícias comerciais

INVT-CHF100A-055G-075Tabela de referência rápida para seleção do conversor de frequência P-4

INVT-CHF100A-055G-075P-4 Frequency Converter Selection Quick Reference Table

ModuleDetails
Informações BásicasBrand: INVT
Série: CHF100A Vector General-Purpose Type
Model Definition: 055G = 55kW Standard Load / 075P = 75kW Heavy Load
Voltage Class: Three-phase 380-415V AC (50/60Hz)
Protection Rating: IP20 (Cabinet Installation)
Método de resfriamento: Resfriamento de Ar Forçado
Core Electrical ParametersRated Input Voltage: 380-415V e (Fluctuation ±15%)
Potência de saída nominal: 55KW (Padrão) / 75KW (Heavy Load)
Rated Output Current: 105UM (Padrão) / 135UM (Heavy Load)
Output Frequency Range: 0.00-600.00Hz (Accuracy ±0.01Hz)
Control Mode: Controle vetorial sem sensor (SVC), Controle V/F, Controle de Torque
Capacidade de sobrecarga: 150% for 1min (Padrão); 120% for 1min (Heavy Load)
Terminal Definitions▶ Main Circuit Terminals
R/L1, S/L2, T/L3: Three-phase Power Input
Você, V, C: Frequency Converter Output (Connected to Motor)
Educação Física: Grounding Terminal
▶ Control Circuit Terminals
DI1-DI9: Entrada Digital (Configurable for Multi-speed, Start/Stop, etc.)
DO1-DO6: Digital Output (Fault, Running Signal, etc.)
AI1/AI2: Entrada Analógica (0-10V/4-20mA)
AO1/AO2: Saída Analógica
RS485: Communication Interface (Modbus RTU)
Potência do motor aplicávelStandard Load (Type G): Suitable for 55kW Three-phase Asynchronous Motor
Heavy Load (Type P): Suitable for 75kW Three-phase Asynchronous Motor
Torque inicial: 0.5Hz / 150% Rated Torque (SVC Mode)
Cenários típicos de aplicação1. Fans & Pumps: Boiler Induced Draft Fans, Central Air Conditioning Water Pumps, Cooling Tower Fans
2. Industrial Machinery: Air Compressors, Máquinas de moldagem por injeção, Printing & Packaging Equipment
3. Building Materials & Metallurgy: Belt Conveyors, Ball Mill Auxiliary Systems
4. Others: Mining Machinery, Sewage Treatment Equipment
Key Selection Tips1. Load Matching: Select Type G parameters for fans/pumps; select Type P parameters for compressors/extruders
2. Environmental Derating: For every 1℃ rise above 40℃, reduce rated current by 1%, maximum operating temperature 50℃
3. Recommended Accessories: Input Reactors (Harmonic Suppression), Braking Units (High-inertia Loads), Extended Operation Panels
4. Communication Expansion: Supports PROFIBUS-DP / DeviceNet Fieldbuses