LUST-CM-DPV1.3.0: Módulo de comunicação LUST PROFIBUS‑DP
(PROFIBUS-DP Communication Module)
CM-DPV1.3.0 is a PROFIBUS-DPV1 communication module designed by LUST (later acquired by Lenze) specifically for C-line series drives. Below are the complete technical specifications and functional features.
- Informações Básicas
Modelo: CM-DPV1.3.0 (also marked as CM-DPV1,3.0)
Tipo de produto: PROFIBUS-DP Slave Communication Module (supports DPV1 extension protocol)
Applicable Drives: CDA3000 Inverter, CDD3000 Servo Controller, CDE/CDB3000 Position Controller, CTC3000 Direct Drive Controller
Software Version: Commonly V2.25-00 (upgradable via DriveTop)
Replacement Model: CM-DPV1.3.1 (hardware compatible, software optimized)
Lenze Replacement: EMF2177IB (fully functionally compatible)
- Especificações Elétricas
| Item | Especificação |
| Tensão de alimentação | 18–30 V DC (powered by drive backplane) |
| Max. Operating Current | 0.25 UM |
| Interface de comunicação | PROFIBUS-DP (9‑pin D‑sub, compliant with EN 50170) |
| Baud Rate | 9.6 kbps / 19.2 kbps / 45.45 kbps / 93.75 kbps / 187.5 kbps / 500 kbps / 1.5 Mbps / 3 Mbps / 6 Mbps / 12 Mbps (auto‑detection) |
| Slave Address Range | 1–125 (set by DIP switches S1/S2 or parameter 582‑PBADR) |
| Process Data (PZD) | Input: máx.. 244 bytes; Output: máx.. 244 bytes |
| Acyclic Data (PKW/DPV1) | Supports parameter read/write, diagnostics, firmware upload |
| Classe de Proteção | IP20 (installed inside the drive) |
| Temperatura operacional | 0–55 °C |
| Temperatura de armazenamento | -25–+70 °C |
| Dimensões | Aprox.. 90 × 90 × 30 milímetros (for C-line communication slot) |
| Peso | Aprox.. 0.16 kg |
- Functions and Protocol Features
- DPV1 Protocol Support
Cyclic data exchange (PZD): real-time control word, setpoint, status word, actual value
Acyclic data exchange (PKW): parameter read/write, diagnostics, firmware update
Extended diagnostics: detailed network/module/drive status, fault codes
- Data Structure
EasyDrive Mode: standard PZD structure (control word / status word + setpoint / actual value)
ProfiDrive Mode: compliant with PROFIdrive profile, suitable for standard PLC configuration
- Funções de diagnóstico
Bus status, module status, communication errors, drive faults
Supports PROFIBUS standard diagnostic messages and extended diagnostics
- Configuration Methods
Hardware: address setting via DIP switches, X13 interface coding
Software: parameter configuration via LUST DriveTop / Lenze Engineer, GSD file configuration
GSD File: LUST08E9.GSD (standard version)
- Instalação e Compatibilidade
Local de instalação: Dedicated communication slot for C-line drives (no extra wiring needed)
Compatibilidade: Hardware compatible with CM-DPV1.3.1, direct replacement
Configuration Tools: DriveTop (LUST), Engineer (Lenze)
Supported Systems: Mainstream PROFIBUS masters such as Siemens, Schneider, ABB
- Aplicações Típicas
Automated production lines, robot systems, packaging machinery, equipamento de impressão, material handling
Industrial automation systems requiring PROFIBUS-DP centralized control, parameterization and diagnostics
Contator,disjuntor,inversor solar,medidor elétrico,baterias solares