Pentronic 5810080-001 Sensor de temperatura - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 Pentronic 5810080-001 Sensor de temperatura - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Notícias comerciais

Pentronic 5810080-001 Sensor de temperatura

Marca: Pentronic (Suécia), a Nordic manufacturer of high-precision sensores de temperatura. O 5810080 series is an assembled industrial Pt100 Resistance Temperature Detector (IDT). It is often mistakenly referred to as a thermocouple in the industry; this distinction is critical.

  1. Explicação do código do modelo

5810080: Série de produtos, assembled industrial platinum RTD with terminal head and protection thermowell

-001: Versão / construction suffix, representing single Pt100 element, Precisão classe A, base version with standard thermowell material, probe length and thread specification

Other variants within the series include 5810080-002 e 5810080-003, commonly dual Pt100 elements, alternative probe lengths or pressure ratings.

  1. Especificações Técnicas Principais
ItemEspecificação
Elemento de detecçãoPt100 Platinum RTD (compliant with IEC60751)
Classe de PrecisãoClasse A
Faixa de temperatura-200℃ ~ +500℃ (depends on thermowell material)
Configuração de fiaçãoStandard 4-wire (3-wire optional). The 4-wire design eliminates lead resistance error and is preferred for high-precision measurement
Thermowell Material316L aço inoxidável (padrão); Hastelloy or Titanium optional for highly corrosive media
Probe ConstructionSolid mineral-insulated / drilled protection tube, vibration-resistant structure (Pentronic thermally conductive filling for faster response)
Terminal HeadAluminium waterproof head, IP65; built-in temperature transmitter optional (4-20saída mA)
MontagemThreaded installation (G1/2, M20×1.5 commonly used), compatible with protection thermowell
Tempo de respostat0.5: aprox.. 2~8s (in liquid media, subject to probe diameter)
SILSIL2 loop assessment available (dual-element version 5810080-002)
  1. Recursos principais
  2. Excellent stability: Class A platinum wire with annual drift as low as 0.05℃, suitable for long-term continuous process measurement
  3. Vibration-resistant construction: Internal metal filling reduces air gaps, withstands vibration for temperature measurement on compressor, pump and turbine casings
  4. Replaceable insert: Sensing element is a removable insert. Sensor core can be replaced without removing the thermowell, cutting downtime maintenance cost
  5. Corrosion-resistant options: Custom Hastelloy and Monel thermowells available for corrosive chemical service
  6. Acessórios opcionais: Built-in HART temperature transmitter providing direct 4–20mA signal to DCS/PLC
  7. Cenários típicos de aplicação
Pentronic 5810080-001 Sensor de temperatura

Pentronic 5810080-001 Sensor de temperatura

Thermal power, óleo & gás, químico, paper and pharmaceutical industries; temperature measurement of pipelines, equipment casings and tank media; high-precision temperature acquisition for TSI and process control loops.

Frequently paired with Bently Nevada TSI systems for unit temperature monitoring.

  1. Instalação & Diretrizes de Comissionamento
  2. Instalação: Protection thermowell is recommended for online replacement. Probe insertion depth ≥ 8~10 times thermowell inner diameter to ensure accurate temperature reading
  3. Fiação: 4-wire Pt100 with two excitation wires and two measurement wires. Must not be used with thermocouple extension wires
  4. Blindagem: Cable shield single-point grounded inside terminal head to avoid common-mode interference; route away from power cables
  5. Calibração: Calibrate resistance values against IEC60751 using dry block calibrator or constant temperature oil bath
  6. Explosion-proof versions: A partir de agora / Ex d available; certificates must be verified for hazardous area selection
  7. Common Troubleshooting Checklist
  8. Temperature fluctuation: Loose lead connections, multi-point grounding of shield, terminal loosening caused by field vibration
  9. Persistently high / low readings: Probe not fully immersed in media, fouled thermowell, excessive lead resistance (switch to 4-wire configuration)
  10. Open circuit alarm: Broken platinum wire or bending damage at root (frequently seen under vibrating conditions)
  11. Increased drift: Platinum element aging after prolonged over-temperature operation
  12. Series Alternative & Referência de seleção
ModeloConstruçãoAplicativo
5810080-001Single Pt100, Classe ASingle-point temperature measurement for general process
5810080-002Dual Pt100, Class A/ARedundant measurement, SIL2 loop
5810080-003Single element, extended probe / high-pressure thermowellDeep insertion, high-pressure pipelines