ALPHA6000M-S2R75GBRSM Mini Vector Inverter - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 ALPHA6000M-S2R75GBRSM Mini Vector Inverter - Contator,disjuntor,sensor,Codificador,CLP,Conversor

inversor solar/CLP/

ALPHA6000M-S2R75GBRSM Mini Vector Inverter

ALPHA6000M-S2R75GB; RSM is a custom suffix (not defined in standard factory manuals. It usually stands for built-in braking resistor, fitted keypad, special firmware version or RoHS custom version. Confirm the definition of RSM with your supplier before ordering.) ✅ Model Code Breakdown ALPHA6000M: ALPHA6000M series, mini open-loop current vector inverter S2: Single-phase 220V input (200~240V ...

  • Detalhes do produto

ALPHA6000M-S2R75GB; RSM is a custom suffix (not defined in standard factory manuals. It usually stands for built-in braking resistor, fitted keypad, special firmware version or RoHS custom version. Confirm the definition of RSM with your supplier before ordering.)

✅ Model Code Breakdown

ALPHA6000M: ALPHA6000M series, mini open-loop current vector inverter

S2: Single-phase 220V input (200~240 Vca)

R75: Matched motor power 0.75kW

G: General-purpose load (torque constante)

B: Unidade de frenagem integrada (supports external braking resistor)

RSM: Custom suffix (non-standard factory code)

✅ Key Electrical Specifications

Rated input: CA monofásico 220V, 50/60Hz

Saída nominal: 3-phase 0~220V

Corrente de saída nominal: 4.0UM

Modos de controle: Controle V/F, Sensorless Open-loop Vector, V/F separation

Torque inicial: 180% torque nominal a 0,5 Hz

Speed regulation range: 1:200 in vector mode; 1:100 in V/F mode

Comunicação: RS485 integrado, Modbus-RTU

Max output frequency: 0~650Hz

Capacidade de sobrecarga: 150% for 60s, 200% por 3s

Proteção: Sobrecorrente, sobretensão, subtensão, superaquecimento, sobrecarga, perda de fase, falha à terra, etc..

✅ Product Features

Compact body, small footprint, suitable for cabinets with limited installation space

AVR automatic voltage regulation, stable operation with ±20% grid voltage fluctuation

Supports motor parameter auto-tuning, strong low-frequency torque

Multiple programmable DI/DO, analog AI/AO, multivelocidade, PID, counting and other functions

Independent air channel for reliable heat dissipation. Widely used for assembly lines, fãs, bombas de água, transportadores, small machine tools and other constant-torque applications

✅ Aplicações típicas

Transportadores pequenos, máquinas de embalagem, fãs & bombas de água, linhas de produção, small extruders, máquinas para trabalhar madeira, máquinas de processamento de alimentos

✅ Replacement & Compatibilidade

Alternativa da mesma série: ALPHA6000E-S2R75GB (6000E is standard version; 6000M is mini version. Pinout and dimensions differ, not direct plug-and-play)

Domestic equivalent models: Inovance MD200, Invt GD10, Delta VFD-M single-phase 220V 0.75kW models

Full Technical Package for ALPHA6000M-S2R75GBRSM

  1. Terminais do Circuito Principal (S2R75GB, single-phase 220V)
terminalFunçãoDescrição
eu, NSingle-phase 220V inputAC200~240V power supply
+, OPTerminais do resistor de frenagemUnidade de frenagem integrada. Connect resistor between + and PB. Do NOT connect to DC negative (-)
Você, V, C3-saída de faseConnect to 3-phase 220V asynchronous motor. Never connect mains power
Educação FísicaTerra protetoraInverter and motor frame must be grounded together

Critical warning: Never connect L/N to U/V/W, this will destroy the inverter immediately; PB and + can only be connected with braking resistor, short-circuit is forbidden.

  1. Terminais do Circuito de Controle (S2R4GB ~ S2R75GB)
terminalFunçãoEspecificação
X1~X6Multi-function DI inputsContato seco, common terminal COM. Padrão de fábrica: X1 forward run, X2 reverse run
COMDI common terminal24V reference ground
24VExternal 24V DC supplyMax 100mA. Do not short to COM directly
10V+10V analog referenceMax 20mA, for potentiometer
GNDTerra analógicaReference for AI/AO
AI1Entrada analógica 10~10V / 4~20mA (selected by DIP switch), 0~20mA, 250
AI2Entrada analógica 2-10V~+10V voltage input
AO1, AO2Saída analógicaConfigurable 0~10V or 4~20mA, selected by SW2 DIP switch
FAZEROpen-collector outputOpto-isolated, max 50mA, 0~50kHz pulse output
ENFRENTANDO, TB, TCSaída de reléTA-TB NC; TA-TC NO; 250VCA/2A
485+, 485-Comunicação RS485Modbus-RTU, para CLP / Conexão IHM
CLPDI source selection terminalPadrão de fábrica: PLC shorted with 24V for NPN mode; disconnect to use PNP

Common Wiring Schemes

  1. Potentiometer speed + terminal control: Potentiometer to 10V, AI1, GND; short X1-COM = forward run
  2. 485 comunicação: 485+ to A, 485to B; add termination resistor on remote side if needed
  3. Relay fault signal: TA-TC to PLC fault input
  4. Factory Reset Procedure (ALPHA6000M / 6000E compatible)
  5. Ligar, press PRG to enter parameter menu
  6. Locate P0.02 (parameter initialization)
  7. Setting options:

0: Nenhuma ação

1: Clear fault records

2: Restore factory defaults (recomendado)

  1. Confirmar, wait for auto-reset. Power cycle to take effect

Frequently used basic parameters:

P0.01: Control mode 0=V/F, 2=open-loop vector (vector recommended)

P0.07: Run command source 0=keypad, 1=terminals, 2=communication

P0.03: Frequency reference source 0=keypad, 2=AI1, 8=multi-speed, 10=PID

P0.10: Max output frequency, padrão 50Hz, up to 650Hz

⚠️ Resistance below 100Ω will damage the built-in braking transistor. Mount resistor away from other components with sufficient clearance; resistor housing must be grounded.

Fiação: Connect resistor two wires directly between + and PB, not the “-” terminal.

  1. Equivalent Replacement List (single-phase 220V 0.75kW mini vector, built-in braking unit preferred)

Observação: ALPHA6000M is mini type. Pinout and mounting holes differ from 6000E standard version, não pode ser trocado diretamente

Alternativas Domésticas

  1. Inovance MD200S0.75B (single-phase 220V, mini, built-in braking)
  2. Invt GD10-0R75-S2-B (GD10 mini series)
  3. Delta VFD007M21A (VFD-M classic small model)
  4. Sifang E310-2S0007
  5. Win-V63 0.75kW 220V single-phase

Notas de substituição

Priority check items: unidade de frenagem embutida, DI/DO quantity, AO 4-20mA support, Modbus RTU

Unidade original: entrada monofásica, 3-phase 220V output. Replacement motor must be rated 220V 3-phase, cannot drive 380V motor directly

For easy parameter migration: ALPHA6000E-S2R75GB from same brand, but larger size and different mounting holes

  1. Fault Code Quick Reference (6000M)
Código de falhaDescriçãoSolução de problemas
OCSobrecorrenteCurto-circuito do motor, falha de terra, rotor bloqueado, tempo de aceleração muito curto
AVSobretensãoDesaceleração rápida, missing braking resistor, alta tensão de rede
LVSubtensãoPerda de fase de entrada, low supply voltage, poor contact of contactor
OHSuperaquecimentoBlocked air channel, failed fan, alta temperatura ambiente
OLSobrecarga do motorOverloaded machine, incorrect motor auto-tuning
CECommunication errorReversed 485 fiação, termination resistor, mismatched address / taxa de transmissão
  1. Motor Auto-Tuning (Mandatory for Vector Mode)
  2. Set P0.01=2 (open-loop vector)
  3. Insira os dados da placa de identificação do motor: P2.00 rated power, P2.01 rated current, P2.02 rated frequency, P2.03 rated speed
  4. P2.04=1 (static auto-tuning, motor estacionário); P2.04=2 rotating auto-tuning (motor runs no-load, higher torque accuracy)
  5. Confirm and start; auto-tuning finishes automatically

ALPHA6000M Multi-speed + PID Constant Pressure Water Supply Parameter Set

For ALPHA6000M‑S2R75GB (0.75kW single-phase 220V)

Observação: Do not activate both functions at once. PID is for constant pressure water / fornecimento de ar; multi-speed is for assembly lines, packaging machines and multi-position fixed speed switching.

Esquema A: Multi-speed Control (DI speed selection, terminal start/stop)

Lógica de Controle

Command source: Terminal run

Frequency source: Multi-velocidade

DI assignment: X1 forward run, X2 reverse run, X3/X4/X5 as speed selectors (3-bit binário, até 8 velocidades)

COM is DI common terminal, NPN mode (factory PLC shorted with 24V)

Parameter List

Param No.NomeContextoObservações
P0.01Modo de controle2Open-loop vector (recomendado); 0=V/F
P0.07Run command source1Terminal control (X1 forward / X2 reverse)
P0.03Frequency reference source8Multi-speed reference
P0.10Frequência máxima50Follow motor nameplate, max 650Hz
P0.11Frequência mínima0Adjust as required
P1.00Acc time 15Unidade: é
P1.01Dec time 15Extend for frequent stopping
P3.00X1 function0Forward run
P3.01X2 function1Reverse run
P3.02X3 function12Speed selector S1
P3.03X4 function13Speed selector S2
P3.04X5 function14Speed selector S3
P4.00Multi-velocidade 010Velocidade 0 (all S1S2S3 OFF)
P4.01Multi-velocidade 115S1 ON
P4.02Multi-velocidade 220S2 ON
P4.03Multi-velocidade 325S1+S2 ON
P4.04Multi-velocidade 430S3 ON
P4.05Multi-velocidade 535S1+S3 ON
P4.06Multi-velocidade 640S2+S3 ON
P4.07Multi-velocidade 750S1+S2+S3 ON

Wiring Tips

No pressure / speed sensor required; only DI switch signals

If only 4 speeds are needed, use X3 and X4 only; X5 can be assigned to fault reset or other functions

Esquema B: PID Constant Pressure Water Supply (Ciclo fechado, 4-20mA pressure transmitter)

For small pump pressure stabilization. 4~20mA transmitter to AI1; 4mA = lower pressure, 20mA = full scale pressure

Output of this inverter is 3-phase 220V. Pump motor must be 3-phase 220V type, not 380V pump motor

Lógica de Controle

Command source: Terminal start (X1 forward run)

Frequency source: PID output

AI1: 4~20mA pressure feedback

PID setpoint: Keypad setting (or AI2 potentiometer setpoint)

Parameter List

Param No.NomeContextoObservações
P0.01Modo de controle0V/F preferred for pumps
P0.07Run command source1Terminal start X1 forward
P0.03Frequency reference source10PID reference
P0.10Frequência máxima50Pump rated frequency
P0.11Frequência mínima20Prevent dry running at low speed
P1.00Acc time10Avoid water hammer
P1.01Dec time15Pumps must not stop rapidly
P5.00PID enable1Habilitar PID
P5.01PID setpoint source0Keypad setpoint; 1=AI2 external setpoint
P5.02PID feedback source0AI1 feedback
P5.03PID proportional gain Kp30Initial value; reduce if oscillating
P5.04PID integral time Ti2Unidade: é; increase if pressure fluctuates
P5.05PID derivative time Td0Derivative unused for water supply
P5.06PID deviation limit5Fast adjustment over this deviation
P5.07PID output upper limit100Corresponds to max frequency
P5.08PID output lower limit0
P5.09PID sleep function00=disable; 1=enable sleep at low flow
P6.00AI1 type selection11=4~20mA; 0=0~10V
P6.01AI1 min value0Pressure at 4mA (MPa)
P6.02AI1 max value1Pressure at 20mA (MPa), adjust as per transmitter

Fiação

Transmissor de pressão: Powered by inverter 24V, signal+ → AI1, signal→ GND

Set AI1 DIP switch to current mode (4-20mA)

Short X1-COM to start; open to stop

PID Tuning Sequence (Importante)

  1. Disable PID first (P5.00=0), run pump manually to confirm rotation direction
  2. Confirm transmitter range: por exemplo. 0~1MPa, P6.01=0, P6.02=1.0
  3. P5.00=1 to enable PID, set target pressure on keypad e.g. 0.4MPa
  4. Solução de problemas:

Pressure oscillates: Reduce Kp (por exemplo. para 15), increase Ti

Pressure rises slowly: Increase Kp, reduce Ti

Severe overshoot: Reduce Kp, increase Ti

  1. Função dormir (P5.09=1): At low flow, when pressure exceeds setpoint for a period, inverter drops to min frequency then stops; restarts when pressure drops below wake-up threshold. Suitable for small water systems.

Switching Tip

Multi-velocidade: P0.03=8

Pressão constante PID: P0.03=10

Change P0.03 and power cycle inverter for best stability.

Full ALPHA6000M Series Model List (ALPHA Mini Vector Inverters)

  1. Regra de codificação do modelo

ALPHA6000M S2 R75 G B RSM

  1. S2: Single-phase 220V input; 3: 3-phase 380V input
  2. R75=0.75kW; 1R5=1.5kW; 2R2=2.2kW
  3. G: General constant torque load; P: Fã & pump variable torque load
  4. B: Unidade de frenagem integrada (this model has B)
  5. RSM: RS485 Modbus communication option suffix

Nota importante: S2R4GB and S2R75GB only support V/F, no SVC vector; higher power models support vector control

  1. Monofásico 220V (S2 series, mini type, same family as your unit)

Modelos padrão (built-in braking unit GB)

  1. ALPHA6000M-S2R4GB | 0.4kW
  2. ALPHA6000M-S2R75GB | 0.75kW (base model of your unit)
  3. ALPHA6000M-S21R5GB | 1.5kW
  4. ALPHA6000M-S22R2GB | 2.2kW

With communication suffix RSM

S2R4GBRSM

S2R75GBRSM (seu modelo)

S21R5GBRSM

S22R2GBRSM

  1. 3-fase 380V (3 série, dual rating G/P)

Small power integrated type (unidade de frenagem embutida)

  1. ALPHA6000M-3R75GB/31R5PB | 0.75kW(G)/1.5kW(P)
  2. ALPHA6000M-31R5GB/32R2PB | 1.5kW(G)/2.2kW(P)
  3. ALPHA6000M-32R2GB/3004PB | 2.2kW(G)/4kW(P)
  4. ALPHA6000M-3004GB/35R5PB | 4kW(G)/5.5kW(P)
  5. ALPHA6000M-35R5GB/37R5PB-N | 5.5kW(G)/7.5kW(P)
  6. ALPHA6000M-37R5GB/3011PB | 7.5kW(G)/11kW(P)

Potência média (SJ suffix, external braking unit required)

  1. 3011GB/3015PB-SJ | 11/15kW
  2. 3015GB/3018PB-SJ | 15/18.5kW
  3. 3018GB/3022PB-SJ | 18.5/22kW
  4. 3022GB-SJ | 22kW

Fã & pump only P type (no G rating)

3030P-N, 3037P-N, 3045P-N … up to 3630P-N

  1. ALPHA6000M vs 6000E (Referência de substituição)
  2. 6000M: Mini compact version

Max power 22kW; small S2 single-phase units, compact terminals; S2R4/S2R75 no vector support; smaller mounting cutout, not interchangeable with 6000E.

  1. 6000E: Standard universal version

Power range 0.75~630kW; vector supported on all ratings; larger enclosure and mounting holes, incompatible with M series housing.

  1. Same Power Alternatives for S2R75GBRSM

Same series original: ALPHA6000M-S2R75GBRSM

Same power without communication: ALPHA6000M-S2R75GB

3-phase equivalent: 3R75GB (3-phase 380V input)

  1. Rated Current Table (Single-phase S2)
ModeloPoderCorrente de entradaCorrente de saída
S2R4GB0.4kW5.1UM2.4UM
S2R75GB0.75kW9.2UM4.5UM
S21R5GB1.5kW13.1UM7UM
S22R2GB2.2kW23UM10UM

Anterior:

Próximo:

Deixe uma resposta