The Chint NM1-125S/3300-63A Molded Case Circuit Breaker (MCCB) is a high-performance power distribution protection device in the NM1 series of Chint Group (CHNT). It is suitable for power distribution systems with an AC frequency of 50Hz and a rated operating voltage up to 690V, and is mainly used for overload, short-circuit, and under-voltage protection. The following is ...

  • Detalhes do produto

The Chint NM1-125S/3300-63A Molded Case Circuit Breaker (MCCB) is a high-performance power distribution protection device in the NM1 series of Chint Group (CHNT). It is suitable for power distribution systems with an AC frequency of 50Hz and a rated operating voltage up to 690V, and is mainly used for overload, short-circuit, and under-voltage protection. The following is a detailed analysis based on Chint’s official data and industry standards:

  1. Parâmetros principais e características técnicas
  2. Parâmetros Básicos

Corrente nominal (Em): 63UM, suitable for the load requirements of the circuit.

Quadro atual (Inm): 125UM, indicating the maximum current-carrying capacity of the circuit breaker.

Quebrando Capacidade:

Capacidade nominal máxima de interrupção de curto-circuito (UTI): 35o (at 400V), meeting the safety requirements of medium and high-risk power distribution scenarios.

Rated Service Short-Circuit Breaking Capacity (CIs): 18o, ensuring the circuit breaker can operate reliably after multiple faults.

Número do pólo: 3 postes (o primeiro “3” em 3300), applicable to three-phase four-wire or three-phase three-wire systems.

Características de disparo:

Thermomagnetic Release (o segundo “3” em 3300), with both overload long-time delay (tempo inverso) and short-circuit instantaneous protection functions.

Inverse Time Operation Characteristics: The conventional non-tripping current is 1.05In (no tripping within 2 horas), the conventional tripping current is 1.30In (tropeçando dentro 2 horas), and the instantaneous operation is set to 10In±20%.

  1. Desempenho Elétrico

Tensão nominal de isolamento (Ui): 800V, supporting the compatibility of high-voltage level systems.

Conformidade com Padrões: GB/T 14048.2 (equivalent to IEC 60947-2), and has obtained certifications such as CCC, ENVIAR, and CE, ensuring international versatility and reliability.

  1. Projeto Estrutural

Método de instalação: Suporta instalação vertical ou horizontal, flexibly adapting to different cabinet layouts.

Método de fiação: Front-panel wiring (standard configuration); some upgraded models offer plug-in design (por exemplo, NM1-125S/3300 63A G).

Arc Flash Distance: ≤50mm, reducing the risk of damage to surrounding equipment caused by fault arcs.

  1. Cenários de aplicativos e configurações típicas
  2. Application Fields

Industrial Power Distribution: Power protection for power equipment such as machine tools and production lines.

Edifícios Comerciais: Control of distribution boxes and branch circuits in office buildings and shopping malls.

Residential and Small-Scale Infrastructure: Overload protection for indoor main incoming lines or high-power electrical appliances (por exemplo, condicionadores de ar, aquecedores elétricos de água).

  1. Expansão de acessórios

Auxiliary Functions: Can be equipped with a shunt release (for remote circuit breaking), an under-voltage release (for automatic disconnection when voltage is abnormal), or an alarm contact (for fault status signal output) to meet the needs of intelligent control.

Compatibilidade de instalação: Accessory modules are universal with other models in the NM1 series, facilitating later function upgrades.

III. Usage and Maintenance Recommendations

  1. Installation Specifications

Requisitos Ambientais: Ambient air temperature ranges from -5℃ to +40℃, altitude ≤2000m, and strong magnetic field interference should be avoided.

Wiring Requirements: Tighten terminal bolts to the specified torque (refer to the manual) to ensure reliable contact and prevent overheating.

  1. Operation and Maintenance Key Points

Inspeção Regular: Clean the dust on the housing every six months, check the wear of contacts, and replace them if necessary.

,Fault Troubleshooting: Se ocorrerem disparos frequentes, it is necessary to check whether the load exceeds the limit, whether the line is short-circuited, or whether the setting value of the release is reasonable.

  1. Replacement and Upgrade

New Model Replacement: Since 2021, Chint has launched upgraded platform-type products (models with suffix “G”), such as NM1-125S/3300 63A G. The breaking capacity is increased to 50kA, and the installation dimensions are compatible with the old models, enabling seamless replacement.

Local Procurement: Contact Chint’s authorized distributor via WhatsApp: 0086-13811255435 to obtain spot goods and technical support.

  1. Key Considerations for Selection
  2. Matching of Breaking Capacity: Select the corresponding breaking level (por exemplo, Type S: 35o, Type H: 50o) according to the short-circuit current level to avoid equipment damage due to insufficient selection.
  3. Adaptation of Tripping Curve: For power distribution scenarios, Tipo C (5-10 times In instantaneous tripping) is preferred; for motor protection, Tipo D (10-14 times In) é necessário.
  4. Certification Compliance: For domestic projects, CCC certification must be confirmed; for export projects, attention should be paid to the standards of the target market (por exemplo, CE, NOM).