CHINT YBLX-K1/511 Limit Switch - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

CHINT YBLX-K1/511 Limit Switch - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

elétrica/

CHINT YBLX-K1/511 Limit Switch

CHINT YBLX-K1/511 (often miswritten as YBLX-K1511) is a universal self-resetting limit switch belonging to the YBLX-K1 series. It is widely used for overtravel protection and position control in industrial automation and machine tools. Parâmetros principais & Structure Item Specification Full Model YBLX‑K1/511 (JLXK1/511) Actuator Type Universal type (code “5”) Configuração de contato 1 NÃO + 1 ...

  • Detalhes do produto

CHINT YBLX-K1/511 (often miswritten as YBLX-K1511) is a universal self-resetting limit switch belonging to the YBLX-K1 series. It is widely used for overtravel protection and position control in industrial automation and machine tools.

  1. Parâmetros principais & Estrutura
ItemEspecificação
Modelo CompletoYBLX‑K1/511 (JLXK1/511)
Actuator TypeUniversal type (code “5”)
Configuração de contato1 NÃO + 1 NC
Tensão nominalAC 380 V, CC 220 V
Corrente nominalAC‑15 0.8 UM, DC‑13 0.15 UM
Grau de ProteçãoIP52
StandardsGB/T14048.5, IEC60947‑5‑1
Capacidade de fiação1×(0.5–1) mm² cable, stripping length 7–9 mm
Fastening ScrewM3.5, torque de aperto 0.8 N·m
Operating FrequencyMecânico: 1200 operações/hora; Elétrica: 600 operações/hora
Vida útilMechanical ≥ 1,000,000 cycles; Electrical ≥ 100,000 cycles
  1. Model Meaning Explanation

Meaning of each part in YBLX-K1/511:

YBLX: General code for limit switch

1º trimestre: Quick-action series

/5: Actuator is universal type (actuated from any direction)

/11: Contact combination 1 NÃO + 1 NC

  1. Principais recursos & Vantagens
  2. Universal actuation design: Actuator senses in 360° directions, suitable for complex installations
  3. Self-resetting: Automatically returns to original position after actuation, no manual reset needed
  4. Silver-alloy contacts: Excellent conductivity, arc resistance, wear resistance, longa vida útil
  5. IP52 protection: Dust-proof and moisture-proof for industrial environments
  6. Flexible installation: Supports multiple mounting methods for various layouts
  7. Safe and reliable: Complies with international standards, short-circuit withstand up to 1000 UM
  8. Aplicativos
  9. Machine tools: Table travel limit, automatic reciprocating control
  10. Automated production lines: Material positioning, lifting mechanism limit protection
  11. Lifting machinery: Limit protection, anti-collision control
  12. Máquinas de embalagem: Posicionamento, counting control
  13. Textile machinery: Yarn tension control, mechanical limit
  14. Other industrial equipment: Motion control, direction/speed change control
  15. Instalação & Wiring Guide

Etapas de instalação

  1. Select proper mounting position to ensure reliable actuation of the actuator
  2. Secure the switch with M4 screws, tightening torque 0.8–1.2 N·m
  3. Connect wires:

NO contact: “turn on at positionin control circuit

NC contact: “turn off at position” (commonly used for emergency stop)

  1. Check actuation direction and reset for sensitive and reliable operation
  2. Power on and test to confirm normal circuit function

Wiring Notes

Cable stripping length: 7–9 mm; avoid too short or too long exposed conductor

Tighten terminals securely to prevent loose connections

Distinguish AC/DC circuits; do not exceed rated voltage/current

Avoid direct control of high-power loads; use an intermediate relay if needed

  1. Operação & Manutenção
  2. Regularly check actuator flexibility and reset performance
  3. Clean contact area to remove dust and oil, preventing poor contact
  4. Inspect wire connections for looseness caused by vibration
  5. Avoid overtravel and overfrequency operation to protect internal mechanism
  6. Replace the switch promptly if contact burning, sluggish action, etc.. occur
  7. Replacement & Referência de seleção

Other common models in YBLX-K1 series:

YBLX-K1/111: Single roller lever type, 1 NÃO + 1 NC

YBLX-K1/211: Double roller lever type, 1 NÃO + 1 NC

YBLX-K1/311: Plunger type, 1 NÃO + 1 NC

YBLX-K1/411: Roller plunger type, 1 NÃO + 1 NC

  1. Purchasing & Warranty Information

Official Order No.: 7101125000000511

CHINT Limit Switch Series List & Cross-Brand Model Cross-Reference

  1. Complete CHINT Limit Switch Series List
SérieCaracterísticasAplicações TípicasRepresentative Models
YBLX‑K1 / JLXK1Quick‑action, multiple actuators, self‑resettingMachine tools, automationYBLX‑K1/111, YBLX‑K1/511
YBLX‑ME / 8000General purpose, compatible with Schneider XCE mountingGeneral machinery, assembly linesYBLX‑ME/8108, YBLX‑ME/8101
YBLX‑19Roller lever type, various lever configurationsMachine tables, lifting mechanismsYBLX‑19‑111, YBLX‑19‑222
YBLX‑WLWatertight, IP65Outdoor equipment, wet environmentsYBLX‑WL/CA120, YBLX‑WL/CA220
YBLX‑P1Plunger type, short stroke, high frequencyStamping equipment, countersYBLX‑P1/303, YBLX‑P1/120
YBLX‑10Heavy‑duty, high current, metal housingCranes, metalurgiaYBLX‑10/11, YBLX‑10/21
YBLX‑JW2Micro, short stroke, high sensitivityPrecision machinery, instrumentsYBLX‑JW2/11Z/3, YBLX‑JW2/22Z
YBLX‑33 / 44Heavy‑duty, high operating force, robustPort machinery, mineraçãoYBLX‑33/11, YBLX‑44/22
YBLX‑X2Compactar, miniaturizedSmall equipment, medical devicesYBLX‑X2/11G, YBLX‑X2/22D
NKX2 / NKX3Modern design, modular mountingSmart factories, automation linesNKX2‑11Z, NKX3‑22Z
YBLXW‑6Microswitch, small size, high sensitivityElectronics, home appliancesYBLXW‑6/11DL, YBLXW‑6/22CL
YBLX‑HLHigh temperature resistant, ‑25 ~ +120 °CMetalurgia, drying equipmentYBLX‑HL/11, YBLX‑HL/22
YBLX‑3 / LX3Metal housing, protected designMáquinas pesadas, explosion‑proof areasYBLX‑3/11H, YBLX‑3/22J
  1. Cross-Brand Model Cross-Reference (Major Brands)

2.1 CHINT vs Schneider (Most Common Replacement)

CHINT ModelEquivalent SchneiderNotas
YBLX‑K1/511XCE145Universal actuator, 1 NÃO + 1 NC, montagem compatível
YBLX‑ME/8108XCE102Roller lever, self‑resetting, matching electrical ratings
YBLX‑ME/8101XCE101Plunger type, quick action, same mounting holes
YBLX‑K1/111XCE118Single roller lever, 1 NÃO + 1 NC, similar operating force
YBLX‑19‑111XCE110Straight lever inner actuation, same mounting space
YBLX‑WL/CA120XCKD2120P16Watertight, 2 NÃO + 2 NC, IP65

2.2 CHINT vs Siemens

CHINT ModelEquivalent SiemensNotas
YBLX‑K1/5113SE5 112‑0CH01Universal, 1 NÃO + 1 NC, mechanical life ≥ 1M cycles
YBLX‑ME/81083SE5 100‑0CH02Roller lever, self‑resetting, montagem compatível
YBLX‑19‑2223SE5 122‑0CH01Forked double roller lever, bidirectional limit
YBLX‑P1/3033SE5 212‑0CH01Long plunger, short stroke, high frequency
YBLX‑WL/CA2203SE5 232‑0CH01Watertight, 3 NÃO + 3 NC, outdoor use

2.3 CHINT vs ABB

CHINT ModelEquivalent ABBNotas
YBLX‑K1/111LS31K01Single roller lever, 1 NÃO + 1 NC, matching ratings
YBLX‑ME/8108LS31K10Roller lever, self‑resetting, same mounting position
YBLX‑19‑131LS31K20Straight lever groove actuation, consistent precision
YBLX‑P1/120LS31K30Short plunger, quick action, similar response

2.4 CHINT vs Omron

CHINT ModelEquivalent OmronNotas
YBLX‑K1/511D4V‑8108SZUniversal, 1 NÃO + 1 NC, operating force 0.5–1.5 N
YBLX‑ME/8108D4V‑8166ZRoller lever, self‑resetting, mechanical life ≥ 1M cycles
YBLX‑WL/CA120D4V‑8122ZWatertight, 2 NÃO + 2 NC, IP65
YBLXW‑6/11DLD4V‑2120ZMicroswitch, short roller lever, 1 NÃO + 1 NC
  1. Key Points for Replacement & Seleção
  2. Compatibilidade de montagem: Prefer models with identical mounting dimensions (por exemplo, YBLX-ME ↔ XCE) for direct replacement
  3. Electrical matching:

Tensão nominal: AC 380 V / CC 220 V

Corrente nominal: AC-15 0.8 UM, DC-13 0.15 UM

Contatos: 1 NÃO + 1 NC (padrão), 2 NÃO + 2 NC (special)

  1. Actuator type matching:
Actuator TypeCHINT CodeInternational Equivalent
Universal5XCE145, 3SE5 112 série
Single roller lever1XCE118, 3SE5 100 série
Double roller lever2XCE110, 3SE5 122 série
Plunger3XCE101, 3SE5 101 série
Roller plunger4XCE103, 3SE5 103 série
  1. Protection level selection:

General environment: IP52 (YBLX-K1)

Humid environment: IP65 (YBLX-WL)

Outdoor use: IP67 (custom models)

  1. Seleção & Recomendações de substituição
  2. Prefer direct series replacement: YBLX-ME ↔ XCE, YBLX-K1 ↔ 3SE5 are most reliable
  3. Contact count: Ensure NO/NC quantity matches to avoid logic errors
  4. Mechanical parameters: Match operating force, travel, reset speed to prevent misoperation
  5. Special environment adaptation:

Outdoor / wet: YBLX-WL (IP65)

Alta temperatura: YBLX-HL (-25 ~ +120 °C)

Explosion-proof: YBLX-3 (metal housing, certified)