EUCHNER CES-AZ-AES-02Relé de segurança B - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

EUCHNER CES-AZ-AES-02Relé de segurança B - Contator,disjuntor,sensor,Codificador,CLP,Conversor

CLP/

EUCHNER CES-AZ-AES-02Relé de segurança B

Pedido nº.: 104775 It belongs to the CES-AZ series, a Transponder Non-Contact Safety Evaluation Unit (integrated safety relay). It adopts Unicode (single coding), which only recognizes the uniquely taught actuator. It supports up to 2 read heads. Key Specifications Max. number of read heads: 2 (CES-A-L… series read heads) Nível de segurança: Categoria 4 / PT ...

  • Detalhes do produto

Pedido nº.: 104775

It belongs to the CES-AZ series, a Transponder Non-Contact Safety Evaluation Unit (integrado relé de segurança). It adopts Unicode (single coding), which only recognizes the uniquely taught actuator. It supports up to 2 read heads.

Especificações principais

Máx.. number of read heads: 2 (CES-A-L… series read heads)

Nível de segurança: Categoria 4 / PL e (EM ISO 13849-1)

Saídas de segurança: 2 relay safety outputs, cada um com 2 internally series-connected NO contacts for redundancy

Coding type: Unicode (single coding); only the last taught actuator will be identified.

Multi-code alternative: CES-AZ-UES-02B (Número do pedido. 105140, Multicode)

Additional interfaces: Start button monitoring (falling edge detection), external contactor feedback loop, TST test input, DIA diagnostic output, O1/O2 semiconductor status outputs

Montagem: 35 mm trilho DIN

Classe de proteção: IP20 (only for cabinet installation)

Fonte de energia: CC 24V (21~27V DC regulated power supply, ondulação <5%)

Consumo de energia: Aprox.. 150 mA with relay energized

Terminais: Plug-in coded terminals, wire cross-section 0.25–2.5 mm²

Temperatura operacional: -20℃ ~ +55℃, sem condensação, relative humidity ≤80%

Peso bruto: 0.299 kg

Código Aduaneiro HS: 85364110

ECLASS: 27-27-24-03 Safety-related transponder switch

Definição de terminal

UB / 0V: Fonte de alimentação DC24V

J1, J2: Teach-in jumpers (to write actuator coding)

H11/H12, H21/H22: Signal for read head 1 & read head 2

SH1, SH2: Shield grounding for read heads

TST: Self-test input

S: Start button input (falling edge detection)

Y1/Y2: External feedback loop

13/14, 23/24: Two groups of safety relay outputs

DIA: Diagnostic output; O1/O2: Semiconductor status outputs for read heads

RESET pushbutton; Indicadores LED: Poder, H1, H2, OUT safety status, DIA fault diagnosis

Series Comparison Table

ModeloNúmero do pedido.Read Head QuantityCoding Type
CES-AZ-AES-01B1047701Unicode
CES-AZ-AES-02B1047752Unicode (este modelo)
CES-AZ-AES-04B1047804Unicode
CES-AZ-UES-02B1051402Multicode

Cenários de aplicação

Recurso principal

One evaluation unit monitors 2 safety gates/protection points simultaneously. The Unicode exclusive coding prevents bypass and replacement, ideal for high tamper-proof requirements. It works with non-locking CES read heads and locking CEM/CET safety interlocks (EM 1088).

  1. Indústria de máquinas-ferramenta (Mais Comum)
  2. Centros de usinagem, CNC milling machines & tornos: Dual front + side safety doors. Immediate safe stop once any door opens. Paired with CET locking read heads to keep doors locked until spindle coasts to rest.
  3. Máquinas retificadoras, high-speed saws & puncionadeiras: Two protective covers for high-speed rotating and reciprocating motions, meeting PL e safety requirements.
  4. Laser cutting & máquinas de corte a plasma: Upper and lower material loading doors; laser emission is only enabled when both doors are fully closed.
  5. Linhas de produção automatizadas & Assembly Equipment
  6. Robot workcells (fencing): Two access gates for the robot enclosure; robot stops immediately if a gate opens during operation.
  7. Custom assembly machines, hydraulic presses & máquinas de rebitagem: Front maintenance door + side material feed door with interlock logic.
  8. Transportadores, máquinas de transferência & rotary lifting stations: Service access gate + bypass protection gate.
  9. Moldagem por injeção & die-casting machines: Mold safety door + barrel protective door with lock function to prevent opening during mold clamping and melt processing.
  10. Embalagem, Impressão, Bateria de lítio & 3C Equipment
  11. High-speed packaging, laminação & máquinas de corte: Two rotary roller guard doors.
  12. Li-ion winding machines, máquinas de enchimento de eletrólitos & formation cabinets: Dual chamber doors to prevent high-voltage hazards and mechanical pinch injuries.
  13. Máquinas de colocação SMT, AOI testers & FPC equipment: Front and rear maintenance hatches.

Vantagem: Non-contact design with no mechanical wear, long service life and resistance to dust and oil contamination.

  1. Manuseio de materiais & Equipamento de armazém
  2. Vertical elevators & elevadores: Upper and lower level protective doors.
  3. Sistemas de classificação & tipos de cinto cruzado: Two fence service doors.
  4. Small AGV and tooling trolley cabin hatches.
  5. Comida & Máquinas Farmacêuticas (Cleanroom Use)
  6. Máquinas de enchimento, bottle washers & máquinas de selagem: Dual clean chamber doors.
  7. Equipamento de esterilização: Chamber door + service door. Non-contact design avoids jamming and is easy to clean with no mechanical friction.

Observação: Select stainless steel food-grade read heads for this application.

  1. Test Benches & Laboratory Tooling
  2. High-voltage test stands & aging cabinets: Two safety hatches; Unicode coding prevents personnel from shorting safety circuits to access hazardous areas.
  3. Impact and durability test rigs: Dual protective enclosure doors.

Guia de seleção de modelo (Crítico)

CES-AZ-AES-02B (Unicode)

Only recognizes the last taught actuator. Anti-tampering priority. For machines with safety audits and strict anti-bypass requirements.

CES-AZ-UES-02B (Multicode)

Accepts any actuator of the same series. Only used for position monitoring; easier maintenance without re-teaching after actuator replacement.

02B = Max. 2 read heads; choose 04B for 4 portões de segurança.

Recommended Matching Read Heads

CES-A-LNN: Non-locking type, only for door position monitoring

CEM: Process lock for production process protection

CET: Personnel safety lock (door locked until machine stops coasting; EM 1088)

Aplicativos inadequados

Mais do que 2 independent safety doors (select 04B or safety PLC instead)

Multiple gates requiring separate logic and different stop sequences (use a safety controller)

Simple door monitoring without anti-bypass requirements (UES version offers better cost performance)

EUCHNER CES-AZ-AES-02B (Número do pedido. 104775) Full Technical Data

Tipo: Unicode (single coding) non-contact transponder safety evaluation unit, máx.. 2 read heads

  1. Ordem & Coding Information

Pedido nº.: 104775

Coding type: Unicode (unique coding); only the last taught actuator will be recognized to prevent bypass replacement

Supported read heads: 2 unidades (CES-A-L… / CEM / CET series)

ECLASS: 27-27-24-03

Código Aduaneiro HS: 85364110

  1. Desempenho de segurança (EM ISO 13849-1 / E IEC 62061)

Safety category: Categoria 4

Performance level: PL e

SIL rating: SIL 3

PFHD: 1.3×10⁻⁸

Mission time: 20 anos

Safety architecture: Dual redundant relay safety outputs; each channel has 2 internally series-connected monitored NO contacts

  1. Parâmetros Elétricos
  2. Supply voltage UB: DC 21~27V, rated DC24V (regulated power supply, ondulação <5%), UL Class 2 power supply required
  3. Consumo de energia: Aprox.. 150 mA with relay energized (excluding load of monitoring outputs)
  4. Relay safety outputs (13/14, 23/24)

Tensão nominal de isolamento: 250 V e

Máx.. tensão de comutação: 250 V e / 30 Em DC

Continuous thermal current Ith: 8 UM

AC-15: 6 UM / 230 V e; DC-13: 4 UM / 24 Em DC

  1. External feedback loop Y1/Y2

Loop current: 5~8~10 mA

Máx.. allowed loop resistance: 600 Oh

  1. Entradas digitais (S Start, TST Test)

Nível baixo: 0~2 V DC; Alto nível: 15~27 V DC

  1. Semiconductor monitoring outputs O1/O2, DIA

Tipo: NPN transistor output, NOT safety outputs

Máx.. corrente de carga: 100 mA

  1. Terminais: Plug-in coded spring terminals, wire cross-section 0.25–2.5 mm²
  2. Recommended external fuse: Máx.. 8A gG
  3. Mecânico & Dados Ambientais

Dimensões gerais: 114 × 99 × 45 milímetros

Material de habitação: PA6.6 engineering plastic

Peso: Aprox.. 0.25 kg

Montagem: 35 mm trilho DIN (EN60715 TH35)

Classe de proteção: IP20 (cabinet-only installation)

Grau de poluição: 2

Temperatura ambiente operacional: -20 ℃ ~ +55 ℃

Umidade relativa: ≤80%, sem condensação

Posição de montagem: Qualquer orientação

  1. Interfaces & Indicadores

Terminais: UB/0V power, H11/H12 (read head 1), H21/H22 (read head 2), SH1/SH2 shield, S Start, TST Test, Y1/Y2 feedback, 13/14 & 23/24 saídas de segurança, O1/O2 read head status, DIA diagnosis

Operating elements: RESET pushbutton, J1/J2 teach-in jumpers

Indicadores LED: Poder, H1, H2, OUT safety status, DIA fault diagnosis

  1. Read Head Compatibility

Reliable operating distance Sar: Máx.. 26 milímetros (depends on read head model)

Compatible types: Non-locking door monitors CES-A-LNN / CES-A-LCA; process interlocks CEM; personnel safety interlocks CET (EM 1088)

  1. EMC & Padrões de Conformidade

EMC standard: E IEC 60947-5-3

Padrões aplicáveis: EM ISO 13849-1, E IEC 62061, EM 1088 (for guard lock applications)

  1. Diferenciação de Modelo

CES-AZ-AES-02B: Unicode, anti-replacement, Cat.4 / PL e

CES-AZ-UES-02B (105140): Multicode, accepts any same-series actuator, manutenção mais fácil

EUCHNER Safety Relay / Evaluation Unit Model & Lista de números de pedido

Two main product lines: ESM standalone safety relays (uso geral) and CES-AZ transponder evaluation units (your target model), plus CES-AR series for serial connection.

Observação: CES-AZ is a transponder decoding safety evaluation unit, generally referred to as a safety relay in the industry. All models meet Cat.4 / PL e (EM ISO 13849-1).

  1. ESM Series General Safety Relays (Parada de emergência, portão de segurança, controle bimanual, expansão de contato)

1) ESM-BA Non-Time-Delay Basic Modules (Cat.4)

ModeloNúmero do pedido.Descrição
ESM-BA201856102 contatos NO de segurança, terminais de parafuso
ESM-BA201P972262 contatos NO de segurança, terminais de encaixe
ESM-BA301856133 NÃO + 1 contato auxiliar, terminais de parafuso
ESM-BA301P972303 NÃO + 1 contato auxiliar, terminais de encaixe
ESM-BA701972247 contatos NO de segurança, terminais de parafuso
ESM-BA701P972257 contatos NO de segurança, terminais de encaixe

2) ESM-BT Time-Delay Modules (Cat.4, adjustable 1~30s; fixed-delay versions available)

ModeloNúmero do pedido.Descrição
ESM-BT401908181 instantâneo + 3 delayed outputs
ESM-BT411908192 instantâneo + 2 delayed outputs
ESM-BT411-20S900772 instantâneo + 2 delayed outputs, fixed 2s delay
ESM-BT421908203 instantâneo + 1 delayed output
ESM-BT421-50S900943 instantâneo + 1 delayed output, fixed 5s delay

3) ESM-2H Two-Hand Control Modules (EN574 / Type IIIC)

ModeloNúmero do pedido.Descrição
ESM-2H20185620Two-hand control, 2 contatos de segurança
ESM-2H20298345Two-hand control, 2 contatos de segurança

4) ESM-ES Contact Expansion Modules (Non-delay, used with BA/BT main units)

ModeloNúmero do pedido.Descrição
ESM-ES301856143NÃO + 1 auxiliar, terminais de parafuso
ESM-ES302856153NÃO + 1 auxiliar, 230V e
ESM-ES303856163NÃO + 1 auxiliar, 115V e
ESM-ES301P900573NÃO + 1 auxiliar, terminais de encaixe

5) ESM-TE Time-Delay Expansion Modules

ModeloNúmero do pedido.Descrição
ESM-TE30185617Delay expansion, adjustable 1–30s
ESM-TE30385619Delay expansion, 230V e
ESM-TE301-05S97223Fixed 0.5s delay expansion

6) ESM Accessories

ModeloNúmero do pedido.Descrição
ESM-F-AK497194Screw terminal kit for ESM-P
ESM-F-KK497195Spring terminal kit for ESM-P
  1. CES-AZ Series Transponder Evaluation Units (Unicode AES anti-tamper / Multicode UES general type)

AES = Unicode (only recognizes taught actuators, anti-bypass); UES = Multicode (accepts any same-series actuator, fácil manutenção)

ModeloNúmero do pedido.Read Head CountCoding Type
CES-AZ-AES-01B1047701Unicode
CES-AZ-AES-02B1047752Unicode (seu modelo)
CES-AZ-AES-04B1047804Unicode
CES-AZ-UES-01B1051391Multicode
CES-AZ-UES-02B1051402Multicode
CES-AZ-UES-04B1051494Multicode
CES-AZ-ABS-01B1000641Old Unicode version, Cat.3

III. CES-AR Serial Link Evaluation Unit (Máx.. 12 AR read heads wired in series)

ModeloNúmero do pedido.Descrição
CES-AR-AES-1298225Até 12 AR read heads in series, Cat.4 PL e

Guia de seleção rápida

  1. ESM-BA/BT: General safety relays for E-stop, regular safety gates and light curtains; no transponder decoding function.
  2. CES-AZ-AES: Transponder-only type, anti-replacement & anti-cheating; for machine tools and automation with strict anti-bypass requirements.
  3. CES-AZ-UES: Transponder-only type; no re-teaching needed after actuator replacement, preferred for mass-produced equipment.
  4. CES-AR-AES-12: Long-distance serial connection for multiple safety gates, reduces wiring work.

I can export this whole text into pure plain text (without tables) for direct copy to Excel, or provide the wiring diagram + fault LED troubleshooting list in English. Do you need that?