Posicionamento: 23.1-inch IMO-compliant marine radar dedicated display unit (CR = Radar version). It is the matching display for FAR-28X7 radar and is now End of Life (EOL).
Distinção: MU-231 is a universal multi-input marine display; MU-231CR is a radar-customized version with interfaces and firmware specially adapted for FURUNO black-box radar systems. It is NOT a general-purpose monitor.
Especificações principais
Tela: 23.1″ LCD colorido, UXGA 1600 × 1200
Brilho: 400 CD/m², built-in light sensor for automatic dimming
Contrast Ratio: 600:1
Entrada de sinal: Single dedicated DVI-D radar port, no RGB / composite video input, PIP (Picture-in-Picture) não suportado (main difference from MU-231)
Fonte de energia: 100–230 VCA, single-phase 50/60Hz (AC only)
Certificação: IMO Wheel Mark, compliant with marine radar regulations for seagoing vessels
Power-on Logic: Auto power on/off triggered by DVI signal; no physical control buttons on the unit itself
Montagem: Flush panel mount / cantilever bracket mount (bracket sold separately)
Peso: 16.6 kg (montagem em painel); 23.5 kg (bracket mount)
Compatible Radar Systems
✅ FAR-2807 / FAR-2817 / FAR-2827 (FAR-28X7 series, paired with RPU-013 radar processor)
✅ FAR-2107, FAR-2127 (black-box radar with dedicated DVI-D radar video output)
⚠️ Limitação importante: Cannot connect directly to standard PC DVI outputs. It only recognizes proprietary radar DVI video signals from FURUNO radar processors.
System Components for Complete FAR28X7 Radar
MU-231CR: Radar display unit
RPU-013: Radar processor unit
RCU-014: Full keyboard control unit / RCU-015: Trackball control unit / RCU-016: Remote control unit
XN-12AF / XN-20AF / XN-24AF: Radar antenna units
Substituição & Informações sobre peças sobressalentes
- Original new units are no longer available on the market; supplies are mainly used pull-outs and refurbished units.
- Opções de substituição: New-generation FURUNO radar displays (processor protocol and panel cutout dimensions must be evaluated together).
- Common failure points: Backlight board, DVI interface board, power supply board, ambient light sensor assembly.
- Document Part Number: OMC-44690 (shares base manual with MU-231; separate schematic drawings apply for CR variant).
Tabela de comparação: MU-231CR vs MU-231
| Item | MU-231CR (Radar Version) | MU-231 (Universal Marine Version) |
| Entrada | Dedicated radar-only DVI-D port only | Dual DVI + RGB + composite video |
| PIP Picture-in-Picture | ❌ Não suportado | ✅ Suportado |
| Aplicativo | Exclusive for FAR-series radar | Radar, ECDIS, echo sounder, sonar, camera multi-source switching |
| Auto Power Control | DVI signal triggered | DVI signal triggered |
FURUNO MU-231CR Supporting Manual List
Nota importante: FURUNO does not release a standalone manual for MU-231CR. The MU-231CR is a dedicated display bundled with FAR-28X7 radar systems. The base hardware documentation is shared with MU-231. CR-specific differences, radar linkage logic and proprietary DVI protocol details are documented within the FAR-28X7 radar system manuals.
- Main Display Operation Manual (Obrigatório, OMC-44690)
Title: MU-231 Operator’s Manual
Document No.: OMC-44690, Revision D2 (latest revision)
Contente: Installation cutout dimensions, fiação, fonte de energia, auto brightness adjustment, menu configuration, basic maintenance, outline drawings, terminal definitions, basic troubleshooting
Aplicável: MU-231 / MU-231CR (CR variant only differs in firmware and input lockout; mecânico, power and hardware circuits are identical)
Linguagem: Bilingual English + japonês
Limitação: This manual does not cover proprietary radar DVI protocol or RPU-013 interworking logic, only the display hardware itself.
- Quick Reference Guide (for on-site commissioning)
Title: MU-190 / MU-231 Operator’s Guide
Compact quick-start booklet for vessel crews and field technicians: brightness adjustment, auto dimming, access to installation menu, menu unlock
No schematics or spare part BOM; for daily onboard operation only.
- Radar System Master Manual (Core Reference for MU-231CR, Altamente recomendado)
The MU-231CR cannot operate independently without the FAR-28X7 radar processor. Radar linkage, signal timing, power-up sequence and RCU control integration are all covered in this set of documents
- FAR-2807 / FAR-2817 / FAR-2827 Operator’s Manual (Radar Operation Manual)
For RPU-013 processor, covers radar video output to MU-231CR, trackball/keyboard control, ARPA target tracking
- FAR-28X7 Installation & Service Manual
Contains complete system interconnection wiring diagrams, RPU-013 ↔ MU-231CR dedicated DVI link description, isolamento obrigatório, spare parts list and system commissioning procedures
- Supplementary control unit manuals: RCU-014 / RCU-015 / RCU-016 Operator Manuals
- Service-Level Manuals (Reparo no nível da placa, for agents & service workshops)
MU-231 Service Manual: Schematics, placa de energia / backlight board / driver board disassembly, voltage test points, spare part BOM
⚠️ This document is not available for public download; access restricted to FURUNO authorized service channels, public resources are scarce.
- Multilingual Versions (Opcional)
MU-190/MU-231 French Quick Guide, Spanish Quick Guide (for foreign vessel crews)
Reading Priority Recommendation
✅ On-site installation & fiação: OMC-44690 (MU-231 Operator Manual) + FAR-28X7 Installation Manual
✅ Daily radar operation by crew: FAR-28X7 Radar Operator Manual (Do not rely only on the display manual; the CR model has no independent radar picture menus)
✅ Board replacement & tela preta / no radar signal troubleshooting: FAR-28X7 Service Manual + MU-231 Service Manual
Common Pitfall Reminders
- Do not commission MU-231CR using only the MU-231 universal manual: universal MU-231 supports multi-DVI and PIP, while MU-231CR firmware disables these functions. CR-specific notes inside the FAR radar manual must be referenced.
- Searching “MU-231CR manual” online will almost never return standalone documents. Industry standard practice: use OMC-44690 together with FAR28X7 system manuals.
FURUNO MU-231CR Black Screen / No Radar Image Troubleshooting Checklist
Condição prévia: MU-231CR is a dedicated radar display and only accepts proprietary DVI signals from RPU-013 radar processors. Troubleshooting logic differs from standard monitors. Three symptom categories: [Complete black screen, indicador de energia desligado], [Power indicator ON but screen black / backlight on, no radar picture], [Backlight ON, tela preta, No Signal prompt]
- Initial Status Verification (Onboard Priority Checks)
- Verify power supply for the whole system: MU-231CR runs on AC 100–230V. Verifique os disjuntores, internal fuses, shipboard voltage, perda de fase, voltage drop and transient power loss.
- Confirm matched equipment: This display must work with RPU-013 radar processor. Antenna unit and RCU control unit also need power supply.
- Observe front indicator lamp:
Power lamp OFF: Fault in power circuit or display power supply board
Power lamp steady ON, no picture: Fault in signal link, RPU processor, dedicated DVI cable or backlight/driver board
- Follow regulated power-up sequence: Power on RPU-013 radar processor first, then MU-231CR. MU-231CR wakes up only upon valid radar DVI signal; standalone power-up will result in black screen (not a hardware fault).
Equívoco comum: Powering MU-231CR alone without RPU signal output → black screen, this is normal behaviour.
- Symptom A: Fully Black Screen, Power Indicator OFF
- Measure AC input voltage at the socket to confirm within rated range.
- Check internal input fuse on display power board. Replace with same specification if blown. Never use a higher-rated fuse.
- Disconnect DVI cable and power the display separately to check whether downstream short circuit pulls down power rail.
- If input voltage is normal and fuse intact but lamp remains off: fault points to MU-231CR power supply board.
- Measure power board output rails against service manual: 24V, 5V and backlight supply.
- Symptom B: Power Lamp ON, No Backlight (Screen Completely Dark)
- Open cover slightly and listen for faint high-frequency hum from backlight inverter; no hum = backlight circuit failure.
- Troubleshoot: backlight inverter / backlight panel, backlight power harness, loose LVDS screen cable.
- Distinguish LCD panel damage vs backlight driver failure.
- Quick test: Shine a flashlight obliquely onto the screen. Faint radar menu characters visible → backlight failure; nothing visible → signal / mainboard fault.
- Symptom C: Backlight ON, Black Screen, “No Signal” Prompt (Mais Comum)
Crítico: MU-231CR runs dedicated firmware, standard PC DVI signals are rejected and trigger No Signal.
- Check RPU-013 radar processor status: Power and RUN indicators, active fault codes.
- Reboot sequence: Full power cut for 3 minutos (descarga do capacitor) → power RPU-013, wait 2–3 minutes for full self-test completion → then power MU-231CR.
- Inspect dedicated DVI cable: This is FURUNO radar-specific DVI cable; standard DVI cables are not compatible. Dobrado, oxidized or loose pins at connectors are frequent failure points.
- Re-seat DVI connectors at both ends: RPU-013 rear DVI port ↔ MU-231CR DVI input port, clean pin contacts.
- Cross-test if spare parts available:
Swap with a confirmed good original radar DVI cable
Se possível, connect MU-231CR to a known working RPU-013 from another FAR-28X7 system to isolate failure between display and processor
- Inspect RPU-013 internals: RPU mainboard, video output board; faulty RPU will not transmit proprietary radar DVI stream.
- Observação: Faulty RCU control box will not cause black screen / no image, only loss of radar control.
- Symptom D: Backlight ON, Screen Black, No “No Signal” Pop-up
- Loose LVDS/eDP screen cable: Power off and re-seat harness between screen driver board and LCD panel.
- Display main signal board failure: Receives DVI clock but cannot decode FURUNO proprietary radar video.
- Firmware corruption: CR firmware is locked in radar-only mode. Corrupted firmware can only be reflashed by FURUNO service; field reflashing is not possible.
- Ambiental & Interference Checks (Often Overlooked Onboard)
- Ship power harmonic distortion / inverter noise: If radar shares supply with heavy loads (guindastes, motores grandes), temporarily connect to isolated clean power supply for testing.
- Aterramento: RPU, display and antenna protective earth must connect reliably to ship ground. Poor grounding causes intermittent video dropout and black screen.
- Temperatura: Overheat inside cabinet triggers thermal protection on power board and DVI chipset; function resumes after cooling. Recurring issue indicates poor ventilation.
- Isolation Logic for Rapid Fault Localization
Normal power + RPU self-test OK + good dedicated DVI cable → Fault inside MU-231CR (placa de energia / backlight board / main control board / LCD panel)
Normal power + replacement good MU-231CR still shows no signal → Fault in RPU-013 radar processor or antenna link
Intermittent black screen, recovered after tapping connector → DVI cable or contact pin failure
- Repair Prohibitions & Notas de segurança
- Never substitute MU-231CR with a standard commercial DVI monitor; protocol incompatibility means no radar picture.
- Do not flash universal MU-231 firmware onto MU-231CR; radar-specific functions will be lost and the unit bricked.
- Always cut power before opening enclosure; power board capacitors hold high residual voltage, allow sufficient discharge time.
- Spare part procurement: Complete pull-out kits (RPU + DVI cable + MU-231CR) são preferidos; individual boards are scarce in supply.
- Post-repair commissioning: Re-integrate with FAR-28X7 radar; verify radar range scales and ARPA output parameters.
- Quick Fault Reference Table
| Sintoma | Highest Probable Failure Point |
| Lamp off, no unit response | Fonte de alimentação de entrada, internal fuse, power supply board |
| Lamp on, faint menu visible with flashlight | Backlight panel / backlight inverter |
| Lamp on, backlight on, No Signal message | RPU not ready, dedicated DVI cable damaged, RPU video output board |
| Intermittent black screen, recovers with vibration | DVI connector or loose screen cable |
| Black screen when cold, works after warming up | Ageing electrolytic capacitors on power board |
FURUNO MU-231CR Supporting Equipment Status Check (RPU-013, XN-12AF/20AF/24AF Antenna, RCU-014/015/016)
System chain: Antenna Unit → RPU-013 Radar Processor → Dedicated DVI Cable → MU-231CR. RCU is only for control and does not generate radar video.
Princípio Fundamental: MU-231CR itself does not generate radar signals. Radar image presence ultimately depends on whether RPU-013 outputs valid proprietary radar DVI video stream.
- RPU-013 Radar Processor (Maior prioridade)
1.1 Front Panel Indicator Interpretation
POWER LED: Steady green = Input power normal; OFF → Check RPU supply, internal fuse and power module.
RUN LED: Steady green after self-test completion = Normal operation;
Piscando: Self-test in progress, firmware loading or active fault alarm
Vermelho estável / piscando: Defeituoso, read fault code
ALARM LED: Red illuminated = active fault (antenna communication, transceiver, temperatura excessiva, video output, fã, ADC fault etc.)
✅ Normal healthy state: POWER steady green + RUN steady green + ALARM off. Allow 2–3 minutes post power-up for self-test before radar DVI output activates.
1.2 Two Methods to Retrieve RPU Fault Codes
- Método A (MU-231CR can display, only missing radar echo): Enter radar menu →【Alarm / Fault Log】to review fault history
- Método B (MU-231CR no signal / tela preta): Read 7-segment display or status LEDs on RPU mainboard, cross-reference FAR-28X7 service manual for fault definitions
Common alarm categories: antenna communication error, transceiver fault, over-temperature, falha do ventilador, DVI video output fault, ADC fault.
1.3 Verify RPU DVI Radar Output (Field Test)
Observação: Standard PC DVI monitor cannot decode this proprietary signal.
Doença 1: Confirmed good MU-231CR spare unit: swap in spare display. If spare shows radar picture → original MU-231CR faulty; spare still No Signal → RPU no video output.
Doença 2: Osciloscópio (professional service): Measure DVI differential clock and data waveform at RPU port. Clock present but no valid image data → RPU internal video board failure.
Doença 3: RPU internal fan observation: Fan should rotate smoothly after power-up. Stopped fan triggers over-temperature protection and cuts video output.
1.4 RPU Power Supply Check
RPU supply is typically AC100–230V. Medir a tensão terminal, check loose terminals, voltage drop and ship power harmonic noise.
RPU has separate internal fuse. Never short-circuit blown fuse; investigate downstream short circuit (antenna coaxial cable or transceiver assembly).
- XN-12AF / XN-20AF / XN-24AF Antenna Unit (Antenna + Transceiver)
Antenna faults fall into two categories: Antenna not rotating, Antenna rotates but no echo / communication loss
2.1 Mechanical Rotation Check
After RPU self-test completes, antenna should rotate at constant smooth speed (nominal ~24 rpm).
No rotation at all: Motor power supply, slip ring, drive circuit or RPU antenna communication fault.
Sticking, ruído anormal, intermittent rotation: Bearing seizure, slip ring oxidation and wear, motor failure.
⚠️ Aviso de segurança: Rotating radar antenna presents mechanical hazard; do not approach. X-band radar transmits RF energy; avoid standing close and facing antenna front during transmission.
2.2 Comunicação & RF Status
Antenna to RPU link: RF coaxial cable + multi-core control cable (slip ring harness).
RPU reports【Antenna Comm Error】: Control wire, slip ring and connector oxidation / open circuit are top causes.
Antenna rotates but no echo: Magnetron, transceiver module or modulator failure; magnetron degradation is a common consumable failure.
Basic judgement: Smooth rotation + no antenna communication alarm on RPU ≠ RF transmission is healthy. Communication link OK only; RF output power needs verification with RF power meter.
2.3 Antenna Temperature & Waterproof Inspection
Water ingress and condensation inside antenna housing cause RF short and slip ring corrosion. Check drain holes are clear. High internal temperature triggers antenna over-temperature protection and RPU transmission shutdown.
- RCU Control Unit: RCU-014 / RCU-015 / RCU-016 (Keyboard / Trackball)
Crítico: RCU failure will NOT cause black screen or missing radar image!
RCU is human-machine interface only, communicating with RPU over RS485 / proprietary serial bus. It does not carry radar video.
✅ Normal status indicators:
- RCU power indicator illuminates
- When MU-231CR displays radar picture, keys and trackball operate radar menu, change range scale and adjust gain.
❌ Fault symptoms: Picture normal, but keys unresponsive, trackball drift, menu cannot be controlled.
Solução de problemas: RCU power, serial communication cable, resistor de terminação, address setting. Multiple parallel RCU units with conflicting addresses will cause loss of control.
- Cable Link Inspection (Frequently Overlooked)
- RPU ↔ MU-231CR dedicated DVI cable: FURUNO custom radar cable; pin definition and timing differ from standard DVI. Visual check for bent pins, oxidation and jacket damage. Vibration test to reproduce intermittent dropout.
- RPU ↔ Antenna: Cabo de controle + RF coaxial: Water ingress and poor contact at coaxial connectors cause echo loss and antenna alarms. Perform VSWR standing wave ratio test; excessive VSWR indicates RF link fault.
- RPU ↔ RCU communication cable: Par trançado blindado, blindagem aterrada na extremidade única; incorrect grounding causes unstable communication.
- Standard Fast Diagnostic Workflow (Field Engineer Sequence)
- Full power cut for all equipment, rest 3 minutos para descarga do capacitor.
- Power sequence: Antenna unit → RPU-013. Wait 2–3 minutes for self-test completion, confirm RUN steady green, ALARM off and antenna starts rotation.
- Power MU-231CR and observe screen behaviour.
- Cross-test with spare MU-231CR to separate faults between【RPU no video output】and【display hardware failure】.
- If RPU persistently raises antenna alarm: Inspect antenna control wiring, slip ring and coaxial cable, antenna motor.
- Radar picture present but no control: Troubleshoot RCU communication circuit separately.
- Key Summary Table
| Componente | Failure can cause black screen / no radar image | Typical Healthy Status |
| RPU-013 | ✅ Sim (Highest frequency) | POWER green, RUN steady green, ALARM off, fan running, proprietary radar DVI output active |
| XN Antenna Unit | ✅ Sim (No echo, RPU alarm may cut video) | Smooth constant rotation, no antenna communication alarm on RPU |
| Dedicated DVI Cable | ✅ Sim | Connector intact, no bent pins, picture restored after swapping known good cable |
| RCU Control Unit | ❌ Não | Indicator lit; keys and trackball operate radar menu when picture is present |
- Supplementary Reminders
- Do not measure DVI differential signals with a multimeter; risk of burning driver chip. Cross-replacement test is preferred for qualitative diagnosis.
- Many RPU faults are intermittent: works cold, drops signal under navigation vibration. Focus inspection on slip ring, coaxial connectors and DVI interfaces.
- RF power and VSWR are metrology-grade tests requiring marine RF power meter / SWR bridge; standard multimeter cannot verify RF performance.
FURUNO MU Series Marine Radar Dedicated Display Unit List
Key Classification Rule:
MU-xxxCR = Radar-locked dedicated version (only accepts proprietary DVI signals from matched black-box radar RPU, no PIP, incompatible with standard PC / ECDIS multi-source inputs)
MU-xxx (without CR suffix) = Universal marine display, supports radar, ECDIS, echo sounder, camera inputs and PIP picture-in-picture
All models carry IMO Wheel Mark certification, designed for FAR-28X7 / FAR-21X7 / FAR-15X3 black-box radar systems. CR variants are factory-bundled with radar sets and not sold as standalone original spare units, circulated in used/refurbished spare markets.
Integrated radar (FR series, FAR all-in-one units with built-in screen) are excluded; these are not independent MU display units.
- Radar-Locked Dedicated CR Models (Primary Category for Your Application)
| Modelo | Tamanho da tela | Resolução | Matched Radar Processor | Notas | Status do ciclo de vida |
| MU-231CR | 23.1″ | UXGA 1600×1200 | RPU-013 (FAR-2807/2817/2827, FAR-2107/2127) | Single dedicated radar DVI only, no PIP, no composite / RGB input, auto light sensor | EOL, used/refurbished spare only |
| MU-201CR | 20.1″ | SXGA 1280×1024 | RPU-011 / Early FAR21XX black-box radar | Older 20-inch radar dedicated display, proprietary DVI interface | EOL, very limited stock |
| MU-190CR | 19″ | SXGA 1280×1024 | RPU-024 / FAR-1513-BB / FAR-1523-BB | 19-inch radar dedicated variant, multi-input locked by firmware | EOL, common on fishing / inland vessels |
| MU-170CR | 17″ | SXGA 1280×1024 | Early low-power black-box radar | Older 17-inch model, extremely scarce supply | EOL |
| MU-151CR | 15″ | XGA 1024×768 | Small fishing vessel black-box radar | Early compact radar dedicated display | EOL |
Suplemento: CR variants share identical mainboard hardware with same-number universal MU models. Difference is firmware input lock and proprietary protocol validation, only accepting matched RPU radar stream. Firmware cross-flash is prohibited and will brick the unit.
- Universal Marine Displays (MU non-CR suffix, compatible with radar, ECDIS etc.)
Universal models: Dual DVI, RGB, CVBS composite video, PIP, multi-source switching. Can connect to same RPU radar (but not recommended as direct drop-in replacement for CR on original FAR28X7 radar; timing and ARPA compatibility issues may arise).
| MU-152 | 15″ | XGA 1024×768 | AC100–230V | FR-CAR1/2, FAR-1513-BB, FAR-1523-BB | Vendas Ativas |
| MU-152HD | 15″ | XGA 1024×768 | CA/CC | High brightness sunlight-readable, fishing vessel black-box radar | Vendas Ativas |
| MU-190 | 19″ | SXGA 1280×1024 | AC100–230V | FAR-1513/1523, FAR-2258, FR-CAR | EOL, large installed base |
| MU-190HD | 19″ | SXGA 1280×1024 | CA/CC | High brightness, flybridge open-air installation | Vendas Ativas |
| MU-192 | 19″ | SXGA 1280×1024 | AC100–230V | Successor replacing MU-190, IMO certified | Vendas Ativas |
| MU-192HD | 19″ | SXGA 1280×1024 | CA/CC | Ultra-high brightness 1000 CD/m² | Vendas Ativas |
| MU-231 | 23.1″ | UXGA 1600×1200 | AC100–230V | FAR-28X7, FAR-21X7 (universal version) | EOL |
| MU-270W | 27″ Ecrã panorâmico | WUXGA 1920×1200 | AC100–230V | FAR-2xx8-NXT new-generation black-box radar, chart radar | Flagship Active Sales |
| MU-170C | 17″ | SXGA 1280×1024 | AC | Older 17-inch universal display | EOL |
| MU-201C | 20.1″ | SXGA 1280×1024 | AC | Older 20.1-inch universal display | EOL |
- MU-T Touch Series (New Bridge Integrated Displays, Not Direct MU-CR Replacement)
MU-170T: 17″ Tocar
MU-190T: 19″ Tocar
MU-240T: 24″ Tocar
Designed for integrated bridge systems, Ethernet MFD architecture. Not traditional DVI proprietary radar displays, cannot directly replace MU-231CR.
- Matched Radar Processor Cross Reference Table (Poupar & Sourcing Reference)
RPU-013 → MU-231CR / MU-231 (FAR2807/2817/2827)
RPU-024 → MU-190CR / MU-190 (FAR1513-BB / FAR1523-BB)
RPU-011 → MU-201CR (Legacy FAR2106 series)
SPU (FAR-2xx8-NXT new generation) → MU-270W
- Spare Replacement & Selection Critical Notes
- Original factory FAR28X7 radar ships with MU-231CR as standard. Do not directly substitute with universal MU-231; radar timing and ARPA compatibility risks exist, some radar revisions will reject the display.
- CR models reject PC and standard camera DVI sources and return No Signal; universal MU accepts multiple signal sources.
- Sourcing for discontinued CR models: Used pull-outs, refurbished units, old stock. New upgrade path is full radar system upgrade to FAR2xx8-NXT + MU-270W.
- Panel cutout dimensions: MU-231 and MU-231CR share identical cutout; MU-190 and MU-190CR share identical cutout.
- Excluded Models (Not Independent MU Radar Displays)
TZT Series (TZtouch): NavNet network MFD multifunction navigation terminal, not MU display
FR Series: Integrated radar (tela + transceiver built together), not standalone MU display
FMD Series: ECDIS chart plotters, not radar display units
Contator,disjuntor,sensor,Codificador,CLP,Conversor


















NH42-63-318x560.png)