Model Segment Definition Model Segment Meaning Description RS20 Product series identifier Hirschmann RS20 series compact open DIN-rail industrial Ethernet switch, design sem ventilador, suitable for industrial automation environments 1600 Port quantity 16 = total 16 portos; 00 = base model code S2 Uplink Port 1 type S = Single-mode fiber (SM); 2 = SC interface, 100BASE-FX ...

  • Detalhes do produto

Model Segment Definition

Segmento de modeloSignificadoDescrição
RS20Identificador da série do produtoHirschmann RS20 series compact open DIN-rail industrial Ethernet switch, design sem ventilador, suitable for industrial automation environments
1600Port quantity16 = total 16 portos; 00 = base model code
S2Porta de uplink 1 tipoS = Single-mode fiber (SM); 2 = SC interface, 100BASE-FX speed
T1Porta de uplink 2 tipoT = Twisted Pair (TP); 1 = RJ45 interface, 10/100BASE-TX speed
SDAPort configurationS = Standard port; D = 14 RJ45 data ports; A = Auto-negotiation / Auto MDI-X function
VocêSoftware versionU = Unmanaged; plug-and-play, no configuration required
HCTemperature grade & certificaçãoH = Wide temperature range (-40~+70℃); C = Compliant with industrial standards IEC 61850-3, UL 508, ISA 12.12.01, etc..
  1. Core Specification Table

Parâmetros Básicos

ItemEspecificação
FabricanteBelden Hirschmann
Número da peça.RS20-1600S2T1SDAUHC (Pedido nº.: 943 434-051)
Tipo de produto16-port unmanaged industrial Ethernet switch
Modo de comutaçãoStore-and-Forward
MontagemStandard NS 35/7.5 Montagem em trilho DIN
DimensõesW130mm × H90mm × D60mm
PesoAprox.. 650g
Material da HabitaçãoMetal, Classe de proteção IP20
ResfriamentoFanless, natural heat dissipation

Configuração da porta

ItemEspecificação
Total de portas16
Data Ports14 × 10/100BASE-TX RJ45, support auto-negotiation / auto MDI-X
Porta de uplink 11 × 100BASE-FX single-mode fiber SC port, transmission distance up to 15km
Porta de uplink 21 × 10/100BASE-TX RJ45, support auto-negotiation / auto MDI-X
Port FeaturesFull-duplex / Half-duplex support, 802.3x flow control
Cable TypeTwisted pair: Cat.5e and above, max 100m; Single-mode fiber: 9/125μm

Características Elétricas

ItemEspecificação
Power InputWide voltage: 12-48CCV, 24VAC(±10%)
Interface de energia1 × 6-pin pluggable terminal block, supports dual power redundancy
Consumo de energiaMax 15W
Proteção contra surtosCompatível com IEC 61000-4-5, diferencial / common mode protection
EMCEM 55032 Classe A, EM 55035, EM 61000-6-2

Mecânico & Environmental Characteristics

ItemEspecificação
Temperatura operacional-40~+70℃ (Wide temperature model)
Temperatura de armazenamento-40~+85℃
Umidade5~95%RH (Non-condensing)
Resistência à vibração5-150Hz, 1g (CEI 60068-2-6)
Resistência ao choque15g (11EM) (CEI 60068-2-27)
CertificaçõesCE, cUL508, ISA 12.12.01, Aula 1 Div 2, CEI 61850-3
  1. Lista de acessórios

Standard Accessories

  1. RS20-1600S2T1SDAUHC switch main unit
  2. Pre-installed DIN rail mounting clips
  3. Pre-installed 6-pin power terminal block
  4. User manual (cópia impressa / electronic version)
  5. Product certification documents

Acessórios opcionais

Nome do acessórioModeloDescrição da função
Redundant Power ModuleRPS-24DCProvides dual redundant power input to improve system reliability
Fiber Patch CordSC-SC Single-mode 9/125μmFiber connection for Uplink Port 1
Power Cable12-48CCVMatches switch power input
Marker StripRS20-MARKPort labeling for easy maintenance and troubleshooting
Capa contra poeiraRS20-DUSTProtects unused RJ45 and SC ports
Suporte de montagemRS20-BRACKETParede / panel mounting instead of DIN rail
  1. Competitor & Comparação entre marcas

Same Series Comparison (Hirschmann RS20 Series)

ModeloConfiguração da portaUplink PortsVersão do softwareTemperature GradeCenário de aplicação
RS20-1600S2T1SDAUHC14×RJ45+1×SM SC+1×RJ45Single-mode SC + RJ45Não gerenciado (Você)Wide -40~+70℃Long-distance fiber uplink, harsh industrial environments
RS20-1600M2M2SDAUHC14×RJ45+2×MM SCDual Multi-mode SCNão gerenciado (Você)Wide -40~+70℃Short-distance fiber uplink, automação predial
RS20-1600T1T1SDAUHC14×RJ45+2×RJ45Dual RJ45Não gerenciado (Você)Wide -40~+70℃Pure copper cable connection, simple network topology
RS20-1600S2S2SDAEHC14×RJ45+2×SM SCDual Single-mode SCBasic Managed (E)Wide -40~+70℃Basic network management required, long-distance fiber

Comparação entre marcas

Marca & ModeloConfiguração da portaUplink PortsVersão do softwareFaixa de temperaturaCaracterísticasNível de preço
Hirschmann RS20-1600S2T1SDAUHC14×RJ45+1×SM SC+1×RJ45Single-mode SC + RJ45Não gerenciado-40~+70℃Temperatura ampla, sem ventilador, complete industrial certificationsMid-to-high
Phoenix Contact FL SWITCH SF 16TX/1SM15×RJ45+1×SM SCSingle-mode SCNão gerenciado-40~+70℃Redundant power, reliable Phoenix qualityMid-to-high
MOXA EDS-2016-1M-S-SC15×RJ45+1×SM SCSingle-mode SCNão gerenciado-40~+75℃Extended wide temp, IP30 protectionMid-range
Schneider Electric TCSESM0163F2CU14×RJ45+2×SM SCDual Single-mode SCNão gerenciado-25~+70℃Seamless integration with Schneider PLCMid-range
Advantech EKI-2526SI16×RJ45 (2 SFP slots)Expandable fiberNão gerenciado-40~+75℃Flexible SFP configuration, econômicoMid-range
  1. Diretrizes de seleção & Soluções Alternativas

Considerações sobre seleção de chaves

  1. Port Type: Select uplink port type (single/multi-mode fiber, RJ45) according to network topology; single-mode for long distance (>2quilômetros), multi-mode for short distance (<2quilômetros).
  2. Software Function: Não gerenciado (Você) for simple plug-and-play scenarios; Managed (E/P) for complex networks requiring VLAN, QoS, ring redundancy.
  3. Faixa de temperatura: Wide-temperature model (H) for outdoor, high-temperature workshop and harsh environments; standard model for general indoor industrial sites.
  4. Power Requirement: Confirm whether dual power redundancy is needed to enhance system reliability.
  5. Certificação: Select products compliant with IEC 61850-3, UL 508, ISA 12.12.01 based on regional and industry standards.

Modelos alternativos recomendados

Cenário de aplicaçãoModelo recomendadoReason for Replacement
Short-distance fiber uplink (<2quilômetros)RS20-1600M2M2SDAUHCLower cost multi-mode fiber, suitable for intra-factory and building connection
Pure copper cable, no fiber requiredRS20-1600T1T1SDAUHCDual RJ45 uplink for simple network topology and cost saving
Basic network management requiredRS20-1600S2T1SDAEHCSupports VLAN, QoS, HIPER-Ring ring redundancy (tempo de recuperação <300EM)
Budget-sensitive, cost performance priorityMOXA EDS-2016-1M-S-SCSimilar functions, more affordable price and wider temperature range
Existing Phoenix Contact systemPhoenix Contact FL SWITCH SF 16TX/1SMHigh system compatibility and shared accessories

Technical Advantages Summary

Fanless Design: Maior confiabilidade, lower maintenance cost, suitable for dusty environments.

Wide Temperature Range: -40~+70℃ operating temperature, adaptable to harsh industrial conditions.

Plug-and-Play: Unmanaged design, no configuration needed, fast deployment.

Complete Industrial Certifications: Compatível com IEC 61850-3, UL 508, ISA 12.12.01, ideal for power, rail transit and other industries.

Tamanho compacto: 130mm width saves cabinet space and supports high-density installation.

How to Select Hirschmann Industrial Ethernet Switches According to Actual Requirements

Below is a standardized 7-step selection process applicable to engineering projects, together with series positioning, industry matching and common selection pitfalls.

Etapa 1: Confirm Mounting Method

Determine the product series directly:

  1. DIN Rail Mount (Most control cabinets & automation production lines)

Choose: RS20 / RS30 / RS40 compact series

  1. 19-inch Rack Mount (Central control room & power distribution core cabinet)

Choose: MACH100 / MACH4000 rack-mounted series

  1. Outdoor Wall Mount / Cabinet-Free (Outdoor base station, tunnel, pumping station)

Choose: OCTOPUS IP65/IP67 waterproof series

  1. Panel Embedded Mount (Built-in equipment)

Choose: EAGLE / dedicated panel type

Etapa 2: Confirm Port Quantity, Port Type & Velocidade

Total Port Quantity

Count PLC, HMI, instrument and camera quantities on site, reserve 20% redundância.

Comum: 4-port / 8-port / 16-port / 24-port.

Port Type (Core Selection Point)

RJ45 Copper Port: Indoor short distance ≤100m, standard network cable

Fiber Port: Longa distância & forte anti-interferência

Multi-mode (Milímetros): ≤2km, intra-factory & building interconnection, baixo custo

Single-mode (SM): ≥5~15km, cross-plant road, power remote transmission, outdoor

SFP Slot: Hot-pluggable Gigabit/100M fiber module, expansão flexível; recommended for mid-to-high-end projects.

Velocidade

Ordinary PLC, instrument & monitoramento: 10/100M Fast Ethernet is sufficient

Machine vision, big data, multi-camera & core aggregation: Gigabit completo

Etapa 3: Select Management Mode

Three grades based on network complexity:

  1. Não gerenciado

Características: Plug-and-play, zero configuration

Aplicativo: Single device, simple production line, no network partition or ring redundancy

Sufixo: Você

  1. Managed Lite

Supports VLAN, QoS, port rate limiting, basic ring network

Aplicativo: Multi-workshop partition, simple isolation & basic redundancy

  1. Full Managed

Supports HIPER-Ring, MRP, RSTP, IGMP multicast, network security, port mirroring, fault alarm

Aplicativo: Poder, rail transit, smart factory, ring topology, high reliability non-stop network

Etapa 4: Select Operating Temperature Grade

  1. Standard Temperature: 0℃~+60℃

Aplicativo: Air-conditioned central control room, constant temperature cabinet

  1. Wide Temperature: -40℃ ~ +70 ℃

Aplicativo: High-temperature workshop, outdoor, non-air-conditioned cabinet, cold northern & hot southern environments

Industrial sites are recommended to choose wide-temperature models for higher fault tolerance.

Etapa 5: Power Specification & Redundancy

  1. Tensão: Industrial standard 24VDC, some support 12~48VDC wide voltage
  2. Dual Power Redundancy: Mandatory for key production sections, power and rail transit; avoids network outage from single power failure
  3. Proteção: Reverse polarity protection & surge immunity; prioritize industrial EMC protection for harsh power environments

Etapa 6: Network Redundancy & Special Application Requirements

  1. Ring Network Self-healing (Network remains online when one cable breaks)

Must choose managed switches supporting HIPER-Ring / MRP / RSTP

  1. Network segmentation & device isolation → Require VLAN
  2. Multiple cameras & streaming media → Require IGMP multicast
  3. Industrial security & unauthorized access prevention → Require port security & MAC binding

Etapa 7: Classe de Proteção & Certificação da Indústria

  1. Classe de Proteção

Instalação de gabinete: Standard IP20

Ar livre, empoeirado & humid site: IP65/IP67 OCTOPUS series

  1. Industry-Specific Certification

Indústria de energia: Mandatory IEC 61850-3

Trânsito ferroviário: EM 50155

Marinho & offshore: Ship classification certification

Explosion-proof chemical industry: Explosion-proof grade certification

Hirschmann Main Series Positioning

SériePosicionamentoCenário de aplicação
RS20Entry-level compactSmall production line, ordinary control cabinet, mostly unmanaged, conventional budget
RS30Mid-range mainstreamGigabit SFP, basic management, pequeno & medium factory ring network, econômico
RS40High-end industrialGigabit completo, full-featured management, power/rail transit/high-end smart factory
MACH100/4000Rack-mounted core19-inch cabinet machine room, plant-level core aggregation switch
OCTOPUSOutdoor waterproofAr livre, tunnel, pumping station, cabinet-free on-site installation

Industry Recommended Selection

  1. General Automation Production Line / Workshop

8/16-port RS20 wide-temperature unmanaged — cost-effective and sufficient

  1. Multi-workshop Ring Network / Smart Factory

RS30 Gigabit SFP managed with ring network support

  1. Power Substation / VP & Wind Power

RS40 wide-temperature + IEC61850 certification + dual power redundancy

  1. Rail Transit / Tunnel Outdoor

OCTOPUS IP67 waterproof + temperatura ampla + rail transit certification

  1. Central Control Room Core Aggregation

MACH rack-mounted full Gigabit

Common Selection Pitfalls

  1. Do not blindly choose full Gigabit; 100M is enough for ordinary PLC and wastes budget.
  2. Avoid standard temperature models for industrial sites; cabinet overheating easily occurs in summer.
  3. Use single-mode fiber ports for long-distance cross-plant connection; do not use network cables for long-distance laying.
  4. Ring topology must use managed switches; unmanaged switches cannot implement ring redundancy.
  5. Key equipment must adopt dual power redundancy to prevent entire network paralysis from single power failure.

Anterior:

Deixe uma resposta

Deixe um recado