KEYENCE KV-C32XA Input Expansion Module - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 KEYENCE KV-C32XA Input Expansion Module - Contator,disjuntor,sensor,Codificador,CLP,Conversor

CLP/

KEYENCE KV-C32XA Input Expansion Module

Tipo: 32-point DC input expansion module (MIL connector type), Discontinued Compatible PLC Series: KV-5000 / KV-7000 / KV-8000 Core Specifications I/O Type: Entrada Digital, 32 points Wiring: MIL standard connector Input Mode (selectable via software): CC24V / DC5V Maximum Input Voltage: DC26.4V DC24V Mode: Rated 24V, 5.3mA; ON ≥ 19V; OFF ≤ 1.5V DC5V Mode: ...

  • Detalhes do produto

Tipo: 32-point DC input expansion module (MIL connector type), Descontinuado

Compatível CLP Série: KV-5000 / KV-7000 / KV-8000

Especificações principais

Tipo de E/S: Entrada Digital, 32 pontos

Fiação: MIL standard connector

Input Mode (selectable via software): CC24V / CC5V

Maximum Input Voltage: DC26.4V

DC24V Mode: Rated 24V, 5.3mA; ON ≥ 19V; OFF ≤ 1.5V

DC5V Mode: Rated 5V, 1mA; ON ≥ 3.5V; OFF ≤ 1.5V

Terminal Comum: 1 common group for all 32 pontos (2 COM terminals)

Input Filter Time: 3 selectable settings (25μs / 1EM / 10EM)

Internal Current Consumption: ≤15mA

Certificações: UL, CSA

Seleção de modelo & Referência de substituição

Replacement options with MIL connector for 32-point input:

KV-C32XTD (new high-speed input model, supports 5V/24V input)

Observação: KV-C32XA is input-only, sem saída. Do not confuse it with KV-C32TA (32-point transistor output module).

Acessórios compatíveis

Cabos: OP-series MIL cables, relay terminal blocks

Tampa final: OP-84203 (KV bus terminator unit)

Notas Suplementares

  1. Apenas estoque / used units available after discontinuation; not recommended for new projects.
  2. 5V mode is used for encoder and TTL level signal acquisition; 24V mode for conventional NPN sensors.
  3. Single common terminal for all 32 pontos; no isolated grouping support.

Typical Engineering Application Cases of KV-C32XA

Recap of key features: 32-point MIL connector input, dual DC24V / DC5V TTL mode, minimum 25μs high-speed filter, single COM terminal. Compatible with KV-5000/7000/8000. Descontinuado, mainly used for retrofitting old equipment and spare part replacement. 5V mode is its biggest advantage compared with ordinary 32-point input modules.

Caso 1: Multi-station Fixture Tooling (24V mode, mais comum)

Equipment Type: Consumer electronics PCB test fixtures, multi-channel pressing fixtures

Configuração de hardware: KV-8000 CPU + KV-C32XA + Solenoid valve output module

Connected Signals: 32-point DC24V NPN sensors

Fibra / diffuse photoelectric sensors: workpiece presence, position confirmation

Magnetic switches: cylinder home and end-position signals

Interruptores de limite, parada de emergência, portão de segurança, manual pushbuttons

Implementação: MIL plug directly connected to internal fixture wiring, no heavy terminal blocks required for quick fixture swap and pluggable wiring. 32-point centralized signal acquisition for interlock, mistake-proofing and NG judgment in PLC program.

Pros & Cons: Compact fixture space, concentrated I/O, troca rápida; downside: shared COM for all 32 points without isolation. Short circuit on one channel affects the whole module.

Caso 2: Codificador / TTL Pulse Signal Acquisition (5V mode, signature application)

Equipment Type: Precision displacement stages, optical inspection platforms, semiconductor dicing machines

Configuração de hardware: KV-7000 + KV-C32XA (set to DC5V mode)

Connected Signals: Single-ended TTL A/B phase, Z zero-index, latch trigger signals converted from differential signals

Multiple incremental encoders (single-ended 5V)

5V trigger, preparar, judgment signals from cameras and laser rangefinders

32-bit parallel status words output from FPGA / motion control boards

Vantagem: 25μs high-speed filter for high-frequency TTL signals. Ordinary 24V input modules cannot accept 5V level directly. This was the main reason for selecting KV-C32XA in the past.

Cuidado: Only supports single-ended TTL; differential signals require prior conversion. Critical to share the same ground between encoders and the PLC controller.

Caso 3: Aggregated Judgment Signals for Vision Inspection Stations (24V)

Equipment Type: Multi-camera vision inspection machines, AOI appearance inspection equipment

Configuração de hardware: KV-5000 + 2 × KV-C32XA

Connected Signals: Judgment output, buffer full, trigger request, falta, light ready, scan OK/NG signals from multiple vision controllers (KEYENCE 4, XG series), plus material in-position and cylinder magnetic switch signals.

Lógica: Collect decentralized vision judgment signals into PLC for sorting, contando, traceability and MES upload.

Engineering Practice: MIL cables routed to relay boards inside the vision cabinet to reduce scattered wiring.

Caso 4: Reforma & Spare Parts Replacement for Existing Production Lines (Most common for legacy assets)

Cenário: Old KV-5000/7000 assembly lines, injection molding robots and packaging lines originally fitted with KV-C32XA. Damaged modules replaced by stock / unidades de segunda mão.

Original equipment uses prefabricated MIL harnesses; high modification cost if switching to screw-terminal 32X modules.

Selection reminder: New projects prefer KV-C32XC / KV-C32XTD; KV-C32XA is only used for legacy lines without harness modification.

Aviso de risco: Stock is scarce after EOL. Verify 5V level threshold and filter parameters after delivery to avoid mismatches with original program logic.

Caso 5: Parallel IO Code Disk, Matrix Keypad / Selector Switch Acquisition (5V mode)

Equipment Type: Test sorters, programmable test benches, probe stations

Uso: Read 32-bit binary status from a board in parallel at 5V level with high-speed latching. Used to read multi-channel relay matrix and channel selection codes.

Vantagem: Ler 32 bits in one cycle, faster than RS485 polling. Suitable for test stations requiring synchronous sampling.

Caso 6: Posição, Stopper and Material Sensor Acquisition for Conveyor Sorting Lines (24V mode)

Equipamento: Small belt sorters, material box recirculation lines

Connected Signals: Material presence, stopper position, diverter cylinder, grating, overflow alarm, manual reset buttons. 32-point I/O concentrated at the sorting head; MIL plug allows whole sorting head disassembly.

Seleção & Commissioning Troubleshooting Summary (Field Experience)

  1. Mode change via software only: CC24V / 5V is set in KV Studio unit parameters, no hardware jumper. Wrong mode setting causes unstable or missing signals.
  2. Single COM limitation: 1 common terminal for all 32 pontos. NPN and PNP cannot be mixed on one module; channel isolation is impossible. Use separate modules if isolation is required.
  3. 5V mode still rated max DC26.4V: Direct 24V wiring under 5V mode burns input channels.
  4. 25μs high-speed filter is sensitive to noise. Use 1ms / 10ms filter for long cables or near large motors.
  5. MIL connectors have limited mechanical life. Frequent fixture plugging causes poor contact from oxidation; most failures are connector issues rather than module damage.

Complete List of KEYENCE KV Series Digital Input Expansion Modules

Observação: Only input-only modules (sem saída). Separated into discontinued XA series, current XC local expansion series, KV-N / NC remote EtherNet/IP I/O input units. E/S mista (XTD/EXT), contador de alta velocidade, analog and temperature modules excluded. CPUs compatíveis: KV-5000/7000/8000

  1. Discontinued XA Series (MIL connector)
ModeloPontosFiaçãoInput SpecObservações
KV-C16XA16MIL connectorCC5V / DC24V software selectableDescontinuado
KV-C32XA32MIL connectorCC5V / DC24V software selectableDescontinuado, modelo de destino
KV-C64XA64Dual MIL connectorSomente DC24V, supports 2-wire sensorsDescontinuado, 32 points per COM group

XA replacement: XC series of same point count (KV-C32XC replaces KV-C32XA)

  1. Current XC Series (Local backplane expansion, mainstream active models)
ModeloPontosFiaçãoInput Spec
KV-B16XC16Removable screw terminalCC5V / DC24V software selectable
KV-C32XC32MIL connectorCC5V / DC24V software selectable
KV-C64XC64Dual MIL connectorSomente DC24V
  1. KV-N / KV-NC Remote EtherNet/IP Input Units (E/S distribuída)
ModeloPontosFiaçãoInput Spec
KV-N8EX8Terminal de parafusoCC24V
KV-N16EX16Terminal de parafusoCC5V / DC24V selectable
KV-NC16EX16MIL connectorCC5V / DC24V selectable
KV-NC16EXE16European terminalCC5V / DC24V selectable
KV-NC32EX32MIL connectorCC5V / DC24V selectable
KV-NC32EXE32European terminalCC24V

Confusable Models (NOT input-only modules)

KV-C16XTD / KV-C32XTD: E/S mista (entrada + saída)

KV-NC16EXT / KV-NC32EXT: Remote mixed I/O

KV-SIR32XT: High-speed synchronous I/O unit (high-speed input + saída, motion dedicated, not general DI)

KV-SSC02: High-speed counter unit, not general digital input

Quick Replacement Table (XA → XC)

KV-C16XA → KV-B16XC (terminal) / KV-NC16EX (remote connector)

KV-C32XA → KV-C32XC (MIL connector, preferred replacement)

KV-C64XA → KV-C64XC

Installation Guide for KEYENCE KV‑5000/7000/8000 Local Input Expansion Modules (KV‑C32XA / C32XC / B16XC etc.)

Regra Crítica: Power off before all installation and removal. Hot-swap is strictly prohibited. Hot-swap triggers bus error and damages backplane connectors.

  1. Ambiente de instalação & Montagem em trilho DIN
  2. Condições Operacionais: 0~55℃, humidity 5%~95%RH non-condensing. Mantenha-se longe da poeira, gás corrosivo, strong electromagnetic interference and oil splash. Altitude ≤2000m.
  3. Cooling Clearance: Reserve ≥30mm space top, bottom and side of modules. Install vertically inside cabinet; avoid upside-down or horizontal mounting.
  4. Trilho DIN: Trilho DIN padrão de 35 mm. Align the rear latch with rail and press down to lock. Lift the release tab at bottom to detach.
  5. Aterramento: FG terminals of cabinet, CPU and modules connect to class D ground, resistência à terra ≤100Ω. Single-ended shield grounding for signal cables.
  6. Backplane Bus Daisy-chain Installation (Local expansion for XA/XC)

Sequência: CPU → chained expansion modules → Termination cover OP‑84203 must be fitted on the last module

  1. Remove the protective cover on CPU right-side expansion port (keep the cover for future disassembly).
  2. Each module has expansion bus connectors on both sides: Left connector mates with previous unit, right connector mates with next unit.
  3. Align modules, insert vertically and fully engage bus connectors. Do not force at an angle, which may bend pins.
  4. Module arrangement: Entrada, output and special modules after CPU. Total expansion count cannot exceed the CPU maximum supported unit limit.
  5. Bus termination: Fit OP‑84203 termination cover on the right port of the last module in the chain. Missing termination causes unstable bus, intermittent module dropout and unit error alarms.

Observação: XA/XC are local backplane I/O. KV‑NC series are EtherNet/IP remote I/O and do NOT use this backplane daisy-chain method.

  1. External I/O Wiring (KV‑C32XA as MIL example)
  2. Confirm mode first: CC24V / DC5V TTL configured via KV Studio, no hardware DIP switch. Define before power-on. 24V applied under 5V mode burns channels.
  3. COM Common: C32XA uses one COM group for all 32 pontos. Sensores NPN: COM para 0V; Sensores PNP: COM to 24V+. NPN and PNP cannot mix on one module.
  4. MIL Plug: Use OP-series MIL cables. Insert straight into module MIL socket and lock the latch. Do not pull cables to bear mechanical load.
  5. Cable Separation: Separate high-power cables (solenóides, fiação de energia) and MIL signal cables by ≥100mm. Use shielded cable for long-distance or high-speed 5V TTL signals to reduce interference.
  6. Fonte de energia: Module is powered by PLC backplane bus, no separate power supply required for the module. Sensor power (24V/5V) comes from external independent power supply, common ground with PLC power supply.
  7. Configuração de Software (KV Studio)
  8. Complete hardware installation and wiring, double-check before power-up.
  9. Open KV Studio, enter Unit Editor.
  10. Add CPU and expansion modules (por exemplo. KV‑C32XA) in exactly the same physical order as installed.
  11. Select the input module, open unit parameters: set input mode (24V / 5V), tempo de filtro (25μs / 1EM / 10EM).
  12. Download project to PLC, restart PLC. Enter monitor mode to confirm module LED status, no ERR alarm, and DI points can monitor signals normally.
  13. Supplementary Installation for Remote Input Modules (KV‑NC16EX / NC32EX etc.)

These are EtherNet/IP remote I/O and do not connect to CPU backplane bus:

  1. Montagem em trilho DIN, power off for wiring.
  2. Remote module powered independently by DC24V.
  3. Ethernet cable to EtherNet/IP bus, follow EtherNet/IP bus termination rules.
  4. Import EDS file and configure I/O mapping in KV Studio EtherNet/IP setup.
  5. Procedimento de remoção
  6. Power off the whole PLC system.
  7. Disconnect external MIL / terminal signal wires first.
  8. Start from the last module: remove termination cover, then disconnect bus connectors between modules sequentially.
  9. Lift DIN rail latch and remove module from rail.
  10. Refit protective covers on unused bus ports.
  11. Common Installation Faults
  12. Missing termination cover → random unit error, modules detected intermittently.
  13. Mismatch between physical module order and software configuration → unit mismatch error.
  14. 24V wired under 5V mode → channel burnout.
  15. Forced angled insertion of bus connector → bent pins and poor contact.
  16. No common ground for 5V TTL signals → signal jitter and false triggering.
  17. Signal cables run together with power cables → noise and erratic signal at 25μs high-speed filter setting.