Pepperl+Fuchs UC2000-F43-2KIR2-V17 sensor

Item nº.: 120329 | Status do produto: Obsoleto (Discontinued by Manufacturer) Model Code Breakdown `UC2000-F43-2KIR2-V17` UC2000: UC series ultrasonic sensor, maximum measuring distance 2000 mm F43: Flat rectangular housing (F-type enclosure) 2K: 2 relay contact outputs I: Analogue 4…20 mA current output R2: Built-in RS232 interface for parameter programming V17: Hardware version V17 Core Technical Specifications ...

  • Detalhes do produto

Item nº.: 120329 | Status do produto: Obsoleto (Discontinued by Manufacturer)

  1. Detalhamento do código do modelo

`UC2000-F43-2KIR2-V17`

  1. UC2000: UC series ultrasonic sensor, maximum measuring distance 2000 milímetros
  2. F43: Flat rectangular housing (F-type enclosure)
  3. 2K: 2 relay contact outputs
  4. EU: Analogue 4…20 mA current output
  5. R2: Built-in RS232 interface for parameter programming
  6. V17: Hardware version V17
  7. Especificações Técnicas Principais

Ranging Performance

ItemEspecificação
Effective measuring range100 … 2000 milímetros
Blind zone (dead zone)0 … 100 milímetros
Transducer frequencyAprox.. 175 kHz
Standard reflector target100×100 mm flat plate
Measurement resolution0.5 milímetros
Non-linearity error<0.2% of full scale
Repeat accuracy≤0.1% of full scale
Programmable hysteresis0~15% of measuring range adjustable

Dados elétricos

Tensão de alimentação:

Without analogue output: 10…30 VCC; With 4–20mA activated: 15…30 VCC

No-load power consumption: ≤0.7 W; Máx.. full-load power consumption: ≤2 W

Output Combination (Key Feature)

✅ 2 independent relay outputs (SPDT changeover contacts)

Avaliação de contato: 60 CCV / 1 UM (carga resistiva, máx.. 24 W DC)

✅ 1 analogue 4 … 20 saída mA, maximum load impedance ≤500 Ω

Comunicação: RS232, 9600bps, 8N1. Parameter configuration via UC-PROG1-USB and ULTRA2001 software

Tempo de resposta: Mínimo. ≤50ms; Factory default ≤150 ms

Mecânico & Especificações Ambientais

Conexão: M12×1 8-pin male connector

Classe de proteção: IP65

Housing material: PBT thermoplastic

Temperatura operacional: -25 ℃ ~ +70 ℃

Temperatura de armazenamento: -40 ℃ ~ +85 ℃

Peso: 290 g

Built-in temperature compensation

Indicação de status LED

Green LED steady ON: Target within measuring window; Green LED flashing: No target detected

Red LED ON: Fault condition (high acoustic interference, erro de fiação, etc.)

  1. M12 8-Pin Pin Assignment
AlfineteDefinição
1DC+ Power Positive
2Relé 1 Terminal Comum
3CC- Power Negative
4Relé 2 Terminal Comum
54~20mA Analogue Signal Output
6Relé 1 Normalmente aberto / Normalmente fechado
7Relé 2 Normalmente aberto / Normalmente fechado
8Escudo (Housing Earth) + RS232 Communication

⚠️ Important Note: When using the 4–20mA output, supply voltage must not drop below 15 CCV; otherwise analogue output malfunction will occur.

  1. Campos de aplicação típicos
  2. Warehouse & Logística: Level height detection, pallet presence detection, anti-collision distance measurement
  3. Máquinas de embalagem: Roll diameter measurement, material presence monitoring
  4. Tratamento de Água: Non-contact level measurement for open tanks
  5. Automação Geral: All-in-one solution for dual limit switching + continuous distance transmission

Vantagem: Single sensor delivers two limit switch signals + continuous distance feedback, saving installation space.

  1. Opções de substituição (Critical Section)

No direct pin-to-pin upgraded model available with original F43 flat housing. Two selection options:

Option 1: Functional Equivalent (Requires modified mounting bracket & electrical adaptation)

UC2000-L2-IUR2-V15

Measuring range: 100…2000 mm

Resultados: 4–20mA analogue + 2 PNP switching outputs + RS232

Diferença: Saída transistorizada, no relay contacts; Cylindrical housing with different mounting dimensions

If passive relay contacts are mandatory on site, select third-party ultrasonic sensor paired with external relay.

Option 2: Maintain Relay Output

Only used / refurbished stock available for legacy series. Para novos projetos:

UC2000-L2-IUR2-V15 + auxiliary miniature relay for contact conversion.

  1. Seleção & Diretrizes de Operação / Pitfall Avoidance
  2. Blind Zone Limitation: Reliable measurement impossible within 100 milímetros; Do not select for close-range applications.
  3. Acoustic Cone Interference: Activate sensor synchronisation function when multiple sensors are installed side-by-side to prevent mutual ultrasonic interference.
  4. Medium Limitation: Soft foam, fluffy fabrics produce weak echo and lead to unstable detection.
  5. Relay Service Life: Electrical service life limited to 3×10⁵ switching cycles. Not suitable for high-frequency switching applications. Transistor output models are recommended for frequent operation.
  6. Programming Requirement: Adjustment of switching points, measuring range and hysteresis requires UC-PROG1-USB programming cable. No external teach-in button available.
  7. Matriz de solução de problemas
Sintoma de falhaCausa raizAção Corretiva
Analogue output locked at 4mA / 20mATarget out of measuring range / Undersupply voltageVerify supply ≥15 VDC; Confirm target is within 100~2000 mm range
Relay triggers falsely and frequentlyAcoustic reflection interference, insufficient hysteresis settingIncrease hysteresis parameter; Install separation baffles; Enable synchronisation mode
Red LED continuously illuminatedOndulação excessiva da fonte de alimentação / Internal sensor failureAdd power supply filter; Check shielding wiring of pin 8
Communication connection failureIncorrect RS232 wiring, mismatched baud rateConfirm 9600,8N1 setting; Use original UC-PROG1 adapter

Pepperl+Fuchs UC2000-F43-2KIR2-V17 Practical Application Cases

Core Feature Recap (All cases based on unique strengths of this model)

Flat F43 rectangular housing, measuring range 100~2000 mm;

2 SPDT passive relay contacts + 4…20mA analogue output + RS232 programmable interface;

Highlight: Single sensor integrates dual limit switching + continuous distance transmission. Passive relay contacts can directly drive contactors and audible/visual alarms. Flat housing fits confined mounting spaces; IP65 rated with built-in temperature compensation.

Important Reminder: This sensor is discontinued by the manufacturer. Alternatives are recommended for new projects. The below cases are proven historical applications.

Cse 1 | Tratamento de Águas Residuais: Level Monitoring & Pump Control for Open Settling Tank

Working Conditions

Open regulating tank in small wastewater treatment plant with surface foam and high humidity. Requisitos:

① Continuous level signal transmitted to PLC via 4–20mA;

② Low-level pump start, high-level pump stop (two relays directly control contactors to reduce PLC point consumption);

③ Limited installation space above tank guardrail, cylindrical sensors cannot be fitted.

Implementation Scheme

Sensor installed horizontally with downward tilt above the tank, avoiding severe foam zones.

Relé 1: High level limit (1.6 eu) → Trigger to stop drainage pump

Relé 2: Low level limit (0.4 eu) → Trigger to activate water inlet

4–20mA signal sent to central control for real-time liquid level display

RS232 used on-site to calibrate measuring range and hysteresis, suppressing frequent fluctuation caused by water ripples.

Reason for Model Selection

Flat F43 housing compatible with narrow mounting brackets; Passive relays drive contactors directly without additional auxiliary relays. Ultrasonic measurement immune to water colour and mild foam.

Risk Notes

Thick foam absorbs ultrasound; proper mounting tilt required. Blind zone of 100 mm prevents low-level alarm setup near tank bottom.

Caso 2 | Plastic Extrusion Industry: Residual Roll Diameter Monitoring for Film / Nonwoven Web

Working Conditions

Continuous unwinding of raw material rolls on cast film production line. Control system requirements:

  1. Real-time roll outer diameter measured; 4–20mA signal sent to tension controller for automatic unwinding torque regulation;
  2. Dual limit: Low material pre-warning + complete roll depletion safety shutdown.

Implementation Scheme

Sensor mounted laterally on machine frame, aligned horizontally with roll outer surface; 0.1~2m measuring range matches maximum roll diameter.

Relé 1: Minimum roll diameter reached (pre-warning) → Audible & visual alarm for material preparation

Relé 2: Roll diameter hits minimum limit → Full production line safety shutdown

Continuous 4–20mA analogue distance output for roll diameter conversion and closed-loop tension control.

Selection Advantage Comparison

Conventional transistor-output sensors rely on PLC logic for dual alarm functions. Built-in relays enable direct wiring to alarm circuits for legacy retrofit projects without modifying PLC programs.

Operation Tip

Surface wrinkles and web vibration cause signal fluctuation; configure sufficient measurement hysteresis via software.

Caso 3 | Logistics Conveyor Line: Pallet Height Detection & Dual Position Limit

Working Conditions

Roller conveyor for automated warehouse transporting wooden / plastic pallets. Photoelectric sensors prone to false triggering caused by dust and pallet gaps. Requisitos:

① Confirm pallet arrival (near-point switch);

② Overheight pallet detection to prevent jamming in vertical lift;

③ Real-time pallet height data uploaded to WMS for cargo dimension verification.

Implementation Scheme

Sensor side-mounted above conveyor channel:

Relé 1: Pallet arrival confirmation signal

Relé 2: Pallet overheight alarm, trigger conveyor emergency stop

4–20mA output of measured pallet height sent to upper system for cargo dimension validation.

Valor Central

Slim flat housing embedded into narrow side space of conveyor. Ultrasonic detection unaffected by pallet holes and dust; passive relay contacts compatible with legacy safety circuits.

Caso 4 | Chemical Raw Material Hopper: Granular Level Monitoring (Plastic Pellets, Calcium Carbonate)

Working Conditions

Open-top raw material hopper for small extruders. Heavy dust environment unsuitable for capacitive level switches. Requisitos:

Low-level pre-warning, high-level full hopper shutdown, plus continuous level monitoring.

Implementation Scheme

UC2000-F43 installed laterally at hopper top:

Relé 1: High material level → Stop feeding conveyor motor

Relé 2: Low material level → Start raw material feeding conveyor

4–20mA signal transmitted to central control for daily raw material consumption tracking.

Precauções

Severe dust clouds attenuate ultrasonic echo; avoid vertical installation facing falling material stream.

Caso 5 | Máquinas de construção / AGV: Anti-collision Distance Warning System

Working Conditions

Indoor factory Automated Guided Vehicle (AGV). Dual-stage collision protection required:

  1. Long-distance pre-warning (speed reduction); 2. Short-distance emergency stop; Continuous distance signal sent to on-board controller.

Implementation Scheme

Flat-mounted F43 sensor on AGV outer body (cylindrical sensors protrude and risk collision damage). Measuring range 100~2000 mm:

Relé 1: 1.2 m detection distance → Vehicle speed reduction

Relé 2: 0.5 m danger distance → Emergency stop

4–20mA real-time distance signal for obstacle distance display on vehicle HMI.

Vantagem

Flat housing resists scratches from cargo. Independent safety relay circuit enables emergency stop even if main controller fails.

Caso 6 | Máquinas de embalagem: Stacked Carton Height Monitoring

Working Conditions

Palletising station for carton stacking. Verify stack height compliance and implement overheight protection.

Relé 1: Stack height reaches target → Robot executes transfer operation

Relé 2: Overheight stack → Equipment lock and alarm

Continuous 4–20mA height data for production data acquisition.

Suitable for rigid flat-surface targets such as cartons and turnover boxes.

Resumo: Ideal Application Characteristics for This Model (Selection Checklist)

✅ Preferred Application Scenarios

  1. Confined installation space requiring flat rectangular housing; cylindrical ultrasonic sensors cannot be fitted
  2. Retrofit projects with existing control cabinets using passive contact signals; no intention to expand PLC I/O points
  3. Processes requiring dual limit switches + continuous analogue transmission integrated within one sensor
  4. Direct drive of 220 VAC audible/visual alarms or contactors (passive relay contacts)
  5. Environment with wide temperature fluctuation, poeira e umidade (compensação de temperatura integrada, IP65)

❌ Unsuitable Scenarios

  1. Applications with millions of frequent switching cycles (limited mechanical relay life; transistor-output sensors preferred)
  2. Targets made of thick / soft foam (ultrasound absorption leads to poor detection)
  3. Measurement distance below 100 milímetros (inherent blind zone)

 