Fênix 2981800 Relé de segurança - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Fênix 2981800 Relé de segurança - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

elétrica/

Fênix 2981800 Relé de segurança

  Model Segment Full Designation Description 2981800 Número do pedido. Phoenix Contact global unique part number PSR PSR Phoenix Contact PSR series safety relay (Programmable Safety Relay) SCP SCP Safety function: dedicated for Emergency Stop / Safety Gate monitoring (Safety Control for E-Stop/Door) 24DC 24DC Control voltage: DC24V input ESD ESD Function feature: Emergency Stop Delay ...

  • Detalhes do produto

 

Segmento de modeloFull DesignationDescrição
2981800Número do pedido.Contato Fênix global unique part number
PSRPSRPhoenix Contact PSR series safety relay (Programmable Safety Relay)
SCPSCPFunção de segurança: dedicated for Emergency Stop / Safety Gate monitoring (Safety Control for E-Stop/Door)
24CC24CCTensão de controle: DC24V input
ESDESDFunction feature: Emergency Stop Delay
4X14X1Configuração de contato: 4 contatos (2 safety NO + 2 auxiliary NO), 1-channel safety input
3030Delay range: adjustable power-off delay 0.1s ~ 30s

Aplicativo principal: Single-channel safety relay for Emergency Stop and Safety Gate monitoring. It complies with safety rating SIL 3 / Cat.4 PL e, with 0.1–30s adjustable power-off delay. Suitable for protection scenarios of automated equipment requiring safety stop delay.

  1. Especificações principais
Categoria de parâmetroEspecificação detalhadaObservações
Desempenho de segurançaNível de segurança: SIL 3 (CEI 61508)Meets highest industrial safety requirements
Performance Level: PL e, Categoria 4 (EN ISO 13849-1)
PFHd: 2.5×10⁻⁸/h
Características de entradaTensão de controle: CC24V (19.2~28.8V)Compatible with standard industrial 24V DC control systems
Corrente de entrada: Max 40mA
Input Channel: 1 safety input (NC/NO optional)
Modo de reinicialização: Automático / Manual selectable
Características de saídaSafety Contacts: 2 pcs N/O (Force-guided)Force-guided safety contacts ensure fail-safe operation
Contatos Auxiliares: 2 pcs N/O
Avaliação de contato: AC-15: 230V/2,5A
DC-13: 24V/2,5A
Max Switching Voltage: 250V CA/CC
Max Switching Current: 6UM
Delay CharacteristicsPower-off delay: continuously adjustable 0.1s~30sAdapt to different equipment stopping time requirements
Setting Accuracy: ±10%
Características FísicasDimensões: W22.5mm × H99mm × D121mmSingle-channel width, economiza espaço no armário
Peso: Aprox.. 0.22kg
Montagem: 35mm trilho DIN (EM 60715)
Fiação: Plug-in screw terminals
Environmental CharacteristicsTemperatura operacional: -20~+60℃Industrial-grade environmental adaptability for harsh working conditions
Temperatura de armazenamento: -40~+85℃
Umidade: 5~95%RH (sem condensação)
Resistência à vibração: 10~150Hz, 2g
Resistência ao choque: 15g
Safety CertificationsCE, UL, CSA, TÜV, ATEXEm conformidade com os padrões internacionais de segurança, globally applicable
  1. Lista de acessórios & Installation Guidelines

3.1 Standard Accessories

Safety relay unit ×1

Installation manual ×1

Terminal marking label ×1

Fixing clip ×2 (for DIN rail locking)

Delay adjustment screwdriver ×1 (special tool)

3.2 Precauções de instalação

  1. Mounting Requirement: Install on standard 35mm DIN rail; maintain ≥5mm clearance from adjacent modules for heat dissipation.
  2. Especificação de fiação:

Circuito de Controle: Connect DC24V to A1(+)、A2(-)

Safety Input: Connect E-stop / safety gate contact to S11S12 (NC contact preferred)

Saída de segurança: Connect safety circuit (por exemplo. bobina do contator) para 13-14、23-24

Auxiliary Output: Connect alarm / indication circuit to 31-32、41-42

  1. Reset Setting:

Auto Reset: Automatically restore after power cycle

Redefinição manual: Requires external reset signal or manual reset button operation

  1. Delay Adjustment: Use the dedicated screwdriver to adjust the front panel potentiometer to set 0.1–30s power-off delay.
  2. Cross-model & Cross-brand Replacement

4.1 Phoenix Contact Same Series Alternative Models

Model No.Diferença CentralCenário de aplicação
29818001 canal, 2 segurança + 2 contatos auxiliares, 0.1–30s delayStandard E-stop / safety gate monitoring (current model)
29818011 canal, 2 segurança + 2 contatos auxiliares, 0.1–10s delayEquipment with short stopping time
29818021 canal, 2 segurança + 2 contatos auxiliares, 0.1–1s delayFast stop equipment
29818102 canais, 4 segurança + 2 contatos auxiliares, no delayDual-channel redundant safety system
29818201 canal, 2 segurança + 2 contatos auxiliares, with alarm outputSystem requiring alarm indication

4.2 Cross-brand Equivalent Solutions

MarcaModeloParâmetros principaisCompatibility Note
SchneiderZelio SR2P121BD1 canal, 2 safety contacts, 24Em DC, Cat.4Similar function, different wiring layout
Siemens3SK1111-1AB301 canal, 2 safety contacts, 24Em DC, SIL 3Different dimensions, cabinet rearrangement required
OmronG9SA-321-T151 canal, 2 safety contacts, 24Em DC, Cat.4Delay range 0.05–10s, slightly narrower
ABBMSR12751 canal, 2 safety contacts, 24Em DC, SIL 3Preço mais alto, fully identical function
WeidmüllerDRM570730LT1 canal, 2 safety contacts, 24Em DC, Cat.4Fixed 1s non-adjustable delay

 

  1. Seleção & Diretrizes de Substituição

5.1 Critérios Básicos de Seleção

✅ Safety Level Matching: Ensure required safety rating (SIL/PL/Cat.) does not exceed product capability (SIL 3 / Cat.4 PL e).

✅ I/O Requirement:

Entrada: 1 channel sufficient; confirm NC or NO contact type.

Saída: Verify 2 segurança + 2 auxiliary contacts meet control demands.

Capacidade de contato: Ensure load current ≤2.5A (AC-15/DC-13).

✅ Delay Requirement: Confirm 0.1–30s adjustable range covers equipment stopping time.

✅ Reset Mode: Select auto or manual reset according to operation needs.

✅ Environmental Adaptation: Operating temperature ≤60℃ and humidity within industrial standard range.

5.2 Atualizar & Opções de substituição

Option A: Same Series Function Upgrade

More channels: 2981800 → 2981810 (2 canais, 4 safety contacts)

Add alarm output: 2981800 → 2981820 (with alarm output)

Shorter delay: 2981800 → 2981801 (0.1–10s) ou 2981802 (0.1–1s)

Option B: Migrate from PSRclassic to PSRmini (Space Optimization)

Modelo de substituição: 2981900 (PSRmini-SCP-24DC/ESD/4X1/30)

Vantagem: Only 17.5mm width (5mm narrower), identical functions, economiza espaço no armário.

Option C: Migrate from PSRclassic to PSRmodular (System Expansion)

Solução: PSRmodular system + safety function modules

Vantagem: Multi-channel expandable; integrates safety gate, E-stop, light curtain and other safety functions, suitable for complex safety systems.

5.3 Solução de problemas comuns

Fenômeno de falhaPossível causaSolução
Module indicator offControl power disconnected or faultyCheck DC24V input, measure voltage within 19.2~28.8V
No safety output actionSafety input loop openCheck E-stop / safety gate contact wiring and loop continuity
Abnormal delay timeImproper potentiometer adjustmentReadjust with dedicated screwdriver; calibrate with timer recommended
Falha na redefiniçãoIncorrect reset mode settingVerify auto/manual reset configuration and check reset signal
Contact adhesionOverload current exceededMeasure load current; add intermediate relay if necessary

Contato Fênix 2981800 (PSR-SCP-24DC/ESD/4X1/30) is a single-channel safety relay with adjustable power-off delay, specially designed for emergency stop and safety gate monitoring, reaching the highest safety level SIL 3 / Cat.4 PL e. Its 22.5mm slim design and plug-in wiring facilitate installation and maintenance, while the 0.1–30s adjustable delay adapts to various equipment shutdown requirements. Durante a seleção, focus on safety rating, I/O configuration, delay range and reset mode. For upgrade, choose extended models in the same series or migrate to PSRmini / PSRmodular for space saving or system expansion.

Complete Model List of Phoenix Contact Safety Relays (Structured Classification)

  1. Model Naming Rule Overview
PrefixoCódigo da sérieMiddle CodeSignificadoSufixoSignificado
PSRBasic identifier for Phoenix safety relaySCPE-stop / Safety Gate dedicated24CCControl voltage DC24V
PSRRelé de segurançaSPPStandard Safety ProtectionESDEmergency Stop Delay (0.1-30é)
PSRRelé de segurançaMCMini Compact4X1Contato: 4 NÃO (2 segurança + 2 auxiliary)
PSRRelé de segurançaMSMonitoring Safety30Delay time range (0.1-30é)
PSRRelé de segurançaUNIUniversal ConfigurablePIPush-in spring terminal
PSRRelé de segurançaMilímetrosMotion MonitoringSCTerminal de parafuso
  1. PSRclassic Series (Standard Safety Relays)

2.1 E-Stop / Safety Gate (SCP Series)

ModeloNúmero do pedido.Parâmetro principalNível de segurançaAplicativo
PSR-SCP-24DC/ESD/4X1/3029818001Ch, 2Safety+2Aux, 0.1-30s delaySIL 3/Cat.4 PL eStandard E-stop / Safety Gate
PSR-SCP-24DC/ESD/4X1/1029818011Ch, 2Safety+2Aux, 0.1-10s delaySIL 3/Cat.4 PL eShort stop time equipment
PSR-SCP-24DC/ESD/4X1/129818021Ch, 2Safety+2Aux, 0.1-1s delaySIL 3/Cat.4 PL eFast stop equipment
PSR-SCP-24DC/ESD/5X1/1X2/30029814281/2Ch, 3Safety+1NC+2Aux, 0.1-300s delaySIL 3/Cat.4 PL eLong delay shutdown system
PSR-SCP-24UC/ESA4/3X1/1X2/B29637632Ch, 3Safety+1Aux, no delaySIL 3/Cat.4 PL eDual-channel redundant safety system
PSR-SCP-24DC/MXF3/4X1/2X2/B2903257Multi-Ch, 4Safety+2Aux, 3 safety functionsSIL 3/Cat.4 PL eMulti-function safety monitoring

2.2 Standard Safety Function (SPP Series)

ModeloNúmero do pedido.Parâmetro principalNível de segurançaAplicativo
PSR-SPP-24DC/SDC4/2X1/B29014261Ch, 2Safety contacts, no delaySIL 3/Cat.4 PL eBasic safety loop
PSR-SPP-230AC/ESAM2/3X1/1X2/B29014311Ch, 3Safety+1Aux, AC230VSIL 3/Cat.4 PL eAC power supply system
PSR-SPP-24UC/URM/3X1/3X229014271Ch, 3Safety+3Aux, universal voltageSIL 3/Cat.4 PL eMulti-voltage compatible system
PSR-SPP-24DC/ESD/3X1/1X2/3029814271Ch, 3Safety+1Aux, 0.1-30s delaySIL 3/Cat.4 PL eDelay-type safety system

2.3 Light Curtain Monitoring (SCR Series)

ModeloNúmero do pedido.Parâmetro principalNível de segurançaAplicativo
PSR-SCR-24DC/3X1/1X229815002Ch, 3Safety+1Aux, dedicated for light curtainSIL 3/Cat.4 PL eStandard light curtain monitoring
PSR-SCR-24DC/4X1/2X229815012Ch, 4Safety+2Aux, dedicated for light curtainSIL 3/Cat.4 PL eComplex light curtain safety system
PSR-SCR-24DC/5X1/1X229815022Ch, 5Safety+1Aux, dedicated for light curtainSIL 3/Cat.4 PL eHigh-density safety output

2.4 Two-Hand Control (SCT Series)

ModeloNúmero do pedido.Parâmetro principalNível de segurançaAplicativo
PSR-SCT-24DC/2X1/1X229816002Ch, 2Safety+1Aux, two-hand controlSIL 3/Cat.4 PL eStandard two-hand operation
PSR-SCT-24DC/3X1/2X229816012Ch, 3Safety+2Aux, two-hand controlSIL 3/Cat.4 PL eComplex two-hand operation
  1. PSRmini Series (Micro Compact, 17.5mm Width)

3.1 Basic Safety Function (MC Series)

ModeloNúmero do pedido.Parâmetro principalNível de segurançaAplicativo
PSR-MC32-3NO-1NC-24-230UC-SP27005251/2Ch, 3Safety+1NC, universal voltageSIL 3/Cat.4 PL eGeneral safety monitoring
PSR-MC34-3NO-1DO-24DC-SP27005481/2Ch, 3Safety+1diagnostic output, CC24VSIL 3/Cat.4 PL eSystem with diagnostic output
PSR-MC45-3NO-1DO-24DC-SC10820241Ch, 3Safety+1diagnostic output, CC24VSIL 3/Cat.4 PL eCompact E-stop system
PSR-MC22-2NO-1NC-24DC-SP27005001Ch, 2Safety+1NC, CC24VSIL 3/Cat.4 PL eSmall safety loop

3.2 Safety Monitoring Module (MS Series)

ModeloNúmero do pedido.Parâmetro principalNível de segurançaAplicativo
PSR-MS21-1NO-1DO-24DC-SC27021921Ch, 1Safety+1digital output, CC24VSIL 3/Cat.4 PL eSafety controller expansion
PSR-MS31-2NO-1DO-24DC-SP27022001Ch, 2Safety+1digital output, CC24VSIL 3/Cat.4 PL eSafety status monitoring
  1. PSRmodular Series (Modular Safety System)

4.1 Main Control Module

ModeloNúmero do pedido.Parâmetro principalNível de segurançaAplicativo
PSR-UNI-L-1X4NO-1DO-24DC-PI14876481/2Ch, 4Safety+1DO, configurávelSIL 3/Cat.4 PL eUniversal configurable safety system
PSR-UNI-L-2X4NO-2DO-24DC-PI14876492Ch, 8Safety+2DO, configurávelSIL 3/Cat.4 PL eComplex safety system
PSR-UNI-L-1X2NO-1NC-1DO-24DC-PI14876501/2Ch, 2Safety+1NC+1DOSIL 3/Cat.4 PL eSystem with NC output

4.2 Módulo de Expansão

ModeloNúmero do pedido.Parâmetro principalNível de segurançaAplicativo
PSR-EXT-L-1X4NO-24DC-PI14876514-safety output expansionSIL 3/Cat.4 PL eOutput expansion
PSR-EXT-L-1X2NO-1NC-24DC-PI14876522Safety+1NC output expansionSIL 3/Cat.4 PL eMixed output expansion
  1. PSRmotion Series (Motion Monitoring Safety Relay)

5.1 Zero Speed / OverSpeed Monitoring

ModeloNúmero do pedido.Parâmetro principalNível de segurançaAplicativo
PSR-MM25-1NO-2DO-24DC-SC2702355Sensorless zero-speed monitoring, 3-motor de faseSIL 3/Cat.3 PL eMotor zero-speed safety protection
PSR-MM35-1NO-2DO-24DC-SC2702356Overspeed monitoring, 3-motor de faseSIL 3/Cat.3 PL eMotor overspeed safety protection
PSR-MM45-1NO-2DO-24DC-SC2702357Zero-speed + overspeed dual monitoring, 3-motor de faseSIL 3/Cat.3 PL eFull motor speed monitoring

5.2 Rotation Direction Monitoring

ModeloNúmero do pedido.Parâmetro principalNível de segurançaAplicativo
PSR-MD25-1NO-2DO-24DC-SC2702360Rotation direction monitoring, 3-motor de faseSIL 3/Cat.3 PL eMotor rotation direction safety control
  1. Safety Coupling Relays (PSR-SCP/SPP Series)
ModeloNúmero do pedido.Parâmetro principalNível de segurançaAplicativo
PSR-SCP-24DC/FSP/1X1/1X229817001Safety+1Aux contact, coupling functionSIL 3Safety signal isolation
PSR-SCP-24DC/FSP2/2X1/1X229817012Safety+1Aux contact, coupling functionSIL 3Dual-channel safety isolation
PSR-PS21-1NO-1NC-24DC-SC29817021Safety+1NC contact, coupling functionSIL 3Safety signal switching
  1. Key Selection Parameter Comparison
Categoria de parâmetroKey IndexDicas de seleção
Nível de segurançaSIL 1-3, Cat.1-4, PL a-eDetermined by equipment risk assessment; max support SIL 3/Cat.4 PL e
Input Channel1 Canal / 2 CanalSingle channel for basic safety; dual channel for redundant safety
Configuração de contatoQuantity of safety / contatos auxiliares≥2 safety contacts recommended; auxiliary contacts for alarm & indication
Tensão de controleCC24V / AC230V / UniversalMatch on-site control system power supply
Function FeatureAtraso / Diagnostic / Cross-circuit detectionE-stop requires delay; complex system needs diagnostic function
Mounting Width17.5milímetros / 22.5milímetros / 27.5milímetrosChoose PSRmini (17.5milímetros) for limited cabinet space
Wiring TypeParafuso / Push-in springPush-in for frequent wiring; screw type for vibration environment
  1. Notas Suplementares

8.1 Series Positioning

PSRclassic: Standard type with complete functions, width starting from 22.5mm, suitable for conventional safety applications.

PSRmini: Micro compact type, only 17.5mm width, economiza espaço no armário.

PSRmodular: Configurable modular system, suitable for complex safety systems with expandable functions.

PSRmotion: Dedicated for motion monitoring, applicable to motor zero-speed / overspeed / rotation direction safety control.

8.2 Informações de substituição

Old models are gradually phased out; priority recommended to select models manufactured after 2020.

Some models are discontinued; refer to Phoenix Contact official website or technical support for replacement.

8.3 Certificação de Segurança

Full series certified by CE, UL, CSA, TÜV, compatível com IEC 61508 and EN ISO 13849-1.

Partial models with ATEX certification for explosive atmosphere applications.

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado