Pilz 773400-PNOZ-MI1P Safety Input Expansion Module - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Pilz 773400-PNOZ-MI1P Safety Input Expansion Module - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

elétrica/

Pilz 773400-PNOZ-MI1P Safety Input Expansion Module

Pilz 773400-PNOZ-MI1P Safety Input Expansion Module The Pilz 773400-PNOZ-MI1P is an 8-channel 24VDC safety digital input expansion module belonging to the PNOZmulti Classic product range. It provides I/O expansion for the PNOZmulti safety control system and supports safety functions such as emergency stop, safety gate monitoring and two-hand control. Complying with PLd per EN ISO ...

  • Detalhes do produto

Pilz 773400-PNOZ-MI1P Safety Input Módulo de Expansão

O Cogumelo 773400-PNOZ-MI1P is an 8-channel 24VDC safety digital input expansion module belonging to the PNOZmulti Classic product range. It provides I/O expansion for the PNOZmulti safety control system and supports safety functions such as emergency stop, safety gate monitoring and two-hand control. Complying with PLd per EN ISO 13849-1 and SIL CL 2 per EN/IEC 62061, it is designed for industrial automation applications requiring high-safety-level signal acquisition. This product has been discontinued, and corresponding modules from the PNOZmulti 2 series are recommended as replacements.

  1. Definição de código de modelo
Segmento de códigoDefiniçãoDescrição detalhada
773400Código do pedidoUnique official Pilz part number for ordering and inventory management
PNOZPrefixo da sérieCore identifier for Pilz safety relay and safety control product line
MITipo de móduloSafety Digital Input Module (M-Series Input), differentiated from MO (Saída) and MC (Mixed I/O)
1Channel SpecStandard 8-input variant (1 = 8 canais, 2 = 16 canais)
PVersion CodePNOZmulti Classic edition, distinguished from Series 2 (new-generation PNOZmulti 2)

Observação: This is an expansion module for PNOZmulti Classic and must be used together with compatible base units (por exemplo. PNOZ m1p); standalone operation is not supported.

  1. Especificações Técnicas Principais
CategoriaEspecificaçãoObservações
Características Básicas
Channel Count8 safety digital input channelsConfigurable for single-channel or dual-channel safety circuit logic
Tipo de entrada24VDC discrete inputEm conformidade com EN 61131-2 Tipo 1; compatible with PNP / NPN sensors
Input PolarityPositive/Negative Logic configurableParameterized via PNOZmulti Configurator software
Corrente de entradaAprox.. 5mA por canalLow-power design to reduce load on field sensors
Parâmetros Elétricos
Tensão operacional20.4~28.8VDC (nominal 24VDC)Powered from base unit via internal backplane bus
Input Signal LevelOFF-state: -3~+5VDC; ON-state:19.2~30VCCWide voltage tolerance against field supply fluctuation
Test Pulse FunctionBuilt-in test pulse outputDetects short-circuit across input contacts to elevate safety integrity
Isolation RatingNo inter-channel isolation; isolation between module and backplaneDielectric withstand: 250Vrms
Tempo de resposta≤10ms (factory default setup)Fast safety reaction for emergency stop and safety interlock
Certificações de segurança
Classificação de segurançaEM ISO 13849-1 PLd; EN/IEC 62061 SIL CL 2For medium-risk machinery safety applications
Approved CertificatesCE, UKCA, cULus, KOSHA, EAC (TÜV certified)Meets global mainstream market safety compliance
Dados Ambientais
Temperatura operacional.0℃ ~ 60 ℃Standard industrial ambient range
Temperatura de armazenamento.-25℃ ~ 70 ℃Tolerates harsh transportation & storage conditions
Umidade relativa93%RH @40℃, sem condensaçãoExtended humidity resistance
Proteção de entradaIP20For cabinet indoor installation only
Mecânico & Montagem
Dimensões94(H)×22.5(C)×121(D) milímetrosStandard DIN rail footprint
Peso~120g (without terminals), ~138g (com terminais)Lightweight to minimize DIN rail load
MontagemHorizontal installation on 35×7.5mm EN 50022 standard DIN railConvenient system expansion and integration
Tipo de terminalOptional spring-cage plug-in terminals / terminais de parafusoFast field wiring and maintenance

III. Full Product Lineup (PNOZmulti Classic Input Expansion Modules)

ModeloChannel QtyInput SpecRecurso EspecialNúmero do pedido.Lifecycle Status
PNOZ MI1P824VDC Safety DIStandard non-coated version773400Descontinuado
PNOZ MI1P C824VDC Safety DIConformal coated for harsh ambient773405Descontinuado
PNOZ MI2P1624VDC Safety DI16-channel extended model773410Descontinuado
PNOZ MI2P C1624VDC Safety DI16-channel coated variant773415Descontinuado
PNOZ MI4P424VDC Safety DICompact 4-channel type773420Descontinuado
  1. Substituição & Comparação entre marcas
  2. Internal Pilz Alternatives
Original PNReplacement PNMotivo da substituiçãoCompatibility Note
773400-PNOZ-MI1P774700-PNOZ m2p mi1pNew upgrade to PNOZmulti 2 plataformaRequires PNOZmulti 2 base unit + full program reconfiguration
773400-PNOZ-MI1P774705-PNOZ m2p mi1p CCoated version for corrosive environmentRequires PNOZmulti 2 base unit + full program reconfiguration
773400-PNOZ-MI1P773405-PNOZ MI1P CConformal coating addedDrop-in compatible with original PNOZmulti Classic base unit
  1. Competitor Cross Reference
Pilz PartEquivalente SiemensEquivalente de SchneiderEquivalente OmronDiferenças Fundamentais
773400-PNOZ-MI1P3RK1304-0CB00-0AA2140SAI73400G9SA-501Cogumelo: Built-in safety test pulse, PLd/SIL2
Siemens: PROFIsafe fieldbus, PLd/SIL3
Schneider: Quantum safety I/O, PLd/SIL2
Omron: Standalone safety relay, PLc/SIL1
  1. Campos de aplicação & Casos da Indústria
  2. Cenários de aplicação recomendados

Fabricação Automotiva

Body Welding Line: Signal collection for E-stop pushbuttons, safety gate limit switches and two-hand control devices

Final Assembly Line: Connection for safety light curtains, safety mats and robot perimeter protection signals

Coating Workshop: Interlock input for explosion-proof doors and flammable gas detection alarms

Máquina-ferramenta & Usinagem

CNC Machine: Safe spindle stop, tool-change safety interlock and workpiece clamping confirmation signals

Imprensa & Bending Equipment: Mould safety gate, two-hand start button and slide stroke limit monitoring

Automated Conveying Line: Conveyor safety interlock and personnel access detection

Comida & Bebida / Embalagem

High-speed Packaging Machine: Safety door switches, emergency stop and overload protection signals

Food Processing Line: Wash zone interlock and sterilizer safety gate status monitoring

Filling Equipment: Bottle/can in-position detection and protective door interlock

Logística & Warehouse Automation

Automated AS/RS: Stacker crane limit switches, E-stop and walk-in access detection

Conveyor System: Line emergency stop, safety gate and overload fault input

Robotic Sorting Line: Robot cell guarding and safety light curtain signal acquisition

  1. Aplicativos não recomendados

Standalone operation: Mandatory pairing with PNOZmulti Classic base unit; cannot run independently

High safety requirement (PL e / SIL3): Select PNOZmulti 2 or higher-grade safety modules instead

Outdoor exposed installation: IP20 rated only for cabinet mounting

AC signal input: Module exclusively for 24VDC; dedicated AC input modules required for AC field signals

  1. Caso de aplicação típico

Project Title: Safety Retrofit for Automotive Component Stamping Line

Bill of Material: 1×PNOZ m1p base unit + 2×PNOZ MI1P (773400) + 1×PNOZ MO1P output module + PNOZmulti Configurator

Benefícios do aplicativo:

  1. Monitors 8 safety gate limits, 4 emergency stops and 2 two-hand control signals
  2. Redundant safety circuit design fulfilling EN ISO 13849-1 PLd specification
  3. Onboard test pulse automatically diagnoses input contact short-circuit to improve system reliability
  4. Integrated diagnostics cut unplanned downtime by 40% and enable rapid fault pinpointing for safety loops
  5. Guia de solução de problemas
Sintoma de falhaCausa raizEtapas de inspeçãoAção Corretiva
Module dead, all LEDs off1.Base unit power failure1.Check base unit power LED1.Repair base unit power supply
2.Poor backplane connection2.Unplug and re-seat module2.Fix module locking position
3.Internal hardware damage3.Replace with spare module3.Install replacement module
Partial channels no input1.Erro de fiação1.Verify wiring against schematic1.Correct field wiring
2.Field sensor defective2.Measure sensor output via multimeter2.Replace faulty sensor
3.Incorrect test pulse setup3.Check test pulse parameter in Configurator3.Config test pulse (only for dry contacts)
4.Burned input channel4.Test with known-good sensor4.Swap to spare channel or replace module
Spurious safety trip1.Interferência EMI1.Check shielding & aterramento1.Reroute cable & add shielding
2.Unstable supply voltage2.Measure input DC 19.2~30V range2.Add power filter for stable supply
3.Loose terminal wiring3.Tighten all screw terminals3.Re-terminate loose wiring
4.Test pulse cross-interference4.Adjust/disable test pulse (for active sensors only)4.Optimize test pulse configuration
Permanent fault LED ON1.Safety circuit fault1.Inspect safety loop wiring1.Remediate faulty safety wiring
2.Backplane communication loss2.Check inter-module bus connection2.Restore bus connection
3.Invalid project configuration3.Download corrected configuration3.Re-program and download project

VII. Diretrizes de seleção & Referência rápida

Mnemônico de seleção

Eight-channel safety DI MI1P, 24VDC PNOZ expansion piece;

PLd safety grade, test pulse stops short-circuit disease;

Auto, machine, packaging cabinet-mounted IP20 lease;

Classic discontinued, upgrade to m2p series.

Regras rápidas

  1. Model Decoding:773400 = PNOZ MI1P; PNOZ=Safety Series; MI=Input; 1=8CH; P=Classic Version
  2. Core Spec Shortcut:8CH /24VDC /PLd SIL2 /Built-in Test Pulse /IP20 /DIN Rail Mount
  3. Guia de substituição:Upgrade → PNOZmulti2; Harsh environment → Coated C version; Same platform → Classic coated spare
  4. Application Filter:Safety DI + Medium risk + Cabinet installation = PNOZ MI1P applicable

VIII. Informações sobre pedidos & Acessórios

Standard Part No.:773400-PNOZ-MI1P (8-channel safety input module)

Conformal Coated Variant:773405-PNOZ-MI1P C

Recommended Spare Parts:

783400: PNOZmulti Spring Terminal Kit (fits MI1P/MI2P/MO1P)

793400: PNOZmulti Screw Terminal Kit (fits MI1P/MI2P/MO1P)

779110: PNOZmulti Bus Terminator (mandatory for multi-module expansion setup)