Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

SCHNEIDER iC65N-2P-C25A Miniature Circuit Breaker - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

disjuntor/

SCHNEIDER iC65N-2P-C25A Miniature Circuit Breaker

Technical Specifications & Application Guide This is a 2‑pole, Tipo C, 25A miniature circuit breaker (MCB) from Schneider Electric’s Acti9 series, with order code A9F18225 and rated breaking capacity 6kA. It provides overload and short‑circuit protection for lighting, socket, and small motor circuits in AC distribution systems. Features include 3‑stage current limiting, quick make mechanism, ...

  • Detalhes do produto

Technical Specifications & Application Guide

This is a 2‑pole, Tipo C, 25UM disjuntor miniatura (MCB) from Schneider Electric’s Acti9 series, with order code A9F18225 and rated breaking capacity 6kA.

It provides overload and short‑circuit protection for lighting, socket, and small motor circuits in AC distribution systems.

Features include 3‑stage current limiting, quick make mechanism, and protection degree IP40 (front) / IP20 (terminais).

It is compatible with iC65 series accessories for functional expansion.

  1. Análise do modelo
CodeSignificadoDescrição
SCHNEIDERMarcaSchneider Electric (França), global electrical equipment manufacturer
iC65NSérieActi9 iC65 MCB, N‑type breaking capacity (6o)
2PNumber of poles2‑pole, breaks phase and neutral simultaneously, for 230V/400V systems
CTripping curveTipo C, instantaneous tripping at 5~10×In (5In~10In)
25UMCorrente nominal25 amperes continuous at 30°C ambient
A9F18225Full order codeOfficial unique identifier
  1. Core Specifications
ItemEspecificaçãoNotas
Básico
TipoDisjuntor Miniatura (MCB)Complies with IEC 60898-1 / GB 10963.1
Tripping typeThermal‑magneticSobrecarga (thermal) + short‑circuit (magnetic) proteção
Capacidade de ruptura6oMax breaking current at rated voltage
Rated operational voltageAC 230V/400VFor 2‑pole version
Rated insulation voltage500VMax withstand voltage of insulation
Rated impulse withstand voltage6kVSurge voltage immunity
Rated frequency50/60HzGlobal grid compatible
Tripping characteristics
Proteção contra sobrecarga1.13Em (no trip in 1h), 1.45Em (trip within 1h)Meets IEC requirements
Short‑circuit protectionInstantaneous at 5In~10InTipo C, suitable for lighting, resistive loads, small motors
Physical & environmental
Dimensões (W×H×D)18mm×86mm×62mmStandard modular, 2P = 2 modules (18mm/pole)
Protection degreeIP40 (front), IP20 (terminais)Solid object and moisture protection
Temperatura operacional-35°C ~ +70°CSuitable for harsh industrial environments
Mounting35mm trilho DINStandard panel mounting
CertificationsCCC, CE, RoHSMeets Chinese and international safety & environmental standards
  1. Características
  2. Protection performance

3‑stage current limiting: Quickly limits peak current during short circuit, reduces thermal stress, protects equipment and cables.

Selective protection: Coordinates with upstream breakers for selective tripping, limits fault area.

Fault indication: Red window shows tripped status for quick diagnosis.

  1. Structural advantages

Dual‑lock clip: Secures firmly on DIN rail, prevents vibration loosening.

Quick make mechanism: Improves closing speed, reduces arcing, extends life.

Projeto modular: Accepts auxiliary contacts, contatos de alarme, shunt trip, disparo por subtensão, etc..

  1. Safety design

Isolation function: Safe isolation distance in OFF position, meets electrical safety rules.

Anti‑misoperation: Handle design prevents accidental closing.

Flame‑retardant housing: V0 grade material improves cabinet safety.

  1. Instalação & Maintenance

Installation Rules

  1. Mount vertically (±15°) for proper tripping.
  2. Wiring: Copper 1.5~35mm², Aluminium 2.5~35mm², torque 1.2~4N·m (depends on cross‑section).
  3. Environment: Avoid damp, empoeirado, corrosive or high‑vibration locations.
  4. Spacing: Maintain clearance for heat dissipation; follow installation manual.

Maintenance Guide

ItemIntervalCriterionSolução
Visual inspectionMonthlyNo damage, no overheating, tight connectionsClean, tighten loose terminals
Function testQuarterlyManual ON/OFF smooth, no stickingOperate 3–5 times, check mechanism
Trip testAnnuallySobrecarga & short‑circuit protection functionalTest with dedicated equipment or simulate overload
Accessory checkAnnuallyAuxiliary & alarm contacts workingCheck contact condition, replace damaged parts

Solução de problemas

  1. Tropeços frequentes: Check overload → short circuit → high ambient temperature → aging.
  2. Cannot close: Check short circuit → handle position → trip reset → loose wiring.
  3. Overheating: Check terminal torque → overload → ventilation.
  4. Atualizar & Replacement

5.1 Same‑series Upgrades

iC65H-2P-C25A (A9F28225): H‑type, 10o, for higher short‑circuit current.

iC65L-2P-C25A (A9F38225): L‑type, 15o, for heavy industrial use.

iC65N-2P-C25A‑Vigi (A9V58225): With residual current protection (RCCB), prevents electric shock.

5.2 Functional Accessories

AccessoryTypical ModelFunção
Auxiliary contactA9A269241NO+1NC, remote status indication
Shunt tripA9X16224Remote tripping, por exemplo, fire alarm
Undervoltage tripA9X16624Auto‑trip on low voltage
Alarm contactA9A27924Signal when breaker trips

5.3 Cross‑series Alternatives

SérieReplacementCompatibilidade
Easy9EA9AN 2P C25AMesmas dimensões, 6o, economical
Acti9 CVSCVS100B 2P C25AMCCB, higher breaking capacity (10o), main circuit use
Merlin GerinC65N 2P C25AFully compatible with iC65
  1. Applications
  2. Edifícios comerciais: Offices, lojas, hotels – lighting & socket circuits.
  3. Industrial automation: Control panels, small motors (≤5.5kW), VFD input protection.
  4. Residential: Home distribution – air conditioners, kitchen appliances.
  5. Public facilities: Schools, hospitais, stadiums – electrical safety.
  6. Selection & Purchasing Tips
  7. Correspondência de carga: Type C for lighting, tomadas, small motors (≤5.5kW). Use Type B for pure resistive, Type D for large motors.
  8. Capacidade de ruptura: Choose N (6o), H (10o), eu (15o) based on system short‑circuit current.
  9. Poloneses: 2P for 230V single‑phase where phase + neutral must be disconnected.
  10. Acessórios: Add aux, shunt, undervoltage for smart systems.
  11. Authenticity: Buy from authorized Schneider distributors.
  12. Quick Fault Guide
SymptomPossible CauseSolução
Trips immediately after closingShort circuit / sobrecargaLocate short, reduce load or upsize breaker
Trips after running a whileSobrecarga / alta temperaturaReduce load, improve ventilation, check cable size
Handle cannot be pushed to ONNot reset / wiring faultPull to OFF first, then ON; check circuit
Terminal overheatingLoose connectionRetorque after power off, check terminals
No operationThermal‑magnetic unit failedReplace MCB, check coordination

SCHNEIDER iC65N-2P-C25A

Cross‑Brand Replacement Guide

Core Summary: The iC65N-2P-C25A (A9F18225) can be directly replaced by equivalent MCBs from major international and domestic brands.

Key matching requirements:

2P, Tipo C, 25UM, 6o, 35mm DIN rail mounting.

  1. International Brand Direct Replacements

ABB

ReplacementOrder CodeBreakingCompatibilidade
S202-C252CDS252001R02546oBest match, same dimensions, direct swap
S202M-C252CDS262001R025410oHigher breaking capacity
S202L-C252CDS242701R02544.5oEconomy option

Siemens

ReplacementSérieBreakingCompatibilidade
5SL6225-75SL6oDirect replacement, CEI 60898-1
5SY6225-75SY6oEconomy range
5SN6225-7CN5SN6oClassic, reliable

Eaton

ReplacementSérieBreakingCompatibilidade
FAZ6-C25/2FAZ6oMesmas dimensões & mounting
PL9-C25/2PL96oHigh performance, fast limiting

Moeller

ReplacementSérieBreakingCompatibilidade
FAZ6-C25/2FAZ6oMesmas dimensões & mounting
PL9-C25/2PL96oHigh performance, fast limiting
  1. Chinese Domestic Brands
MarcaReplacementBreakingCompatibilidade
CHINTNXB-63-2P C256oCost‑effective, direct fit
DELIXICDM3-63C25/2P6oMesmas dimensões
LiangxinNDM1-63C25/2P6oHigh quality domestic
TENGENTGM1-63C25/2P6oProteção básica, economical
  1. Critical Parameter Matching
ItemOriginal (iC65N-2P-C25A)Must MatchAjustávelNotas
Poloneses2P2PDisconnect phase + neutral
CurveTipo C (5~ 10 pol.)Tipo CFor lighting & small motors
Atual25UM25UMContinuous rating
Breaking6o≥6kACan be higher (10o)Ensure safe short‑circuit interruption
Mounting35mm trilho DIN35mm trilho DINStandard panel mount
Largura18milímetros18milímetrosH/D may varyFits standard spacing
TensãoAC 230V/400VAC 230V/400VUniversal AC system
  1. Notas de substituição & Best Practice

Before Replacement

System short‑circuit current ≤ breaking capacity of replacement.

35mm trilho DIN, space, terminal size compatible.

Protection coordination with upstream/downstream devices.

Accessory mounting interface compatible.

Replacement has valid certifications (CCC, CE).

Procedure

  1. Power off and verify voltage absence.
  2. Remove wiring and old breaker.
  3. Clip replacement onto DIN rail.
  4. Torque terminals correctly.
  5. Test ON/OFF and tripping.
  6. Update labeling and drawings.

When NOT to replace

Original uses dedicated Schneider accessories (por exemplo, Vigi modules).

System short‑circuit current exceeds replacement rating.

Load inrush >10Em (unsuitable for Type C).

Extreme environment outside replacement specs.

  1. Recommended Replacement Levels
LevelRecommended ModelsApplicationAdvantage
1stABB S202-C25Industry, commerceFull performance, global support
Siemens 5SL6225-7
2ndEaton FAZ6-C25/2Control panelsGood value, easy install
Moeller DIL M9-25 C/2
3rdCHINT NXB-63-2P C25Residential, economyLow cost, fast local supply
DELIXI CDM3-63C25/2P
  1. Common Issues & Soluções
IssueCausaSolução
Frequent tripping after replacementWrong curve / sobrecargaConfirm Type C, check load, upsize if needed
Will not fitWrong rail / larguraUse 35mm DIN rail, 18mm width model
Wiring difficultIncompatible terminalsUse suitable lugs or select compatible model
Insufficient breaking capacityReplacement < system short鈥慶ircuit currentUse higher version (por exemplo, ABB S202M-C25, 10o)

Cross‑brand replacement for SCHNEIDER iC65N-2P-C25A depends on parameter matching + mechanical compatibility + protection coordination.

Top international brands (ABB, Siemens) give identical performance.

Marcas nacionais (CHINT, DELIXI) offer cost savings.

Always verify specifications and follow electrical safety standards.