Schneider IPRU40‑40KA Surge Protective Device

  IPRU40‑40KA is a Type 2 pluggable AC surge protective device (SPD) from Schneider Electric’s Acti9 series. Key specifications: maximum discharge current 40 kA, nominal discharge current 20 kA, maximum continuous operating voltage 350 V AC. It uses metal oxide varistor (MOVIMENTOS) technology and is suitable for lightning and surge protection in power distribution networks with TT/TN‑S earthing systems. Modelo ...

  • Detalhes do produto

 

IPRU40‑40KA is a Type 2 pluggable AC surge protective device (SPD) from Schneider Electric’s Acti9 series.

Key specifications: maximum discharge current 40 kA, nominal discharge current 20 kA, maximum continuous operating voltage 350 V AC.

It uses metal oxide varistor (MOVIMENTOS) technology and is suitable for lightning and surge protection in power distribution networks with TT/TN‑S earthing systems.

  1. Explicação do modelo
CódigoSignificadoDescrição
IPRUSériePluggable SPD of Schneider Acti9 series, supports hot‑swap module replacement for easy maintenance
40Maximum discharge current (Imax)40 kA (8/20 μs waveform)
40ONominal discharge current (Em)20 kA (8/20 μs waveform) (Observação: 40KA in model corresponds to In = 20 kA)
350VMaximum continuous operating voltage (Uc)350 V AC, suitable for 400 V three‑phase and 230 V single‑phase systems
PNúmero de pólos1P+N / 2P / 3P+N / 4P
  1. Principais especificações técnicas
ItemValorObservação
Classe de proteçãoType 2Complies with IEC 61643‑11:2011 & EN 61643‑11:2012
Discharge currentIn = 20 kA, Imax = 40 kA (8/20 μs)Common mode (CM) & differential mode (DM)
Voltage protection level (Acima)≤ 1.8 kV (DM), ≤ 1.4 kV (CM)Low residual voltage
Tempo de resposta≤ 25 nsNanosecond‑level response
Tensão operacionalUe = 230/400 V AC, 50/60 HzStandard low‑voltage distribution
Max continuous voltage (Uc)350 V AC (DM), 260 V AC (CM)Stable under grid fluctuations
Proteção de entradaIP40 front, IP20 terminalsIndustrial environment suitable
Temperatura operacional‑25 °C to +60 °CWide temperature range
Montagem35 mm standard DIN railCompatible with Acti9 circuit breakers
FiaçãoMax 35 mm², recommended 16 mm² solid / 25 mm² flexibleGood conductivity & heat dissipation
DimensõesWidth varies with poles (2P:45 mm, 3P+N:72 mm, 4P:90 mm), H85 mm, D65 mmDesign compacto
PesoAprox.. 200–450 g (depends on poles)Lightweight
Earthing systemTT / TN‑SNot suitable for TN‑C
  1. Principais vantagens & Aplicativos
  2. Vantagens

Pluggable design: Hot‑swap module without power interruption

Fácil manutenção: Local status indicator (green = normal, red = fault)

Alta confiabilidade: MOV technology, longa vida útil, strong anti‑aging

Safe design: Built‑in thermal disconnector to prevent fire risk

Strong compatibility: Fully compatible with Schneider Acti9 series

  1. Aplicações Típicas
CampoAplicativoProtected Equipment
Automação industrialWorkshop power, PLC cabinets, VFDsAutomation equipment, sensores
Edifícios comerciaisEscritórios, shoppings, hotéisLifts, AVAC, security, networks
InfrastructureCentros de dados, telecom, transportServers, comunicação, monitoramento
New energyPV inverters, wind convertersPower electronic devices
residencialQuadros de distribuição, casas inteligentesHousehold appliances
  1. Modelos Comuns & Pole Configurations
Modelo CompletoPolonesesNúmero do pedido.Aplicativo
IPRU40‑40KA 1P+N 350V1P+NA9L040200Single‑phase 2‑wire
IPRU40‑40KA 2P 350V2PA9L040300Single‑phase 3‑wire
IPRU40‑40KA 3P+N 350V3P+NA9L040600Three‑phase 4‑wire
IPRU40‑40KA 4P 350V4PA9L040400Three‑phase 4‑wire (full‑pole)
  1. Seleção & Notas de uso
  2. Coordenação: Used as Type 2 protection, cooperate with Type 1 (por exemplo. IPR 120KA)
  3. Seleção de pólo: 3P+N/4P for three‑phase; 2P/1P+N for single‑phase
  4. Instalação: Incoming side of main / sub‑distribution board, after circuit breaker
  5. Proteção de backup: Series 16–32A circuit breaker (breaking capacity ≥ 50 kA)
  6. Fiação: Short and thick copper cable, length ≤ 50 cm
  7. Manutenção: Check indicator regularly; replace module when red (typical 5–8 years)
  8. Difference Between IPRU40 & IPRD40
RecursoIPRU40IPRD40Descrição
Module typeBasic pluggablePluggable with remote indicationIPRD40 supports remote signal
StatusLocal LEDLocal LED + remote contact1 C/O dry contact
Número do pedido.A9L040xxxA9L40xxxDifferent prefix
PreçoMais baixoHigherDue to remote function
  1. Full List of Schneider Surge Protective Devices (Acti9 Series)
  2. Pluggable Type (iPRU / iPRD, Type 2, mainstream)
SérieModeloImax / EmUcPolonesesNúmero do pedido.Observação
iPRU (Básico)IPRU10‑10KA10 kA / 5 kA350 V1P+N/2P/3P+N/4PA9L010xxxLocal indication
IPRU20‑20KA20 kA / 10 kA350 V1P+N/2P/3P+N/4PA9L020xxxGeneral Type 2
IPRU40‑40KA40 kA / 20 kA350 V1P+N/2P/3P+N/4PA9L040xxxYour model
IPRU65‑65KA65 kA / 30 kA350 V1P+N/2P/3P+N/4PA9L065xxxAlta corrente
IPRU100‑100KA100 kA / 50 kA350 V3P+N/4PA9L100xxxHigh energy
iPRD (Remote)iPRD10/20/40/65Same as iPRU350 V1P+N/2P/3P+N/4PA9L40xxxWith remote dry contact
  1. Tipo Fixo (iST / iPR, Type 2)

iST series: iST20, iST40, iST65 (Imax 20/40/65 kA), order no. A9L916xxx

iPR series: iPR20, iPR40, iPR65 (older fixed type, gradually replaced by iPRU)

  1. Type 1 / Combined Type 1+2

iPRF1‑12.5r: Type 1, Imax = 12.5 kA (10/350 μs), 3P+N/4P, A9L012xxx

iPRD1‑15r/20r/25r: Type 1+2, Imax = 15/20/25 kA, 3P+N/4P

  1. Série Especial

iPRU‑DC: For PV DC systems (500 V / 1000 V DC)

iPTU: For low‑voltage signal lines

EA9L: Easy9 economical fixed type

  1. Cross‑Brand Replacements for IPRU40‑40KA

(Type 2, Imax = 40 kA, In = 20 kA, Uc ≈ 350 V)

  1. Siemens 5SD7 Series

5SD7462‑6CN: 2P, 40 kA/20 kA, 350 V, conectável

5SD7464‑6CN: 4P, 40 kA/20 kA, 350 V, conectável

5SD7466‑6CN: 3P+N, 40 kA/20 kA, 350 V, conectável

  1. Série ABB OVR T2

OVR T2 2L 40‑320 P U: 2P, 40 kA/20 kA, 320 V

OVR T2 4L 40‑320 P U: 4P, 40 kA/20 kA, 320 V

OVR T2 3N 40‑320 P U: 3P+N, 40 kA/20 kA, 320 V

  1. Chinese Brands (Custo-benefício)

CHINT NU6‑II 40 kA/20 kA: 350 V, 1P+N/2P/3P+N/4P

DELIXI DZ47Y 40 kA/20 kA: 350 V, all poles

ZHONGLI ZL1‑40/2‑350: Type 2, 40 kA/20 kA, 350 V

III. Schneider Internal Replacements

Downsizing: IPRU20‑20KA (Imax = 20 kA), for low surge environments

Equal replacement: iPRD40‑40KA (with remote signal)

Upgrading: IPRU65‑65KA (Imax = 65 kA), higher surge protection

  1. Seleção & Replacement Rules
  2. Match core parameters: Imax, Em, Uc, Type 2, poles must be consistent
  3. Mounting compatible: 35 mm DIN rail, similar width
  4. Function difference: iPRD / 5SD7 / OVR have remote contacts; iPRU only local indication
  5. System suitable: All for TT/TN‑S, not for TN‑C