Nome completo do produto: Modicon Premium AS‑Interface V2 Master Module (AS-i Master)
It is a rack-mounted module for Premium (TSX57) CLP. End-of-life (EOL: 2021‑01‑23), end of service: 2026‑12‑31. Não recomendado para novos projetos; only available for spare parts and retrofit of legacy equipment.
- Definição de código de modelo
TSX: Prefix for Modicon Premium series
SAY: AS-i bus master module
1000: Version V2, supports standard and extended addressing
- Especificações principais
| Item | Parâmetro |
| Protocolo de ônibus | AS‑Interface V2, M2E profile |
| Addressing Mode | Standard addressing + extended addressing |
| Slave Capacity | Até 31 slaves in standard mode; analog slaves available with extended addressing |
| Supported Slave Types | Discrete I/O (4I/3O, 4I/4O), AS-i analog slaves, AS-i safety interface slaves |
| Fonte de energia | Powered by Premium rack backplane |
| Backplane Current Draw | 450mA @5VDC |
| Interface | 3-pin male SUB-D, AS-i bus terminal |
| Peso | 0.34kg |
| Max Modules per Rack | TSX570/TSX57C: 1 computador; TSX571: 2 peças; TSX572: 4 peças; TSX573~TSX576: até 8 peças |
| Painel frontal | LEDs de status (PWR/OK/FAULT, A/B group), 32-point slave diagnostic LEDs, 2 botões de operação |
| Software de programação | Unidade Pró |
| Código HS | 85389099 |
- Descrição da função
- Acts as the AS-i bus master for Premium PLC to connect field AS-i sensors and actuators (interruptores de proximidade, válvulas solenóides, modular I/O, etc.), greatly simplifying field wiring.
- Front panel integrated diagnostic LEDs for quick troubleshooting of AS-i bus faults, slave disconnection and address conflicts.
- Supports acquisition from AS-i analog slaves, not limited to discrete signals only.
- Compatible with AS-i safety slaves (entrada de segurança / safety output).
- Modelo de substituição
Official Recommended Replacement: BMXEIA0100 (M340 PLC AS-i Master Module)
Observação: Platform migration from Premium TSX57 to M340 requires rack, CPU and software replacement. It is not a direct plug-and-play replacement. For legacy systems, usado apenas / surplus TSXSAY1000 can be sourced as spare parts.
- Instalação & Diretrizes de Manutenção
- Instalação: DIN rail mounting in Premium rack, X-Bus backplane communication; Classificação de proteção IP20, apenas para instalação em gabinete.
- AS-i Bus: Use dedicated AS-i yellow flat cable; AS-i power supply must be installed at both ends of the bus. SUB-D connector spare: Contato Fênix 1841909, Schneider internal part number W815891970101A.
- Solução de problemas de falhas
FAULT red LED: Bus short circuit, falha de energia, duplicate slave address
A/B LED: Indicate AS-i A/B dual group slaves
32 LEDs: Corresponding slave online status; OFF = slave lost
- Lista de verificação de inspeção de segunda mão
Power on and verify PWR/OK LED without faults
All front panel LEDs light normally, no damage
SUB-D connector free of oxidation and intact pins
Rack gold-plated contacts without burn marks
Perform bus scan test with AS-i power supply and AS-i slave
- Common Misconception Clarification
❌ Not an analog output module. Some vendors incorrectly label it as AO module. It is an AS-i fieldbus communication master module.
TSXSAY1000 (Premium AS-i V2 Master Module) Casos de aplicação
Core feature: TSXSAY1000 is the AS-i bus master mounted on Premium PLC rack. Suitable for scattered field I/O, large quantity of sensors, solenoid valves and safety signal acquisition. One AS-i yellow flat cable transmits data and power simultaneously, drastically reducing hardwiring work. All cases are legacy projects (Premium platform, Unity Pro programming), mainly for retrofit and maintenance of existing equipment. Premium platform is not recommended for new projects.
Caso 1: Linha de montagem de componentes automotivos (Aplicação Típica)
Visão geral do projeto
Controlador principal: TSXP573623M Premium CPU + TSXSAY1000 AS-i master module for one assembly station bus
AS-i slaves: Sensores de proximidade, sensores fotoelétricos, station pushbutton boxes, solenoid valve islands, AS-i safety slaves (portões de segurança, parada de emergência)
I/O count: A/B dual group, around 42 AS-i slaves; includes discrete I/O and a small number of analog slaves (pressure sensor AS-i modules)
Arquitetura do sistema
Premium Rack (TSXP57+TSXSAY1000) → SUB-D Connector → AS-i Yellow Flat Cable → Field AS-i Slaves
Reason for TSXSAY1000 Selection
- Assembly stations are distributed. Traditional hardwiring requires separate cables from each sensor back to control cabinet, with high cost of cables, trunking and wiring labor. AS-i single cable connects all points in series.
- AS-i Safety support: Safety gate and E-stop signals transmitted via AS-i safety channel, natively supported by TSXSAY1000.
- Front panel 32-channel diagnostic LEDs allow maintenance personnel to identify offline slaves at a glance for fast fault location.
Lógica de Controle
Material presence detection at station, cylinder solenoid valve actuation, safety gate interlock, proteção de parada de emergência
Analog pressure acquisition (press-fit pressure) uploaded to PLC for press-fit judgment
Pain Points & Manutenção
Falhas: AS-i flat cable insulation damage, poor contact from piercing terminals. TSXSAY1000 FAULT LED alarm, read bus diagnostic word in Unity Pro.
Limitação: Max bus length ≤100m; AS-i repeater required for longer distance.
Retrofit Alternative
Full Premium platform replacement: M340 + BMXEIA0100 AS-i master
Caso 2: Food Packaging Line (Envoltório de fluxo horizontal / Case Packer)
Visão geral do projeto
Premium TSXP57254M + TSXSAY1000; case conveying line with multi-section belt conveyors, material stop cylinders and detection photoelectric sensors
AS-i slaves: Photoelectric sensors, material presence switches, válvulas solenóides, AS-i modular I/O
Requisito de Processo
Multi-section conveyor sorting, material detection, material stop and reject. Field I/O points scattered along long conveying line.
Vantagens
- Humid environment in packaging workshop. AS-i flat cable with piercing connection, fast wiring, M12 waterproof slaves.
- Simple configuration in Unity Pro for TSXSAY1000, automatic slave scan and I/O mapping.
- Add new slaves directly on AS-i bus when expanding stations, no massive recabling.
Typical Fault
Insufficient AS-i power capacity. Voltage drop occurs when multiple solenoid valves energize simultaneously, causing temporary slave dropout reported by TSXSAY1000.
Caso 3: Automated Warehouse Conveyance & Pallet Detection
Visão geral do projeto
Pallet inbound conveyor section in automated warehouse, Premium PLC + TSXSAY1000 to manage scattered detection points on conveyor line
AS-i slaves: Pallet presence photoelectric sensors, position proximity switches, stop cylinder solenoid valves, pallet oversize detection
Processo
Pallet inbound, position identification, stop and release. I/O points spread along long conveyor, control cabinet installed at one end of warehouse.
Justificativa de Seleção
Traditional point-to-point wiring incurs extremely high cable cost. AS-i cable routed along conveyor cable tray with single drop branches. TSXSAY1000 supports up to 62 discrete AS-i slaves, sufficient for one inbound conveyor line.
Observação: For multi-bus warehouse projects, multiple TSXSAY1000 modules can be installed on Premium rack (até 8 modules for TSX573 and above) to expand multiple independent AS-i buses.
Caso 4: Valve Island & Level Switch Acquisition in Wastewater Treatment Plant (Indústria de Processos)
Visão geral do projeto
Wastewater pre-treatment, mechanical bar screens and sludge discharge valve banks; Premium PLC, TSXSAY1000, field AS-i valve islands + interruptores de nível
AS-i slaves: Pneumatic valve AS-i valve islands, interruptores de nível, flow switches, 4-20mA AS-i analog modules
Processo
Bar screen start/stop, on/off control of sludge discharge valves, liquid level monitoring. Valve groups distributed around tanks under humid and corrosive environment.
Características
TSXSAY1000 supports AS-i analog slaves for direct acquisition of liquid level and pressure analog signals, eliminating large quantity of additional analog input modules.
Consideration
AS-i bus is not suitable for ultra-long distance wiring across tanks; AS-i repeater required if length exceeds 100m.
Summary of TSXSAY1000 Application Profile
✅ Cenários adequados
- Scattered field sensors and actuators, large volume of discrete I/O (fotoelétrico, proximity, válvulas solenóides)
- Systems requiring AS-i safety bus (portões de segurança, parada de emergência)
- Small volume analog acquisition (pressão, liquid level via AS-i slaves)
- Retrofit and spare part replacement of legacy Premium systems
❌ Cenários inadequados
- High-speed process and heavy analog volume applications (Profibus / Modbus TCP preferred)
- Long bus distance (>100m without repeater)
- Novos projetos (Premium platform EOL, M340+BMXEIA0100 recommended)
Configuration Guidelines (Unidade Pró)
- Insert TSXSAY1000 into hardware tree of Premium rack
- Configure AS-i V2, padrão / extended addressing
- Bus scan to identify group A / B slaves
- Automatically map AS-i input and output to PLC internal variables
- Read module diagnostic word for SCADA alarm (bus fault, slave dropout)
Schneider Modicon Premium AS-i V2 Master Module TSXSAY1000 Full Technical Specifications
Posicionamento do produto: AS‑Interface V2 fieldbus master module for Premium PLC rack. EOL, configured by Unity Pro software.
- Informações Básicas
| Item | Parâmetro |
| Modelo | TSXSAY1000 |
| Família de produtos | Modicon Premium (TSX57) |
| Tipo de módulo | AS‑Interface V2 Bus Master |
| AS-i Profile | M2E |
| Programas | Unidade Pró |
| Código HS | 85389099 |
| Peso líquido | 0.34 kg |
- Bus Communication Parameters
| Item | Parâmetro |
| AS-i Version | AS‑Interface V2 |
| Addressing Mode | Standard addressing + extended addressing (A/B dual group) |
| Max Slave Quantity | Standard addressing: 31 unidades; extended addressing: 31 unidades; maximum total 62 discrete slaves |
| Supported Slave Types | Discrete I/O slaves (standard 4I/4O, extended 4I/3O), AS-i analog slaves, AS-i safety interface slaves (portão de segurança, parada de emergência) |
| Bus Medium | AS-i dedicated yellow flat cable |
| Max Bus Length | 100eu (without repeater) |
| Bus Power | External independent AS-i power supply (backplane only supplies module itself, not AS-i bus power) |
- Parâmetros Elétricos
| Item | Parâmetro |
| Fonte de alimentação do módulo | Premium rack X-Bus backplane 5VDC |
| Consumo atual do backplane | 450mA @5VDC |
| Interface de ônibus | 3-pin male SUB-D (AS-i+, AS-i-) |
- Rack Configuration (Max TSXSAY1000 Quantity per Premium CPU)
| CPU Model | Max TSXSAY1000 Quantity |
| TSX570 / TSX57C | 1 computador |
| TSX571 | 2 peças |
| TSX572 | 4 peças |
| TSX573 / TSX574 / TSX575 / TSX576 | 8 peças |
- LEDs do painel frontal & Operation Buttons
Indicadores LED de status
- PWR OK (Verde): Backplane power supply of module normal
- FAULT (Vermelho): AS-i bus fault, curto-circuito, slave loss, address conflict
- A/B (Verde): A-group / B-group slave group indicator
- 32 Diagnostic LEDs: Não.0~31, slave online status; OFF = slave offline
Botões
- A/B: Toggle display between A-group and B-group slave status
- MODO: Off-line / online switch, slave initialization, infrared address setting support
- Ambiental & Especificações Mecânicas
| Item | Parâmetro |
| Classe de Proteção | IP20 (cabinet use only) |
| Temperatura ambiente operacional | 0 ℃ ~ +60 ℃ |
| Temperatura de armazenamento | -25 ℃ ~ +70 ℃ |
| Vibration Test | IEC 60068‑2‑6 Fc |
| Shock Test | IEC 60068‑2‑27 Ea |
| Método de montagem | Slot installation on Premium rack backplane |
- Destaques Funcionais
- Supports AS-i Safety safety bus, safety slave connection for safety gate and emergency stop signal acquisition.
- Supports AS-i analog slaves for pressure, liquid level analog signal acquisition.
- Built-in bus diagnostics; diagnostic word readable in PLC program for SCADA alarm.
- Supports automatic bus scan, slave address detection and conflict detection.
- Limitation Notes
- ❗ Not an I/O module. It is a fieldbus communication master module without local I/O points.
- EOL spare part only, not recommended for new projects. Official hardware migration: M340 + BMXEIA0100.
- AS-i bus is not suitable for high-speed mass analog transmission; AS-i repeater required when bus length exceeds 100m.