Relé de monitoramento de segurança Schneider XPSAV11113-24VDC

Model Segment Definition XPSAV11113-24VDC XPSAV: Schneider Safety Monitoring Relay Series, dedicated to dual-channel safety circuits for emergency stop, safety door and safety light curtain. 11113: Internal contact logic and channel configuration code. 24CCV: Rated power supply 24V DC. Core Basic Parameters Item Specification Brand Schneider Product Type Industrial Safety Relay (Dual-channel Redundant Safety Type) Avaliado ...

  • Detalhes do produto
  1. Model Segment Definition

XPSAV11113-24VDC

XPSAV: Schneider Safety Monitoring Relay Série, dedicated to dual-channel safety circuits for emergency stop, safety door and safety light curtain.

11113: Internal contact logic and channel configuration code.

24CCV: Rated power supply 24V DC.

  1. Core Basic Parameters
ItemEspecificação
MarcaSchneider
Tipo de produtoIndustrial Safety Relay (Dual-channel Redundant Safety Type)
Rated Supply24CCV
Faixa de tensão20.4~26.4VDC
Nível de segurançaPL d / Cat.3, SIL2
Tipo de montagemDIN35 Rail Mounting
Cenários de aplicaçãoMáquinas-ferramentas, automatic production lines, robot emergency stop / safety door circuits
  1. Principais recursos
  2. Dual-channel redundant input with safety forced-guided contacts;
  3. Millisecond-level safety cut-off response;
  4. Only supports 24V DC power supply; AC voltage input is prohibited;
  5. Built-in self-diagnosis and circuit monitoring functions.
  6. Compatible Replacement Models
  7. Same-brand direct replacement: Direct replacement with the same model; no upgraded alternative version
  8. Doméstico / Cross-brand compatible models:

Omron G9SA-301 24VDC

Weidmüller Dual-channel Safety Relay 24VDC

Siemens 3RK3 series 24V safety module with equivalent specifications

  1. Notas de aplicação

Safety signals must be connected synchronously through dual channels; single-channel connection cannot work normally;

Strictly prohibit mixed use with AC24V power supply, which will directly burn out the module;

Output contacts are only used for safety circuit control and cannot directly drive heavy loads.

Schneider Safety Monitoring Relay Series List & Comparação entre marcas

  1. Overview of Core Schneider Safety Monitoring Relay Series

Os relés de monitoramento de segurança da Schneider estão centrados na série Preventa XPS, cobrindo funções de segurança de cenário completo, como parada de emergência, porta de segurança, cortina de luz de segurança e controle bimanual. Eles são divididos em Tipo Básico e Tipo Universal, todos em conformidade com EN/ISO 13849-1 e CEI 61508 padrões de segurança.

SérieFunção principalNível de segurançaAplicação Típica
XPSAVDual-channel emergency stop / safety door monitoring with solid-state outputPL e / Cat.4, SIL3Emergency stop circuits for machine tools and automatic production lines
XPSAF/XPSAFLEmergency stop / porta de segurança / light curtain monitoring, high/low level inputPL e/Cat.4(SIL3) / PL d/Cat.3(SIL2)Safety light curtain and safety door interlock monitoring
XPSACEmergency stop button and limit switch monitoringPL e / Cat.4, SIL3Simple emergency stop circuit and equipment limit protection
XPSARDual-channel emergency stop / light curtain monitoring, 7 safety contacts + 2 contatos auxiliaresPL e / Cat.4, SIL3Complex safety circuits and multi-equipment linkage
XPSATE/XPSATRConfigurable safety relay with time delay functionPL e / Cat.4, SIL3Safety scenarios requiring delay control
XPSCMDedicated monitoring module for light curtainsPL e / Cat.4, SIL3Safety light curtain / grating monitoring
XPSUAF/XPSUATUniversal configurable safety relayPL e / Cat.4, SIL3Replacement for XPSAR / XPSATE series
  1. Model Segment Coding Rules

Taking XPSAV11113-24VDC as an example, Schneider safety relay model coding follows unified logic:

Segmento de códigoSignificadoExample Description
XPSProduct category identifier, Preventa safety relay seriesAll safety relays start with this prefix
AV/AF/AC/AR/ATEFunctional series codeAV=Emergency stop + solid-state output; AF=Standard emergency stop; AC=Basic emergency stop
11113Internal configuration code1st digit = channel quantity; last four digits = contact type / quantidade / reset mode
-24VDC/230VACRated supply voltage24Em DC / 230V e; some models support universal AC/DC
PIdentificador de tipo de terminal (opcional)P=Plug-in terminal; no suffix=screw terminal
  1. Complete Model List of Each Series

3.1 XPSAV Series (Parada de Emergência + Solid-State Output)

ModeloTensão de alimentaçãoSafety ContactsAuxiliary OutputModo de reinicialização
XPSAV11113-24VDC24CCV3NO Instantaneous3 Solid-state OutputAutomático / Monitored Reset
XPSAV11113P-24VDC24CCV3NO Instantaneous3 Solid-state OutputAutomático / Monitored Reset (Plug-in Terminal)
XPSAV11123-24VDC24CCV3NO Instantaneous + 3NO Time-delay3 Solid-state OutputRedefinição manual
XPSAV11123P-24VDC24CCV3NO Instantaneous + 3NO Time-delay3 Solid-state OutputRedefinição manual (Plug-in Terminal)
XPSAV37113-230VAC230VAC3NO Instantaneous3 Solid-state OutputAutomático / Monitored Reset
XPSAV37113P-230VAC230VAC3NO Instantaneous3 Solid-state OutputAutomático / Monitored Reset (Plug-in Terminal)

3.2 XPSAF/XPSAFL Series (Standard Emergency Stop / Light Curtain Monitoring)

ModeloTensão de alimentaçãoNível de segurançaTipo de entradaSafety Contacts
XPSAF513024VAC/DCPL e / Cat.4High/Low Level Dual-channel3NÃO
XPSAF5130P24VAC/DCPL e / Cat.4High/Low Level Dual-channel3NÃO (Plug-in Terminal)
XPSAF5130P-230VAC230VACPL e / Cat.4High/Low Level Dual-channel3NÃO (Plug-in Terminal)
XPSAFL513024VAC/DCPL d / Cat.3High Level Dual-channel3NÃO (No Short-circuit Detection)
XPSAF3730P230VACPL e / Cat.4High/Low Level Dual-channel3NÃO (Plug-in Terminal)

3.3 XPSAC Series (Basic Emergency Stop Monitoring)

ModeloTensão de alimentaçãoSafety ContactsCaracterísticas
XPSAC512124CCV2NÃOTipo Básico, Cat.3
XPSAC5121P24CCV2NÃOTipo Básico, Cat.3 (Plug-in Terminal)
XPSAC3721P230VAC2NÃOTipo Básico, Cat.3 (Plug-in Terminal)
XPSAC514024CCV4NÃOTipo aprimorado, Cat.4

3.4 XPSAR Series (Multi-contact Emergency Stop / Light Curtain Monitoring)

ModeloTensão de alimentaçãoSafety ContactsContatos AuxiliaresCaracterísticas
XPSAR311144P24VAC/DC7NÃO2NCDual-channel, Cross-wire Monitoring
XPSAR351144P115VAC7NÃO2NCDual-channel, Cross-wire Monitoring
XPSAR371144P230VAC7NÃO2NCDual-channel, Cross-wire Monitoring

3.5 Universal XPSU Series (Replacement for Traditional Series)

ModeloReplaced SeriesTensão de alimentaçãoSafety ContactsContatos Auxiliares
XPSUAF13APXPSAF24VAC/DC3NÃO1NC (Diagnostic Output)
XPSUAF13ACXPSAF24VAC/DC5NÃO4 Contatos Auxiliares
XPSUAT13A3APXPSATE24VAC/DC3NÃO + 3 Time-delay NO3 Solid-state Output
  1. Cross-Brand Comparison Table (Modelos convencionais)
Schneider ModelOmron ReplacementSiemens ReplacementPilz ReplacementWeidmüller Replacement
XPSAV11113-24VDCG9SA-301 24VDC3SK1111-2AB40PNOZ X3 24VDCSAFESERIES 24VDC Dual-channel
XPSAF5130G9SA-501 AC/DC243SK1122-2AB40PNOZ X4 24VAC/DCPROMAX 24VAC/DC 3NO
XPSAC5121G9SA-101 24VDC3SK1101-2AB40PNOZ X1 24VDCSAFESERIES 24VDC 2NO
XPSAR311144PG9SA-321 AC/DC243SK1162-2AB40PNOZ X7 24VAC/DCPROMAX 24VAC/DC 7NO+2NC
XPSUAF13APG9SA-511 AC/DC243SK2122-2AB40PNOZ X4P 24VAC/DCPROMAX 24VAC/DC 3NO+Diagnostic
  1. Diretrizes de seleção & Replacement Precautions
  2. Safety Level Matching: The PL / Cat. level and SIL level of the replacement model shall not be lower than the original one.
  3. Input Type Compatibility: Distinguish High/Low Level Input and PNP/NPN types; XPSAF supports dual types, while XPSAFL only supports high level.
  4. Consistent Reset Mode: Divided into Automatic Reset, Monitored Reset and Manual Reset, which shall match the application scenario.
  5. Tipo de terminal: Suffix P stands for plug-in terminal; no suffix for screw terminal. Pay attention to mounting compatibility during replacement.
  6. Tensão de alimentação: Strictly distinguish DC24V, AC230V and Universal AC/DC to avoid module burnout.
  7. Series Replacement Roadmap

Schneider is gradually replacing traditional series with the XPSU Universal Series:

XPSAR → Combined XPSUAF + XPSUEP or XPSUAT series

XPSATE/XPSATR → XPSUAT series

XPSAF/XPSAV → XPSUAF series