Válvula solenóide pneumática SHAKO PU520-02S-DC24V

Marca: SHAKO (Taiwan) | 5/2 Caminho, Single Solenoid, Internal Pilot Pneumatic Solenoid Valve ✅ Model Code Definition PU520: 5/2 five-port two-position valve 02: Main port G1/4″; Exhaust port G1/8″ S: Solenóide único (retorno na primavera, monoestável) CC24V: Tensão da bobina DC24V (Order code No.9) Standard thread: G thread; Opcional: TNP / Rc Suffix L = with LED ...

  • Detalhes do produto

Marca: SHAKO (Taiwan) | 5/2 Caminho, Single Solenoid, Internal Pilot Pneumatic Válvula Solenóide

✅ Model Code Definition

PU520: 5/2 five-port two-position válvula

02: Main port G1/4″; Exhaust port G1/8″

S: Solenóide único (retorno na primavera, monoestável)

CC24V: Tensão da bobina DC24V (Order code No.9)

Standard thread: G thread; Opcional: TNP / RC

Suffix L = with LED indicator

📌 Core Technical Specifications

ItemParâmetro
MédioClean dry compressed air
Effective sectional area18 mm²
Pressão operacional0.15~0,8 MPa (1.5~8 kgf/cm²)
Pressão de prova0.99 MPa
AtuaçãoInternal pilot
CorpoLiga de alumínio anodizado
Temperatura ambiente-10℃ ~ +60 ℃
Ciclo de trabalho100% DE (continuous energization available)
Classe de proteçãoIP65 (DIN socket assembly)
Classe de isolamentoClasse F
Tolerância de tensão±10%
Peso líquido270 g
Standard accessoryLockable manual override button for commissioning

📎 Matching Parts & Alternativas

  1. Manifold base: MF520-02 (multi-station manifold available)
  2. Energy-saving upgrade: E-PU520-02S-DC24V, lower power consumption and less heat rise for long-term energization
  3. Cross-brand equivalent models:

ártico: 4V210-08 DC24V

Mindman: MVSC-220-4E1 DC24V

⚠️ Notas importantes

Single solenoid design: auto return when power off. Select PU520-02D (solenóide duplo) for latching function without power supply.

Internal pilot requires minimum inlet pressure ≥ 0.15 MPa. Select external pilot type PU520A for low-pressure or vacuum applications.

Standard DIN43650 socket; LED version with suffix L is optional.

Complete Technical Datasheet — SHAKO PU520-02S-CC24V

Nome completo: PU520-02-S DC24V 5/2-Way Internal Pilot Single Solenoid Valve (PU Series Pilot Valve)

Original PDF source: SHAKO official PU520 series catalogue

  1. Codificação de modelo

PU520 02 S DC24V

PU520: 5/2 five-port two-position pilot solenoid valve

02: Main air port G1/4″; Exhaust port G1/8″

S: Solenóide único, retorno na primavera (auto reset on power loss)

CC24V: Tensão da bobina DC24V

Thread default: G; Optional Rc (PT), TNP; Suffix L = with LED indicator

  1. Recursos do produto
  2. Medium-size body with large flow capacity, effective area 18 mm²
  3. Equipped with lockable manual override, no electricity or air supply needed for field test
  4. Anodized aluminum body, wear-resistant and long service life
  5. DIN43650 standard socket, IP65 protection suitable for industrial sites
  6. Can be mounted on manifold or with individual base
  7. Optional energy-saving coil E-PU520-02S-DC24V, low power and low temperature rise
  8. Rated Technical Data
ParâmetroValor
Função5/2 five-port two-position, piloto interno
ControlarSolenóide único, retorno na primavera
FluidoClean dry compressed air
Main portG1/4″
Porta de exaustãoG1/8″
Effective area18 mm²
Pressão operacional0.15~0,8 MPa (1.5~8 kgf/cm²)
Minimum actuating pressure≥0.15 MPa (limit for internal pilot)
Pressão de prova0.99 MPa
Temperatura ambiente-10℃ ~ +60 ℃
Ciclo de trabalho100% DE (continuous power-on)
Grau de proteçãoIP65 (with DIN socket fully sealed)
Classe de isolamentoF
Tolerância de tensão±10%
Peso líquido270 g
Material do corpoLiga de alumínio anodizado
Material de vedaçãoBorracha nitrílica NBR (padrão)
Standard manifold baseMF520-02 (multi-station: MF520-02-02 / 03 …)

⚠️ Do not use this internal pilot model under low pressure or vacuum; choose PU520A-02S (piloto externo) em vez de

  1. Definição de porta (5/2 Caminho)

P: Entrada (G1/4)

UM: Saída 1 (G1/4)

B: Saída 2 (G1/4)

R, S: Duas portas de escape (G1/8)

De-energized state: P ↔ A open; B ↔ S exhaust

Energized state: P ↔ B open; A ↔ R exhaust

Auto reset to P-A open when power cuts off (single solenoid characteristic)

  1. Bobina & Fiação (DC24V DIN43650)

Definição de alfinete: 1(+), 2(-), Terra PE

Non-polarized coil version: terminais 1 & 2 can be swapped; LED version is polarized – wrong polarity only causes indicator off without damaging the valve

Consumo de energia: Standard coil ≈4.8W; E energy-saving coil ≈1.2W

Cable outer diameter: Φ6~Φ8mm; use waterproof cable gland

Grounding is mandatory; install full sealing gaskets for dusty & splash environments

  1. Overall & Dimensões de montagem (PU520-02-S)

Body width: 26 milímetros

Furos de montagem: 2×Φ4.3; hole spacing: 70 milímetros

Altura total (with coil & tomada): aprox.. 100 milímetros

Comprimento total: aprox.. 130 milímetros

Two mounting options:

  1. Montagem em coletor: fixed on MF520-02 (recommended for multi-valve centralized control)
  2. Individual pipe mounting: with separate base

Manifold MF520-02 supports 2~10 stations, with blanking plugs and mufflers optional

  1. Instalação, Comissionamento & Operation Rules

Instalação

  1. Install air filter (≥40μm) upstream; air treatment triple unit is recommended; no oil & dirt contamination allowed
  2. No strict mounting orientation; keep coil facing upward to avoid water accumulation
  3. Purge all piping before connecting the valve to prevent metal chips jamming the spool
  4. Install mufflers on exhaust ports for noise reduction and dust prevention; never block exhaust ports

Manual Override Button

Press down: force spool to shift; rotate 90° to lock the shifted position for continuous testing

Reiniciar: turn back to unlock; spring resets automatically after release

Manual lock is only for commissioning; do not keep locked during normal operation

Power-on Commissioning Sequence

  1. Supply compressed air up to rated pressure and check for air leakage
  2. Apply DC24V power and verify cylinder movement; check LED lamp (L model)
  3. Cut power to confirm automatic spring reset
  4. Troubleshooting List
FaltaInspection Items
No shifting when energized1. Voltage below 21.6V; 2. Pilot orifice blocked; 3. Inlet pressure lower than 1.5 bar; 4. Coil burned out
Fail to reset after power offStuck return spring; spool jammed by foreign matter; blocked exhaust port
Continuous air leakage at body or exhaust portSelos desgastados; spool scratched by dirt; pressure exceeding upper limit
Slow actionPoor exhaust, clogged muffler, insufficient air pressure
Bobina superaquecidaVoltage higher than 26.4V; continuous overload; non-100%ED coil selected
  1. Lista de peças sobressalentes
  2. Manifold base: MF520-02 (1-estação), MF520-02-XX (multi-station)
  3. DIN socket: Standard socket / LED indicator socket
  4. Muffler: BSL-M5 / BSL-01 (fits G1/8 exhaust port)
  5. Blanking plugs, juntas, separate coil assembly
  6. Isolation block SOB52-02: Replace valve without shutting down main air supply (online maintenance without line stop)
  7. Modelos equivalentes entre marcas

ártico: 4V210-08 DC24V

Mindman: MVSC-220-4E1 DC24V

Quélica: SV-5201 DC24V

Observação: Mounting hole pitch and base are not interchangeable; only function & port size match

  1. Cronograma de Manutenção

Ambiente normal: Blow exhaust ports and check air leakage every 3 meses

Dust/humid environment: Inspeção mensal; disassemble & clean spool and inspect NBR seals every 6 meses

Seal service life: Aprox.. 5 million switching cycles; replace seal kit before reaching cycle limit

Working Principle — SHAKO PU520-02S-DC24V

5/2 five-port two-position, solenóide único, internal pilot solenoid valve

Princípio fundamental: The coil only actuates a small pilot valve; air pressure difference from main supply pushes the main spool to shift; spring resets automatically when power cuts off (not direct pull by coil like direct-acting valves)

Estrutura Interna

  1. Solenoid assembly (DC24V coil + armadura): controls the small pilot valve
  2. Pilot air circuit: piloto interno, air is tapped from P inlet; no external control air required
  3. Carretel principal & mola de retorno
  4. Five ports: P (entrada), A/B (outlets), R/S (exhausts)

Key limitation: Internal pilot needs minimum inlet pressure ≥0.15 MPa (1.5 bar) to build pressure difference for spool actuation; select PU520A external pilot for low-pressure & vacuum applications

  1. De-energized State (Posição normal, Spring Return)

Bobina desenergizada, armature drops, pilot valve closes; pilot control chamber vents

Right-side return spring pushes main spool to left

Air circuit: P ↔ A open; B ↔ S exhaust

Cylinder A side air inlet, B side exhaust; cylinder stays at initial position

  1. Energized State (DC24V Powered On)

Bobina energizada, magnetic force pulls armature up; pilot valve opens

Compressed air from P inlet flows through pilot hole into right-side control chamber

Pressure on right side overcomes spring force; air pressure pushes main spool to shift

Air circuit switches: P ↔ B open; A ↔ R exhaust

Cylinder B side air inlet, A side exhaust; cylinder reverses movement

  1. Power Cut Off Again

Magnetic force disappears, pilot valve closes; air inside pilot chamber vents out from pilot exhaust hole

Main spool is pushed back to original position by return spring; air circuit reverts to P-A open status

✅ Feature of single solenoid (S): auto reset on power loss (monoestável); select double solenoid (D) for position latching without power supply.

Manual Override Principle

The lockable manual push button mechanically actuates the pilot spool without power or air supply, simulating energized status for field commissioning. Rotate 90° to lock the shifted position; remember to unlock after testing.

Advantages over Direct-Acting Valves

Baixa potência da bobina (≈4.8W), tamanho pequeno, aumento de baixa temperatura

Large spool flow capacity (18 mm² effective area)

Suporta 100% continuous energization (100% DE)

Desvantagem: Minimum actuating pressure threshold; cannot work under zero pressure

Air Circuit Logic Summary

StatusOpen PathExhaust Path
Desenergizado (Normal)P→AB→S
EnergizadoP→BA→R

SHAKO Solenoid Valve Full Series Catalogue (Por função & Tamanho)

Observação: PU, SOU, BM, PN, PS, CY = pneumatic directional control valves (5/2,5/3,3/2); PU220/SPU220/PU225 = 2/2 fluid valves (ar, água, óleo); Prefix E = energy-saving low-power coil

Suffix General Definition

S: Solenóide único (retorno na primavera, monoestável)

D: Solenóide duplo (latching, no power hold)

UM: Piloto externo (vazio & low-pressure use)

B: Built-in silencer

X/Y: 5/3-way mid-position function (X=closed center; Y=exhaust center; Z=pressurized center)

eu: Com indicador LED

E: Bobina economizadora de energia

Port code: 01=G1/8; 02=G1/4; 03=G3/8; 04=G1/2

  1. 5/2 2-Position 5-Port / 5/3 3-Position 5-Port Pilot Solenoid Valves (Main cylinder control)

AM520 Series (18mm narrow body, Porta G1/8, equivalent to Airtac 4V110)

AM520-01S / AM520-01D (5/2 single/double solenoid)

AM530X/Y-01D (5/3 closed/exhaust/pressurized center)

AM520A: Piloto externo; AM520B: Built-in silencer

Matching manifold: MF520-01

BM520 Series (22mm largura, Porta G1/4, equivalent to Airtac 4V210)

BM520-02S / BM520-02D

BM530X/Y-02D (5/3 three-position)

BM520A: Piloto externo; E-BM520: Versão economizadora de energia

Matching manifold: MFB520-02

PU520 Series (Your selected medium size, 26mm largura, grande fluxo, G1/4~G1/2)

PU520-02S/D, PU520-03S/D, PU520-04S/D (5/2 two-position)

PU530X/Y-02D, PU530X/Y-03D, PU530X/Y-04D (5/3 three-position)

PU520A: Piloto externo (vacuum/low pressure); PU520AB

E-PU520: Bobina economizadora de energia (baixa potência & low heat)

Matching manifold: MF520-02 / MF520-03 / MF520-04

BW520 Series (Wide body high flow, G3/8 & G1/2, equivalent to 4V410)

BW520-03S/D, BW520-04S/D

BW530X/Y-03D, BW530X/Y-04D

PS520 Series (ISO standard mounting, ISO1/ISO2 interchangeable base)

PS520-02S/D, PS520-03S/D, PS520-04S/D

PS520F: ISO flange mounting

E-PS520: Energy-saving model

CY520 / CY525 Series (Economical pilot valves)

CY520-02S/D, CY520-03S/D

E-CY520, E-SCY520 (SUS316 stainless steel anti-corrosion version)

CY525: Combinado 3/2 + 5/2 função

  1. 3/2 3-Port 2-Position Pilot Solenoid Valves (Single-acting cylinder, vazio & controle de sopro)

PU320 / PU322N: 3/2 pilot type, porta 01/02/03/04

BM320: 3/2 pilot valve

E-AM325: Energy-saving direct-acting 3/2 válvula

III. 2/2 2-Port 2-Position Solenoid Valves (Controle de fluidos: ar, água, óleo, vapor, corrosive low-pressure media)

Ação direta / pilot-operated; brass body / SUS316 stainless steel; normalmente fechado (NC) como padrão

  1. PU220A Direct-acting (baixa pressão & vacuum applicable)

PU220A-01/02/03/04/06/08

  1. SPU220AR SUS316 stainless steel direct type, anti-corrosion for air & água

SPU220AR-01/02/03; E-SPU220AR energy-saving version

  1. PU225X Pilot-operated 2/2 (high pressure large flow, máx.. 50 bar)

PU225X-03/04/06/08

  1. PU225S Steam-specific 2/2 válvula; flange type PU225SF
  2. DC220 Large-bore 2/2 válvula (3/4″~3″, dust removal & fornecimento de água)
  3. Modelos Especiais

E-SPU520: SUS316 stainless steel 5-port pilot valve for corrosive environment

Explosion-proof coil optional: Compatible with PU/BM/PS series, ATEX T4 certified

Pneumatic pilot valves (sem solenóide): PA520, PB520, PP520, same body size as solenoid versions

  1. Selection Cross Reference Table
SérieLargura do corpoStandard PortEquivalent Airtac Model
AM52018milímetrosG1/84V110-06
BM52022milímetrosG1/44V210-08
PU52026milímetrosG1/4~1/24V310-10 / 4V410-15
BW520Alto fluxoG3/8, 1/24V410-15
PS520ISO standardG1/4~1/2ISO standard valve
  1. Manifold Naming Rule

MF520-02-03: PU520 series, Rosca G1/4, 3-coletor de estação; MFB520 = dedicated manifold for BM520 series