Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Disjuntor em caixa moldada Siemens 3VT8-63H102 (MCCB) - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

disjuntor/

Disjuntor em caixa moldada Siemens 3VT8-63H102 (MCCB)

Model SegmentSpeculative MeaningDescrição
3VT8Siemens SENTRON 3VT8 Series Molded Case Circuit BreakerDiscontinued, replaced by 3VA/3VM/3VC series
63Corrente nominal (Em): 63UMMaximum current for long-term operation at 40掳C ambient temperature
HClasse de Capacidade de Quebra: Class H (50o)Breaking capacity classes of 3VT8 series: Class N (25o), Class H (50o), Class L (65o)
102Speculated as a combination of frame current + pole number/trip unit type100Um quadro (VT100), 2-pole configuration, Thermal-Magnetic Trip unit (TMF)

  • Detalhes do produto

Model Designation Interpretation (Speculative, Based on 3VT8 Series Naming Rules)

The model “3VT8-63H102provided by the user is a simplified version; the complete model usually contains more detailed information. The speculative meaning of each part is as follows:

Model SegmentSpeculative MeaningDescrição
3VT8Siemens SENTRON 3VT8 Series Disjuntor em caixa moldadaDiscontinued, replaced by 3VA/3VM/3VC series
63Corrente nominal (Em): 63UMMaximum current for long-term operation at 40掳C ambient temperature
HClasse de Capacidade de Quebra: Class H (50o)Breaking capacity classes of 3VT8 series: Class N (25o), Class H (50o), Class L (65o)
102Speculated as a combination of frame current + pole number/trip unit type100Um quadro (VT100), 2-pole configuration, Thermal-Magnetic Trip unit (TMF)

Most Probable Corresponding Complete Models: 3VT8106-1AA03-0AA0 (3-pólo, 63UM, Class H breaking capacity, TMF trip unit) or 3VT8106-1AA04-0AA0 (4-pólo)

  1. Parâmetros de especificação principal (Based on 3VT8 100H 63A TMF)
Item de parâmetroSpecification ValueDescrição
Tipo de produtoDisjuntor em caixa moldada (MCCB)Used for overload and short-circuit protection in power distribution systems
Quadro atual (Iu)100UMVT100 frame, compatible with a maximum rated current trip unit of 63A
Corrente nominal (Em)63UMRated operating current at 40掳C ambient temperature
Ultimate Breaking Capacity (UTI)50o (415/440V e)Class H breaking capacity, meeting the requirements of industrial power distribution systems
Tipo de unidade de viagemThermal-Magnetic Trip unit (TMF)Proteção contra sobrecarga (thermal element): inverse time characteristic; Proteção contra curto-circuito (magnetic element): instantaneous tripping
Número do pólo3-pole or 4-pole3-pole is commonly used in power distribution systems; 4-pole is adopted when neutral wire protection is required
Rated Operational Voltage (Ué)400/415V eSuitable for three-phase industrial power distribution systems
Tensão nominal de isolamento (interface do usuário)690V eCompatível com IEC 60947-2 padrão
Temperatura operacional-25C ~ +70CDerating is required when the temperature exceeds 40C
Método de fiaçãoFront Panel WiringRear panel wiring or plug-in connection is optional
Método de operaçãoRotary HandleElectric operating mechanism is optional for remote control

III. Product Features and Advantages

  1. Alta confiabilidade: A member of Siemens SENTRON series, compliant with the international IEC 60947-2 padrão.
  2. High Breaking Capacity: Class H 50kA breaking capacity, effectively interrupting short-circuit faults and protecting equipment safety.
  3. Flexible Configuration: Compatible with a variety of accessories (contatos auxiliares, contatos de alarme, shunt release, undervoltage release, etc.).
  4. Projeto de Segurança: Lockable rotary operating mechanism to prevent misoperation; Terminal cover protection for enhanced safety.
  5. Compact Size: Saving switchgear space, facilitating installation and maintenance.
  6. Cenários típicos de aplicação
  7. Industrial Power Distribution Systems: Used as incoming/outgoing circuit breakers in distribution boxes to protect cables and lines.
  8. Proteção do Motor: Serves as protection equipment for direct starting of three-phase squirrel-cage motors, providing overload and short-circuit protection.
  9. Transformer/Capacitor Protection: Protecting distribution transformers and compensation capacitors to prevent fault expansion.
  10. Main Switch/Emergency Stop Switch: Combined with a lockable operating mechanism, used as the main switch and emergency stop control for equipment or systems.
  11. Building Automation: Applied in power distribution protection for lighting, air conditioning and other systems in commercial buildings and industrial plants.
  12. Important Notes and Alternative Solutions
  13. Product Status

The 3VT8 series was officially discontinued in January 2024 and fully replaced by Siemensnew-generation 3VA/3VM/3VC series molded case circuit breakers. The 3VT8 series is no longer in production, with only limited spare parts support available.

  1. Modelos alternativos recomendados (Based on 63A, Class H Breaking Capacity, 3-pólo, TMF Trip Unit)
Alternative SeriesRecommended ModelVantagens
3VA1 Series3VA1063-3ED36-0AA0Higher breaking capacity (25kA→36kA), more advanced tripping technology, richer accessory options
3VM Series3VM1063-1EA00-0AA0Cost-effective, suitable for basic power distribution applications, easy to install
3VC Series3VC1063-1AA00-0AA0Thermal-magnetic and electronic trip units optional, high intelligence level, supporting communication functions
  1. Precautions for Use
  2. Derating Operation: When the ambient temperature exceeds 40°C, the rated current must be derated according to the temperature coefficient.
  3. Accessory Matching: Pay attention to matching the accessory with the circuit breaker model and pole number when selection, such as the voltage level of the shunt release.
  4. Installation Specifications: Ensure installation in a switchgear that meets requirements, with proper ventilation and heat dissipation maintained.
  5. Manutenção regular: Periodically inspect the circuit breaker appearance, operating mechanism and trip unit performance to ensure reliable operation.
  6. Replacement Suggestion: For new projects, it is recommended to directly select 3VA/3VM/3VC series alternative products to achieve better performance and a longer service life.

Anterior:

Próximo:

Deixe uma resposta