TENSE DGK-04Relé de controle F

TENSE DGK-04F Digital Adjustable 3-Phase Over&Under Voltage & Phase Sequence Control Relay Model Positioning & Core Functions TENSE DGK-04F is a digitally adjustable 3-phase over&under voltage+phase sequence control relay manufactured by TENSE Electronic (Peru). It belongs to the DGK series protection and control products, designed specifically for industrial three-phase equipment. It monitors voltage anomalies (overvoltage/undervoltage) ...

  • Detalhes do produto

TENSE DGK-04F Digital Adjustable 3-Phase Over&Under Voltage & Phase Sequence Control Relay

  1. Posicionamento do modelo & Funções principais

TENSE DGK-04F is a digitally adjustable 3-phase over&under voltage+phase sequence control relay manufactured by TENSE Electronic (Peru). It belongs to the DGK series protection and control products, designed specifically for industrial three-phase equipment. It monitors voltage anomalies (overvoltage/undervoltage) and phase sequence errors simultaneously to prevent equipment damage caused by grid fluctuations or wiring mistakes.

Regras de codificação de modelo (DGK-XXX)

SeçãoSignificadoExemplo
DGKFixed prefix (digital adjustable 3-phase voltage control relay)DGK
4Código de função (04=over&under voltage + phase sequence control, 03=over&under voltage control, 01=single-phase control)4
FVersion indicator (F=digital display/enhanced type, no suffix=basic type, PF=with phase failure protection)F
  1. Especificações Técnicas Principais
Categoria de parâmetroEspecificações detalhadas
Funções de proteção3-phase overvoltage protection, 3-phase undervoltage protection, phase sequence error protection, non-phase-sequence control (switchable)
Voltage Setting RangeSobretensão: 400V – 460V AC (ajustável); Subtensão: 230V – 360V AC (ajustável)
Tempo de respostaFault waiting time: 0.1s – 10s (ajustável), fast response to grid anomalies
Avaliação de contato5CA/250V CA (carga resistiva), 1 NÃO + 1 NC contact configuration
Tensão de alimentação3-phase AC 380V (no neutral wire required), wide voltage design for global power grids
Frequência operacional50/60Hz (auto-adaptive)
Temperatura operacional-10°C to +55°C (industrial standard wide temperature range)
MontagemMontagem em trilho DIN (standard 35mm) or front panel mounting, flexible for control cabinet layout
DimensõesDesign compacto, economiza espaço no armário
CertificaçõesCE, UL, CSA (compliant with international safety standards)
Grau de ProteçãoIP20 (deve ser instalado no gabinete de controle)
Consumo de energiaBaixo consumo de energia, energy-saving and eco-friendly
  1. Principais recursos & Vantagens
  2. Three-in-one protection: Integra sobretensão, subtensão, and phase sequence protection; one device solves multiple grid risks.
  3. Digital precise adjustment: Higher accuracy (±1V) than analog relays, with more intuitive settings.
  4. Non-phase-sequence control mode: Switchable via DIP switch, suitable for special applications without phase sequence protection.
  5. No neutral wire required: Direct 3-phase power supply, simplifies wiring and reduces installation cost.
  6. Stable wide-temperature operation: Adapts to harsh industrial environments and maintains reliable performance at high/low temperatures.
  7. Dual mounting methods: DIN rail or panel mounting to meet different cabinet design requirements.
  8. Clear fault indication: LED indicators intuitively show operating status and fault types for quick troubleshooting.
  9. DGK Series Full Model Comparison
ModeloFunções de proteçãoVoltage Setting RangeRecursos especiaisAplicativo
DGK-01Single-phase over&under voltage protectionSobretensão: 230V–260V; Subtensão:170V–220VSingle-phase dedicated, tamanho menorLighting systems, small single-phase equipment
DGK-033-phase over&under voltage protectionSobretensão:400V–460V; Subtensão:230V–360VTipo básico, cost-optimizedGeneral 3-phase motors, bombas
DGK-043-phase over&under voltage + phase sequence protectionSobretensão:400V–460V; Subtensão:230V–360VNo digital display, funções básicasGeneral industrial equipment, budget-limited projects
DGK-04F3-phase over&under voltage + phase sequence protectionSobretensão:400V–460V; Subtensão:230V–360VDigital display, adjustable parametersEquipamento de precisão, key production lines, automation systems
DGK-04PF3-phase over&under voltage + sequência de fase + proteção contra falha de faseSobretensão:400V–460V; Subtensão:230V–360VFull-function protection, including phase loss detectionEquipamento crítico, continuous production systems
  1. Cenários típicos de aplicação
  2. Industrial motor protection: 3-phase asynchronous motors, compressores, bombas; prevents winding burnout from abnormal voltage or mechanical damage from reverse rotation due to phase sequence error.
  3. Linhas de produção automatizadas: Sistemas de controle PLC, estações de trabalho robóticas, CNC machines; ensures stable operation of precision equipment and avoids production interruptions caused by grid fluctuations.
  4. Construindo sistemas elétricos: Central air conditioning, elevadores, pump rooms; protects key building equipment and improves power supply reliability.
  5. Energia renovável: PV inverters, wind power equipment; adapts to unstable new energy output and protects grid-connected devices.
  6. Petrochemical industry: Auxiliary equipment outside hazardous areas; wide-temperature design adapts to high-temperature refinery environments.
  7. Mining machinery: Crushers, transportadores; withstands harsh grid conditions and prevents frequent equipment failures.
  8. Alternative Products & Order Codes from Other Brands

6.1 Alternativas de marcas internacionais (Equivalent Function)

TENSE ModelMarcaModelo AlternativoCódigo do pedidoPrincipais pontos de correspondência
DGK-04FSiemens3UG4632-1AW303UG4632-1AW303-phase over&under voltage + phase sequence protection, digital display, adjustable parameters
DGK-04FSchneiderRM22TG20RM22TG203-phase voltage monitoring, over&under voltage + phase sequence protection, 5A contacts
DGK-04FABBCM-PVS.41S1SVR730820R12003-phase over&under voltage + sequência de fase + proteção contra perda de fase, full grid monitoring
DGK-04FOmronK8DS-PH3K8DS-PH3Digital 3-phase voltage & phase sequence relay, adjustable response time

6.2 Chinese Brand Alternatives (Econômico)

TENSE ModelMarcaModelo AlternativoCódigo do pedidoPrincipais pontos de correspondência
DGK-04FCHINTNJD-8NJD-83-phase over&under voltage + phase sequence protection, affordable, suitable for domestic grids
DGK-04FDeliciosoCDJS1CDJS1Digital display, comprehensive 3-phase voltage & phase sequence protection, 5A contact rating
DGK-04FInterruptor ChangshuCK3-32CK3-32Triple protection: over&under voltage + sequência de fase + perda de fase, industrial-grade reliability
  1. Key Points for Selection & Substituição

7.1 Core Matching Dimensions (Must Check for Replacement)

DimensãoMatching StandardNotas
Funções de proteçãoFully consistent (sobretensão + subtensão + sequência de fase)Avoid insufficient protection due to missing functions
Avaliação de contato≥5A/250V ACEnsure it can drive control circuit loads
Tensão de alimentação3-phase 380V (no neutral wire)Match original system power to avoid complex wiring
Tempo de resposta0.1–10s adjustableShort-delay models required for fast-response equipment
MontagemMontagem em trilho DINMaintain consistent control cabinet layout

7.2 Replacement Implementation Recommendations

  1. Parameter migration: Record overvoltage/undervoltage thresholds, response time and other parameters of the original DGK-04F, and set identical parameters on the new device after replacement.
  2. Wiring verification: 3-phase power wiring must be consistent with the original system; phase sequence errors cause false protection.
  3. Function test: After replacement, perform simulated overvoltage, undervoltage and phase sequence error tests to verify normal protection functions.
  4. Redundant configuration: Paired configuration is recommended for critical equipment to improve system reliability.
  5. Guia de seleção rápida
AplicativoPreferred ModelAlternative SuggestionBudget Reference
Key production lines / equipamento de precisãoDGK-04PF (full-function protection)Siemens 3UG4632-1AW30Medium–high budget
General industrial motors / bombasDGK-04FSchneider RM22TG20Medium budget
Cost-sensitive projects / civil buildingsDGK-04CHINT NJD-8 / Delixi CDJS1Low budget

Complete Manual of TENSE Relay Product Series Codes

  1. Voltage Control Relays (Core Protection Series)

1.1 Classic Analog Type (GK Series)

ModeloDescrição da funçãoAplicativo
GKE-40Single-phase over&under voltage control relayResidential/commercial single-phase equipment protection
GKV-12Single-phase over&under voltage control relaySmall single-phase motors, pump control
GKV-12FSingle-phase over&under voltage control relay (enhanced)Precision single-phase equipment requiring digital display
GK-033-phase over&under voltage control relayBasic voltage protection for 3-phase motors
GK-043-phase over&under voltage + phase sequence control relay3-phase equipment protection against wiring errors + voltage anomalies
GK-04F3-phase over&under voltage + phase sequence control relay (digital display)3-phase equipment requiring status indication
GK-04S3-phase over&under voltage + phase sequence control relay (special version)Custom for specific industrial scenarios
GKM-11Single-phase over&under voltage control relay (high sensitivity)Voltage fluctuation-sensitive equipment
GKM-02Single-phase over&under voltage control relay (compactar)Installation in narrow control cabinets
GKM-02FSingle-phase over&under voltage control relay (compactar + display)Equipamento pequeno + monitoramento de status
GKT-033-phase over&under voltage control relay (ampla gama)Special voltage-class 3-phase systems
GKT-03F3-phase over&under voltage control relay (ampla gama + display)Ampla faixa de tensão + status display

1.2 Digital Adjustable Type (DGK Series)

ModeloDescrição da funçãoAplicativo
DGK-01Digital adjustable single-phase over&under voltage control relayPrecision single-phase equipment with precise parameter adjustment
DGK-03Digital adjustable 3-phase over&under voltage control relay3-phase motors requiring accurate voltage protection
DGK-04Digital adjustable 3-phase over&under voltage + phase sequence control relayComprehensive protection for standard 3-phase equipment
DGK-04FDigital adjustable 3-phase over&under voltage + phase sequence control relay (digital display)Industrial automation production lines requiring status monitoring
DGK-04PFDigital adjustable 3-phase over&under voltage + sequência de fase + phase failure protection relay (full-function)Critical equipment requiring complete grid monitoring
  1. Current Protection Relays (Sobrecarga / Proteção contra perda de fase)
ModeloDescrição da funçãoAplicativo
TRM-100Digital 3-phase overload protection relaySobrecarga, locked rotor, phase loss protection for 3-phase motors
TRM-200Digital 3-phase overload protection relay (extended)Large 3-phase motors with multi-parameter adjustment
DR-01Single-phase current protection relayOverload protection for single-phase motors
DR-023-phase current protection relayBasic current protection for small 3-phase motors
  1. Relés de tempo (Delay Control Series)

3.1 Digital Programmable Type

ModeloDescrição da funçãoTime Range
TTR-10Digital programmable multi-function time relay0.01s – 9999h, multiple modes
TTR-20Digital programmable time relay (dual output)Complex control logic requiring two delay groups

3.2 Analog Timing Type

ModeloDescrição da funçãoDelay Range
TT-01Single delay time relay0.1s – 10s
TT-02Dual delay time relay0.1s – 60s
TT-03Long delay time relay1s – 10min
  1. Temperature Control Relays (Temperature Monitoring & Proteção)
ModeloDescrição da funçãoFaixa de temperatura
DT-96YDigital temperature control relay (96mm panel)-50°C ~ +150°C
DT-72YDigital temperature control relay (72mm panel)-50°C ~ +150°C
DT-48YDigital temperature control relay (48mm panel)-50°C ~ +150°C
DT-36YDigital temperature control relay (36mm panel)-50°C ~ +150°C
DT-72EMDigital temperature control relay (enhanced, with communication)-50°C ~ +200°C, for remote monitoring
DT-YUniversal digital temperature control relay-50°C ~ +150°C, compactar
DT-96E/DT-72E/DT-48E/DT-36EDigital temperature control relay (extended functions)-50°C ~ +200°C, multiple output modes
DT-322Dual-channel temperature control relaySimultaneous monitoring of two temperature points
DTZ-96/DTZ-72/DTZ-48Intelligent temperature control relay (with PID regulation)Precision temperature control systems (fornos, furnaces)
TK-1/TK-1.5/TK-2/TK-2.5/TK-3/TK-4/TK-5Relé de sobrecarga térmicaMotor winding temperature protection, used with contactors
PT-1/PT-3Temperature probe dedicated relayTemperature sensor signal conversion & controlar
  1. Submersible Pump Control Relays (Special Control Series)
ModeloDescrição da funçãoMétodo de controle
TDK-96Intelligent 3-phase submersible pump control relay (2.9″ graphic LCD)Electrode-less well control, 1A–250A current range
TDK-023-phase submersible pump control relay (basic)Ordinary well submersible pumps, basic protection
MDK-02Single-phase submersible pump control relaySmall single-phase submersible pumps, household/farm use
TDK-973-phase submersible pump control relay (enhanced)Large submersible pumps with fault recording
  1. Power Factor Controllers (Reactive Power Compensation Series)

6.1 Three-Phase Series (RGT Series)

ModeloDescrição da funçãoCompensation Stages
RGT-083-phase power factor controller8-stage compensation
RGT-123-phase power factor controller12-stage compensation, graphic LCD
RGT-12M3-phase power factor controller (memory)12-stage, power-off memory
RGT-12H3-phase power factor controller (with communication)12-stage, Modbus communication
RGT-12TH3-phase power factor controller (thyristor trigger)12-stage, contactless switching
RGT-183-phase power factor controller18-stage compensation
RGT-18H3-phase power factor controller (with communication)18-stage, Modbus communication
RGT-18TH3-phase power factor controller (thyristor trigger + comunicação)18-stage, contactless + comunicação
RGT-24H3-phase power factor controller (with communication)24-stage compensation, Modbus communication
RGT-MT183-phase digital power factor controller (advanced)18-stage, multi-parameter adjustable
RGT-12SVC/RGT-18SVC/RGT-MT18 SVC3-phase static var compensator controllerDynamic reactive power compensation, resposta rápida

6.2 Single-Phase Series (RGM Series)

ModeloDescrição da funçãoCompensation Stages
RGM-07ESingle-phase power factor controller7-stage compensation
RGM-12ESingle-phase power factor controller12-stage compensation
RGM-12ERSingle-phase power factor controller (with communication)12-stage, Modbus communication
RGM-12SSingle-phase power factor controller (simple)12-stage, funções básicas
  1. Special Function Relays (Customized Applications)
ModeloDescrição da funçãoAplicativo
DGR-01Earth fault protection relayEquipment earth fault detection, electric shock prevention
DGT-02Digital earth fault protection relayPrecision equipment requiring earth current digital display
TKR-01Star-delta starting relayStar-delta reduced-voltage starting control for 3-phase motors
TSR-02Auto-transformer starting relayAuto reduced-voltage starting control for large motors
PSR-03Phase sequence protection relay (independent)3-phase equipment requiring only phase sequence protection
  1. Model Coding Rule Analysis

8.1 Voltage Control Relays (GK/DGK Series)

Segmento de códigoSignificadoExemplo
GFixed prefix (voltage control)GK-04F
KFunction type (K=control)DGK-04PF
XFase / características (E=single-phase, 03=3-phase over&under voltage, 04=3-phase over&under voltage + sequência de fase)GKE-40
Suffix FEnhanced type (digital display / extended functions)GK-04F
Prefix DDigital adjustable typeDGK-01
Suffix PFWith phase failure protectionDGK-04PF

8.2 Power Factor Controllers (RGT/RGM Series)

Segmento de códigoSignificadoExemplo
RGFixed prefix (reactive power control)RGT-12
T/MFase (T=3-phase, M=single-phase)RGM-12E
NúmeroCompensation stages (08=8, 12=12, 18=18)RGT-18
Suffix HWith communication functionRGT-12H
Suffix THThyristor trigger outputRGT-12TH
Suffix SVCStatic var compensationRGT-12SVC
  1. Series Quick Reference Guide
Product CategorySérie PrincipalRepresentative ModelPrincipais Funções
Voltage ProtectionGK/DGKDGK-04FSobre&under voltage + phase sequence protection, digital adjustable
Current ProtectionTRM/DRTRM-100Sobrecarga + perda de fase + locked rotor protection
Time ControlTTR/TTTTR-10Multi-function programmable delay
Controle de temperaturaDT/DTZDT-96YDigital temperature monitoring & controlar
Pump ControlTDK/MDKTDK-96Comprehensive submersible pump protection & controlar
Reactive Power CompensationRGT/RGMRGT-12HPower factor optimization, economia de energia

Complete Analysis of TENSE ERV Series Time Relays (Including Models, Especificações, Aplicativos & Alternativas)

  1. Series Positioning & Funções principais

TENSE ERV series is the economy time relay product line of TENSE Electronic (Peru), focusing on delay control and sequential logic in industrial automation. It covers basic on-delay, multi-function cycle, star-delta starting and other special applications. With compact design, wide voltage adaptability and high cost performance as core advantages, it is widely used in motor control, production line automation, building electrical and other fields.

Core Features of the Series

  1. Projeto modular: Standard 22.5mm DIN rail mounting, economiza espaço no armário.
  2. Wide voltage supply: 150–260V AC / 24V AC/DC auto-adaptive, suitable for global power grids.
  3. Alta confiabilidade: IP40 protective shell, V-0 flame retardant material, adapts to harsh industrial environments.
  4. Configuração flexível: Knob / DIP / button adjustment methods to meet different accuracy requirements.
  5. Proteção abrangente: Sobrecarga, curto-circuito, overvoltage protection to extend service life.
  6. Regras de codificação de modelo (ERV-XX[D/F/M/YU/STER])
Segmento de códigoSignificadoExemplo
ERVFixed prefix (economy time relay)ERV-12, ERV-09D
XXBasic time range (03=0.1–3min, 09=0.1–9min, 12=0.1–12sec, 30=0.1–30min, 60=0.1–60min, 08=0.1sec–100h)ERV-30, ERV-08
DMulti-function type (includes on-delay, off-delay, cycle, etc.)ERV-03D, ERV-60D
FFlashing type (dual time setting: run time + stop time)ERV-09F
MMemory type (retains settings after power failure)ERV-08M
YU/STERStar-delta dedicated (built-in Y-Δ conversion logic, fixed short delay)ERV-YU, ERV-STER
  1. ERV Series Complete Model List (By Function)

3.1 Basic On-Delay Type (No Suffix D)

ModeloDelay RangeConfiguração de contatoAplicativo
ERV-120.1s – 12s (ajustável)1 NÃO + 1 NCShort delay control (válvulas solenóides, cylinder fast action)
ERV-030.1s – 3min (ajustável)1 NÃO + 1 NCMedium delay (fãs, pump start delay)
ERV-090.1s – 9min (ajustável)1 NÃO + 1 NCLong delay (aquecedores, lighting system delay)
ERV-300.1s – 30min (ajustável)1 NÃO + 1 NCExtra-long delay (equipment preheating, cooling delay)
ERV-600.1s – 60min (ajustável)1 NÃO + 1 NCUltra-long delay (intermittent production, timed shutdown)
ERV-080.1s – 100h (ajustável)1 NÃO + 1 NCVery long delay (periodic maintenance reminder, backup equipment switching)

3.2 Multi-Function Delay Type (Suffix D)

ModeloDelay RangeModesFunções EspeciaisAplicativo
ERV-03D0.1s – 3min (ajustável)5+Atraso, off-delay, single pulse, interval pulseEquipamentos de automação pequenos, multi-logic control
ERV-09D0.1s – 9min (ajustável)5+Cycle control (run-stop alternating), flashing modeWarning lights, intermittent pumps, advertising light boxes
ERV-30D0.1s – 30min (ajustável)5+Extended delay range for medium-long cycle controlProduction line segment control, material conveying delay
ERV-60D0.1s – 60min (ajustável)5+Dual delay setting for complex sequential logicLarge equipment startup process, multi-level safety interlock

3.3 Special Function Type (Special Suffix)

ModeloFunction TypeParâmetros principaisAplicativo
ERV-09FFlashing relayCorrer:0.1sec–99min, Parar:0.1sec–99minWarning lights, alarms, signal indication
ERV-08MMemory delay relay0.1sec–100h, power-off parameter retentionUnattended equipment, emergency systems
ERV-YUStar-delta starting relayY delay:0.1–30sec, Y-Δ switch:10–500msec (ajustável)Star-delta reduced-voltage starting for 3-phase asynchronous motors
ERV-STERStar-delta starting relay (enhanced)Y delay:0.1–30sec, Y-Δ switch:15msec (fixo), LED statusPrecision motor control (compressores, bombas)
ERV-09DDDual-output delay relayTwo independent delay controls, 0.1–9minSequential control of two independent devices
  1. Core Technical Specifications Comparison (Full Series)
Categoria de parâmetroTipo Básico (ERV-XX)Multi-Function Type (ERV-XXD)Star-Delta Dedicated (ERV-YU/STER)Flashing Type (ERV-09F)
Avaliação de contato5CA/250V CA (resistive)5CA/250V CA (resistive)5CA/250V CA (resistive)5CA/250V CA (resistive)
Configuração de contato1 NÃO + 1 NC1 NÃO + 1 NC2 NÃO + 1 NC (star-delta dedicated)1 NÃO + 1 NC
Tensão de alimentação150–260V AC/24V AC/DC150–260V AC/24V AC/DC150–260V AC/24V AC/DC150–260V AC/24V AC/DC
Frequência operacional50/60Hz (auto-adaptive)50/60Hz (auto-adaptive)50/60Hz (auto-adaptive)50/60Hz (auto-adaptive)
Temperatura operacional-10°C to +55°C-10°C to +55°C-10°C to +55°C-10°C to +55°C
Consumo de energia<4VA<4VA<4VA<4VA
MontagemTrilho DIN (35milímetros)Trilho DIN (35milímetros)Trilho DIN (35milímetros)Trilho DIN (35milímetros)
Dimensões22.5×67×76mm22.5×67×76mm22.5×67×76mm22.5×67×76mm
CertificaçõesCE, UL, CSACE, UL, CSACE, UL, CSACE, UL, CSA
  1. Cenários típicos de aplicação
  2. Controle Motor

ERV-YU/STER: Star-delta starting for 3-phase motors (7.5kW–90kW)

ERV-30D: Motor overload protection delay to prevent frequent starting

ERV-03: Delayed start of motor auxiliary equipment (fãs, bombas de óleo)

  1. Linhas de produção automatizadas

ERV-12: Short-cycle action control (cylinder extension, material pushing)

ERV-60D: Inter-process delay to ensure material in place and temperature compliance

ERV-08: Long-cycle equipment maintenance reminders (filter replacement, lubrificação)

  1. Building Electrical Systems

ERV-09F: Emergency lighting flashing control, exit indication

ERV-30: Delayed start of air conditioning and ventilation to balance grid load

ERV-60: Timed control of public area lighting for energy saving

  1. Special Industrial Applications

ERV-09DD: Dual-station switching control for welding equipment

ERV-08M: Delayed closing of cold storage doors to prevent cold air loss

ERV-60D: Chemical dosing and backwash sequence control in water treatment systems

  1. Alternative Products & Order Codes from Other Brands

6.1 Alternativas de marcas internacionais (Equivalent Function)

TENSE ModelMarcaModelo AlternativoCódigo do pedidoPrincipais pontos de correspondência
ERV-03DSiemens3RP1505-1BQ303RP1505-1BQ300.1–3min delay, multifuncional, Trilho DIN
ERV-60DSchneiderRE17R12MWRE17R12MW0.1–60min delay, multiple modes, ampla tensão
ERV-YUABBCT-MPS.211SVR730820R1200Início estrela-triângulo, 0.1–30sec delay, dual output
ERV-09FOmronH3CR-F8H3CR-F8Flashing control, dual time setting, 5A contacts

6.2 Chinese Brand Alternatives (Econômico)

TENSE ModelMarcaModelo AlternativoCódigo do pedidoPrincipais pontos de correspondência
ERV-03DCHINTJSZ3A-AJSZ3A-AAtraso, 0.1–3min, 1 NÃO + 1 NC
ERV-60DDeliciosoCDJS1-60CDJS1-60Multi-function delay, 0.1–60min, ampla tensão
ERV-YUInterruptor ChangshuCK3-YDCK3-YDInício estrela-triângulo, 0.1–30sec, Indicação LED
ERV-08MTianshui 213JSZ8-08MJSZ8-08MMemory delay, 0.1sec–100h, retenção de desligamento
  1. Key Points for Selection & Substituição

7.1 Core Matching Dimensions (Must Check for Replacement)

DimensãoMatching StandardNotas
Delay RangeCovers original equipment requirements (por exemplo, 0.1–30sec → ERV-YU)Avoid insufficient or redundant time range
Configuração de contatoSame quantity & tipo (e.g.,1 NO+1 NC →1 NO+1 NC)Star-delta applications require 2 NÃO+1NC
Tensão de alimentaçãoAdapt to original system (150–260V AC/24V DC)Avoid damage due to voltage mismatch
MontagemMontagem em trilho DIN (22.5mm standard size)Maintain consistent cabinet layout
Function ModeSame core function (flashing→flashing, star-delta→star-delta)Multi-function type can replace basic type

7.2 Recomendações de seleção

  1. Basic delay control: Prioritize ERV-XX series (ERV-12 for 0.1–12sec, ERV-03 for 0.1–3min)
  2. Complex sequential control: Choose ERV-XXD multi-function type (supports multiple delay modes)
  3. Motor starting applications: Star-delta starting must use ERV-YU/STER dedicated models for accurate switching timing
  4. Long-cycle control: Choose ERV-08/08M (0.1sec–100h) for unattended scenarios
  5. Budget-sensitive projects: Chinese brand alternatives (CHINT, Delicioso) reduce cost by 30%–50%
  6. Guia de seleção rápida
AplicativoPreferred TENSE ModelAlternative SuggestionBudget Reference
3-phase motor star-delta startingERV-YU/STERABB CT-MPS.21 / CHINT CK3-YDMedium–low budget
Short-cycle control (<1min)ERV-03/ERV-03DSiemens 3RP1505 / Delixi CDJS1-03Low budget
Long-cycle control (>1min)ERV-30/ERV-60DSchneider RE17R12MW / CHINT JSZ3CMedium budget
Flashing / alarm controlERV-09FOmron H3CR-F8 / CHINT JSZ3FLow budget
Memory controlERV-08MTianshui 213 JSZ8-08MMedium budget

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado