ALPHA6000M-S2R75GB; RSM is a custom suffix (not defined in standard factory manuals. It usually stands for built-in braking resistor, fitted keypad, special firmware version or RoHS custom version. Confirm the definition of RSM with your supplier before ordering.)
✅ Model Code Breakdown
ALPHA6000M: ALPHA6000M series, mini open-loop current vector inverter
S2: Single-phase 220V input (200~240V AC)
R75: Matched motor power 0.75kW
G: General-purpose load (cuplu constant)
B: Unitate de frânare încorporată (supports external braking resistor)
RSM: Custom suffix (non-standard factory code)
✅ Key Electrical Specifications
Intrare nominală: AC monofazat 220V, 50/60Hz
Ieșire nominală: 3-phase 0~220V
Curent nominal de ieșire: 4.0O
Control modes: control V/F, Sensorless Open-loop Vector, V/F separation
Starting torque: 180% rated torque at 0.5Hz
Speed regulation range: 1:200 in vector mode; 1:100 in V/F mode
Comunicare: Built-in RS485, Modbus-RTU
Max output frequency: 0~650Hz
Capacitate de suprasarcină: 150% for 60s, 200% for 3s
Protecţie: Supracurent, supratensiune, subtensiune, supraîncălzire, suprasarcina, pierdere de fază, defecțiune la pământ, etc.
✅ Product Features
Compact body, small footprint, suitable for cabinets with limited installation space
AVR automatic voltage regulation, stable operation with ±20% grid voltage fluctuation
Supports motor parameter auto-tuning, strong low-frequency torque
Multiple programmable DI/DO, analog AI/AO, cu mai multe viteze, PID, counting and other functions
Independent air channel for reliable heat dissipation. Widely used for assembly lines, fani, pompe de apa, transportoare, small machine tools and other constant-torque applications
✅ Typical Applications
Transportoare mici, utilaje de ambalare, fani & pompe de apa, linii de producție, small extruders, utilaje pentru prelucrarea lemnului, food processing machinery
✅ Replacement & Compatibilitate
Same-series alternative: ALPHA6000E-S2R75GB (6000E is standard version; 6000M is mini version. Pinout and dimensions differ, not direct plug-and-play)
Domestic equivalent models: Inovance MD200, Invt GD10, Delta VFD-M single-phase 220V 0.75kW models
Full Technical Package for ALPHA6000M-S2R75GBRSM
- Main Circuit Terminals (S2R75GB, single-phase 220V)
| Terminal | Funcţie | Descriere |
| L, N | Single-phase 220V input | AC200~240V power supply |
| +, PB | Braking resistor terminals | Unitate de frânare încorporată. Connect resistor between + and PB. Do NOT connect to DC negative (-) |
| U, V, W | 3-ieșire de fază | Connect to 3-phase 220V asynchronous motor. Never connect mains power |
| PE | Pământ protector | Inverter and motor frame must be grounded together |
Critical warning: Never connect L/N to U/V/W, this will destroy the inverter immediately; PB and + can only be connected with braking resistor, short-circuit is forbidden.
- Terminale ale circuitului de control (S2R4GB ~ S2R75GB)
| Terminal | Funcţie | Caietul de sarcini |
| X1~X6 | Multi-function DI inputs | Contact uscat, common terminal COM. Factory default: X1 forward run, X2 reverse run |
| COM | DI common terminal | 24V reference ground |
| 24V | External 24V DC supply | Max 100mA. Do not short to COM directly |
| 10V | +10V analog reference | Max 20mA, for potentiometer |
| GND | Analog ground | Reference for AI/AO |
| AI1 | Intrare analogică 1 | 0~10V / 4~20mA (selected by DIP switch), 0~20mA, 250 |
| AI2 | Intrare analogică 2 | -10V~+10V voltage input |
| AO1, AO2 | Ieșire analogică | Configurable 0~10V or 4~20mA, selected by SW2 DIP switch |
| DO | Open-collector output | Opto-isolated, max 50mA, 0~50kHz pulse output |
| FATA, TB, TC | Ieșire releu | TA-TB NC; TA-TC NO; 250VAC/2A |
| 485+, 485- | Comunicare RS485 | Modbus-RTU, for PLC / HMI connection |
| PLC | DI source selection terminal | Factory default: PLC shorted with 24V for NPN mode; disconnect to use PNP |
Common Wiring Schemes
- Potentiometer speed + terminal control: Potentiometer to 10V, AI1, GND; short X1-COM = forward run
- 485 comunicare: 485+ to A, 485to B; add termination resistor on remote side if needed
- Relay fault signal: TA-TC to PLC fault input
- Factory Reset Procedure (ALPHA6000M / 6000E compatible)
- Porniți, press PRG to enter parameter menu
- Locate P0.02 (parameter initialization)
- Setting options:
0: Nicio acțiune
1: Clear fault records
2: Restore factory defaults (recomandat)
- Confirma, wait for auto-reset. Power cycle to take effect
Frequently used basic parameters:
P0.01: Control mode 0=V/F, 2=open-loop vector (vector recommended)
P0.07: Run command source 0=keypad, 1=terminals, 2=communication
P0.03: Frequency reference source 0=keypad, 2=AI1, 8=multi-speed, 10=PID
P0.10: Max output frequency, implicit 50 Hz, up to 650Hz
⚠️ Resistance below 100Ω will damage the built-in braking transistor. Mount resistor away from other components with sufficient clearance; resistor housing must be grounded.
Cablaj: Connect resistor two wires directly between + and PB, not the “-” Terminal.
- Equivalent Replacement List (single-phase 220V 0.75kW mini vector, built-in braking unit preferred)
Nota: ALPHA6000M is mini type. Pinout and mounting holes differ from 6000E standard version, cannot be swapped directly
Alternative interne
- Inovance MD200S0.75B (single-phase 220V, mini, built-in braking)
- Invt GD10-0R75-S2-B (GD10 mini series)
- Delta VFD007M21A (VFD-M classic small model)
- Sifang E310-2S0007
- Win-V63 0.75kW 220V single-phase
Note de înlocuire
Priority check items: unitate de frânare încorporată, DI/DO quantity, AO 4-20mA support, Modbus RTU
Original unit: intrare monofazată, 3-phase 220V output. Replacement motor must be rated 220V 3-phase, cannot drive 380V motor directly
For easy parameter migration: ALPHA6000E-S2R75GB from same brand, but larger size and different mounting holes
- Fault Code Quick Reference (6000M)
| Cod de eroare | Descriere | Depanare |
| OC | Supracurent | Scurtcircuit motor, defect la pământ, rotor blocat, too short acceleration time |
| OV | Supratensiune | Fast deceleration, missing braking resistor, high grid voltage |
| LV | Subtensiune | Input phase loss, low supply voltage, poor contact of contactor |
| OH | Supraîncălzi | Blocked air channel, failed fan, temperatura ambientala ridicata |
| OL | Suprasarcina motorului | Overloaded machine, incorrect motor auto-tuning |
| CE | Communication error | Reversed 485 cablare, termination resistor, mismatched address / baud rate |
- Motor Auto-Tuning (Mandatory for Vector Mode)
- Set P0.01=2 (open-loop vector)
- Enter motor nameplate data: P2.00 rated power, P2.01 rated current, P2.02 rated frequency, P2.03 rated speed
- P2.04=1 (static auto-tuning, motorul staționar); P2.04=2 rotating auto-tuning (motor runs no-load, higher torque accuracy)
- Confirm and start; auto-tuning finishes automatically
ALPHA6000M Multi-speed + PID Constant Pressure Water Supply Parameter Set
For ALPHA6000M‑S2R75GB (0.75kW single-phase 220V)
Nota: Do not activate both functions at once. PID is for constant pressure water / air supply; multi-speed is for assembly lines, packaging machines and multi-position fixed speed switching.
Schema A: Control cu mai multe viteze (DI speed selection, terminal start/stop)
Logica de control
Command source: Terminal run
Frequency source: Cu mai multe viteze
DI assignment: X1 forward run, X2 reverse run, X3/X4/X5 as speed selectors (3-binar binar, până la 8 viteze)
COM is DI common terminal, NPN mode (factory PLC shorted with 24V)
Parameter List
| Param No. | Nume | Setare | Observații |
| P0.01 | Modul de control | 2 | Open-loop vector (recomandat); 0=V/F |
| P0.07 | Run command source | 1 | Terminal control (X1 forward / X2 reverse) |
| P0.03 | Frequency reference source | 8 | Multi-speed reference |
| P0.10 | Max frequency | 50 | Follow motor nameplate, max 650Hz |
| P0.11 | Min frequency | 0 | Adjust as required |
| P1.00 | Acc time 1 | 5 | Unitate: s |
| P1.01 | Dec time 1 | 5 | Extend for frequent stopping |
| P3.00 | X1 function | 0 | Forward run |
| P3.01 | X2 function | 1 | Reverse run |
| P3.02 | X3 function | 12 | Speed selector S1 |
| P3.03 | X4 function | 13 | Speed selector S2 |
| P3.04 | X5 function | 14 | Speed selector S3 |
| P4.00 | Cu mai multe viteze 0 | 10 | Viteză 0 (all S1S2S3 OFF) |
| P4.01 | Cu mai multe viteze 1 | 15 | S1 ON |
| P4.02 | Cu mai multe viteze 2 | 20 | S2 ON |
| P4.03 | Cu mai multe viteze 3 | 25 | S1+S2 ON |
| P4.04 | Cu mai multe viteze 4 | 30 | S3 ON |
| P4.05 | Cu mai multe viteze 5 | 35 | S1+S3 ON |
| P4.06 | Cu mai multe viteze 6 | 40 | S2+S3 ON |
| P4.07 | Cu mai multe viteze 7 | 50 | S1+S2+S3 ON |
Wiring Tips
No pressure / speed sensor required; only DI switch signals
If only 4 speeds are needed, use X3 and X4 only; X5 can be assigned to fault reset or other functions
Schema B: PID Constant Pressure Water Supply (Closed-loop, 4-20mA pressure transmitter)
For small pump pressure stabilization. 4~20mA transmitter to AI1; 4mA = lower pressure, 20mA = full scale pressure
Output of this inverter is 3-phase 220V. Pump motor must be 3-phase 220V type, not 380V pump motor
Logica de control
Command source: Terminal start (X1 forward run)
Frequency source: PID output
AI1: 4~20mA pressure feedback
PID setpoint: Keypad setting (or AI2 potentiometer setpoint)
Parameter List
| Param No. | Nume | Setare | Observații |
| P0.01 | Modul de control | 0 | V/F preferred for pumps |
| P0.07 | Run command source | 1 | Terminal start X1 forward |
| P0.03 | Frequency reference source | 10 | PID reference |
| P0.10 | Max frequency | 50 | Pump rated frequency |
| P0.11 | Min frequency | 20 | Prevent dry running at low speed |
| P1.00 | Acc time | 10 | Avoid water hammer |
| P1.01 | Dec time | 15 | Pumps must not stop rapidly |
| P5.00 | PID enable | 1 | Enable PID |
| P5.01 | PID setpoint source | 0 | Keypad setpoint; 1=AI2 external setpoint |
| P5.02 | PID feedback source | 0 | AI1 feedback |
| P5.03 | PID proportional gain Kp | 30 | Initial value; reduce if oscillating |
| P5.04 | PID integral time Ti | 2 | Unitate: s; increase if pressure fluctuates |
| P5.05 | PID derivative time Td | 0 | Derivative unused for water supply |
| P5.06 | PID deviation limit | 5 | Fast adjustment over this deviation |
| P5.07 | PID output upper limit | 100 | Corresponds to max frequency |
| P5.08 | PID output lower limit | 0 | |
| P5.09 | PID sleep function | 0 | 0=disable; 1=enable sleep at low flow |
| P6.00 | AI1 type selection | 1 | 1=4~20mA; 0=0~10V |
| P6.01 | AI1 min value | 0 | Pressure at 4mA (MPa) |
| P6.02 | AI1 max value | 1 | Pressure at 20mA (MPa), adjust as per transmitter |
Cablaj
Pressure transmitter: Powered by inverter 24V, signal+ → AI1, signal→ GND
Set AI1 DIP switch to current mode (4-20mA)
Short X1-COM to start; open to stop
PID Tuning Sequence (Important)
- Disable PID first (P5.00=0), run pump manually to confirm rotation direction
- Confirm transmitter range: de ex. 0~1MPa, P6.01=0, P6.02=1.0
- P5.00=1 to enable PID, set target pressure on keypad e.g. 0.4MPa
- Depanare:
Pressure oscillates: Reduce Kp (de ex. la 15), increase Ti
Pressure rises slowly: Increase Kp, reduce Ti
Severe overshoot: Reduce Kp, increase Ti
- Funcția de somn (P5.09=1): At low flow, when pressure exceeds setpoint for a period, inverter drops to min frequency then stops; restarts when pressure drops below wake-up threshold. Suitable for small water systems.
Switching Tip
Cu mai multe viteze: P0.03=8
PID constant pressure: P0.03=10
Change P0.03 and power cycle inverter for best stability.
Full ALPHA6000M Series Model List (ALPHA Mini Vector Inverters)
- Regula de codificare a modelului
ALPHA6000M S2 R75 G B RSM
- S2: Single-phase 220V input; 3: 3-phase 380V input
- R75=0.75kW; 1R5=1.5kW; 2R2=2.2kW
- G: General constant torque load; P: Ventilator & pump variable torque load
- B: Unitate de frânare încorporată (this model has B)
- RSM: RS485 Modbus communication option suffix
Important note: S2R4GB and S2R75GB only support V/F, no SVC vector; higher power models support vector control
- Monofazat 220V (S2 series, mini type, same family as your unit)
Standard models (built-in braking unit GB)
- ALPHA6000M-S2R4GB | 0.4kW
- ALPHA6000M-S2R75GB | 0.75kW (base model of your unit)
- ALPHA6000M-S21R5GB | 1.5kW
- ALPHA6000M-S22R2GB | 2.2kW
With communication suffix RSM
S2R4GBRSM
S2R75GBRSM (modelul dvs)
S21R5GBRSM
S22R2GBRSM
- 3-faza 380V (3 serie, dual rating G/P)
Small power integrated type (unitate de frânare încorporată)
- ALPHA6000M-3R75GB/31R5PB | 0.75kW(G)/1.5kW(P)
- ALPHA6000M-31R5GB/32R2PB | 1.5kW(G)/2.2kW(P)
- ALPHA6000M-32R2GB/3004PB | 2.2kW(G)/4kW(P)
- ALPHA6000M-3004GB/35R5PB | 4kW(G)/5.5kW(P)
- ALPHA6000M-35R5GB/37R5PB-N | 5.5kW(G)/7.5kW(P)
- ALPHA6000M-37R5GB/3011PB | 7.5kW(G)/11kW(P)
Putere medie (SJ suffix, external braking unit required)
- 3011GB/3015PB-SJ | 11/15kW
- 3015GB/3018PB-SJ | 15/18.5kW
- 3018GB/3022PB-SJ | 18.5/22kW
- 3022GB-SJ | 22kW
Ventilator & pump only P type (no G rating)
3030P-N, 3037P-N, 3045P-N … up to 3630P-N
- ALPHA6000M vs 6000E (Referință de înlocuire)
- 6000M: Mini compact version
Max power 22kW; small S2 single-phase units, compact terminals; S2R4/S2R75 no vector support; smaller mounting cutout, not interchangeable with 6000E.
- 6000E: Standard universal version
Power range 0.75~630kW; vector supported on all ratings; larger enclosure and mounting holes, incompatible with M series housing.
- Same Power Alternatives for S2R75GBRSM
Same series original: ALPHA6000M-S2R75GBRSM
Same power without communication: ALPHA6000M-S2R75GB
3-phase equivalent: 3R75GB (3-phase 380V input)
- Rated Current Table (Single-phase S2)
| Model | Putere | Curent de intrare | Curent de ieșire |
| S2R4GB | 0.4kW | 5.1O | 2.4O |
| S2R75GB | 0.75kW | 9.2O | 4.5O |
| S21R5GB | 1.5kW | 13.1O | 7O |
| S22R2GB | 2.2kW | 23O | 10O |
Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor