The Chint NXC-75/220V AC contactor is a commonly used industrial-grade control device suitable for controlling three-phase loads with a rated current of 75A and a coil voltage of 220V. Below is a detailed analysis of this contactor model:
- Basic Parameters and SpecificationsSchneider LC1DN3210 and Chint NXC32 contactors
- Parametrii nominaliContactor DC Chint NC1-5011-36V
Semnificația modelului: NXC-75 (design series)/220V (tensiunea bobinei)
Curent nominal: 75O (can control 37kW three-phase motors under AC-3 usage category)
Tensiunea bobinei: 220V și (50/60Hz)
Configurația stâlpului: 3 stâlpi (contactele principale) + 2 deschis în mod normal (NU) + 2 în mod normal închis (NC) contacte auxiliare
Viața mecanică: 10 milioane de operațiuni
Viața electrică: 1 milioane de operațiuni (Categoria AC-3)
- Scenarii de aplicareCablajul Contactorului AC Delixi
– Început, Stop, and forward/reverse control of three-phase motors
– On/off control of electric heating equipment and lighting circuits
– Combined with thermal relays to form motor protection circuits
- Core Structure and Terminal DescriptionContactor AC CHINT CJX2
- Appearance and Components

(Schematic diagram; actual product may vary)
- Aspect terminal
| Tip terminal | Identification/Number | Descrierea funcției |
| Contacte principale | L1/T1, L2/T2, L3/T3 | Three-phase power input/output (L1-L3 for power supply, T1-T3 for load) |
| Terminale bobine | A1, A2 | 220V coil power supply (A1 to live wire, A2 to neutral wire) |
| Contacte auxiliare | 13/14 (NU), 21/22 (NC) | Control circuit signal feedback (NU/NC) |
| Thermal Relay Interface | 95/96, 97/98 | Connect to thermal relay for overload protection |
III. Typical Application Wiring Diagrams
Scenariu 1: Direct Start Control of Three-Phase Motor
Explicaţie:
– Întrerupător (Q): Protects the circuit from overloads and short circuits
– Contactor (KM): Main contacts control motor power supply; coil A1/A2 connected to 220V
– Butonul Start (SB1): When pressed, the coil is energized, main contacts close, iar motorul porneste
Scenariu 2: Motor Control with Overload Protection
Explicaţie:
– Releu termic (FR): Connected to the main circuit via terminals 95/96; NC contacts 97/98 are wired in series in the control circuit
– During overload, the bimetallic strip in FR heats and bends, opening the NC contacts, de-energizing the contactor coil, and stopping the motor
- Precauții de instalare și utilizare
- Cerințe de mediu
– Interval de temperatură: -5°C ~ +40°C
– Umiditate: ≤95%RH (fara condens)
– Altitudine: ≤2000 de metri
- Etape de instalare
– Install vertically to maintain heat dissipation space
– Use M8 bolts for main circuit terminals, tightening torque 8-10N·m
– Use 0.75-2.5mm² wires for control circuits to ensure good contact
- Puncte cheie de întreținere
– Regularly clean oxide layers on contact surfaces
– Check for loose bolts (at least once a year)
– Coil temperature rise should not exceed 65K (at 40°C ambient temperature)
- Defecte comune și soluții
| Fenomen de eroare | Cauze posibile | Soluții |
| Coil not energizing | Power not connected, coil burned out, mechanical jamming | Check voltage, replace coil, clean components |
| Supraîncălzirea contactului | Contact slab, excessive load, oxidare de contact | Strângeți bornele, reduce load, contacte de lustruire |
| Not releasing after power-off | Residual magnetism in core, contact adhesion | Replace core, clean or replace contacts |
| Excessive noise | Broken core short-circuit ring, fluctuatii de tensiune | Replace core, stabilize power supply voltage |
- Selection Alternatives
If NXC-75 is out of stock, consider the following alternative models:
Schneider LC1-D75: Same specifications, compatibilitate puternică
Siemens 3TF52: Higher reliability, suitable for critical applications
ABB A9-40/75: Design modular, easy to expand
Nota: La înlocuire, confirm that coil voltage, capacitatea de contact, iar dimensiunile de instalare sunt consistente.
Rezumat
The Chint NXC-75/220V AC contactor is a reliable industrial control component that can effectively manage three-phase loads through proper wiring and maintenance. Înainte de utilizare, verify power supply compatibility and prioritize control circuits with overload protection to extend equipment life and ensure safety.
Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare













NH42-63-318x560.png)