DELIXI CJX2-25 AC Contactor

DELIXI CJX2-25 is a general-purpose AC contactor with a rated current of 25A. It complies with IEC 60947-4-1 and GB/T14048.4 standards. It is mainly used for remote making and breaking of circuits, as well as frequent starting and control of AC motors. Model Code Explanation Code Meaning CJ AC Contactor X2 Design sequence number 25 ...

  • Detalii despre produs

DELIXI CJX2-25 is a general-purpose AC contactor with a rated current of 25A. It complies with IEC 60947-4-1 and GB/T14048.4 standards. It is mainly used for remote making and breaking of circuits, as well as frequent starting and control of AC motors.

  1. Model Code Explanation
CodSens
CJContactor AC
X2Design sequence number
25Rated current of main poles: 25O
Suffix (de ex. 10/01/11)Auxiliary contact configuration:
10 = 1 NU, 0 NC
01 = 0 NU, 1 NC
11 = 1 NU, 1 NC
Coil voltage codeM = AC220V, Q = AC380V
Other options: AC24V, 36V, 48V, 110V, 127V

Complete model example: CJX2-2510M (25O, 1 NU + 0 NC, AC220V coil)

  1. Parametrii tehnici cheie
ArticolValoareObservații
Rated operational current25O (AC‑3, 380V)Corresponding motor power: 7.5kW (380V)
Tensiunea nominală de izolație690VMaximum operating voltage
Tensiune nominală de funcționareUp to 690V50/60Hz universal
Main contact configuration3NU (3 Deschis normal)Configurație standard
Contacte auxiliare1NU / 1NC / 1NU+1NCOptional configurations
Tensiunea bobineiAC24V ~ 380VMultiple specifications available
Mechanical endurance≥ 10 milioane de operațiuniOperating frequency ≤ 1200 operațiuni/oră
Electrical endurance≥ 1 milioane de operațiuniUtilization category AC‑3
Mounting methodScrew mounting / Rail mountingCompatible with standard 35mm DIN rail
Degree of protectionIP20Previne contactul degetelor cu piesele sub tensiune

III. Mediul de operare

  1. Temperatura mediului ambiant: -5℃ ~ +40℃, average temperature over 24 hours ≤ +35℃
  2. Altitudine: ≤ 2000m; derating required above this altitude
  3. Relative humidity: 90% (at +25℃), fara condens
  4. Mounting condition: Vertical mounting (înclinare ≤ 5°), no significant vibration or shock
  5. Pollution degree: 3, potrivite pentru medii industriale
  6. Cross-Reference / Replacement Models (Other Brands)
MarcaModel de înlocuireCompatibilitate
SchneiderLC1D25Compatible dimensions and mounting holes, înlocuire directă
Siemens3RT2026Functionally equivalent, identical electrical parameters
CHINTNXC‑25 (formerly CJX2‑25)Same platform, fully interchangeable
ABBA16‑30‑01 (note rated current difference)25A equivalent: A26‑30‑01
  1. Official Order Codes & Lista completă de modele

Complete models of DELIXI CJX2-25 series (based on official data):

Main ModelContacte auxiliareTensiunea bobineiOrder Code Example
CJX2‑2510 (1NU)AC220VCJX22510M
CJX2‑2510 (1NU)AC380VCJX22510Q
CJX2‑2501 (1NC)AC220VCJX22501M
CJX2‑2501 (1NC)AC380VCJX22501Q
CJX2‑2511 (1NU+1NC)AC220VCJX22511M
CJX2‑2511 (1NU+1NC)AC380VCJX22511Q
CJX2‑2504 (4NU)AC220VCJX22504M
  1. Engineering Application Recommendations
  2. Ghid de selecție

Select the appropriate model based on load type (resistive/inductive), curent nominal, control voltage, and operating frequency.

  1. Note de instalare

Inspect product appearance before installation to ensure no damage

Tighten terminal screws securely to avoid overheating from loose connections

When used with thermal relays, maintain a gap ≥ 5mm for heat dissipation

  1. Sugestii de intretinere

Regularly check contact wear; replace contacts if wear exceeds 1mm

Clean the coil core surface to remove dust and oil for reliable attraction

Inspect and retighten loose wiring terminals

VII. Key Tips

  1. CJX2-25 is a standard contactor for general industrial control. For high-frequency operation (>600 operațiuni/oră), the CJX2S series (Pioneer series) este recomandat.
  2. Coil voltage must match the control circuit voltage to prevent coil burnout.
  3. When replacing contactors of other brands, verify mounting dimensions and wiring methods to ensure compatibility.

DELIXI Contactors-Full Series Model List (Official 2026 Ediţie)

DELIXI contactors are classified into General AC Contactors, DC Contactors, and Special-Purpose Contactors by technical platform and application scenario. They cover a full current range from 0.9A to 1000A, meeting demands in industry, construction, new energy, and other fields.

  1. General AC Contactors (Mainstream Series)
  2. CJX2s Series (Pioneer Series, Ideal for High-Frequency Operation)

Poziționare: Upgraded version of classic CJX2, suitable for high-frequency start/stop equipment such as fans and pumps

Key parameters: Rated current 6A~95A, AC-3 380V, rated insulation voltage 690V, operating frequency ≤ 1800 operațiuni/oră

Complete model list:

Main ModelAuxiliary Contact Config.Coil Voltage CodeOrder Code Example
CJX2s‑0610/01/11/22M(AC220V)/Q(AC380V)/

O(AC110V)/D(DC24V)

CJX2s0610M
CJX2s‑0910/01/11/22M/Q/A/DCJX2s0901Q
CJX2s‑1210/01/11/22M/Q/A/DCJX2s1211M
CJX2s‑1810/01/11/22M/Q/A/DCJX2s1822Q
CJX2s‑2510/01/11/22M/Q/A/DCJX2s2510M
CJX2s‑3210/01/11/22M/Q/A/DCJX2s3201Q
CJX2s‑3810/01/11/22M/Q/A/DCJX2s3811M
CJX2s‑4010/01/11/22M/Q/A/DCJX2s4022Q
CJX2s‑5010/01/11/22M/Q/A/DCJX2s5010M
CJX2s‑6510/01/11/22M/Q/A/DCJX2s6501Q
CJX2s‑8010/01/11/22M/Q/A/DCJX2s8011M
CJX2s‑9510/01/11/22M/Q/A/DCJX2s9522Q

Caracteristici: Upgraded silver contact technology, 70%–120% wide voltage pull-in, mechanical endurance ≥ 10 milioane de operațiuni, electrical endurance ≥ 1 milioane de operațiuni

  1. CJX2 Series (Classic General-Purpose Type)

Poziționare: Traditional general contactor, cost-effective choice

Key parameters: Rated current 9A~95A, AC-3 380V, rated insulation voltage 690V, operating frequency ≤ 1200 operațiuni/oră

Complete model list:

Main ModelAuxiliary Contact Config.Coil Voltage CodeOrder Code Example
CJX2‑0910/01/11M/Q/A/DCJX20910M
CJX2‑1210/01/11M/Q/A/DCJX21201Q
CJX2‑1810/01/11M/Q/A/DCJX21811M
CJX2‑2510/01/11M/Q/A/DCJX22510M
CJX2‑3210/01/11M/Q/A/DCJX23201Q
CJX2‑4010/01/11M/Q/A/DCJX24011M
CJX2‑5010/01/11M/Q/A/DCJX25010M
CJX2‑6510/01/11M/Q/A/DCJX26501Q
CJX2‑8010/01/11M/Q/A/DCJX28011M
CJX2‑9510/01/11M/Q/A/DCJX29510M
  1. CJX1 Series (Traditional High-Power Type)

Poziționare: Economical high-power motor control, replaces part of CJ20 series

Key parameters: Rated current 9A~475A, AC-3 380V, rated insulation voltage 690V

Complete model list:

Main ModelAuxiliary Contact Config.Tensiunea bobineiOrder Code Example
CJX1‑922 (2NU+2NC)AC220V/380VCJX1922M
CJX1‑1222AC220V/380VCJX11222Q
CJX1‑1622AC220V/380VCJX11622M
CJX1‑2222AC220V/380VCJX12222Q
CJX1‑3222AC220V/380VCJX13222M
CJX1‑4522AC220V/380VCJX14522Q
CJX1‑7522AC220V/380VCJX17522M
CJX1‑8522AC220V/380VCJX18522Q
CJX1‑10022AC220V/380VCJX110022M
CJX1‑14022AC220V/380VCJX114022Q
CJX1‑17022AC220V/380VCJX117022M
CJX1‑20522AC220V/380VCJX120522Q
CJX1‑25022AC220V/380VCJX125022M
CJX1‑30022AC220V/380VCJX130022Q
CJX1‑40022AC220V/380VCJX140022M
CJX1‑47522AC220V/380VCJX147522Q
  1. CJ20 Series (Traditional Classic High-Power)

Poziționare: Heavy-duty motor control, suitable for heavy-load scenarios such as metallurgy and mining

Key parameters: Rated current 10A~630A, AC-3 380V, rated insulation voltage 1140V

Complete model list:

Main ModelAuxiliary Contact Config.Tensiunea bobineiApplicable Motor Power (380V)
CJ20‑1022AC220V/380V5.5kW
CJ20‑1622AC220V/380V7.5kW
CJ20‑2522AC220V/380V11kW
CJ20‑4022AC220V/380V18.5kW
CJ20‑6322AC220V/380V30kW
CJ20‑10022AC220V/380V55kW
CJ20‑16022AC220V/380V90kW
CJ20‑25022AC220V/380V132kW
CJ20‑40022AC220V/380V200kW
CJ20‑63022AC220V/380V315kW
  1. CJ40 Series (New-Generation High-Power Contactors)

Poziționare: Replaces CJ20, preferred for industrial power distribution, energy-saving and efficient

Key parameters: Rated current 63A~630A, AC-3 380V, rated insulation voltage 1140V, power consumption reduced by 30%

Complete model list:

Main ModelAuxiliary Contact Config.Tensiunea bobineiApplicable Motor Power (380V)
CJ40‑6322AC220V/380V30kW
CJ40‑10022AC220V/380V55kW
CJ40‑16022AC220V/380V90kW
CJ40‑25022AC220V/380V132kW
CJ40‑40022AC220V/380V200kW
CJ40‑50022AC220V/380V250kW
CJ40‑63022AC220V/380V315kW
  1. CDC6 Series (For Automation, High Cost-Performance)

Poziționare: Dedicated for automated production lines and test equipment, matches CDR6 thermal relays

Key parameters: Rated current 9A~630A, AC-3 380V, rated insulation voltage 690V

Complete model list:

Main ModelAuxiliary Contact Config.Tensiunea bobineiOrder Code Example
CDC6‑0911AC220V/380VCDC60911M
CDC6‑1211AC220V/380VCDC61211Q
CDC6‑1811AC220V/380VCDC61811M
CDC6‑2511AC220V/380VCDC62511Q
CDC6‑3211AC220V/380VCDC63211M
CDC6‑4011AC220V/380VCDC64011Q
CDC6‑5011AC220V/380VCDC65011M
CDC6‑6511AC220V/380VCDC66511Q
CDC6‑8011AC220V/380VCDC68011M
CDC6‑9511AC220V/380VCDC69511Q
CDC6‑11522AC220V/380VCDC611522M
CDC6‑15022AC220V/380VCDC615022Q
CDC6‑18522AC220V/380VCDC618522M
CDC6‑22522AC220V/380VCDC622522Q
CDC6‑26522AC220V/380VCDC626522M
CDC6‑33022AC220V/380VCDC633022Q
CDC6‑40022AC220V/380VCDC640022M
CDC6‑50022AC220V/380VCDC650022Q
CDC6‑63022AC220V/380VCDC663022M
  1. CDC6i Series (New 6 Serie, Intelligent Control)

Poziționare: For automated production and testing equipment, compatible with intelligent control modules

Key parameters: Rated current 9A~95A, AC-3 380V, Protectie IP20, compatible with smart modules

Complete model list:

Main ModelAuxiliary Contact Config.Tensiunea bobineiOrder Code Example
CDC6i‑0910/01/11AC220V/380VCDC6i0910M
CDC6i‑1210/01/11AC220V/380VCDC6i1201Q
CDC6i‑1810/01/11AC220V/380VCDC6i1811M
CDC6i‑2510/01/11AC220V/380VCDC6i2510M
CDC6i‑3210/01/11AC220V/380VCDC6i3201Q
CDC6i‑4010/01/11AC220V/380VCDC6i4011M
CDC6i‑5010/01/11AC220V/380VCDC6i5010M
CDC6i‑6510/01/11AC220V/380VCDC6i6501Q
CDC6i‑8010/01/11AC220V/380VCDC6i8011M
CDC6i‑9510/01/11AC220V/380VCDC6i9510M
  1. CDC10 Series (Traditional Economical Type)

Poziționare: Building power distribution and general motor control, large market inventory

Key parameters: Rated current 10A~150A, AC-3 380V

Complete model list:

Main ModelAuxiliary Contact Config.Tensiunea bobineiAplicație
CDC10‑1022AC220V/380VSmall motors
CDC10‑2022AC220V/380VSmall motors
CDC10‑4022AC220V/380VMedium motors
CDC10‑6022AC220V/380VMedium motors
CDC10‑10022AC220V/380VMotoare mari
CDC10‑15022AC220V/380VMotoare mari
  1. CDC1 Series (Mini Contactors)

Poziționare: Precision control and small equipment, replaces intermediate relays

Key parameters: Rated current 3A~12A, AC220V/380V

Complete model list:

Main ModelAuxiliary Contact Config.Tensiunea bobineiAplicație
CDC1‑310/0124V/110V/220VPrecision instruments
CDC1‑610/0124V/110V/220VEchipament mic
CDC1‑910/0124V/110V/220VSmall motors
CDC1‑1210/0124V/110V/220VSmall motors
  1. DC Contactor Series
  2. CZ0 Series (For Industrial DC Motor Control)

Poziționare: Remote frequent making/breaking of DC circuits, control of DC motors

Key parameters: Rated current 10A~600A, rated voltage up to 440V DC

Complete model list:

Main ModelContact Config.Tensiunea bobineiOrder Code Example
CZ0‑1010/01DC220V/440VCZ01010DC220V
CZ0‑2010/01DC220V/440VCZ02001DC440V
CZ0‑4010/01DC220V/440VCZ04010DC220V
CZ0‑10010/01DC220V/440VCZ010001DC440V
CZ0‑15010/01DC220V/440VCZ015010DC220V
CZ0‑20010/01DC220V/440VCZ020001DC440V
CZ0‑30010/01DC220V/440VCZ030010DC220V
CZ0‑40010/01DC220V/440VCZ040001DC440V
CZ0‑60010/01DC220V/440VCZ060010DC220V
  1. CDZJ Series (Solenoid-Type DC Contactors)

Poziționare: Început, reverse, brake of DC motors; control of lifting electromagnets

Key parameters: Rated current 50A~400A, single/dual coil optional, intermittent duty

Complete model list:

Main ModelStructure TypeTensiunea bobineiOrder Code Example
CDZJ‑50ADeschis normalDC12V/24V/48V/110V/220VCDZJ50ADDC24V
CDZJ‑50BÎn mod normal închisDC12V/24V/48V/110V/220VCDZJ50BDDC24V
CDZJ‑100ADeschis normalDC12V/24V/48V/110V/220VCDZJ100ADDC24V
CDZJ‑100BÎn mod normal închisDC12V/24V/48V/110V/220VCDZJ100BDDC24V
CDZJ‑200ADeschis normalDC12V/24V/48V/110V/220VCDZJ200ADDC24V
CDZJ‑200BÎn mod normal închisDC12V/24V/48V/110V/220VCDZJ200BDDC24V
CDZJ‑400ADeschis normalDC12V/24V/48V/110V/220VCDZJ400ADDC24V
CDZJ‑400BÎn mod normal închisDC12V/24V/48V/110V/220VCDZJ400BDDC24V
  1. CDEV6i Series (New Energy High-Voltage DC Contactors)

Poziționare: EV charging piles, battery power distribution systems, solar power equipment

Key parameters: Rated voltage DC1000V, rated current 50A~400A, IP67 protection

Complete model list:

Main ModelContact Config.Tensiunea bobineiAplicație
CDEV6i‑5010DC12V/24VSmall charging piles
CDEV6i‑10010DC12V/24VMedium charging piles
CDEV6i‑20010DC12V/24VLarge charging piles
CDEV6i‑30010DC12V/24VEnergy storage systems
CDEV6i‑40010DC12V/24VElectric vehicle batteries

III. Special-Purpose Contactors

  1. CDZ7 Series (Contactor-Type Relays)

Poziționare: Signal amplification and transmission in control circuits, replaces intermediate relays

Key parameters: Rated current 5A~10A, AC/DC universal control voltage

Complete model list: CDZ7-52P, CDZ7-101P, CDZ7-102P, CDZ7-104P

  1. CDC7 Series (Interlocked Contactors)

Poziționare: Reversible control circuits, prevents reverse power connection

Key parameters: Rated current 9A~95A, AC-3 380V, reliable mechanical interlock

Complete model list: CDC7-09, CDC7-12, CDC7-18, CDC7-25, CDC7-32, CDC7-40, CDC7-50, CDC7-65, CDC7-80, CDC7-95

  1. CDCH8s Series (Gospodărie / Small Commercial Contactors)

Poziționare: Light loads such as lighting and air conditioning, residential and small commercial buildings

Key parameters: Rated current 6A~63A, AC220V/400V, 2P/4P optional

Complete model list: CDCH8s-6, CDCH8s-10, CDCH8s-16, CDCH8s-20, CDCH8s-25, CDCH8s-32, CDCH8s-40, CDCH8s-50, CDCH8s-63

  1. Selecţie & Ghid de înlocuire
SerieBest ApplicationÎnlocuireObservații
CJX2sHigh‑frequency start/stop (>600 operațiuni/oră)Replaces CJX2, Schneider LC1DWide voltage pull‑in, long endurance
CJX2General industrial controlReplaces CHINT NXC, ABB A SeriesEficient din punct de vedere al costurilor, highly versatile
CJ40High‑power motors (>100kW)Replaces CJ20, Siemens 3RTEnergy‑saving, easy maintenance
CDC6Automated production linesReplaces Siemens 3RT, ABB A SeriesCompatible with smart modules
CZ0/CDZJControl motor DCReplaces Siemens 3RT DC typeSolenoid structure, high breaking capacity
CDEV6iNew energy applicationsNo direct replacementIP67, high‑voltage DC
  1. Reguli de denumire a modelului

DELIXI contactor models follow these rules:

  1. Basic code: CJ = AC Contactor, CZ = DC Contactor, CDC = General Contactor
  2. Design number: X2 = 2nd generation, X1 = 1st generation, 40 = 40th generation
  3. Curent nominal: Directly marked in amps (O), de ex., 25 = 25A
  4. Contacte auxiliare: 10 = 1NO 0NC, 01 = 0NO 1NC, 11 = 1NO 1NC, 22 = 2NO 2NC
  5. Tensiunea bobinei: M = AC220V, Q = AC380V, A = AC110V, D = DC24V; special voltages marked numerically

Translation Notes

All brand & model names (CJX2, CDC6, LC1D, 3RT etc.) kept unchanged as industry standard identifiers

Technical terms aligned with IEC / international electrical engineering usage

Format (headings, tables, structure) preserved exactly for engineering documentation use

Prev: