Finder 7S.14.9.024.0220 Modul releu de siguranță cu contact ghidat forțat - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

Finder 7S.14.9.024.0220 Modul releu de siguranță cu contact ghidat forțat - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

electric/

Finder 7S.14.9.024.0220 Modul releu de siguranță cu contact ghidat forțat

Finder 7S.14.9.024.0220 Forced Guided Contact Safety Relay Module Model Code Interpretation Segment Code Meaning Series Code 7S Finder 7S series forced guided contact safety relay module, conform EN 50205:2002 Type A Contact Configuration 14 4-pol, 2 Deschis normal + 2 Normally Closed contacts Mounting & Terminal 9 Montare pe șină DIN, cage-clamp terminal, 22.5mm latime ...

  • Detalii despre produs

Finder 7S.14.9.024.0220 Modul releu de siguranță cu contact ghidat forțat

  1. Interpretarea Codului Modelului
SegmentCodSens
Cod de serie7SFinder 7S series forced guided contact safety relay module, conform EN 50205:2002 Tip A
Configurare contact144-pol, 2 Deschis normal + 2 Contacte normal închise
Montare & Terminal9Montare pe șină DIN, cage-clamp terminal, 22.5mm latime
Tensiunea bobinei2424V DC control coil
Versiune & Caracteristică220Standard version without extra functions
  1. Core Specification Table
CategorieParametruObservații
Informații de bază
ProducătorFinderFamous Italian relay brand
Tip de produsForced guided contact safety relay moduleNon-latching type
Număr de ordine7S.14.9.024.0220 / 7S1490240220Two formats are both applicable
Parametrii electrici
Tensiunea bobinei24În DCStandard industrial control voltage
Consumul de energie al bobinei1.2WTypical value
Contact Arrangement2NU+2NC (4P)Forced guided design for synchronous contact operation
Curent nominal6A @ 250V AC (AC-1)Rated value for different load types
6A @ 30V DC (DC-1)
3A @ 230V AC (AC-15)
Material de contactAgNi Silver Nickel AlloyHigh conductivity and wear resistance
Mecanic & Parametrii de mediu
Tip de instalareDIN Rail (ÎN 60715)22.5mm compact width
Tip terminalCage-clampScrewless wiring, instalare ușoară
Grad de protecțieIP20Rezistent la degete, suitable for cabinet interior
Temperatura de operare-40°C ~ +70°CWide temperature range for industrial use
Temperatura de depozitare-40°C ~ +85°C
CertificareÎN 50205:2002 Tip A, ÎN 13849-1International safety relay standards
Durata de viațăMecanic: 10⁷ operațiuni
Electric: 10⁵ operațiuni la sarcină nominală
  1. Cross-brand Replacement Reference
MarcaModelAsemănăriDiferențele
CiupercăPNOZ X2.8P 24VDC2NU+2NC, 24VDC, forced guided contactProfessional safety relay, higher price and richer functions
Siemens3TK2825-1BB402NU+2NC, 24VDC, Montare pe șină DINBetter compatibility in industrial automation
SchneiderSe caută SR2B121BD2NU+2NC, 24VDC, forced guided contactDifferent terminal design, rentabil
OmronG9SA-321-T0752NU+2NC, 24VDC, safety certifiedDimensiune compactă, ideal for limited space
  1. 7S Series Main Model List
ModelContact LayoutTensiunea bobineiTip terminalCaracteristica specială
7S.12.9.024.02202P (1NU+1NC)24În DCCage-clampStandard
7S.14.9.024.02204P (2NU+2NC)24În DCCage-clampStandard (acest produs)
7S.16.9.024.02206P (3NU+3NC)24În DCCage-clampStandard
7S.14.9.230.02204P (2NU+2NC)230V șiCage-clampStandard
7S.14.9.024.42204P (2NU+2NC)24În DCCage-clampLED status indicator
7S.14.9.024.52204P (2NU+2NC)24În DCScrew terminalStandard
7S.34.9.024.02204P (2NU+2NC)24În DCCage-clamp10Un curent nominal
  1. Depanare & Ghid de întreținere

5.1 Common Fault Analysis

Fenomen de eroareCauze posibileInspection Steps
Coil fails to pull in1. Insufficient or reversed coil voltage1. Measure coil voltage to confirm 24V DC
2. Colac ars2. Test coil resistance (normal: approx 480Ω)
3. Cabluri slăbite3. Check terminal tightness
No contact movement1. Jammed forced guided mechanism1. Check mechanical flexibility after power off
2. Oxidized or burnt contacts2. Inspect contact surface damage
3. Mechanical wear3. Verify contact travel distance
Lipirea contactului1. Arc burn caused by overload or short circuit1. Check actual load exceeding rating
2. Contact material fatigue2. Replace relay module
LED indicator off1. Damaged LED1. Check power supply connection
2. Power disconnection2. Replace with identical module for test
3. Internal circuit failure

5.2 Întreţinere & Sugestie de înlocuire

  1. Safety Priority: Cut off power and wait at least 5 minutes for capacitor discharge before maintenance.
  2. Modular Structure: On-site repair is not recommended; integral replacement is preferred.
  3. Replacement Procedure

Record wiring positions by photos or sketches

Remove old module from DIN rail

Install new module and reconnect wires accordingly

Power on and verify normal operation

  1. Preventive Maintenance

Inspect terminal connection every 6 luni

Avoid overload, reserve 30% current margin

Shorten replacement cycle to 2-3 years under harsh conditions

  1. Scenarii de aplicare & Cazuri industriale

6.1 Applicable Fields

IndustrieAplicație tipicăFuncția de siguranță
Machinery ManufacturingEmergency stop circuit, safety door monitoringPrevent accidental startup, protect operators
Automatic Production LineSafety light curtain, two-hand control circuitSecure operating area safety
Elevator & EscalatorDoor lock monitoring, safety loopAvoid unexpected elevator movement
Tranzit FeroviarDoor control, braking systemComply with railway safety standards
Mașini de ambalareGuardrail monitoring, oprire de urgențăPersonnel injury prevention

6.2 Inadmissible Working Conditions

High vibration environment such as stamping machines, shockproof bracket required

Humid and dusty environment, IP54+ sealed enclosure needed

Ultra-high frequent switching over 10 cycles per minute, solid state relay recommended

High current load over 6A / 250V și, contactor required for capacity expansion

6.3 Sfaturi de selecție & Avoidance Notes

  1. Distinguish forced guided contact from ordinary relay; ÎN 50205 compliant type mandatory for safety application
  2. Confirmați tensiunea bobinei, avoid AC and DC confusion; this model is 24V DC
  3. Match load type with corresponding rated current (AC-1/AC-15/DC-1)
  4. Reserve enough installation space for 22.5mm width module
  5. Ensure compliance with EN 13849-1 for industrial safety usage

Application Scenarios of Finder 7S.14.9.024.0220

Equipped with forced guided safety contacts, conforming to EN13849 and EN50205 safety standards, applied for equipment safety loop control.

  1. General Industrial Machinery
  2. Masini-unelte: Emergency stop circuit, safety door interlock, tool magazine safety lock
  3. Stamping & forging machines: Guard fence detection, slide safety limit
  4. Injection molding machines: Mold safety door, manipulator area protection interlock
  5. Automatic Production Line
  6. Conveyor line: Light curtain safety protection, station access judgment
  7. Assembly equipment: Two-hand startup circuit, robot fence access control
  8. Sorting & mașini de ambalare: Flip cover protection, fault emergency stop interlock
  9. Ridicare & Hoisting Equipment
  10. Small lift, cargo elevator door control safety circuit
  11. Crane lifting tool limit protection, power-off safety lock
  12. Industria ușoară & Special Machinery
  13. Safety stop interlock for printing and textile machinery
  14. Safety door monitoring for wood cutting equipment
  15. Fault power-off protection for fans and water pumps
  16. Transportation & Building Auxiliary
  17. Automatic door and escalator safety detection circuit
  18. Vehicle industrial control, miniature railway equipment safety protection
  19. Control Cabinet Internal Control
  20. System emergency power-off safety loop
  21. High voltage cabinet access control and leakage safety interlock

Unsuitable Environments

Non-sealed cabinet with strong corrosion and heavy dust

Ultra-high frequency switching working condition

Working current exceeding 6A rated load

Prev: