IFM PM1704 Flush Hygienic Pressure Sensor - Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

 IFM PM1704 Flush Hygienic Pressure Sensor - Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor

Senzor/

IFM PM1704 Flush Hygienic Pressure Sensor

P.M-010-REA01-E-ZVG/US PM1704 belongs to IFM PM17 series, a flush diaphragm hygienic pressure transmitter, designed for hygienic processes in food & băutură, farmaceutic, bioengineering industries with CIP/SIP cleaning requirements. ✅ Model Code Definition PM: Pressure transmitter, hygienic flush diaphragm series 010: Measuring range 0~10 bar (gauge pressure, adjustable downward) REA01: Aseptoflex Vario G1 external thread hygienic ...

  • Detalii despre produs

P.M-010-REA01-E-ZVG/US

PM1704 belongs to IFM PM17 series, a flush diaphragm hygienic pressure transmitter, designed for hygienic processes in food & băutură, farmaceutic, bioengineering industries with CIP/SIP cleaning requirements.

✅ Model Code Definition

P.M: Pressure transmitter, hygienic flush diaphragm series

010: Measuring range 0~10 bar (gauge pressure, adjustable downward)

REA01: Aseptoflex Vario G1 external thread hygienic process connection

E: Equipped with IO-Link communication

ZVG/US: M12 connector version

📊 Core Technical Specifications

ArticolCaietul de sarcini
Domeniul de măsurare-1 … 10 bar (-0.1~1 MPa, gauge pressure), factory setting 0~10 bar
Ieșire4…20 mA analog + 1 switching output + IO-Link
Precizie≤±0.2% FS (including linearity & hysteresis); repeatability <±0.1%FS
Temperatura medie-25 … +150 ℃ (compatible with SIP high-temperature sterilization)
Temperatura ambiantă-25 … +85 ℃
Alimentare electricăDC 18 ~ 30 V, protectie inversa polaritatii
Conexiune la procesG1″ male thread with Aseptoflex Vario hygienic sealing
Wetted Parts MaterialDiafragmă: 99.9% alumina ceramic; wetted housing: 1.4435 (316L) oţel inoxidabil
Conexiune electricăM12 A-coded, 4-pin gold-plated connector
Clasa de protectieIP67 / IP69K (suitable for high-pressure spray cleaning)
Overpressure15 bar; Burst pressure 30 bar
Durata de viață≥100 million pressure cycles
Cuplul de strângere35 Nm
GreutateAproximativ. 308 g

📜 Certifications (Hygiene Compliance)

EHEDG, 3-O, FDA, EC1935/2004, ACS, cULus, UKCA, meeting hygienic requirements for food and pharmaceutical industries.

🛠️ Product Features

  1. Flush dead-space-free diaphragm: No recess to trap media, suitable for viscous materials (gem, yoghurt, pharmaceutical liquids) for CIP/SIP cleaning.
  2. IO-Link: Read pressure, temperature and diagnostic data; remote scaling of 4-20mA range, alarma de eroare.
  3. Resistant to cleaning chemicals, withstand high-pressure washing per IP69K.
  4. Customizable switch points; analog measuring range freely adjustable via IO-Link (turndown configurable).

🧩 Typical Applications

Tank pressure measurement in food & băutură, fermenters, pharmaceutical preparation tanks, emulsification processes, hygienic pipeline pressure measurement.

⚠️ Installation & Note de întreținere

  1. Tightening torque strictly limited to 35 Nm; over-torque may crack the ceramic diaphragm.
  2. Do not strike the diaphragm with hard objects; flush surface must be level with tank inner wall to prevent material buildup.
  3. Heating and cooling rates during CIP/SIP shall not be too fast to avoid thermal shock damage to the senzor.
  4. Accesorii optionale: Aseptoflex welding adapter, certificat de calibrare, M12 cable, replacement sealing gasket.

🔁 Alternative Model Reference

PM1604: Same measuring range, non-Aseptoflex interface, standard G1 thread (without Vario hygienic seal)

PI1704: Same interface and range, with built-in temperature measurement (PM1704 does NOT measure medium temperature)

PM1705: -1…4 bar; PM1714: 0…16 bar (aceeasi serie, different measuring ranges)

❗ Common Troubleshooting

  1. 4-20mA fixed at full scale: Diaphragm damage / suprapresiune, short circuit in wiring.
  2. Reading drift: Aged sealing ring, thermal shock, medium crystal deposits on diaphragm surface.
  3. IO-Link communication failure: Tensiune de alimentare insuficientă, oxidized M12 pins, incorrect baud rate configuration of IO-Link master.

IFM PM17 Series Hygienic Flush Diaphragm Pressure Transmitter

PM17 is IFM’s Aseptoflex Vario hygienic interface flush pressure transmitter for food, pharmaceutical and bioengineering industries. It adopts ceramic capacitive sensing element, supports CIP/SIP in-place cleaning and sterilization, and features IO-Link digital communication. It is the main product for pressure measurement on hygienic tanks and pipelines.

  1. Core Design Principle
  2. Flush dead-space-free ceramic diaphragm: 99.9% alumina ceramic wetted diaphragm without recess dead zone, prevents buildup of viscous materials and pharmaceutical liquids. The diaphragm resists vacuum impact and corrosive media. Wetted housing is made of 1.4435 (316L) stainless steel with surface finish meeting hygienic requirements.
  3. Aseptoflex Vario modular interface: Unified G1 male thread on sensor body. It can be fitted with various hygienic adapters to quickly convert to Tri-clamp, Varivent or welding base. Common sensor body reduces spare part inventory, max tightening torque 35 Nm.
  4. Ceramic capacitive measuring cell: Good long-term stability and overpressure resistance. Overall accuracy ≤±0.2%FS (linearity + hysteresis), repeatability <±0.1%FS, optimized temperature compensation for rapid temperature change during CIP/SIP.
  5. General Technical Specifications (Common for the whole series)
ArticolCaietul de sarcini
Alimentare electricăDC 18~30V, built-in reverse polarity protection
Ieșire4…20mA scalable analog + 1 PNP switching output + IO-Link
Temperatura medie-25~125℃ continuous; short-time peak 150℃ (max 1h for SIP sterilization)
Temperatura ambiantă-25~85℃
Electrical ConnectorM12 A-coded 4-pin gold-plated connector
Clasa de protectieIP67 / IP69K, withstand high-pressure spray cleaning
Wetted Parts MaterialDiafragmă: 99.9% Al₂O₃ ceramic; Locuințe: 1.4435 (316L) oţel inoxidabil; Sigiliu: EPDM
Zero CalibrationOn-device push-button teach or remote zero calibration via IO-Link
Additional DataIO-Link can read sensor housing temperature and diagnostic information
  1. Popular Models & Measuring Ranges (PM17 Series)

PM1704: -1 … 10 bar (ecartament)

PM1705: -1 … 4 bar (ecartament)

PM1707: -0.05 … 1 bar (-50~1000 mbar)

PM1708: -0.01 … 0.1 bar (-10~100 mbar, joasă presiune)

PM1714: 0 … 16 bar (ecartament)

PM1717: -0.1 … 1.6 bar

PM1718: Low pressure version (inH₂O unit)

PM1789: Ultra-low pressure (inH₂O, suitable for hydrostatic tank level measurement)

Regula de denumire a modelului: `PM-Range-REA01-E-ZVG/US`

REA01: G1 Aseptoflex Vario hygienic interface

E: IO-Link enabled

ZVG/US: Conector M12 cu 4 pini

  1. Hygiene Certifications

EHEDG, 3-O, FDA, EC1935/2004, ACS, cULus, UKCA; factory calibration certificate available for free download online.

  1. Avantajele produsului

✅ Modular hygienic adapter system: One sensor body can be fitted with different process adapters for multiple hygienic connections, easier project selection and spare parts management.

✅ Multi-function IO-Link: Remote scaling of 4-20mA range, set switch points, read pressure/temperature, diagnosticarea defecțiunii, backup pentru parametri; less interference compared with analog signals.

✅ Flush diaphragm without dead volume: Suitable for yoghurt, gem, suspension liquid and fermentation broth; no residual dead space for CIP cleaning.

✅ IP69K high-pressure washdown: Sensor housing can be directly flushed with cleaning fluid for routine food plant sanitation.

✅ Long service life: Switch capacity up to 100 million pressure cycles, ceramic cell with minimal drift.

  1. Scenarii tipice de aplicare

Ingredient tanks and fermentation tanks in food & băutură, emulsification processes; pharmaceutical preparation systems, purified water pipelines; bioreactors; hygienic pipeline pressure and hydrostatic level measurement.

  1. Instalare & Note de întreținere
  2. Max tightening torque 35 Nm. Over-torque will crack ceramic diaphragm.
  3. Do not scratch or hit diaphragm; after installation, diaphragm surface must be flush with tank inner wall to avoid material accumulation.
  4. Avoid rapid heating/cooling during SIP sterilization to prevent thermal shock damage to ceramic components.
  5. Periodically inspect EPDM seal aging; clean diaphragm surface if medium crystallization or material adhesion causes pressure drift.
  6. Comparison with Similar Series
  7. PM17 vs PM16: PM17 = Aseptoflex Vario hygienic modular G1; PM16 = standard G1 thread without Vario hygienic sealing, lower hygiene rating.
  8. PM17 vs PI17: PI17 shares the same interface and supports medium temperature measurement; PM17 can only read sensor housing temperature, cannot measure medium temperature.
  9. PM17: Pressure transmitter; PM11: Integrated Tri-clamp version (without Vario adapter system).
  10. Defecte comune
  11. 4-20mA stuck at full scale: Diaphragm rupture due to overload, wiring short circuit.
  12. Slow pressure drift: Aged sealing ring, medium crystal deposits on diaphragm, repeated severe thermal shock.
  13. IO-Link communication failure: Insufficient power supply, oxidized M12 pins, incorrect baud rate setup of IO-Link master.

Application Cases of IFM PM17 Series Hygienic Pressure Sensors

Core strengths of PM17: flush dead-space-free design, Aseptoflex Vario modular hygienic interface, CIP/SIP compatibility, IO-Link, IP69K. All cases are for hygienic processes in food & băutură, pharmaceutical and bio-industry, for tank pressure, pipeline pressure and hydrostatic level measurement.

Caz 1: Dairy Plant – Pressure & Hydrostatic Level on Yogurt / Cream Batching Tank

Selected Model: PM1704 (-1~10 bar)

Condiție de lucru: Viscous yoghurt and cream tend to stick and accumulate. Tanks undergo daily CIP cleaning and periodic SIP steam sterilization (135~150℃).

Instalare: G1 Aseptoflex Vario + welding base, flush diaphragm level with tank inner wall, no dead space for medium retention.

Measurement Target: Vapor phase pressure monitoring inside tank + continuous hydrostatic liquid level calculation. 4-20mA signal to PLC, remote zero calibration via IO-Link.

Puncte durere rezolvate:

  1. Traditional sensors with pressure port trap milk residue and cause drift; PM17 flush ceramic diaphragm leaves no residue after CIP cleaning.
  2. PM17 is compensated for rapid temperature variation during SIP thermal cycling, maintaining accuracy ≤±0.2%FS.
  3. IO-Link reads sensor diagnostics to detect seal aging and diaphragm crystallization in advance, reducerea timpului de nefuncţionare.

Logica de interblocare: High tank pressure alarm, vacuum protection, high/low level interlock for feed/discharge valves.

Caz 2: Beer Brewing – Fermenter Tank Pressure Monitoring

Selected Model: PM1705 (-1~4 bar)

Condiție de lucru: CO₂ generated during fermentation; stable slight positive pressure inside tank required. Periodic CIP spray cleaning.

Measurement Target: Maintain constant head pressure of fermenter to suppress microbes and control fermentation rate.

Repere:

Ceramic diaphragm withstands vacuum impact during exhaust evacuation without damage. Aseptoflex adapter can be quickly replaced; same sensor body can switch to Tri-clamp base.

Nota: If both pressure AND medium temperature measurement are required, select PI17 series with same interface; PM17 only reads housing temperature.

Caz 3: Pharmaceutical Formulation System (Biopharma / Injectable Preparation Tank)

Selected Model: PM1717 (-0.1~1.6 bar)

Condiție de lucru: Aseptic formulation tank, buffer preparation tank, SIP 121℃ steam sterilization, mediu: pharmaceutical liquid, purified water, high cleanliness requirement.

Conformitate: EHEDG, 3-O, FDA, EC1935/2004 certifications, factory calibration certificate downloadable online for GMP audit trail.

Aplicație: Tank pressure monitoring, vacuum leak test, hydrostatic level; IO-Link parameter backup, traceable batch data.

Beneficiul cheie: Wetted parts:1.4435 oţel inoxidabil + alumina ceramic, no silicone fill fluid to eliminate risk of pharmaceutical contamination. IP69K for high-pressure workshop washdown.

Caz 4: CIP Differential Pressure Protection for Food Heat Exchanger (Dairy UHT Ultra-high Temperature Sterilization)

Selected Model: PM1704

Proces: Plate heat exchanger for UHT. Product side pressure must be higher than thermal medium side pressure to prevent cross-contamination by medium leakage.

Soluţie: Two PM17 sensors mounted on product pipeline and heat medium pipeline respectively; PLC calculates differential pressure.

Interblocare: Automatically cut off feed and trigger alarm once product side pressure drops below threshold, protecting entire production batch.

Avantaj: Ceramic sensing cell resists water hammer impact; instantaneous pressure spikes from fast valve switching do not cause permanent zero drift.

Caz 5: Fruit Juice / Jam Production – Pipeline Pressure for High-Solid Viscous Media

Selected Model: PM1704

Condiție de lucru: Concentrated jam, fruit pulp with fruit particles, prone to clogging impulse lines.

Difficulty: Conventional pressure transmitters have impulse cavities easily blocked by fruit pulp and require frequent disassembly & curatenie.

PM17 Solution: Flush diaphragm contacts medium directly, no impulse dead cavity, solid particles cannot get stuck. IP69K, pipeline outer wall can be high-pressure washed.

Monitoring Target: Screw pump outlet pressure, pipeline blockage detection; pump protection triggered by pressure rise.

Caz 6: Purified Water / WFI Pipeline Pressure Monitoring (Pharmaceutical Water System)

Selected Model: PM1707 (-0.05~1 bar, low pressure range)

Condiție de lucru: Low-pressure continuous circulation of WFI water for injection, requires high accuracy low pressure measurement.

Caracteristici: Low-range PM1707 suitable for low-pressure clean water loop; ceramic diaphragm resists purified water corrosion with no leaching risk.

Caz 7: Bioreactor (Cell Culture Tank)

Selected Model: PM1717

Condiție de lucru: Slight positive pressure inside tank to prevent microbial ingress; periodic SIP sterilization.

Utilizare: Tank pressure regulation, overpressure protection, hydrostatic liquid level; IO-Link upload pressure and sensor diagnostic status to SCADA.

✅ Selection & Application Matching Table

Scenariul aplicațieiModel recomandatKey Reason
Batching tanks, viscous media like jam & yoghurtPM1704-1~10 bar range, flush diaphragm prevents material buildup
Slight positive pressure in beer fermentersPM1705-1~4 bar, vacuum impact resistant
Aseptic pharmaceutical formulation tanks, cell culture tanksPM1717-0.1~1.6 bar, complete hygienic certifications
Low-pressure WFI purified water loopPM1707-50~1000 mbar high accuracy low pressure
High pressure for solid-containing slurry pump outletPM17140~16 bar high pressure version

⚠️ General On-site Application Precautions

  1. Installation torque ≤35 Nm; over-torque will crack ceramic diaphragm.
  2. Avoid rapid temperature rise/fall during SIP sterilization to prevent thermal shock.
  3. Medium crystallization and protein adhesion will cause zero drift; match CIP cleaning formulation.
  4. Remote zero calibration via IO-Link without opening housing, great advantage for clean rooms.
  5. Flexible Aseptoflex Vario adapter: same sensor body can be fitted with welding base, Tri-clamp or Varivent connection, reducing spare part SKUs.

Prev: