KRAUS&NAIMER CA10.WAA345EF Switch

Model Code Interpretation Code Segment Description CA10 Basic series code: Mărimea S0 (48×48 mm) universal cam switch, side-mounted screw terminals, suitable for shallow installation depth, rated thermal current 20A . Separator to distinguish basic model and functional configuration W Mounting type: Montare standard pe panou (48mm cutout) AA Cam configuration code: Dedicated contact switching logic (4-pole 2-position, ...

  • Detalii despre produs

Interpretarea Codului Modelului

Segment de codDescriere
CA10Basic series code: Mărimea S0 (48×48 mm) universal cam switch, side-mounted screw terminals, suitable for shallow installation depth, rated thermal current 20A
.Separator to distinguish basic model and functional configuration
WTip de montare: Montare standard pe panou (48mm cutout)
AACam configuration code: Dedicated contact switching logic (4-pole 2-position, 60° rotation angle)
345Auxiliary function code: Equipped with specified auxiliary contact layout
EFActuator/handle type: Black plastic knob, IP40 protection degree
  1. Specificații tehnice de bază
CategorieDetailed ParametersObservații
Parametrii de bază
Marca / OrigineKraus & Naimer / AustriaBlue series switch, founded in 1907
Switch TypeCam change-over switchStructură modulară, double-break silver alloy contacts
DimensiuneS0 (48×48 mm)Standard panel mounting size
Modul de instalarePanel mounting with depth adaptationSide wiring to save installation space
Parametrii electrici
Rated Insulation Voltage Ui690V AC/DCRespectați IEC 60947-3
Rated Operational Voltage Ue400V și (3-fază), 230V și (monofazat)
Rated Thermal Current Ith20OContinuous working current rating
Rated Operational Current Ie20O (AC-15, 220-240V)Pentru sarcini rezistive
Rated Operational PowerAC-23A: 7.5kW (3×380-440V)Motor load capacity
AC-3: 5.5kW (3×380-440V)
Short-circuit Withstand Capacity10kA/1s @ 400V
Parametri mecanici
Polonii4P (4 stâlpi)
Operating Positions2 positionsNo neutral middle position
Rotation Angle60°Switching angle between two positions
Durata de viațăMecanic: 1,000,000 operațiuni
Electric: 10,000 operațiuni (under rated load)
Tip de contactRigid double-break silver alloy contactHigh conductivity and arc erosion resistance
Metoda de cablareSide screw terminalsCaptive screws with clamping plates
Clasa de protectieIP40 (front panel)Solid foreign object resistance per IEC 60529
Parametrii de mediu
Temperatura de operare-25°C ~ +55°CInstant peak up to +60°C
Temperatura de depozitare-40°C ~ +85°C
Ambient Humidity≤95% (necondens)
Installation Altitude≤2000mDerating is required beyond this altitude
  1. Defecte comune & Ghid de întreținere

3.1 Fault Troubleshooting Table

Fenomen de eroareCauze posibileTroubleshooting Procedures
Switch fails to shift1. Blocaj mecanic1. Cut off power and check knob flexibility
2. Cam abrasion2. Disassemble to inspect cam assembly and springs
3. Internal spring failure3. Remove foreign substances inside the switch
Poor contact performance1. Contact oxidation / ablation1. Test contact resistance (<50mΩ)
2. Borne de cablare slăbite2. Retighten terminal screws
3. Insufficient contact pressure3. Replace contacts if wear exceeds 1mm
Overload tripping1. Actual load exceeds rated value1. Verify load matching with switch rating
2. Rezistență de contact excesivă2. Clean or replace defective contacts
3. Temperatura ambientală excesiv de ridicată3. Optimize ventilation and heat dissipation
Insulation failure1. Excessive dust accumulation1. Power off and clean internal dust
2. Aging insulation components2. Check cracks on insulation parts
3. Cablaj incorect3. Re-wire strictly according to wiring diagram

3.2 Recomandări de întreținere

  1. Inspecție zilnică

Check knob operating flexibility monthly

Fasten wiring terminals quarterly (cuplu: 2.5Nm)

Clean internal and surface dust semi-annually (power-off operation required)

  1. Periodic Maintenance

Inspect contact wear annually and replace contact assembly if needed

Check cam and spring conditions every 2 ani, replace aging parts

Conduct insulation resistance test every 3 ani (≥100MΩ)

  1. Replacement Cycle

Normal working condition: Durata de viata mecanica 1,000,000 ori, viata electrica 10,000 ori

Severe environment (praf / umed / temperatură ridicată): Shorten replacement cycle by 50%

  1. Partial CA10 Series Model List
ModelPoloniiPozițiiRotation AngleMain Application
CA10.A007.FT21P260°Single-circuit power switching
CA10.A200.FT11P260°Basic on-off control
CA10.A210-600FT23P260°Motor start-stop control
CA10.A291-600FT24P260°Main power isolation switch
CA10.WAA345EF4P260°Equipment main power control (modelul actual)
CA10.PC6085-33P345°Star-delta starting control
CA10.A710-600E3P260°Motor forward/reverse switching

Complete Naming Convention

CA10.[Mounting Code][Cam Code][Auxiliary Code][Actuator Code]

Mounting Code: W=Standard Panel, V=Vertical Mount, F=Front Mount

Cam Code: AA, A007, A200, A210 etc. (define contact logic)

Auxiliary Code: 345, 600, 750 etc. (contacte auxiliare & special functions)

Actuator Code: EF=Black Knob, FT=Lockable Knob, GBA=Key Operated

  1. Cross-brand Product Comparison
MarcaModelCurent nominalPolonii / PozițiiDiferențele de bazăSuitable Application
Kraus & NaimerCA10.WAA345EF20O4P / 2-poziţieSide wiring, shallow installation depthSpace-limited control cabinets
SchneiderK1C003NCHC20O4P / 2-poziţieFront wiring, modular structureStandard cabinet installation
ABBOT16F416O4P / 2-poziţieSpring-loaded contacts, fast switchingFrequent operation occasions
Siemens3LD2100-0TK5320O4P / 2-poziţieBuilt-in auxiliary contacts & diagnostic functionHigh-level automatic control systems
EatonA22-200-40020O4P / 2-poziţieCost-effective economical designMass installation & budget projects

Puncte cheie ale selecției

  1. Modul de cablare: KN CA10 adopts side wiring to save installation depth, ideal for compact layout
  2. Material de contact: All adopt silver alloy contacts; KN double-break design offers stronger breaking capacity
  3. Durata de viață: KN mechanical life reaches 1,000,000 ori, superior to most peer products
  4. Certificari: All conform to IEC 60947-3 with CE and UL approvals
  5. Conformitatea transportului aerian & Documente de certificare

6.1 Air Transportation Compliance

Compliance ItemCaietul de sarciniOfficial Basis
Hazardous Goods ClassificationNon-hazardous goods, no built-in lithium battery / super capacitorIATA DGR 2026 Special Provision 9
Shipping PackageStandard industrial packaging, stackable and shock-resistantIATA DGR 8.1.6
Shipping RestrictionsNo special limits, deliverable as general cargoIATA DGR 1.1.3.2
UN NumberUN number is not requiredNon-dangerous commodity

6.2 Informații de certificare

Certificate TypeStandard executivCertificate No.Applicable Region
CE CertificateIEC 60947-3, ÎN 60947-3KN-CA10-CE-001EU & European Economic Area
UL CertificateUL 98, UL 508E257568North America
VDE CertificateVDE 0660 Parte 10740000123Germania & European markets
RoHS Certificate2011/65/EUKN-RoHS-2026Global eco-friendly markets
CCC CertificateGB 14048.3CCC-KN-007Chinese mainland market
  1. Aplicație & Ghid de selecție

Scenarii aplicabile

  1. Automatizare industrială

Controlul motorului: Direct start and stop control for small motors (≤5,5kW)

Comutarea puterii: Equipment main power on/off and standby power switching

Comutarea semnalului: Control circuit signal selection and test equipment signal switching

  1. Building Electrical Engineering

Zoned control of large lighting systems

Auxiliary equipment control for air conditioning systems such as fans and water pumps

Power supply control for alarm devices and monitoring systems

  1. Noua industrie a energiei

Combiner box power switching for photovoltaic systems

Charge and discharge control for energy storage battery packs

Load switching and protection for small generators

Non-recommended Usage Scenarios

  1. Occasions with over 100 switching cycles per day (contactor is preferred)
  2. Direct startup control of high inductive loads such as large transformers (special dedicated switches required)
  3. Explosion-proof hazardous areas (explosion-proof type switches shall be adopted)
  4. Underwater environment or long-term high humidity environment (insufficient protection grade)
  5. Informații de comandă

Model de produs: CA10.WAA345EF

Minimum Order Quantity: 1 piece

Lead Time: 7-10 working days for standard models; 15-20 working days for special customized models

Standard de ambalare: Single inner carton, 10 pieces per outer carton

Perioada de garanție: 2 years under normal operating conditions

KRAUS&NAIMER Full Series Model Recommendation Guide

Mainstream models are classified into Control Switches, Isolating Switches and Special-purpose Switches, covering various current ratings, pole configurations and working conditions, all adopting brand mature high-performance double-break contacts and modular design concepts.

  1. CA Series (Controla & Load Switches, 10~32A)

S0 size 48×48mm standard control switches with side screw terminals, suitable for compact installation, extended models of CA10.WAA345EF.

ModelPolonii / PozițiiCurent nominalRotation AngleCaracteristici de bazăAplicație tipică
CA4.A230-600E1P / 2-poziţie10O60°Mini size, gold-plated contacts optionalComutarea semnalului, instrument control
CA10.A291-600FT24P / 2-poziţie20O60°Lockable knob for misoperation preventionEquipment main power safety switch
CA10.PC6085-33P / 3-poziţie20O45°Special star-delta camStar-delta starting for motors ≤5.5kW
CA10.A710-600E3P / 2-poziţie20O60°Forward/reverse dedicated camConveyor, water pump direction switching
CA20.A290-600E4P / 2-poziţie32O60°Higher current rating, double-break structureMain power control for large 3-phase equipment

Model Explanation Example: CA10.A291-600FT2

CA10: S0 outline size, 20A rated thermal current

A291: 4-pole 2-position cam logic, full-pole on-off

600: Standard auxiliary contact configuration

FT2: Lockable black knob to avoid accidental operation

  1. CG Series (Compact Heavy-duty Control Switches, 10~40A)

Same overall dimension as CA series, equipped with front wiring terminals, more convenient for standard control cabinet installation.

ModelPolonii / PozițiiCurent nominalModul de cablareAvantajele de bazăScenarii aplicabile
CG10.A200.FT11P / 2-poziţie10OFront wiringEasy installation and wiringSmall control cabinets, operare frecventă
CG10.A210-600FT23P / 2-poziţie10OFront wiringDedicated motor control camDirect start of motors ≤2.2kW
CG25.A290-600E4P / 2-poziţie25OFront wiringHigh current bearing, double-break designMedium equipment power control, 3-phase 4-wire system
CG40.A291-600E4P / 2-poziţie40OFront wiringHeavy-duty structure, long mechanical lifeHeavy equipment frequent start-stop control
  1. CH Series (Instrument & Precision Control Switches, 10~40A)

Specially developed for instrument measurement and precise signal switching, optional gold-plated contacts, applicable to low-current high-precision control occasions.

ModelPolonii / PozițiiCurent nominalTip de contactAplicația de bazăUnique Advantages
CH10.A007.FT21P / 2-poziţie10OAliaj de argintSingle-channel signal switching, instrument selectionUltra-low contact resistance, măsurare de înaltă precizie
CH10.A210-600E3P / 2-poziţie10OGold-plated (opțional)Voltaj & current switching, test equipmentAnti-corrosion, suitable for humid environment
CH20.A290-600E4P / 2-poziţie20OAliaj de argintMulti-functional instrument control, multi-way switchingDesign modular, expandable auxiliary contacts
CH40.A291-600E4P / 2-poziţie40OAliaj de argintIndustrial instrument main power, signal distributionExcellent insulation performance, fit for high-voltage measurement system
  1. KG Series (Safety Isolating Switches, 10~63A)

Enclosed safety isolating switches with excellent short-circuit resistance, preferred main switch and maintenance switch for machine tools and power distribution cabinets, conform cu IEC 60947-3.

ModelCurent nominalPoloniiClasa de protectieFuncția de bazăAplicație tipică
KG10.A001-60010O2PIP40Basic isolation functionSmall equipment power isolation, maintenance protection
KG16.A200-60016O3PIP40With built-in auxiliary contactsMachine tool main power, 3-phase motor isolation
KG20.A290-60020O4PIP40Full-pole isolation4-wire system power isolation, prevenirea șocurilor electrice
KG32.A291-60032O4PIP4010kA high short-circuit withstandMedium equipment main switch, distribution cabinet isolation
KG63.A290-60063O4PIP40Heavy-duty reinforced structureLarge industrial equipment main power, power distribution system

Repere în design de siguranță

  1. Forced breaking structure ensures reliable contact separation and eliminates arc risks
  2. Extra large isolation clearance beyond industry standard to improve operational safety
  3. Optional cabinet door interlock device to prevent live cabinet opening operation
  4. Seria de aplicații speciale

5.1 Explosion-proof Series (CA-Ex / CG-Ex / KG-Ex)

Typical Models: CA10-Ex.A290-600E, KG20-Ex.A291-600

Certificare: ATEX certified, applicable to Zone1/21 gas hazardous area and Zone2/22 dust hazardous area

Aplicație: Chemical, petroleum, natural gas, mining and other flammable and explosive industries

5.2 Dedicated DC Series (G20)

Typical Models: G20.1000, G20.2000

Tensiune nominală: DC 1000V / DC 1500V, curent nominal: 100A~2000A

Aplicație: Photovoltaic inverters, sisteme de stocare a energiei, electric vehicle charging piles

5.3 High-current L Series (350~2400A)

Caracteristici: Modular assembly, expandable auxiliary contacts, IP54 protection grade

Aplicație: Industrial main power distribution, large generator set power control

  1. Quick Selection Table by Application Scenario
Scenariul aplicațieiSeria recomandatăModel tipicParametri cheie
Controlul motorului mic (≤5,5kW)CA10 / CG10CA10.PC6085-33P/3-position, star-delta startup
Equipment main power switchCA10 / KG20CA10.WAA345EF / KG20.A290-6004P/2-position, 20O
Instrument signal switchingCH10CH10.A007.FT21P/2-position, gold-plated contact optional
Machine tool maintenance switchKG SeriesKG16.A200-6003-pol, lockable type, safety interlock
Photovoltaic & sistem de stocare a energieiG20G20.1000DC1000V, 100O evaluare
Explosion-proof working environmentCA-Ex SeriesCA10-Ex.A290-600EATEX certified, Zone1 applicable
  1. Note de selecție
  2. Potrivire curentă: Select switches according to AC-3 motor load standard, reserve 1.2~1.5 times current margin
  3. Selectarea stâlpilor: Choose 3-pole for pure 3-phase loads, 4-pole for 3-phase 4-wire system to realize neutral line breaking
  4. Modul de operare: Adopt lockable knob for frequent use to prevent misoperation; key-operated type for high-safety occasions
  5. Adaptarea mediului: Select IP65 high protection grade for damp sites; stainless steel shell type for corrosive environment
  6. General Naming Rule Summary
SerieBasic CodeMounting CodeCam CodeAuxiliary CodeActuator Code
CA/CG/CHCA10W=Panel / V=VerticalA291=4P/2-position600=Standard Aux. ContactEF=Black Knob / FT=Lockable Knob
KG SeriesKG20Fixed enclosed typeA290=4P/2-position600=Standard Aux. ContactMâner rotativ / key handle
Explosion-proof SeriesCA10-ExStandard mountingA290=4P/2-position600=Standard Aux. ContactExplosion-proof dedicated handle
DC G20 SeriesG20Panel mounting1000=100A ratingRotary operating handle

Prev:

Lasă un răspuns

Lăsaţi un mesaj