Mitsubishi HG-KN43J-S100 Servo Motor - Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

Mitsubishi HG-KN43J-S100 Servo Motor - Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor

PLC/

Mitsubishi HG-KN43J-S100 Servo Motor

Serie: HG-KN (Low-inertia compact, for MR-JE drive) | Putere nominală: 400W / 0.4kW | Non-brake standard type HG: Prefix for Mitsubishi AC servo motor KN: HG-KN low-inertia compact series (MR-JE platform) 43: 400W specification J: Shaft with keyway, no built-in brake S100: 17-bit absolute encoder (131072 pulses/rev, compatible with MR-JE) Brake-equipped variant in the same ...

  • Detalii despre produs

Serie: HG-KN (Low-inertia compact, for MR-JE drive) | Putere nominală: 400W / 0.4kW | Non-brake standard type

HG: Prefix pentru Mitsubishi Servomotor AC

KN: HG-KN low-inertia compact series (MR-JE platform)

43: 400W specification

J: Shaft with keyway, no built-in brake

S100: 17-bit absolute encoder (131072 pulses/rev, compatibil cu MR-JE)

Brake-equipped variant in the same series: HG-KN43BJ-S100 (B = electromagnetic brake)

✅ Key Electrical Specifications

Putere nominală: 400 W

Cuplu nominal: 1.3 N·m

Maximum Torque: 3.8 N·m

Viteza nominală: 3000 rpm

Viteza maxima: 5000 rpm

Tensiune de alimentare: AC200V (single/three-phase 200–240V)

Curent nominal: 2.6 O

Codificator: 17-putin absolut

Dimensiunea flanșei: 60×60 mm

Diametrul arborelui: φ19mm

Clasa de protectie: IP65 (standard oil seal fitted)

Greutate: Aproximativ. 1.8 kg

✅ Compatible Drives (MR-JE only)

MR-JE-40A (Puls / analog interface)

MR-JE-40B (SSCNETⅢ/H bus)

MR-JE-40C (CC-Link IE Field)

✅ Typical Applications

Conveyor lines, linear transfer modules, masini de gravat, utilaje de ambalare, small CNC, point-to-point positioning mechanisms. Suitable for applications requiring fast start-stop response with low inertia.

✅ Spare & Note de înlocuire

Not compatible with MR-J4 / MR-JN drives; exclusive to MR-JE series

Referințe alternative interne: Delta B3 400W, Inovance IS620 400W low-inertia models

Cabluri: Cablu de alimentare + encoder cable, dedicated MR-JE connector, not directly interchangeable with MR-J4

MR-JE Alarm Code List (for HG-KN43J-S100)

Two categories: AL.xx Fault Alarms (machine stop) and E□.x Warnings (no stop). AL alarms require power cycle or software reset; warnings normally clear automatically once root cause is removed.

  1. AL Fault Alarms (Commonly Used)
Alarm CodeAlarm NameCauza de bază & Depanare
AL.10SubtensiuneLow main circuit voltage; pierdere de fază, poor contact of contactor, insufficient power supply capacity, cabluri libere
AL.12RAM Memory ErrorInternal drive hardware failure; power cycle first. Repeated alarm → replace drive
AL.14Control Circuit ErrorInternal CPU / control board failure; replace drive if restart ineffective
AL.16Encoder Initial Communication Error 1Loose CN2 encoder cable / conector, EMI interference, deteriorarea codificatorului
AL.1EEncoder Initial Communication Error 2Encoder handshake failure on power-up; check cable, împământarea scutului, motor encoder
AL.1FEncoder Initial Communication Error 3Mismatched encoder version / model; HG-KN is dedicated for MR-JE, do not mix other motors
AL.20Encoder Communication Error 1Encoder wire break, poor contact or heavy EMI during operation
AL.21Encoder Communication Error 2Hardware failure of encoder
AL.25Absolute Position LostDead encoder battery or disconnected battery wire; homing required after reset (frequent alarm for S100 absolute encoder)
AL.24Main Circuit FaultShort circuit on U/V/W, motor earth leakage, failed power transistor
AL.30Regeneration FaultFast deceleration, inerție mare de sarcină; insufficient built-in regenerative resistor, broken resistor, incorrect PA02 parameter
AL.31Viteză excesivăActual speed exceeds limit; excessive electronic gear ratio, abnormal pulse command, defecțiune a codificatorului
AL.32SupracurentU/V/W short circuit, motor insulation breakdown, damaged drive IGBT
AL.33SupratensiuneDC bus voltage>400V; voltage rise by regenerative energy during deceleration, excessive input voltage
AL.35Command Pulse Frequency ErrorPulse frequency out of drive limit, wrong pulse wiring mode (diferenţial / colector deschis)
AL.36SSCNET Communication Error (JE-B)Lejer / sharply bent fiber optic cable, duplicated station number, bus interference
AL.37Parameter ErrorParameter out of range or conflicting parameter combination; restore factory settings for test
AL.39Sequence Program Error (Position Table)Wrong position table instruction or conflicting parameters
AL.45Main Circuit OverheatPoor drive heat dissipation, temperatura ambientala ridicata, blocked cooling fan
AL.46Supraîncălzirea motoruluiSupraîncărcare, continuous stall, brake not released, slabă disipare a căldurii
AL.47Cooling Fan FaultFan stuck or damaged
AL.50Position Excessive DeviationLarge gap between command and actual position; blocaj mecanic, cuplu insuficient, low gain
AL.51Vibration DetectedServo vibration / abnormal noise; excessive gain, mechanical resonance
AL.61Forced Stop AlarmEmergency stop EMG circuit open (hardware E-stop, immediate shutdown)
AL.86Network Communication Error (JE-C CC-Link IE)Faulty Ethernet cable, wrong IP, switch fault, bus disconnection
  1. E Warnings (No Shutdown, Display E□.x)
Warning CodeWarning NameDescriere
E6.1Forced Stop WarningEMG terminal open warning (not a hard fault; often masked in projects – short EMG on CN1/CN3 or mask by parameter)
E8.1Homing IncompleteAbsolute encoder without homing after power-up; operation allowed but origin reference lost
E9.1Battery WarningLow encoder battery voltage. Replace battery promptly to avoid AL.25
E0.1Software Positive LimitLSP software limit triggered
E0.2Software Negative LimitLSN software limit triggered
  1. Reset Rules
  2. AL faults: Remove fault condition then power off & on to reset; some alarms can be cleared via MR Configurator2 software
  3. E warnings: Clear automatically after condition recovered, power cycle usually unnecessary
  4. AL.25: Home return must be executed after alarm clearing
  5. High-Failure Reminders for HG-KN43J-S100

AL.25, E9.1: Absolute encoder battery related – most frequent faults

AL.16/1E/1F/20/21: CN2 encoder cable. Separate power cable and encoder cable routing; single-end shield grounding

AL.46: 400W motor is prone to overheat under heavy load or continuous low-speed operation

Mitsubishi MELSERVO Servo List (Motor + Potrivirea conducerii, 200V Mainstream, including HG-KN / MR-JE)

General Suffix Definition

B: Frână electromagnetică; J: Shaft with keyway; S100: 17-bit absolute encoder; S000: Encoder incremental

Drive suffix: A = Pulse / analogic; B = SSCNETⅢ/H fiber; C = CC-Link IE Field; G = CC-Link IE TSN (MR-J5)

⚠️ Series incompatibility: MR-JE motor cannot run on MR-J4/J5; MR-J4 motor cannot directly run on MR-J5

  1. MR-JE Economy Series (matches your HG-KN43J-S100, widely used cost-effective model)

Matched Motors: HG-KN (Inerție scăzută), HG-SN (Inerție medie)

MR-JE Drives

MR-JE-10A / 10B / 10C —— 0.1kW

MR-JE-20A / 20B / 20C —— 0.2kW

MR-JE-40A / 40B / 40C —— 0.4kW (for your motor)

MR-JE-60A / 60B / 60C —— 0.6kW

MR-JE-70A / 70B / 70C —— 0.75kW

MR-JE-100A / 100B / 100C —— 1.0kW

MR-JE-200A / 200B / 200C —— 2.0kW

MR-JE-300A / 300B / 300C —— 3.0kW

HG-KN Motors (Inerție scăzută, 3000rpm)

HG-KN13J-S100 (0.1kW), HG-KN23J-S100 (0.2kW), HG-KN43J-S100 (0.4kW), HG-KN63J-S100 (0.6kW), HG-KN73J-S100 (0.75kW), HG-KN102J-S100 (1.0kW), HG-KN202J-S100 (2.0kW), HG-KN302J-S100 (3.0kW)

Varianta cu frana: HG-KN□□BJ-S100

HG-SN Motors (Inerție medie, for fluctuating loads)

HG-SN102J-S100 (1.0kW), HG-SN202J-S100 (2.0kW), HG-SN302J-S100 (3.0kW)

Varianta cu frana: HG-SN□□BJ-S100

  1. MR-J4 High-Performance Series (Large installed base for legacy machines)

Matched Motors: HG-KR, HG-MR, HG-SR, HG-RR, HG-JR

MR-J4 Drives

MR-J4-10A/B/GF — 0.1kW

MR-J4-20A/B/GF — 0.2kW

MR-J4-40A/B/GF — 0.4kW

MR-J4-60A/B/GF — 0.6kW

MR-J4-70A/B/GF — 0.75kW

MR-J4-100A/B/GF — 1.0kW

MR-J4-200A/B/GF — 2.0kW

MR-J4-350A/B/GF — 3.5kW

MR-J4-500A/B/GF — 5.0kW

MR-J4-700A/B/GF — 7.0kW

Multi-axis drives: MR-J4W2-22B, MR-J4W2-44B (2-axă); MR-J4W3-222B (3-axă)

MR-J4 Motor Lineup

  1. HG-KR: Small low-inertia 50W~750W (HG-KR053, HG-KR13, HG-KR23, HG-KR43, HG-KR73)
  2. HG-MR: Ultra-low inertia for frequent start-stop 50W~750W (HG-MR053,13,23,43,73)
  3. HG-SR: Medium inertia 0.5~7kW (HG-SR52,102,152,202,352,502,702)
  4. HG-RR: Medium capacity ultra-low inertia 1~5kW (HG-RR103,153,203,353,503)
  5. HG-JR: Large low-inertia 0.5~55kW (Mainly for machine tools, imprimare, turnare prin injecție)
  6. MR-J5 New Flagship Series (CC-Link IE TSN, new project replacement for MR-J4)

Matched Motors: HK-KT (Inerție scăzută, replace HG-KR/KN), HK-RT (Inerție medie, replace HG-SR)

MR-J5 Drives

MR-J5-10A/B/G — 0.1kW

MR-J5-20A/B/G — 0.2kW

MR-J5-40A/B/G — 0.4kW

MR-J5-60A/B/G — 0.6kW

MR-J5-70A/B/G — 0.75kW

MR-J5-100A/B/G — 1.0kW

MR-J5-200A/B/G — 2.0kW

MR-J5-350A/B/G — 3.5kW

MR-J5-500A/B/G — 5.0kW

MR-J5-700A/B/G — 7.0kW

Multi-axis drives: MR-J5W2-G, MR-J5W3-G (2-axă / 3-axă, wiring saving)

MR-J5 Motors

HK-KT Low Inertia: HK-KT053W,13W,23W,43W,73W

HK-RT Medium Inertia: HK-RT103W,153W,203W,353W,503W,703W

  1. Discontinued Legacy Series (Piese de schimb & maintenance only, nu este recomandat pentru proiecte noi)
  2. MR-J3 + HF-KP / HF-SP (Largest legacy stock, eliminarea treptată)
  3. MR-E / MR-ES + HF-KN / HF-SN (Earlier economy type, incompatible with HG-KN)
  4. MR-J2S (Very old generation)
  5. Quick Selection Summary Table
Drive SeriesPoziționareMotor potrivitInterfață de autobuz
MR-JEEconomie, rentabilHG-KN / HG-SNPuls / SSCNETⅢ/H / CC-Link IE Field
MR-J4General high-performance (legacy stock)HG-KR/MR/SR/RR/JRPuls / SSCNETⅢ/H / CC-Link IE Field
MR-J5New flagship for new projectsHK-KT / HK-RTPuls / SSCNETⅢ/H / CC-Link IE TSN
  1. Note suplimentare
  2. 400V high-voltage versions: MR-J4(-4), MR-J5(-4), with corresponding high-voltage motors, generally used above 7kW
  3. Special types: LM linear motors, TM-RG/TM-RU torque direct-drive motors, selected separately
  4. Cable incompatibility: MR-JE, MR-J4, MR-J5 encoder connectors & pin assignments differ and cannot be swapped directly

Prev:

Lasă un răspuns

Lăsaţi un mesaj