OMRON NS8-TV00B-ECV2 Human-Machine Interface

Model Code Breakdown NS8-TV00B-ECV2 NS8: NS series, 8.4-inch programmable terminal HMI TV: TFT Color LCD 00: Model standard, without video input (TV01 = supports video module) B: Black bezel (model without “B”: light gray bezel NS8-TV00-ECV2) EC: Built-in Ethernet port V2: 2nd generation hardware version Cross reference within series: NS8-TV00B-V2 = No Ethernet; NS8-TV00B-ECV2 = ...

  • Detalii despre produs

Defalcarea codului de model

NS8-TV00B-ECV2

NS8: NS series, 8.4-inch programmable terminal HMI

TV: TFT Color LCD

00: Model standard, without video input (TV01 = supports video module)

B: Black bezel (model without “B”: light gray bezel NS8-TV00-ECV2)

EC: Port Ethernet încorporat

V2: 2nd generation hardware version

Cross reference within series: NS8-TV00B-V2 = No Ethernet; NS8-TV00B-ECV2 = Standard equipped with Ethernet

  1. Specificații hardware de bază
ArticolParametru
Afişa8.4″ TFT Color LCD, Resolution 640×480(VGA)
Display Colors65,536 culorile (16-pic)
Atingeți TipAnalog Resistive Touch Screen
Alimentare electricăDC24V (Interval admisibil:20.4~27.6V), Max power consumption ≤18W
Memoria programului60 MB
Interfețe✅ 10/100BASE-T Ethernet
✅ Dual RS232C (DB9)
✅ USB Slave (Program Upload/Download)
✅ USB Host (USB Flash Drive / Mouse)
Front ProtectionIP65 / NEMA4 (When properly sealed after panel mounting)
Temperatura de operare0~50℃; Storage Temperature -20~60℃ (No condensation)
Dimensiuni generale315(W) × 241(H) × 48.5(D) mm
Panel Cutout Dimensions298 × 224 mm
BacklightCCFL Cold Cathode Fluorescent Lamp (Durata de viata aprox. 50,000 ore; yellowing and dimming will occur after aging)
  1. Software Information

Software de programare: NS-Designer Ver.6.X

Protocoale de comunicare: OMRON Link gazdă, FINS Ethernet. Compatible with CJ/CS/CP1H/CP1E series PLCs; also supports Modbus RTU/TCP

⚠️ Not compatible with Sysmac Studio; cannot directly replace NA/NJ series HMI

  1. Product Lifecycle Notice

✅ Official End of Production (EOP)

Available supply: New surplus stock and used refurbished units; spare part prices keep rising.

Soluții de înlocuire

  1. Direct in-place replacement (Preferat, compatible mounting cutout)

NA8-12W101-V2 (8.4-inch NA series; wide screen, note resolution difference, screen project needs full redesign)

  1. Minimum program modification migration solution

Used NS8-TV00B-ECV2

  1. Alternative interne: Weinview, Kinco 8-inch HMI; requires full screen redrawing and communication debugging.
  2. Defecte comune & Pitfall Reminders
  3. Typical failure: CCFL backlight aging leading to black screen. Backlight strip replacement or LED backlight modification is feasible.
  4. Touch malfunction: Touch panel aging; independent replacement touch glass available for purchase.
  5. Ethernet communication failure: The Ethernet chip of ECV2 model is vulnerable to electrostatic damage. Surge protection is recommended for communication cables.
  6. Program compatibility: Projects developed for V2 hardware cannot be opened directly on early V1 units.
  7. Ordering distinction: Do not confuse NS8-TV00B-V2 (No Ethernet) and ECV2 (Cu Ethernet).
  8. Aplicații tipice

Masini-unelte, utilaje de ambalare, injection molding equipment, linii de transport, retrofitting projects equipped with classic OMRON PLCs (CP1H, CJ1M, CS1G).

If needed, I can supplement:

CAD text of panel cutout dimensions

Rear interface pin assignment definition

Step-by-step guide for FINS Ethernet communication setup via NS-Designer

Simple operation guide for backlight modification

Programming Software for OMRON NS8-TV00B-ECV2

  1. Software Evolution

This unit belongs to NS Series V2 Hardware (-ECV2)

  1. Original standalone software: NS-Designer (Max Version V6)
  2. Later integrated software: CX-Designer

✅ CX-Designer is widely adopted currently

CX-Designer is integrated into the CX-One software suite, CX-One installation is prioritized.

  1. Version Selection Recommendation
  2. CX-One 4.0 / 4.1 (Most stable, widely used in industrial automation)

Built-in CX-Designer, fully compatible with NS8-TV00B-ECV2.

  1. Newer CX-One 4.2/4.3 are also compatible, but compatibility mode configuration is required under Win10/Win11.
  2. ❌ Sysmac Studio is NOT supported!

Sysmac Studio only supports NA/NJ/NX series; it cannot work with legacy NS touch screens.

  1. Project File Formats

Source project file: `.ipp`

Compiled file downloaded to HMI: `.tsp`

  1. Note importante
  2. Old NS-Designer projects can be opened and converted directly with CX-Designer; reverse conversion is not available.
  3. Program download methods: Ethernet(FINS), USB-B cable, RS232 serial port.
  4. NS8-TV00B-ECV2 is V2 hardware; select exact model NS8-TV00B-ECV2 in software, avoid selecting V1 version.
  5. HMI firmware upgrade can be performed within CX-Designer.
  6. Common Confusion Reminder

Many users mix up different software:

NB series HMI → NB-Designer

NA/NJ new generation → Sysmac Studio

Legacy NS touch screen → CX-Designer (CX-One Suite)

If needed, pot oferi:

Procedures for downloading HMI projects via FINS Ethernet

CX-One compatibility settings guide under Win11

Operation process for program upload and decryption

Full List of Supported Communication Protocols for OMRON NS8-TV00B-ECV2

Hardware Interfaces: Dual RS232C (Port A / Port B; Port B switchable to RS422/485) + Ethernet RJ45 încorporat + USB Host + USB Slave

Software: CX-Designer (CX-One Suite). All protocols can be selected in [Setări de comunicare] of project.

  1. Protocols for Ethernet Port (Built-in on ECV2)

For connecting OMRON PLC, program download and PC host communication

  1. FINS Ethernet (UDP/TCP) [Primary Protocol]

For CJ1M/CJ2M/CS1G/CP1H/CP1E OMRON PLCs, cel mai des folosit.

  1. Modbus TCP (Maestru)

Direct connection to Modbus TCP instruments and third-party PLCs.

  1. Controller Link (Ethernet routing)
  2. Memory Link (Ethernet)

Data exchange with custom PC host software.

  1. Serial Port Protocols (RS232C / RS422/485)

✅ OMRON native protocols (For OMRON PLC connection)

  1. NT Link 1:1 / NT Link 1:N (High-speed serial)

Compatible with CJ/CS/CP1H series (Classic serial communication for NS series)

  1. Link gazdă (1:1)

Legacy OMRON PLCs: CVM1, C200H, CPM1A, etc.

  1. CompoWay/F

Direct connection to OMRON temperature controllers E5CC/E5AZ and sensors, no PLC forwarding required.

✅ Standard Industrial Protocols

  1. Modbus RTU (Maestru)

Frequency inverters, instrumente, third-party PLCs (Only RTU supported, Modbus ASCII is not supported)

  1. Memory Link (Serial)

Serial data exchange between PC host and HMI.

✅ Third-party PLC Serial Protocols

Mitsubishi: Protocolul MC (3C/4C Frame) → FX/Q Series

Rockwell AB: DF1 Protocol

GE Fanuc: SNP-X Protocol

Siemens: Siemens 3964(R)/RK512 (S5/Old S7 serial, S7 Ethernet is not supported)

⚠️ Critical Limitation: Native S7 TCP / Profinet / CC-Link are unavailable. Cannot connect S7-1200/1500 directly via Ethernet; Modbus TCP gateway is required for communication with new Siemens PLCs.

  1. USB Port Functions (Cannot be used for PLC communication, only peripheral connection & descărcarea programului)
  2. USB Slave (Type-B): Connect PC CX-Designer for program upload/download
  3. USB Host (Type-A): USB flash drive (Înregistrarea datelor, program import), USB printer, mouse

❌ USB cannot communicate with PLC

  1. Key Engineering Pitfall Notes
  2. Port A and Port B can run different protocols simultaneously, enabling one HMI to connect two sets of equipment independently.
  3. NS8-TV00B-ECV2 only works as Communication Master, cannot act as Slave. It cannot be read/written actively by external PLCs.
  4. Ethernet port and serial ports support parallel communication at the same time.
  5. Firmware version affects protocol stability: Upgrade HMI system firmware to V8 or above for better reliability of third-party protocols.
  6. EtherNet/IP, OPC UA, Profinet are not supported natively.
  7. Distincţie: NS series protocols are incompatible with NA/NB series.

Recommended Communication Schemes

  1. OMRON CJ/CP Series PLC → FINS Ethernet (Prima alegere)
  2. Multiple E5CC Temperature Controllers → CompoWay/F (RS485)
  3. Inverters & General Instruments → Modbus RTU (RS485) or Modbus TCP
  4. Mitsubishi FX Equipment Retrofit → MC Protocol (Serial)

If needed, pot oferi:

Complete configuration steps for FINS Ethernet communication

Wiring diagram and CX-Designer parameter template for Modbus RTU

Configuration points for dual serial ports driving multiple devices concurrently

Supported Operating Systems for CX-Designer (Matching NS8-TV00B-ECV2)

CX-Designer is embedded within the CX-One software suite. All descriptions below apply to widely deployed CX-One V4.x (CX-Designer V3.x) — the stable version for editing NS series HMI projects.

  1. Officially Supported Operating Systems

✅ Officially validated & recomandat

  1. Windows 7 (32pic / 64pic; Professional / Enterprise / Ultimate Edition)
  2. Windows 8.1 (32pic / 64pic; System patch KB2919355 installation required)
  3. Windows 10 (32pic / 64pic; Pro / Enterprise / LTSC all compatible)
  4. Windows 11 (Only 64bit. No official certification; verified operable in practice, compatibility mode configuration mandatory)

❌ Officially Unsupported

Windows XP, Windows Vista: Only compatible with legacy CX-Designer V2. Not recommended for NS8-TV00B-ECV2 project editing, risk of corrupted projects and firmware download failures.

Original Windows 8: Poor compatibility, not recommended by OMRON.

All Windows Server systems (Server2016/2019 etc.): No official guarantee; partial environments may run with instability.

  1. Practical Operation Tips for Different OS (Industrial Site Pitfall Avoidance)

1) Windows7 64bit

⭐ Preferred OS with maximum stability

Rarely encounter communication errors or upload/download failures; standard configuration for industrial field computers.

2) Windows10 64bit (LTSC 2019/2021 Recomandat)

Good compatibility; right-click installer → Run as administrator during installation.

După instalare: Configure CX-Designer shortcut: Compatibility Mode Windows7 + Rulați ca administrator.

3) Windows11 64bit

⚠️ Not officially certified, works under practical testing

Common risks: Intermittent disconnection during USB program download, unstable FINS Ethernet communication.

Two mandatory settings:

  1. CX-Designer shortcut → Properties → Compatibility Mode: Windows7
  2. Disable Memory Integrity (Windows Security → Device Security → Core Isolation)
  3. Important Restrictions
  4. No standalone 64-bit CX-Designer executable. The software is a 32-bit program running via WOW64 subsystem on 64-bit Windows.
  5. Avoid compact/green portable CX-One releases; high risk of connection failure to NS8-TV00B-ECV2 and project damage.
  6. MacOS, Linux: No native support. Only operable via virtual machine (VMware running Win7/Win10).
  7. Software boundary distinction:

CX-Designer: NS Series (NS8-TV00B-ECV2)

Sysmac Studio: NA/NJ/NX, Cannot open NS projects

  1. Minimum Hardware Requirements

Display Resolution ≥1024×768

Full CX-One installation: ≥4GB free hard disk space

RAM ≥4GB (8GB or higher recommended under Win10/Win11)