Phoenix Contact TRIO-PS-2G/3AC/24DC/20 Industrial Switching Power Supply - Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

 Phoenix Contact TRIO-PS-2G/3AC/24DC/20 Industrial Switching Power Supply - Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor

PLC/electric/

Phoenix Contact TRIO-PS-2G/3AC/24DC/20 Industrial Switching Power Supply

(Comanda nr.: 2903155) Phoenix Contact 2nd-generation TRIO POWER DIN rail mounted industrial switching power supply, 3-phase AC input, 24V DC/20A output, Dynamic Boost 30A for 5 secunde, Push-in tool-free spring terminals. Typically used for 24V power supply to PLCs, valve islands, sensors and solenoid valve banks in machine tools and automation control cabinets, well suited ...

  • Detalii despre produs

(Comanda nr.: 2903155)

Phoenix Contact 2nd-generation TRIO POWER DIN rail mounted industrial switching alimentare electrică, 3-phase AC input, 24V DC/20A output, Dynamic Boost 30A for 5 secunde, Push-in tool-free spring terminals. Typically used for 24V power supply to PLCs, valve islands, sensors and solenoid valve banks in machine tools and automation control cabinets, well suited for loads with inrush current.

✅ Model Decoding

TRIO-PS-2G: 2nd-generation TRIO POWER alimentare electrică

3AC: 3-phase AC input

24DC: 24V DC ieșire

20: Rated output current 20A

📋 Full Technical Specifications

Partea de intrare

Tensiune de intrare: 3×400~500V AC (toleranţă: -20% ~ +15%)

Frecvenţă: 50/60Hz

Hold-up time: >10ms @400VAC

Terminale: L1/L2/L3/PE, Push-in tool-free spring terminals

Input protection: Recommended upstream 3P 10A/16A type B circuit breaker

Partea de ieșire

Evaluat: 24În DC / 20O, 480W

Dynamic Boost: 30O, 5 secunde (for solenoid valves and motor inrush loads)

Adjustable output: 24~28V DC

Clipoci & zgomot: ≤20mVpp

Eficienţă: Typ. >93% @400VAC full load

Protecţie: Protecție la scurtcircuit, protectie la supracurent, overtemperature protection, OVP overvoltage protection (OVP limit ≤30V DC)

Semnal: DC OK relay dry contact (max.30V AC/DC,100mA) for PLC fault remote indication

Paralel / series operation: ✅ Multiple units can be paralleled for capacity expansion or redundancy; ✅ Can be connected in series for higher voltage

Mecanic & de mediu

Montare: Sina DIN standard de 35 mm

Dimensiuni: W65 × H130 × D160 mm

Greutate netă: Approx.1.5kg

Clasa de protectie: IP20 (instalarea dulapului)

Temperatura de functionare: -25℃ ~ +70℃; derating starts above 60℃ at 2.5%/K; cold start down to -40℃

MTBF: >1,800,000h @25℃ (IEC61709)

🛠️ Wiring Notes

  1. Intrare: 3-phase L1/L2/L3 + PE protective earth. The unit can still operate with phase loss, but DC OK signal will trigger an alarm.
  2. Ieșire: DC+ / DC-. Direct parallel connection with automatic current sharing, no extra current sharing wire required. For redundant systems, a decoupling diode module is recommended.
  3. DC OK: Passive relay contact. Closed when power supply healthy; opens upon power loss, fault or overtemperature, connected to PLC for fault diagnosis.

🔄 Upgrade & Înlocuire

  1. 2nd generation: TRIO-PS-2G/3AC/24DC/20 (2903155, modelul actual)
  2. 3rd generation upgrade: TRIO3-PS/3AC/24DC/20 (2186227). Pin-out and mounting dimensions fully compatible, improved EMC and reliability, direct drop-in replacement.

⚠️ Common Troubleshooting

  1. DC OK indicator off, nicio iesire

Check for missing phase, loose wiring or tripped upstream circuit breaker

Overtemperature protection activated: Check cabinet ventilation and ambient temperature

  1. Normal voltage at no-load, voltage drop under load

Verify reliable Push-in connection of output terminals; insufficient output cable cross-section

Confirm load does not continuously exceed 20A (Boost only lasts 5 secunde, cannot sustain 30A continuously)

  1. Protection trips immediately after power-up

Short circuit or ground fault on DC output side; isolate load and test power supply at no-load

📌 Application

Machine tool automation, linii de ambalare, metallurgy auxiliary control, large control cabinets, centralized power supply for PLC, valve islands, sensors and 24V solenoid valve banks. Boost function ideal for heavy inrush loads.

Comparison List of Domestic Replacements for TRIO-PS-2G/3AC/24DC/20 (2903155)

Key characteristics of original unit: 3-phase 3×400~500VAC input, 24V 20A/480W, 150% short-time Boost (30A/5s), DC OK relay alarm, Montare pe șină DIN, parallel redundancy support, adjustable 24~28V output, IP20, -25~70℃.

Nota: Meanwell is Taiwanese owned domestic brand; Inovance and Great Wall are mainland manufacturers. Meanwell TDR-480-24 is the preferred closest alternative.

MarcaModelInput SpecOutput SpecShort-time Boost
Meanwell (Taiwanese)TDR-480-243-phase 340~550VAC, 2-phase operation supported24V/20A,480W,24~28V adjustable150% limita curentului (30O),5s
Inovaţie (China continentală)MD800-PS-3AC400-24203-phase 340~550VAC24V/20A,480W150% peak for 5s
Great Wall Power (China continentală)DR960S series 3-phase 480W 24V20A3-phase 320~575VAC24V/20A,480W150% overload for 5s
Chuanglian Power (China continentală)CL-3AC480-243-phase 340~550VAC24V/20A,480W130% vârf (2~3s, cannot reach original 30A/5s)

📌 Key Selection Notes

  1. Boost is critical: Original Phoenix delivers 30A for 5 seconds for solenoid banks and motor startup. Chuanglian CL-3AC480-24 has insufficient peak current, not allowed for inrush loads.
  2. Terminal difference: Original Push-in tool-free; Meanwell TDR uses screw terminals requiring wiring modification; Inovance/Great Wall support optional Push-in terminals for minimal cabinet changes.
  3. Parallel redundancy:

Phoenix: Direct parallel of identical units with automatic current sharing

Inovance/Great Wall: Dedicated current sharing cable for better parallel performance

Meanwell TDR: Parallel possible, DR-RDN20 decoupling diode module recommended for fault isolation

  1. Temperature derating: Original starts derating >60℃; Inovaţie & Great Wall have similar curve; Meanwell TDR requires derating at full load near 70℃
  2. EMC: Phoenix EN61000-6-2 industrial immunity; Meanwell TDR and Inovance meet same EMC class, no extra filter required inside cabinet.

⚠️ Not Recommended Models

Single-phase power supplies (NDR/DR series): 220V single-phase input, cannot replace 3AC 3-phase models

Generic domestic 3-phase power supplies without DC OK relay: Doar indicator LED, no PLC fault alarm, not suitable for automation equipment.

📋 Modification Effort Assessment

  1. Minimal change: Inovance MD800-PS-3AC400-2420 (Push-in optional, similar dimension, matched parameters)
  2. Standard replacement: Meanwell TDR-480-24 (good stock, widely verified; only change from Push-in to screw terminals)
  3. Low-cost batch cabinet: Great Wall DR960S 3-phase variant for domestic system integration projects

Phoenix Contact TRIO-PS-2G (2nd Gen TRIO POWER) Lista completă a modelelor

Series common features: Montare pe șină DIN, Push-in spring terminals, dynamic Boost overload, DC OK relay dry contact, -25℃~+70℃ wide temperature, parallel for expansion/redundancy, standard for machine automation.

  1. Single-phase input 1AC (85~264VAC)
ModelComanda nr.Evaluare de ieșirePutereObservații
TRIO-PS-2G/1AC/24DC/3/C2LPS290314724V/3A72WWith C2LPS safety function
TRIO-PS-2G/1AC/24DC/5290314824V/5A120WStandard
TRIO-PS-2G/1AC/24DC/10290314924V/10A240WStandard
TRIO-PS-2G/1AC/24DC/20290315124V/20A480WStandard
TRIO-PS-2G/1AC/48DC/5290315948V/5A240W48V DC ieșire
TRIO-PS-2G/1AC/48DC/10290316048V/10A480W48V DC ieșire

Derivative B+D versions (built-in protection)

TRIO-PS-2G/1AC/24DC/5/B+D Order No.:2902144

TRIO-PS-2G/1AC/24DC/10/B+D Order No.:2902145

  1. 3-phase input 3AC (3×400~500VAC, your target series)
ModelComanda nr.Evaluare de ieșirePutereObservații
TRIO-PS-2G/3AC/24DC/5290315324V/5A120WSmall 3-phase
TRIO-PS-2G/3AC/24DC/10290315424V/10A240W3-fază
TRIO-PS-2G/3AC/24DC/20290315524V/20A480WYour target model
TRIO-PS-2G/3AC/24DC/40290315624V/40A960WHigh power 3-phase

📌 Selection Guide

  1. 1AC single-phase: Cabinet 220V supply; 3AC three-phase: Machine tools and large production lines with 380V cabinet input
  2. Boost capability: Toate modelele suport 150% short-time overload for 5s for solenoid and contactor inrush
  3. C2LPS: Safety power supply variant for PL/Cat safety circuits; standard projects use non-C2LPS
  4. B+D: Integrated DC-side electronic protection, may eliminate separate load protection module
  5. Replacement note: 2nd-gen TRIO-PS-2G phasing out; new projects prefer TRIO3 3rd generation

📎 Matching Accessories (Common for the series)

Redundancy module: TRIO-DIODE/12-24DC/20 (20A anti-reverse diode for redundant power)

Electronic circuit breaker: CBM series, 24V multi-channel load protection

Phoenix Contact Matching Product Recommendations (Control Cabinet Automation, matched with TRIO power supply)

Montare pe șină DIN, Push-in tool-free terminals, for machine tools and production line automation.

  1. Power system accessories (TRIO family, redundanţă & protecţie)
  2. QUINT POWER high performance power supply (high-end redundancy)

QUINT-PS/3AC/24DC/20, 3-phase 24V20A, predictive diagnostics and selective fuse breaking. First choice for non-stop critical equipment; higher grade than TRIO.

  1. Redundancy diode module (for dual TRIO power redundant setup)

TRIO-DIODE/12-24DC/20 (20O). Two TRIO power supplies in parallel, fault isolation to prevent reverse current from failed unit.

  1. CBM / CAPAROC electronic circuit breaker (24V branch protection)

CBM e4 24DC/0.5-10A NO-R, 4-channel adjustable electronic protection, alternative to fuses, fault alarm signal to PLC, standard for 24V sensor and valve island loops.

  1. UPS Uninterruptible Power Supply

QUINT-UPS/24DC/20, 24V DC UPS, maintains PLC and controller data retention during short mains dropout.

  1. Blocuri terminale (COMPLETE line PT series, Push-in)

PT2.5 (Order No.3209508): 2.5mm² general signal/power terminal, tool-free direct insertion, highest consumption in control cabinets

PT2.5-PE: Borna de pamant de protectie, green-yellow

PT6: 6mm² high-current terminal, power input wiring

Avantaj: Common FBST jumpers, uniform marking strips, same Push-in technology as TRIO power supply for fast wiring.

III. Releu / optocoupler isolation modules (PLC output driving solenoids & contactoare)

PLC-RSC-24DC/21 (Order No.2966171)

DIN rail pluggable relay module, 24VDC coil, 1NU+1NC; 6.2mm slim width, LED status indicator; replaceable relay cartridge, PLC IO isolation, suppress inductive load surge to IO points.

PLC-OPT-24DC/24DC/2: Optocoupler isolation module, no mechanical contacts, for high-frequency circuits.

  1. Surge protection devices (SPD, fulger & protecție la supratensiune tranzitorie)
  2. VAL-MS 230/2: Single-phase 220V AC Type 2 protectie la supratensiune, cabinet mains inlet protection
  3. VAL-MS 24DC: 24V DC side surge protection for sensors and fieldbus signals; hot-swappable module with remote alarm contact, fault feedback to PLC.
  4. Distributed I/O modules (Axioline series, fieldbus)

Axioline F / Axioline Smart Elements, Profinet, EtherCAT distributed I/O, IP20 cabinet mount; Terminale push-in, high density, compatible with Phoenix PLC and PC WORX software, for large production line distributed signal acquisition.

  1. Industrial Switches (FL SWITCH series)

COMUTATOR FL 1005, 5-port unmanaged industrial Ethernet switch; COMUTATOR FL 2008 managed switch, ring redundancy support, wide temperature DIN rail mount, widely used in Profinet/EtherCAT networks.

VII. Signal Isolators / Intrinsic Safety Barriers (Process instrumentation, analogic)

MACX MCR series isolation transmitters

4-20mA analog signal isolation, conversion and loop power supply; eliminates ground loop interference for pressure and temperature transmitters.

Explosion-proof application: MACX Ex intrinsic safety barriers for hazardous area instruments.

VIII. Relee de siguranță (Circuite de siguranță, oprire de urgență, porti de siguranta)

PSR series safety relay, PSR-SCP-24DC/ESD/5X1/1X2; for emergency stop buttons, safety doors and safety light curtains, PLd safety level, mandatory safety circuit for machine tools.

  1. Controllers PLC / IPC

ILC compact PLC: Compact DIN rail controller, PC WORX programming, onboard I/O, for small & medium standalone machines

RFC high-end PLC: Redundant controller, large production lines and critical equipment; Profinet, Modbus TCP acceptat

📌 Recommended Complete Cabinet Bill of Material (based on TRIO-PS-2G/3AC/24DC/20)

3-phase mains inlet → VAL-MS 3-phase surge protector → TRIO 24V power supply → TRIO-DIODE redundancy module (dual power option) → CAPAROC electronic circuit breaker → PT terminal blocks → PLC-RSC relay modules + Axioline I/O + FL switch + PSR safety relay

 

Prev:

Următorul:

Lasă un răspuns

Lăsaţi un mesaj