Model Code Breakdown Explanation Code Segment Definition MCR Base series identifier: Modular Current/Voltage Converter, series of 3-way isolated signal conditioners C Dimension specification: Standard width (17.5mm), differs from MINI MCR series (6.2mm/12.5mm) UI Input type: Universal Input, supports 0–10V voltage & 4–20mA current signals UI Output type: Universal Output, supports 0–10V voltage & 4–20mA current ...

  • Detalii despre produs
  1. Model Code Breakdown Explanation
Segment de codDefiniţie
MCRBase series identifier: Modular Current/Voltage Converter, series of 3-way isolated signal conditioners
CDimension specification: Standard width (17.5mm), differs from MINI MCR series (6.2mm/12.5mm)
UITip de intrare: Universal Input, supports 0–10V voltage & 4–20mA current signals
UITip ieșire: Universal Output, supports 0–10V voltage & 4–20mA current signals
DCIFunctional feature: DC Isolation; built-in DC/DC converter realizes 3-port isolation among Input / Ieșire / Alimentare electrică
2810913Număr unic de comandă: Official Phoenix part number for procurement & inventory management
  1. Core Specification Data Sheet

2.1 Basic Electrical Specifications

ParametruValoareRemarcă
Isolation Type3-way isolation (Intrare / Ieșire / Putere)Withstand voltage test: In-Out:1.5kV AC; Power-Signal:1kV AC (50Hz, 60s)
Input Signal0–10V DC / 4–20mA DCMax. intrare:30V / 50mA
Semnal de ieșire0–10V DC / 4–20mA DCMax. ieșire:15V / 30mA
Transmission Error≤0.1% FSHigh-precision signal conversion
Alimentare electrică18–30V DCNominal 24V DC; No-load current <30mA
Consumul de energie≤900mWUnder rated operating condition
Cut-off Frequency30Hz3dB point, effectively suppress high-frequency interference
Step Response11Domnișoară (10%–90%)Fast signal tracking performance

2.2 Mecanic & Environmental Specifications

ParametruValoareRemarcă
Dimensiunea de ansambluL17,5 mm × H99 mm × D114,5 mmDIN rail mounting for space saving
MontareSina DIN standard de 35 mmArbitrary installation orientation available
ÎncetareaTerminal cu șurub cu priză (COMBICON)Stripping length:8mm, M3 screw thread
Cable SizeSolid/Flexible:0.2–2.5mm² (AWG24–14)Compatible with various industrial cables
Temp. de operare.-20°C ~ +65°CWide temperature range for industrial environment
Ingress RatingIP20Indoor cabinet installation only
Greutate149.4g (cu pachet)Lightweight for easy mounting

2.3 Certificare & Conformitate

CertificareStandardRemarcă
CEÎN 61000-6-2 / ÎN 61000-6-4EMC compliant
UL RecognizedUL 508Class I Div.2 Groups A-D; Class I Zone2 Group IIC
Eco-certificateUE RoHS / China RoHSEFUP-50 (50-year service life for environmental compliance)
Cod HS85437090For customs clearance in international trade
  1. Full Series Part Number List (MCR-C-UI-UI-DCI Family)
Comanda nr.ModelCaracteristica specialăAplicație tipică
2810913MCR-C-UI-UI-DCIVersiune standard, factory preset 0–10V/0–10VGeneral industrial signal isolation & conversion
2810939MCR-C-UI-UI-DCI-NCNC = No CalibrationFixed application without on-site calibration
2811284MACX MCR-UI-UIUpgraded replacement modelNew generation with improved performance
2810915MCR-C-UI-UI-450-DCIHigh-load type, Max. output load ≤450ΩLong-distance signal transmission & high-load occasions
2810941MCR-C-UI-UI-450-DCI-NCHigh-load without calibrationHigh-load fixed installation without trimming
  1. Cross-reference: Învechit & Competitor Replacement List

4.1 Internal Phoenix Replacement

Model VechiModel de înlocuireUpgrade Highlights
MCR-C-UI-UI-DCI (2810913)MACX MCR-UI-UI (2811284)Narrower width(12.5mm), lower power draw, răspuns mai rapid
MCR-C-UI-UI-450-DCIMACX MCR-UI-UI-450Identical function with compact footprint

4.2 Cross-brand Equivalent Comparison

Modelul PhoenixEchivalentul SchneiderEchivalentul SiemensDiferențele de bază
MCR-C-UI-UI-DCI (2810913)FOXboro IMT25SITRANS P DS IIIPhoenix:3-way isolation,1.5rezistență kV, rentabil
1kV isolation,15răspuns ms1.2kV isolation,12răspuns ms
  1. Mediul de aplicare & Cazuri industriale

5.1 Aplicații recomandate

  1. Automatizare industrială: Signal isolation between PLC and field sensors/actuators to eliminate ground loop interference
  2. Industria de proces: Safe transmission of analog signals for chemical, farmaceutic, alimente & beverage in explosion-proof environment
  3. Energie Nouă: Pitch control monitoring for wind turbine, PV inverter signal acquisition, substation remote signaling renovation
  4. Tranzit Feroviar: Signal isolation for train control & on-board equipment with superior EMC resistance
  5. Tratarea apei: PLC automation system for municipal water plant, safe integration of process sensor signals

5.2 Aplicații nerecomandate

  1. Intrinsically Safe hazardous area (Select MCR-EX intrinsic safety series instead)
  2. Ultra-low temp (<-20°C) or ultra-high temp (>+65°C) mediu
  3. Special project requiring isolation voltage higher than 1.5kV
  4. High-frequency signal processing above 30Hz bandwidth

5.3 Cazuri tipice de aplicare

Caz 1: Automotive Production Line

Aplicație: Signal isolation for welding robot controller & pressure transmitter

Issue: Severe EMI from welding current causes distorted sensor readings

Soluţie: Install MCR-C-UI-UI-DCI isolator, 1.5kV galvanic isolation, conversion error<0.1% to guarantee precise pressure control

Caz 2: Municipal Wastewater Treatment Plant

Aplicație: Conversion & isolation between pH sensor and PLC analog input

Issue: Different equipment ground potential drift leads to unstable output

Soluţie: Adopt 3-port isolation to cut ground loop; convert 0–10V sensor signal to standard 4–20mA for up to 1000m long-distance cabling

  1. Sfaturi de selecție & Quick Reference Rules

Reguli de selecție rapidă

  1. Identificarea modelului: MCR-C=standard size; UI=universal I/O; DCI=DC galvanic isolation
  2. Specificații cheie: 3-way isolation @1.5kV, 0–10V/4–20mA, 0.1%FS accuracy,11ms step response
  3. Opțiune de upgrade: Compact space saving → MACX MCR series PN:2811284
  4. Application Rule: Ground loop trouble →3-port isolation; long cable run →4–20mA output
  5. Conformitatea transportului aerian & CE Certification Summary

7.1 Air Transport Compliance

Lithium Battery Check: No built-in lithium cell, classified as non-restricted goods without special shipping marking

Clasificarea transporturilor: Complies with IATA DGR Class9, acceptable as general cargo

Ambalare: Original factory carton preferred; ESD bag protection recommended

7.2 CE Certification Info

Standarde aplicabile: EN61000-6-2 (Immunity), EN61000-6-4 (Emission)

DOC Download: EU Declaration of Conformity available on Phoenix official website (Doc No.:083097087_04_DoC_EU.pdf)

Valid Scope: All EU member states & regions accepting CE marking

  1. Ghid de depanare
Fault SymptomRoot CauseRemedy
Power LED off1. Missing power or reverse polarity1. Rewire DC supply with correct polarity
2. Supply out of 18–30V range2. Measure & adjust input to rated 24V DC
No output variation1. Improper input wiring1. Verify input wiring & signal type
2. Wrong DIP switch setting2. Reconfigure DIP switches
3. Load out of specification3. Voltage output ≥10kΩ; Current output ≤500Ω
Fluctuating output1. Input signal interfered1. Single-point grounding for shield cable
2. Excessive power supply ripple2. Add power filter
3. Poor module earthing3. Secure module chassis ground
Excessive conversion error1. Zero/Span drift1. Re-trim Zero & Span (±2% adjustable)
2. Ambient temp out of rated range2. Improve cabinet ventilation
3. Mismatched load impedance3. Adjust load to specified range

Phoenix MCR‑C‑UI‑UI‑DCI (2810913) On-site Installation Manual

  1. Safety Precaution (Mandatory Reading)

Clasa de protectie: IP20, indoor dry cabinet installation only

Rezistenta la Tensiune: In-Out 1.5kV AC/60s; Power-Signal 1kV AC/60s, overvoltage withstand test prohibited

ESD Protection: Static-sensitive component; discharge body static by touching grounded metal before handling

Hazardous Area: Suitable for Zone2 / Class I Div.2 only; MCR‑EX IS series for Intrinsically Safe location

Alimentare electrică:18–30V DC (Nominal 24V DC); reverse polarity will permanently damage unit, confirm polarity prior to power-up

  1. Unpacking & Inspecţie

2.1 Lista de ambalare

Isolation amplifier MCR‑C‑UI‑UI‑DCI (2810913) ×1

This installation manual ×1

Factory test certificate ×1

2.2 Visual Check

No housing crack, intact snap latch, non-deformed & rust-free terminals

Confirm model & part No.: MCR‑C‑UI‑UI‑DCI / 2810913

  1. Mediul de instalare & Clearance Requirement

3.1 Ambient Condition

Temp. de operare: -20°C ~ +65°C

Storage Temp: -25°C ~ +70°C

Umiditate:10%~90% non-condensing

Min.30cm clearance away from strong EMI source (VFD, large motor, transformator)

3.2 Distanța de montaj

Munte: Sina DIN standard de 35 mm (EN60715), any mounting direction allowed

Side gap between adjacent modules ≥5mm

Vertical top/bottom clearance ≥20mm for heat dissipation & întreţinere

Install at upper/middle cabinet position; avoid dusty bottom compartment

  1. DIN Rail Mount & Dismount Steps

4.1 Montare

  1. Clean DIN rail from grease & burr, ensure reliable rail grounding
  2. Flip upward the orange top latch of module
  3. Hook upper notch onto top edge of DIN rail then press down module bottom
  4. Audible click sound confirms locked & fixed without wobble

4.2 Dismounting

  1. Cut off module power & all field signals first; no live removal allowed
  2. Lift orange release latch upward
  3. Lift module bottom upward to detach from DIN rail then take out
  4. Definiția terminalului & Specificații de cablare

5.1 Terminal Pinout (Left to Right)

Pin No.MarcareDefiniţieNota
1.1IN UTensiune de intrare (0-10V)Signal Positive
1.2IN IIntrare curentă (4-20mA)Signal Positive
1.3GND 1Input CommonSignal Negative
2.1OUT UTensiune de ieșire (0-10V)Signal Positive
2.2OUT IIeșire curentă (4-20mA)Signal Positive
2.3GND 2Output CommonSignal Negative
3.124În DCPositive Power18–30V DC
3.2GNDNegative PowerSupply Ground

5.2 Standard de cablare

Cable strip length:8mm (too long → short circuit; too short → poor contact)

Conductor size: Solid/Flexible 0.2–2.5mm² (AWG24–14); ferrules required for stranded flexible wire

Screw torque:0.5~0.6N·m for M3 terminal, avoid over-tightening thread slip

Shield cable: Single-end cabinet grounding (transmitter end floating) to eliminate ground loop

5.3 Typical Wiring Examples

Ex1: 4–20mA Input →4–20mA Output (2-wire transmitter)

Transmitter + →1.2(IN I)

Transmitter − →1.3(GND1)

2.2(OUT I) →PLC AI+

2.3(GND2) →PLC AI−

3.1→24V DC+;3.2→24V DC−

Ex2:0–10V Input→0–10V Output (Voltage sensor)

Sensor +→1.1(IN U)

Sensor −→1.3(GND1)

2.1(OUT U)→PLC AI+

2.3(GND2)→PLC AI−

3.1→24V DC+;3.2→24V DC−

  1. DIP Switch Configuration (Factory preset for 2810913:0–10V/0–10V)

6.1 Switch Location (Side housing; remove cover to access)

S1: Input Configuration

S1‑1:OFF=0–10V; ON=4–20mA

S1‑2:OFF=Unipolar; ON=Bipolar(±5V/±10V)

S2: Configurare ieșire

S2‑1:OFF=0–10V; ON=4–20mA

S2‑2:OFF=Unipolar; ON=Bipolar(±5V/±10V)

6.2 Implicit din fabrică (2810913)

S1:OFF/OFF (Unipolar 0–10V Input)

S2:OFF/OFF (Unipolar 0–10V Output)

6.3 Setting Procedure

  1. Cut off power supply then remove 2 cross-head screws to open cover
  2. Toggle DIP switches as required with fully seated position
  3. Refit housing & tighten screws before power-on test
  4. Power-up & Commissioning

7.1 Inspecție pre-putere (Obligatoriu)

Full wiring check: No cross-connection, short circuit or loose terminal

DC supply test: 24V DC ±10% measured across pin3.1 &3.2

Isolation test: No continuity between Input/Output/Power with multimeter continuity mode

7.2 LED Status Indication

PWR(Verde): Steady ON=Normal Supply; OFF=Power fault/reverse polarity

RUN(Verde): Blinking=Running normally; Solid/OFF=Module malfunction

7.3 Calibrare (Optional for high precision requirement)

Zero Adjustment: Feed zero input signal, trim ZERO potentiometer for zero output

Span Adjustment: Feed full-scale input, trim SPAN potentiometer for full-scale output

Precizie: ≤0.1%FS, max temperature drift ≤±2%

  1. On-site Quick Troubleshooting

8.1 Power LED Dark

Cauza: Reverse polarity, abnormal voltage, cabluri libere | Action: Correct polarity, measure voltage, retighten terminals

8.2 Zero Output Signal

Cauza: Cablaj greșit, mismatched DIP setting, suprasarcina | Action: Recablați, reset switches, check load impedance

8.3 Unstable Swinging Output

Cauza: Improper shield grounding, high supply ripple, nearby EMI | Action: Single-point ground, install power filter, relocate away from interference source

8.4 Out-of-spec Accuracy

Cauza: Thermal drift, zero/span shift, mismatched load | Action: Recalibrate, îmbunătățirea ventilației, adjust load

  1. Întreținere periodică

Every 6-month routine: Power off to clean terminal/housing, recheck screw torque & recalibrate accuracy

Forbidden operation: Hot plug/unplug, overvoltage/overtemperature running, unauthorized internal circuit disassembly

  1. Suport tehnic & Alternative Part

Manufacturer Support: Phoenix Contact China

Înlocuire upgrade: MACX MCR‑UI‑UI (2811284):12.5mm latime, lower power consumption, faster response speed