Schmersal SRB301LC-24V Safety Relay

Model Code Breakdown SRB: Schmersal Safety control module of PROTECT series (safety relay) 301: Model de bază, dual-channel passive input, oprire de urgență / safety gate monitoring LC: Terminal cu șurub (0.25~2,5 mm²), built-in glass fuse, no electronic fuse 24V: Universal supply voltage 24V AC/DC 101163475: Unique factory order number; Alternative order number: 101165472 Specificații electrice de bază 2.1 Putere ...

  • Detalii despre produs

Defalcarea codului de model

  1. SRB: Schmersal Safety control module of PROTECT series (safety relay)
  2. 301: Model de bază, dual-channel passive input, oprire de urgență / monitorizarea portilor de siguranta
  3. LC: Terminal cu șurub (0.25~2,5 mm²), built-in glass fuse, no electronic fuse
  4. 24V: Universal supply voltage 24V AC/DC
  5. 101163475: Unique factory order number; Alternative order number: 101165472
  6. Specificații electrice de bază

2.1 Alimentare electrică

Tensiune nominală: Dual-purpose 24V AC/DC

DC range: 20.4~28.8V DC (-15%/+20%)

AC 50/60Hz: 20.4~26.4V AC (±10%)

Consumul de energie: 1.7W / 1.9VA

Circuit fuse: 0.5A gG glass fuse (standard for LC version)

2.2 Input Circuit (Dual-channel Monitoring)

2 independent safety inputs A/B, compatible with passive contacts: butoane de oprire de urgență, safety gate switches, magnetic safety switches

Equipped with wire break detection and ground fault detection; No cross-channel short-circuit detection

Max cable length: 2500m (2.5mm² wire, loop resistance ≤40Ω)

2.3 Output Contacts (Core for Safety Rating)

Main safety contacts: 3 Deschis normal (NU) forced-guided contacts, Stop Category 0

Auxiliary signal contact: 1 În mod normal închis (NC) fault feedback output (ERR diagnosis)

Contact protection fuses: 6A T for safety circuit; 2A T for auxiliary circuit

Max switching frequency: 5Hz; Contact resistance ≤100mΩ

  1. Safety Certification Ratings (Mechanical Safety Standards)

ÎN ISO 13849-1: PL e / Cat.4 (Highest mechanical safety level)

IEC 61508: SIL 3

Compliant standards: ÎN 60947-5-1, ÎN ISO 13850 (Oprire de urgență), ÎN 60204-1 Machinery Standard

  1. Mecanic & Parametrii de mediu

Montare: Standard snap-on 35mm DIN rail mounting

Clasa de protectie: IP20 (For cabinet internal use only)

Temperatura de functionare: -25℃ ~ +45℃

Locuințe: Glass fiber reinforced flame-retardant plastic

Greutate: Aproximativ. 249g

Terminale: Screw-clamp type, suitable for 0.25~2.5mm² single/multi-strand wires

  1. Funcții & Aplicații tipice

5.1 Funcții de bază

Dual-channel cross-check; All safety outputs cut off immediately upon single-channel wire break or ground fault

Process passive contact signals (oprire de urgență, safety gates, door interlock switches)

ERR fault output for external PLC / indicator light diagnosis

No automatic reset; Safety circuit must be reclosed to reset after fault clearance

5.2 Aplicații tipice

Safety circuit monitoring for machine tools, echipamente de ambalare, linii de producție automate, mașini de turnat prin injecție, logistics sorting systems, lithium battery equipment and rail transit equipment

  1. Series Model Comparison (Referință de selecție)
Model SuffixTip terminalFuse TypeNumăr de ordine
LCScrew terminal 0.25~2.5m㎡Glass fuse101163475 (This model)
LCIPlug-in screw terminal 0.25~2.5m㎡Electronic fuseSeparate order number
LCI/7Plug-in cage clamp terminal 0.25~1.5m㎡Electronic fuseSeparate order number
LC/BCompatible with active safety light curtain signalsGlass fuse101177962
  1. Critical Risk Warnings
  2. Only applicable to passive contact safety switches. For safety light curtains (active AOPD), select model SRB301LC/B with suffix B
  3. Stop Category 0: Main circuit power cut-off with instantaneous stop; Not suitable for equipment requiring delayed braking
  4. Forced-guided contacts shall not be connected in parallel for capacity expansion; External contactors are required for heavy loads
  5. Must be matched with Cat.4 dual-channel safety components; Single-channel wiring cannot achieve PL e rating

Full Output Contact Capacity Specifications of SRB301LC-24V (Partea nr. 101163475)

  1. 3 Main Safety Normally Open Contacts (13-14 / 23-24 / 33-34)

1.1 Standard Rated Capacity for Resistive Loads

Max voltage: 250 VAC

Curent nominal: 6 O (AC-1 resistive)

Minimum reliable switching capacity: 10 V / 10 mA (to avoid contact non-conduction)

1.2 Standard Utilization Categories (ÎN 60947-5-1)

AC-15 (Sarcini inductive: AC solenoid valves / contactoare): 230 VAC / 6 O

DC-13 (Sarcini inductive: DC solenoid valves): 24 VDC / 6 O

1.3 Peak / Short-term Parameters (For Reference Only, Not for Continuous Operation)

The datasheet states a short-term limit of 8A. For engineering continuous loads, sizing shall be based on 6A. Freewheeling diodes or varistors shall be connected in parallel for arc suppression on inductive loads.

1.4 Matched Protection Fuse

Standard 6A time-lag fuse for safety circuit; Higher rated fuses are strictly prohibited.

  1. 1 Auxiliary Normally Closed Fault Contact (41-42 ERR Diagnosis)

Capacitate nominală: 24 VDC / 2 O

Matched fuse: 2A time-lag fuse; Only for small signal loops such as PLC feedback and fault indicator lights, not for heavy loads.

  1. Selectarea tastelor & Operation Restrictions
  2. Parallel connection of the three safety contacts for capacity expansion is forbidden. External safety contactors must be used for loads exceeding 6A.
  3. Stop Category 0 with instantaneous cut-off, suitable for cutting off main contactor coil circuits via emergency stops and safety gates.
  4. Arc suppression circuits are mandatory for inductive loads (electrovalve, bobine), otherwise contact service life will be drastically shortened.
  5. Derating is required at ambient temperature above 40℃; Max switching frequency is 5Hz.

Official Standard Response & Delay Specifications of SRB301LC-24V (101163475)

  1. Trip Response Time (Cut-off triggered by emergency stop / safety gate, core safety index)
  2. Maximum rated dropout delay specified in official manual: ≤50 ms
  3. Typical measured value of SRB301LC/B with identical architecture: ≤25 ms (Total breaking time of main safety contacts after dual-channel fault or emergency stop input disconnection)

> Nota: 50ms is the conservative upper limit from the manufacturer. Under normal engineering operating conditions, cut-off is generally completed within 20~30ms, complying with Stop Category 0 emergency stop safety regulations.

  1. Make Delay (Safety circuit recovery, contact closing)
  2. Make delay for manual start via reset button: ≤20 ms (Output energized after safety gate closed and reset button pressed)
  3. Make delay under auto-start mode: ≤300 ms (Scenario without reset button, auto-energization upon power-up)
  4. Typical basic make delay stated in general datasheets: ≈30 ms
  5. Supplementary Key Notes
  6. This response time covers the total duration of dual-channel input logic detection plus internal electromechanical relay breaking, not merely mechanical contact actuation time.
  7. Wire break, cross-channel short-circuit and ground fault detection also cut off safety outputs within ≤50ms.
  8. Compared with LC/B light curtain version with trip time ≤25ms, the upper limit for SRB301LC-24V (standard passive contact model) is extended to 50ms. 50ms shall be adopted for safety distance calculation in SISTEMA safety assessments.
  9. Upper switching frequency limit: 5Hz; Minimum full cycle make-break period: 200Domnișoară. High-frequency operation is not allowed.
  10. Reference for Safety Calculation During Selection

If the equipment requires total shutdown reaction time (comutator + releu + contactor), adopt the conservative value of 50ms for this relay to calculate safety distance.