Schneider LC1N2501 AC Contactor - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

 Schneider LC1N2501 AC Contactor - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

contactor/

Schneider LC1N2501 AC Contactor

LC1N2501 is a 3-pole 25A AC Contactor of Schneider Electric EasyPact D3N Series. It is standard configured with 3 contactele principale deschise în mod normal + 1 contact auxiliar normal închis. It is suitable for 11kW / 380V motor control under AC-3 duty, widely used in industrial automation and motor control circuits, featuring high reliability and flexible ...

  • Detalii despre produs

LC1N2501 is a 3-pole 25A AC Contactor of Schneider Electric EasyPact D3N Series. It is standard configured with 3 contactele principale deschise în mod normal + 1 contact auxiliar normal închis. It is suitable for 11kW / 380V motor control under AC-3 duty, widely used in industrial automation and motor control circuits, featuring high reliability and flexible installation.

  1. Definirea segmentului de model
SegmentSensDescriere detaliată
LC1Cod seria produsuluiLC = TeSys series contactor; 1 = Standard AC contactor
NSub-series identifierN = EasyPact D3N Series (replaces the original LC1E Series); economy design for general industrial applications
25Curent nominal de funcționareMain contact rated current 25A (AC-3 / 440V, 60°C)
1Configurarea contactelor auxiliare0 = 0 Deschis normal; 1 = 1 În mod normal închis, i.e. 1 Contact auxiliar NC
[Sufix]Codul tensiunii bobineide ex. M5=220V AC 50Hz, B5=24V DC, C5=36V AC, F5=110V AC, Q5=380V AC

Complete Model Examples:

LC1N2501M5N (220bobina V AC, 50Hz)、LC1N2501B5N (24V DC coil)

  1. Parametrii de specificație de bază
Categoria parametrilorTechnical IndexObservații
Basic Characteristics
Tip de produs3-Pole AC ContactorEasyPact D3N Series, replacement for LC1E2501
MarcaSchneider ElectricBenchmark brand in industrial control
Main Contact Configuration3NU (3 Deschis normal)Standard AC-3 motor control configuration
Configurarea contactelor auxiliare1NC (1 În mod normal închis)Expandable up to maximum 4 contacte auxiliare (2NU+2NC)
Curent nominal de funcționare25O (AC-3, 440V, 60°C)Corresponding motor power: 11kW@380V, 15kW@220V
Tensiune nominală de funcționare≤690V AC (50/60Hz)Maximum working voltage of main circuit
Performanță electrică
Rated Insulation Voltage Ui690VConform IEC 60947-4-1
Rated Impulse Withstand Voltage Uimp6kVStrong surge withstand capability
Frecvența nominală de operare1200 cycles/hour (AC-3)Suitable for frequent start-stop operation
Viața mecanică≥10 million cyclesHigh durability design
Viața electrică≥1 million cycles (AC-3, curent nominal)Meets long-term service requirements
Tensiune de control al bobinei24V~380V AC/DC optionalStandard: 220V și (M5)
Consumul de energie al bobineiRidicare: aproximativ. 100VA; Deţinere: aproximativ. 10VAConsum redus de energie, economisitoare de energie & high efficiency
Physical Dimensions
Metoda de montare35mm Montare pe șină DIN sau cu șurubTwo mounting options for different cabinet layouts
Dimensiunea de ansambluW45mm × H80mm × D85mmDesign compact, saves cabinet space
GreutateAproximativ. 170gUșoare pentru instalare ușoară & handling
Tip terminalCircuitul principal: Screw type; Circuit de control: Spring typeMain circuit compatible with 1.5-10mm² wire, tightening torque 1.85N·m
Condiții de mediu
Temperatura de operare-25°C ~ +60°CGamă largă de temperatură, adapts to harsh industrial environments
Temperatura de depozitare-40°C ~ +85°CWithstands extreme temperature storage
Protecție la intrareIP20Protects against finger access and solid foreign objects, suitable for cabinet installation
Humidity Resistance5%~95% RH (necondens)Adapts to humid environments
Certificari & Standarde
Main StandardsIEC 60947-4-1, GB14048.4Compliant with international and national standards
Certification MarksCCC, CE, UL, CSAGlobal market access qualifications
  1. Lista de accesorii & Mounting Parts
Part ModelNumeFuncţieScenariul aplicației
LRN07N-LRN35NReleu termic de suprasarcinaDirect plug-in with contactor, provides motor overload protectionMotor control circuit requiring overload protection
LANN01N-LANN22NBloc de contact auxiliarExpand auxiliary contact quantity (max. 2NU+2NC)Complex control circuits requiring more auxiliary contacts
LA9D09978CMechanical Interlock AccessoryInterlocks two contactors to prevent phase-to-phase short circuitReversible motor control (Forward/Reverse)
LA9D0902Mecanic + Electrical InterlockDual protection of mechanical and electrical interlockReversible control circuits with high safety requirements
Overvoltage Suppression ModuleRC / Varistor Surge SuppressorAbsorbs back EMF generated during coil de-energizationProtects electronic components in control circuit
Sina de montare35mm Standard DIN RailFixes contactor in positionStandardized installation inside control cabinet
Capac de protecție a terminalelorInsulating Protective ShieldPrevents accidental electric shock and improves safetyProtection for exposed terminals, complies with safety regulations
Installation ManualOperation GuidelineProvides detailed installation procedures and wiring diagramsOn-site installation guidance to ensure correct wiring
  1. Competitor & Echivalent între mărci
MarcaModel de înlocuireSimilar FeaturesDiferențele
Schneider Internal ReplacementLC1D25013-pole 25A, 1NC auxiliary, AC-3 11kWTeSys D series, better performance, higher price
ABBA16-30-013-pole 25A, 1NC auxiliary, 11kW@400VSimilar dimension, slightly higher coil power consumption, comparable price
Siemens3RT2026-1BB403-pole 25A, 1NC auxiliary, 11kW@400VDurata de viata mecanica 10 milioane de cicluri, viata electrica 2 milioane de cicluri, slightly higher price
MitsubishiS-N253-pole 25A, 1NC auxiliary, 11kW@400VSmaller size, compact mounting, pret moderat
ChintCJX2-25013-pole 25A, 1NC auxiliary, 11kW@380VAlternativă internă, performanță la costuri ridicate, similar performance
DeliciosCJX2S-25013-pole 25A, 1NC auxiliary, 11kW@380VAlternativă internă, lower price, suitable for budget-limited projects
  1. Ghid de selecție & Replacement Solutions

5.1 Key Selection Parameters

ParametruPuncte cheie ale selecțieiRecommended Specification
Rated Current MatchingContactor rated current ≥ motor rated current (Sarcina AC-3)25A contactor suitable for ≤11kW/380V motors
Configurarea contactelor auxiliareSelect NO/NC quantity according to control circuit demandStandard 01(1NC); Normally Open select 10(1NU); More contacts select 22
Coil Voltage SelectionConsistent with control circuit voltageIndustrial common: 220V și(M5); Safety voltage: 24În DC(B5)
Metoda de montareDetermined by control cabinet layoutMontare pe șină DIN (standard); Screw mounting for limited space
Protection RequirementNeed for overload protection and interlock functionMotor control must match LRN thermal relay; Reversible control requires interlock accessory
Frecvența de operareHigh-frequency start-stop occasion requires high-cycle modelStandard 1200 cycles/hour; Ultra-high frequency choose LC1D series

5.2 Recomandări de înlocuire

Current rating mismatch:

Motor power ≤7.5kW: Select LC1N1801 (18O)

Motor power 15kW: Select LC1N3201 (32O)

Insufficient auxiliary contacts:

Add LANN series auxiliary contact block, expandable up to 2NO+2NC maximum

Different control voltage:

24V DC control: LC1N2501B5N

380V AC control: LC1N2501Q5N

Higher performance required:

Choose LC1D2501 (TeSys D series), mechanical life 10 milioane de cicluri, viata electrica 2 milioane de cicluri, stronger vibration resistance

Budget limited:

Adopt domestic alternatives such as Chint CJX2-2501, Delixi CJX2S-2501; similar performance with price reduced by about 30-50%

5.3 Application Precautions

  1. Confirm coil voltage matches control circuit before installation to avoid coil burnout.
  2. Fasten main circuit wiring with recommended torque 1.85N·m to prevent overheating and poor contact.
  3. When directly plugging with LRN series thermal relay, ensure complete latch locking to prevent loosening by vibration.
  4. Reversible control circuit must be equipped with LA9D09978C mechanical interlock to prevent phase-to-phase short circuit.
  5. It is recommended to parallel surge suppressor at both ends of the coil to protect PLC/relay contacts in control circuit.
  6. When ambient temperature exceeds 40°C, derate rated current (10% reduction per additional 10°C rise).
  7. Regularly check contact ablation; replace contactor when main contact wear exceeds 1mm.
  8. Scenarii tipice de aplicare

Direct starting control of three-phase asynchronous motor (≤11kW/380V)

Start-stop control for fans, pompe de apă și mașini generale

Electrical control for compressors, conveyors and industrial equipment

Compressor control for air conditioning and refrigeration systems

Lighting and ventilation system control in building electrical systems

Motor control circuits for automated production lines

Auxiliary motor control for machine tool equipment

Output switching control for photovoltaic inverters and UPS power supplies

Complete Model List of Schneider LC1N Series (EasyPact D3N) Contactoare

LC1N Series is Schneider Electric EasyPact D3N 3-pole AC contactor, replacing the original LC1E Series. It is designed for AC-3 motor control, covering current ratings from 6A to 95A, with multiple auxiliary contact configurations and coil voltage options. Supports DIN rail or screw mounting with IP20 ingress protection.

  1. Reguli de codificare a modelelor
SegmentSensValoare opționalăDescriere
LC1Seria de produseLC1Schneider TeSys contactor series
NSub-serieNEasyPact D3N Series (economy type)
XXCurent nominal06/09/12/18/25/

32/38/40/50/65

/80/95

Unit: O (AC-3/440V, 60°C)
YYContact auxiliar00/01/10/22/1100=No auxiliary; 01=1NC; 10=1NO; 22=2NO+2NC; 11=1NO+1NC
ZCoil Voltage CodeB/E/F/M/Q/B=24V; E=48V; F=110V; M=220V; Q=380V
5月7日Frecvenţă5月7日5=50Hz; 7=50/60Hz universal
N/COrigineN/CN=Standard; C=Made in China

Complete Model Example:

LC1N2501M5N (25O, 1NC, 220V AC 50Hz)

  1. Full Current Rating & Basic Model Matrix

2.1 Standard Auxiliary Configuration (01/10)

Curent nominalPuterea motorului egală(380V)1NC(01)1NU(10)Observații
6O2.2kWLC1N0601LC1N0610Minimum current size
9O3kWLC1N0901LC1N0910
12O4kWLC1N1201LC1N1210
18O7.5kWLC1N1801LC1N1810
25O11kWLC1N2501LC1N2510Most commonly used
32O15kWLC1N3201LC1N3210
38O18.5kWLC1N3801LC1N3810
40O22kWLC1N4001LC1N4010
50O25kWLC1N5001LC1N5010
65O30kWLC1N6501LC1N6510
80O37kWLC1N8001LC1N8010
95O45kWLC1N9501LC1N9510Maximum current size

2.2 Special Auxiliary Configuration (11/22/00)

Curent nominal1NU+1NC(11)2NU+2NC(22)No Auxiliary(00)Scenariul aplicației
6A~38ALC1NXX11LC1NXX22LC1NXX00Complex control circuit requiring multi-contacts
40A~95ALC1NXX11LC1NXX22LC1NXX00High-power motor control requiring contact expansion
  1. Complete Coil Voltage Options

3.1 AC Coil Voltage Code

Voltage CodeTensiunea bobineiFrequency CodeComplete Model ExampleScenariul aplicației
B24V și5(50Hz)/7(50/60Hz)LC1N2501B5N / LC1N2501B7NSafety voltage control, PLC output
C36V și5-7LC1N2501C5N / LC1N2501C7NSafety circuit, machine tool control
E48V și5-7LC1N2501E5N / LC1N2501E7NIndustrial control, special equipment
F110V și5-7LC1N2501F5N / LC1N2501F7NNorth American standard, partial equipment
M220V și5-7LC1N2501M5N / LC1N2501M7NChinese industrial standard, most widely used
P230V și5-7LC1N2501P5N / LC1N2501P7Nstandard european, compatible with 220V
Q380V și5-7LC1N2501Q5N / LC1N2501Q7NHigh-voltage control circuit, direct 380V supply
R400V și5-7LC1N2501R5N / LC1N2501R7NEuropean industrial standard
S415V și5-7LC1N2501S5N / LC1N2501S7NSoutheast Asian standard

3.2 DC Coil Voltage Code

Voltage CodeTensiunea bobineiComplete Model ExampleScenariul aplicației
B24În DCLC1N2501B5NSafety control, PLC digital output
L48În DCLC1N2501L5NIndustrial DC system
K110În DCLC1N2501K5NSpecial DC equipment
N220În DCLC1N2501N5NHigh-voltage DC control
  1. Common Complete Model Combinations
Model completActualContact auxiliarTensiunea bobineiPuterea motorului egalăAplicație tipică
LC1N2501M5N25O1NC220V AC 50Hz11kWPompa de apa & fan control
LC1N3210B7N32O1NU24V AC 50/60Hz15kWPLC control circuit
LC1N1801F5N18O1NC110V AC 50Hz7.5kWExport equipment
LC1N5011M7N50O1NU+1NC220V AC 50/60Hz25kWCompressor control
LC1N6522Q5N65O2NU+2NC380V AC 50Hz30kWLarge fan
LC1N0900B5N9ONo auxiliary24V AC 50Hz3kWSimple control circuit
LC1N9511M7N95O1NU+1NC220V AC 50/60Hz45kWHigh-power motor
  1. Selection Reference Table

5.1 Current Rating vs Motor Power (AC-3/380V)

Curent nominalMotor Power(kW)Wire Size(mm)Matching Thermal Relay
6O2.21.5LRN06N
9O31.5LRN06N
12O41.5LRN07N
18O7.52.5LRN10N
25O114LRN14N
32O156LRN21N
38O18.56LRN21N
40O2210LRN25N
50O2510LRN32N
65O3016LRN35N
80O3725LRN35N
95O4535LRN40N

5.2 Auxiliary Contact Expansion Options

Base ModelExpandable AccessoryExpanded Contact ConfigurationScenariul aplicației
LC1NXX01/10LANN01N(1NU)2NU / 2NCAdd more control circuit contacts
LC1NXX01/10LANN22N(2NU+2NC)3NU+2NC / 2NU+3NCComplex control logic
LC1NXX00LANN01N+LANN02N1NU+1NCExpand from no auxiliary to standard configuration
  1. Quick Model Selection Guide
  2. Confirm current rating: Select according to motor power (Under AC-3 duty, contactor rated current ≥ motor rated current).
  3. Select auxiliary contacts: 01(1NC) for stop control; 10(1NU) for self-locking; 11(1NU+1NC) pentru control reversibil.
  4. Match coil voltage: Consistent with control circuit voltage (220V AC common; 24V DC for safety occasions).
  5. Frequency selection: Domestic standard 50Hz(Cod 5); Export equipment use universal 50/60Hz(Cod 7).
  6. Configurare accesorii: Motor control must match LRN thermal relay; Reversible control requires LA9D mechanical interlock.
  7. Common Model Replacement Table
Model originalModel de înlocuireReplacement Reason
LC1E2501LC1N2501EasyPact D3N replaces original EasyPact E Series
LC1D2501LC1N2501Economy model replaces high-performance model, cost reduced by approx. 20%
CJX2-2501LC1N2501Import replaced by domestic, performance improved with similar price

Prev:

Lasă un răspuns

Lăsaţi un mesaj