Releu Schneider RXM2AB2P7 - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

 Releu Schneider RXM2AB2P7 - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

electric/

Releu Schneider RXM2AB2P7

The RXM2AB2P7 is a plug-in miniature intermediate relay belonging to Schneider Harmony Zelio series, prezentând 2 contacte de schimbare (2CO/DPDT), 12O evaluare, 230bobina V AC, indicator LED încorporat și buton de testare blocabil. It matches RXZE series sockets, widely applied in industrial automatic control, PLC interface connection, motor control and building automation. It is certified with CE/UL/CSA/RoHS ...

  • Detalii despre produs

The RXM2AB2P7 is a plug-in miniature intermediate relay belonging to Schneider Harmony Zelio series, prezentând 2 contacte de schimbare (2CO/DPDT), 12O evaluare, 230bobina V AC, indicator LED încorporat și buton de testare blocabil. It matches RXZE series sockets, widely applied in industrial automatic control, PLC interface connection, motor control and building automation. It is certified with CE/UL/CSA/RoHS and compliant with air freight regulations (fara baterie cu litiu incorporata).

  1. Definiția codului modelului
SecțiuneCodSens
Cod de serieRXMZelio series plug-in miniature intermediate relay
Contact Quantity22 seturi de contacte cu comutare (2CO/DPDT), namely 2 deschis în mod normal + 2 în mod normal închis
Caracteristică funcționalăABEquipped with lockable test button + fereastra indicatoare mecanica + detachable label
Stare LED2With coil LED indicator (1 = without LED)
Tensiunea bobineiP7230V AC 50/60Hz

Definiție completă a modelului: Schneider Zelio RXM series plug-in miniature intermediate relay with 2 sets of 12A changeover contacts, buton de testare blocabil, fereastra indicatoare mecanica, LED indicator and 230V AC coil voltage.

  1. Parametrii tehnici de bază
Categoria parametrilorCaietul de sarciniObservații
Caracteristici de bază
Configurare contact2CO (DPDT / 2NU+2NC)Double-pole double-throw, AgNi silver-nickel contact material
Curent nominal de operare (Ie)12A @ 250V AC (IEC), 10A @ 300V AC (UL/CSA)Sarcină rezistivă
Tensiune nominală de izolație (Ui)250V (IEC), 300V (UL/CSA)Withstand voltage level
Tensiune nominală de rezistență la impuls (Ump)4kV (1.2/50μs)Surge protection capability
Coil Specifications
Tensiunea bobinei230V AC 50/60HzDefined by code P7
Consumul de energie al bobineiAproximativ. 1020mWPutere de operare
Ridicare / Drop-out Time≤20ms / ≤20msResponse speed
Rezistenta electrica10⁶ operations (sarcina nominala)Durability index
Rezistenta mecanica10⁷ operațiuniNo-load operation times
Fizic & Environmental Data
Dimensiune (L×A×D)22.5×57×44mmStandard DIN rail size
Tip de montareTip de plug-in, compatible with RXZE series socketsSocket sold separately
Clasa de protectieIP40Protecție împotriva prafului
Temperatura de operare-40°C ~ +55°CAdaptabilitate mare la temperatură
Temperatura de depozitare-40°C ~ +70°CTransport & storage temperature
Vibrație / Rezistenta la socuri10~55Hz, 0.5mm amplitudine dublă / 100m/s²Industrial environment adaptability
  1. Lista completă a modelelor din seria (RXM AB Series)
ModelContact NumberContact CurrentLEDTensiunea bobineiObservații
RXM2AB2P72CO12ODa230V șiModel standard
RXM2AB2B72CO12ODa24V șiCommon control voltage
RXM2AB2E72CO12ODa48V și
RXM2AB2F72CO12ODa120V și
RXM2AB2BD2CO12ODa24În DCVersiune DC
RXM2AB2FD2CO12ODa110În DC
RXM2AB2UD2CO12ODa220În DC
RXM4AB2P74CO10ODa230V și4-contact version
RXM3AB2P73CO10ODa230V și3-contact version
RXM2AB1P72CO12ONu230V șiNon-LED version

Mnemonic de selecție: Numbers stand for contact groups; AB/LB/CB define functions; 1/2 means with/without LED; P7/B7/E7/BD represent voltages; 12A/10A indicate contact current.

  1. Comparație între mărci & Modele de înlocuire

4.1 Internal Schneider Replacement

Model originalModel de înlocuireDescriere de înlocuire
RXN21P7RXM2AB2P7 + RXZE1M2C socketRXN series discontinued, replaced by RXM series
RXM2AB2P7RXM2AB2P7PVSVersion with surge suppression
RXM2AB2P7RXM2CB2P7Without detachable label (same function)

4.2 Competitor Equivalent Models

MarcaModelSpecificație echivalentăDiferenţă
Siemens3RT2016-1BB422CO, 12O, 230V șiDifferent mounting size, pret mai mare
ABBCR-M024DC22CO, 12O, 24În DCtip DC, răspuns mai rapid
OmronMY2N-GS2CO, 12O, 230V șiPreț mai mic scăzut, durata de viata mai scurta
WeidmüllerDRM570230LT2CO, 12O, 230V șiCu butonul de testare, Montare pe șină DIN
  1. Mediul de aplicare & Cazuri industriale

5.1 Scenarii aplicabile

IndustrieAplicație tipicăAvantaje
Automatizare industrialăExtindere ieșire PLC, signal amplificationLockable test button for easy troubleshooting
Controlul motoruluiPornire stea-delta, reversible control, soft starter triggering12A contact capacity fits contactor coil control
Automatizarea clădirilorHVAC system, controlul luminii, legătura de incendiuWide working temperature (-40°C~55°C), Protectie IP40
Sistem de alimentareSecondary circuit of switchgear, protection relay actuation4kV impulse withstand, strong anti-surge performance
Mașini de ambalareControlul benzii transportoare, cylinder solenoid valve driveFast response ≤20ms, long mechanical service life 10⁷ times

5.2 Aplicații nerecomandate

Direct control of high inductive loads (surge suppressor recommended)

Continuous load current over 12A (choose RXM4 series or contactors)

Severe oil mist and heavy dust environments (limited IP40 protection)

Strong electromagnetic interference environments (shielding measures suggested)

5.3 Cazuri tipice de aplicare

Caz 1: PLC-controlled motor forward/reverse circuit

Configurare: 2 sets of RXM2AB2P7 + RXZE1M2C sockets

Funcţie: Control forward/reverse contactor coils via PLC outputs to realize motor reversible operation

Avantaj: Quick fault judgment via lockable test button; mechanical window shows contact status intuitively

Caz 2: Zoned building lighting control

Configurare: 8 sets of RXM2AB2P7 + RXZE1M2C sockets

Funcţie: Independent on-off control of 8 lighting zones through building automation system

Avantaj: LED indicators facilitate inspection; IP40 protection adapts to electrical shaft environment

  1. Conformitatea transportului aerian & Certificari

6.1 Air Freight Compliance Judgment

Element de conformitateRezultatBază
Baterie cu litiu încorporatăNici unulElectromagnetic relay without battery components
Substanță magneticăMărfuri nepericuloaseWeak coil magnetic field, conform cu IATA DGR 2.3.2.2
Categoria de livrareMarfă generalăFără număr ONU, shipped as regular electronic products
Packaging RequirementGeanta antistatica + carton boxPreveniți deteriorarea pinului și electricitatea statică

6.2 Lista de certificare (Including Certificate No.)

CertificareStandard nr.Certificate Information
CEÎN 61810-1, ÎN 61810-3Comply with LVD 2006/95/EC & EMC 2014/30/EU directives
ULUL 508, UL 1059Certificatul nr.: E82889
CSAC22.2 Nr.14Certificatul nr.: LR64742
RoHS2011/65/UEMeet RoHS 2.0 restricții privind substanțele periculoase
AJUNGE(EC) Nu 1907/2006Free of SVHC high-concern substances
EACTR CU 004/2011Certificarea Uniunii Vamale pentru Rusia, Kazakhstan etc.
  1. Defecte comune & Ghid de depanare

7.1 Fault Quick Check Table

Fenomen de eroareCauze posibilePași de depanareSoluții
Coil no power (LED off)1. Alimentarea deconectată / wrong voltage1. Measure coil terminal voltage1. Correct power connection
2. Colac ars2. Testați rezistența bobinei (normal: aproximativ. 5kΩ)2. Înlocuiți releul
3. Poor socket contact3. Re-plug relay3. Clean socket contacts
Contacts fail to act1. Locked test button1. Unlock red test button1. Unlock button
2. Blocaj mecanic2. Press test button manually2. Înlocuiți releul
3. Sudarea la contact3. Check contact continuity after power off3. Replace contacts or relay
Lipirea contactului1. Supraîncărcare / scurt-circuit1. Verificați curentul de sarcină1. Derate usage or add contactor
2. Excessive surge current2. Test surge peak value2. Install surge suppressor
3. Uzura de contact3. Inspect contact ablation3. Înlocuiți releul
LED on but contacts not switching1. Too low coil voltage1. Ensure voltage ≥85% rated value1. Raise control voltage
2. Mechanical failure2. Check mechanical indicator window2. Înlocuiți releul
3. Oxidare de contact3. Curățați contactele3. Curățați sau înlocuiți contactele

7.2 Sugestii de intretinere

  1. Inspecție regulată: Check LED status, mechanical window and test button function every 6 luni
  2. Contact Life Management: Replace in advance when operation times approach 10⁶ cycles
  3. Controlul mediului: Avoid ambient temperature over 55°C or humidity over 95%; curățați praful în mod regulat
  4. Protecție la supratensiune: Install RC snubber or varistor for all inductive load circuits
  5. Informații de comandă & Selectarea accesoriilor

8.1 Coduri de comandă

Main Product: RXM2AB2P7 (relay body only, socket excluded)

Recommended Socket: RXZE1M2C (borna cu șurub, fits 2CO relays)

Surge Suppressor Module: RXZS1 (RC snubber for inductive loads)

8.2 Lista de accesorii

Nume accesoriuModelFuncţie
Screw Terminal SocketRXZE1M2CStandard mounting for 2CO relays
Spring Terminal SocketRXZE1M2PFast wiring, tool-free connection
Marker StripRXZE1LDetachable contact function marking
Suprimator de supratensiuneRXZS1Protect contacts and extend service life
Fixing ClipRXZE1CAnti-vibration, enhance mounting stability
  1. Selection Avoidance Tips
  2. Potrivirea tensiunii: Ensure coil voltage matches control circuit; never mix AC and DC (P7=230V AC, BD=24V DC)
  3. Capacitate de contact: ≤12A for resistive loads, ≤6A for inductive loads (50% derating recommended)
  4. Potrivirea prizei: Only use RXZE series sockets; do not mix other brands
  5. Test Button Note: Unlock the lockable button after use to avoid wrong fault judgment
  6. LED Indication Rule: 2 = with LED, 1 = without LED, select according to on-site demand

Rezumat: RXM2AB2P7 is a stable and fully-functional miniature intermediate relay suitable for most industrial control occasions. Focus on contact quantity, coil voltage and load type during selection. Equipped with matched sockets and accessories, it greatly improves system reliability and maintenance convenience.

Prev:

Următorul:

Lasă un răspuns

Lăsaţi un mesaj