Schneider time relay RE22R2QEMR

ModelFunctional DifferencesApplicable Scenarios
RE22R2AMRTime delay on power-on, single functionBasic sequence control
RE22R2KMRTime delay on power-off, dual outputDelayed shutdown after equipment stops
RE22R2QTMRDedicated for star-delta starting, supporting multi-mode switchingMotor step-down starting

  • Detalii despre produs

The following is a detailed analysis of the Schneider RE22R2QEMR releu de timp. Combining the latest search resources and technical documents, we provide you with comprehensive technical parameters, operation guides, and application suggestions:

Core Parameters and Functional Features

  1. Parametrii de bază

Voltage Range: 24-240V AC/DC (wide voltage compatibility, supporting mainstream global industrial power supplies)

– Configurare contact: Double Pole Double Throw (2CO), with a maximum load current of 8A (resistive load)

Time Range: 0.3 seconds to 30 secunde (adjustable in ranges, supporting three ranges of 0.3-3s, 1-10s, and 3-30s)

Accuracy: ±10% (full scale, in compliance with IEC 61812-1 standard)

– Temperatura de operare: -20°C până la +60°C (adapting to harsh industrial environments)

– Metoda de instalare: 35mm DIN rail or panel installation, with a depth of 79.5mm and a width of 90mm

– Certificari: International certifications such as UL, CSA, CCC, and RoHS.

  1. Functional Highlights

Dual Knob Adjustment: The top knob selects the time range (de ex., the 10-second range), and the bottom knob sets the percentage (de ex., 70% corresponds to 7 secunde), with intuitive operation.

Diagnosis and Status Indication:

YellowRindicator light: Lights up when the output is activated.

Test button: Supports manual triggering of the time delay function for quick verification of the circuit.

– Protecție de siguranță

Front panel with IP50 protection, resistant to dust and small water droplets.

Housing with IP40 protection, adapting to industrial environment vibrations (20m/s²) and impacts (15g).

  1. Application Scenarios and Typical Cases
  2. Automatizare industrială

– Controlul motorului: Star-delta starting sequence control (de ex., RE22R2QEMR supports the star-delta mode).

Production Line Synchronization: Delayed start and stop of conveyor belts to avoid idling of equipment.

Equipment Preheating: Delayed start of the cooling fan after the heating element is powered on.

  1. HVAC Systems

Fan Control: In air conditioning systems, the fan is turned off with a delay after the compressor stops to prevent condensate water from flowing back.

Water Pump Protection: Avoid current surges caused by the simultaneous start of multiple water pumps.

  1. Building and Energy

Lighting Control: Delayed light-off function in parking lots or warehouses.

Fire Protection Systems: Delayed start of the smoke exhaust fan after a fire alarm.

III. Operation and Maintenance Guide

  1. Time Setting Steps
  2. Select the time range: Switch the range through the top knob (de ex., the 10-second range).
  3. Fine-tune the percentage: Adjust the specific time with the bottom knob (de ex., 70% corresponds to 7 secunde).
  4. Verify the setting: Press the test button and observe the yellow indicator light and the action of the contacts.

Nota: There may be an error of ±10% in the actual time delay, and a margin should be reserved according to the requirements of the scenario.

  1. Wiring Example

Power Connection: Connect A1 (+) and A2 (-) to the 24-240V AC/DC power supply.

Load Connection:

Normally open contacts (15-18, 25-28): Close with a delay.

Normally closed contacts (15-16, 25-26): Open with a delay.

Control Signal: Trigger the action of the relay through an external signal (de ex., PLC output).

Tip: The circuit diagram is printed on the side of the relay, and the wiring method can be quickly confirmed.

  1. Troubleshooting

Indicator light not on: Check whether the power voltage and fuse are normal.

Contacts not operating: Clean the oxide layer on the contacts and check whether the load is overloaded.

Inaccurate time delay: Confirm whether the knob setting is correct, or replace the relay.

  1. Alternative Models and Purchase Suggestions
  2. Modele alternative
ModelFunctional DifferencesApplicable Scenarios
RE22R2AMRTime delay on power-on, single functionBasic sequence control
RE22R2KMRTime delay on power-off, dual outputDelayed shutdown after equipment stops
RE22R2QTMRDedicated for star-delta starting, supporting multi-mode switchingMotor step-down starting
  1. Canale de achiziție

Authorized Dealers: Use theDistributor Searchfunction on the Schneider official website and enter the region to filter certified suppliers.

– Preț de referință: The average market price of RE22R2QEMR is approximately WA: 0086-13811255435 yuan. For bulk purchases, you can contact the dealer to negotiate the price.

  1. Precautions and Compliance Requirements
  2. Model Confirmation: Avoid confusing similar models (de ex., RE22R2QGMR is a multi-functional version). It is recommended to use the Schneider product selection tool.
  3. Safety Specifications:

Ensure that the power is disconnected during installation to avoid electric shock.

The contact load shall not exceed 8A; otherwise, an intermediate relay needs to be equipped.

  1. Document Acquisition:

Official Manual: Visit the Schneider Support Center and search forRE22R2QEMRto download the PDF manual.

Detailed Technical Parameters of Schneider RE22R2QEMR Time Relay

The following is an analysis of the detailed technical parameters of the Schneider RE22R2QEMR time relay. Combining the latest technical documents and industrial application scenarios, we provide you with comprehensive performance indicators and design references:

  1. Parametrii electrici de bază
Nume parametruTechnical IndexApplication Value
Tensiune nominală24-240V AC/DC (Wide voltage compatibility, 50/60Hz)Supports mainstream global industrial power supplies, reducing adaptation costs
Consumul de energie AC: 3VA (at 240V)Low-power design, suitable for long-term operation
DC: 1.5W (at 240V)
Contact TypeDouble Pole Double Throw (2CO), Cadmium-free Silver Alloy ContactsEnvironmentally friendly and with strong arc resistance, suitable for high-reliability scenarios
Capacitate de contactResistive Load: 8A/250V ACCovers various load types such as motors, heaters, and solenoid valves
Inductive Load: 3A/250V AC (Power Factor 0.4)
Capacitive Load: 1A/250V AC
Viața electricăResistive Load: 100,000 operațiuniStrongly related to the load type, and the maintenance cycle needs to be evaluated according to the actual application
Inductive Load: 10,000 operațiuni
Capacitive Load: 5,000 operațiuni
Viața mecanică3.2 milioane de operațiuni (B10d standard, IEC 61812-1)Long-life design, suitable for scenarios with high-frequency actions
  1. Time Control Parameters
Nume parametruTechnical IndexDetalii tehnice
Time Range0.3 seconds to 30 secunde (Adjustable in three ranges)Knob adjustment, supporting fine adjustment at the 0.1-second level (de ex., the 10-second range can be accurate to 0.1 second)
– 0.3-3 secunde
– 1-10 secunde
– 3-30 secunde
Accuracy±10% (Full scale, at 25°C)Industrial-grade accuracy, meeting most timing control requirements
Repeat Accuracy±0,5% (Full scale)High stability, suitable for scenarios with repeated actions (such as production line cycle control)
Response Time≤100ms (Typical value 50ms)Fast triggering, suitable for devices with high real-time requirements
Reset Time≤120ms (After power-off)Ensures quick restoration to the initial state and avoids misoperation

III. Parametri mecanici și de mediu

Parameter NamTechnical IndexDesign Advantages
Dimensiuni22.5mm (Lăţime) × 79.5mm (Adâncime) × 90mm (Înălţime)Compact design, saving control cabinet space
Greutate90gLightweight, facilitating installation and maintenance
Metoda de instalare35mm șină DIN (ÎN 50022) or Panel InstallationSupports multiple fixing methods, adapting to different cabinet structures
Protection LevelHousing: IP40Dust-proof and splash-proof, adapting to harsh industrial environments
Front Panel: IP50
Terminals: IP20
Temperatura de operare20°C până la +60°C (No condensation)Wide temperature range operation, suitable for extreme climatic conditions
Temperatura de depozitare-40°C până la +70°CStrong long-term storage stability
Vibration/ShockVibration: 20m/s² (10-150Hz)Resistant to mechanical stress, suitable for vibrating environments (such as mobile devices)
Shock: 15g (11ms)
  1. Safety and Certifications
Nume parametruTechnical IndexCompliance
Insulation Resistance≥100MΩ (500În DC)High insulation performance, ensuring electrical safety
Dielectric Strength2.5kV AC (1 minute, between input and output)Complies with IEC 61812-1 standard
EMC CompatibilitySurge Resistance: 2kV (Common Mode)Industrial-grade anti-interference ability, suitable for complex electromagnetic environments
Radio Frequency Interference Resistance: 10V/m (80MHz-1GHz)
Certificari IEC 61812-1 (Time Relay Standard)Global market access, reducing certification costs
C257UL 508 (Industrial Control Equipment)
CE,CSA, CCC, RoHS -ECCSA、CCC
  1. Functional Features and Design Highlights
  2. Dual Knob Adjustment

Top Knob: Select the time range (de ex., the 10-second range).

Bottom Knob: Fine-tune the percentage (de ex., 70% corresponds to 7 secunde).

Sealed Cover Design: Prevents accidental touching of the adjustment knobs and ensures parameter stability.

  1. Diagnosis and Testing

LED Indicator Light: The yellowRlight indicates the output status.

Test Button: Manually triggers the time delay function to quickly verify the circuit logic.

  1. Environmental Friendliness and Reliability

Cadmium-free Contacts: Complies with the RoHS directive, reducing environmental pollution.

High MTTFd: Mean Time To Failure on Demand is 353.8 ani (IEC 61709 standard), suitable for critical mission scenarios.

  1. Parameter Adaptation for Typical Application Scenarios
Application FieldLoad TypeTime Setting ExampleContact Configuration Suggestions
Motor Star-Delta Starting7.5kW Three-phase MotorStar Operation for 10 seconds → Delta OperationNormally closed contacts control the star contactor
HVAC Fan Control220V AC FanTurn off with a 30-second delay after shutdownNormally open contacts control the power-off delay
Lighting System100W LED LampTurn off with a 30-second delay after personnel leaveNormally closed contacts are connected in series in the lighting circuit
Fire Smoke Exhaust24V DC Solenoid ValveStart immediately after the alarm and last for 10 minutesNormally open contacts directly drive the solenoid valve

VII. Selection and Maintenance Suggestions

  1. Comparison of Alternative Models
ModelDifferencesApplicable Scenarios
RE22R2AMRSingle output, time delay on power-onBasic timing control
RE22R2KMRDual output, time delay on power-offDelayed shutdown after equipment stops
RE22R2QTMRDedicated for star-delta, supports multi-mode switchingMotor step-down starting
  1. Ciclul de întreținere

Contact Inspection: Clean the oxide layer on the contacts every 6 months to ensure that the contact resistance ≤ 50mΩ.

Parameter Calibration: Verify the time delay accuracy using an oscilloscope every year. Replace it when the error exceeds ±15%.

  1. Troubleshooting

Abnormal Indicator Light: Check the power supply voltage (allowable fluctuation ±15%).

Contact Sticking: Measure the load current and avoid exceeding the 8A peak value.

Time Delay Drift: When the ambient temperature exceeds +50°C, it needs to be derated (for every 10°C increase, the service life is halved).

VIII. Official Resources and Purchase Information

Technical Documents: The Schneider official website provides the RE22R2QEMR Data Sheet (Document Number: SDOC-RE22R2QEMR-01), which contains detailed circuit diagrams and wiring guidelines.

– Canale de achiziție:

For further verification of parameters or obtaining customized solutions, it is recommended to provide specific application scenarios (such as load type, ambient temperature, installation method, etc.) to facilitate the recommendation of the optimal configuration.