Siemens 3RT2026-1AP00 AC Contactor

Model Code Breakdown Code Segment Code Definition 3RT2 3RT2 New-generation AC contactor of Siemens SIRIUS series, replacement for legacy 3RT1 series 26 26 Marimea S0, rated AC-3 current: 25O, compatible with 11kW motor at 400V 1 1 Tip bobină: AC-operated coil AP AP Coil voltage: 230V și, 50Hz standard mains supply 0 0 Configurație standard: ...

  • Detalii despre produs

Defalcarea codului de model

Segment de codCodDefiniţie
3RT23RT2Noua generatie contactor AC de Siemens seria SIRIUS, replacement for legacy 3RT1 series
2626Marimea S0, rated AC-3 current: 25O, compatible with 11kW motor at 400V
11Tip bobină: AC-operated coil
APAPTensiunea bobinei: 230V și, 50Hz standard mains supply
00Configurație standard: terminale cu șuruburi, 1Contacte auxiliare NO+1NC, fara optiuni speciale
  1. Specificații tehnice de bază
CategorieParametruRemarcă
Specificații de bază
Tip de produs3-pole AC power contactorSIRIUS range, Grad de protecție IP20
Curent nominal de operareAC-3: 25A @400V; AC-1:40A @400VAC-4:15.5A @400V
Putere nominală11kW under AC-3 at 400VFor standard 3-phase asynchronous motors
Configurația stâlpului3 main poles + 1Contacte auxiliare NO+1NCBuilt-in auxiliary contacts, no extra accessory required
Coil Data
Tensiunea bobinei230V și, 50HzGlobal standard industrial mains voltage
Consumul de energie al bobineiRidicare:105VA; Sealed holding:12VALow-power design for energy saving
Mecanic & Environmental Data
Dimensiunea de ansamblu(L×L×A)85mm×45mm×86mmCompact footprint for cabinet space saving
MontareMontare standard pe șină DINConform EN 50022
Ambient Operating Temp.-25°C ~ +60°CWide temperature tolerance for harsh industrial environments
ÎncetareaBorne cu șuruburiSecure connection suitable for repeated wiring
Rezistenta electrica1,000,000 operațiuni(AC-3); 10,000,000 operațiuni(AC-1)Long service life to cut maintenance cost
AprobariCE, UL, CSAGlobally accepted international safety certifications

III. Full 3RT2026 Series Model List (Cadru S0, 25A evaluat)

Sorted by coil voltage:

Partea nr.Tensiunea bobineiContacte auxiliareÎncetareaCaracteristica specială
3RT2026-1AP00230V și1NU+1NCŞurubVersiune standard
3RT2026-1AP60230V și1NU+1NCSpring-cageCablare rapidă
3RT2026-1AQ00110V și1NU+1NCŞurubVersiune standard
3RT2026-1AQ60110V și1NU+1NCSpring-cageCablare rapidă
3RT2026-1BB4024În DC1NU+1NCŞurubVersiune standard
3RT2026-1BB6024În DC1NU+1NCSpring-cageCablare rapidă
3RT2026-1BG4048În DC1NU+1NCŞurubVersiune standard
3RT2026-1BH40110În DC1NU+1NCŞurubVersiune standard
3RT2026-1BJ40220În DC1NU+1NCŞurubVersiune standard
3RT2026-1AP00-1AA0230V și1NU+1NCŞurubVertical mounting
  1. Referință încrucișată & Replacement List
  2. Siemens Internal Obsolete Replacement
Obsolete PartReplacement PartReplacement ReasonCompatibilitate
3RT1026-1AP003RT2026-1AP003RT1 discontinued; 3RT2 upgraded generationFull interchangeability, identical mounting dimension
3RT1026-1AP00-1AA03RT2026-1AP00-1AA0Same-series product upgradeFull interchangeability
3TF4322-0AP03RT2026-1AP00Outdated 3TF series, superior performance of 3RT2Minor cabinet modification needed for mounting
  1. Cross-Brand Equivalent Options
MarcaModelMatching ScoreDiferențele
ABBA16-30-01★★★★☆Rated 16A < 25O, derated operation required
Schneider ElectricLC1D25M7C★★★★★Full equivalent:25O,230V și,1NU+1NC
Allen-Bradley100-C25D*00★★★★☆Slightly larger dimension, functii identice
EatonDILM25-10★★★★☆Only 1NO auxiliary contact; extra NC contact needed separately
  1. Mediul de aplicare & Cazuri industriale
  2. Recommended Application Fields

Automatizarea fabricii: 3-phase asynchronous motor control ≤11kW@400V for pumps, fani & conveyor systems

Clădire electrică & HVAC: Air-conditioning units, ventilation blowers, fire fighting pumps

Tratarea apei & Wastewater: Pompe de canalizare, chemical dosing systems, filter equipment

Mâncare & Băutură: Production line motors, mixing machinery, mașini de ambalare

OEM Machinery: Masini-unelte, imprimare & packaging equipment OEM matching

  1. Not Recommended Application Conditions

Heavy shock & vibration sites (shipboard, mining machinery): Anti-vibration base required if mandatory use

Medii cu gaze corozive (electroplating, chemical plant): Sealed anti-corrosion contactor required

Ultra-frequent cycling loads (welding machine, rapid start-stop equipment): Select dedicated AC-4 rated contactor

High DC loads (DC motors, electrolysis equipment): Use dedicated DC-coil DC contactors

  1. Typical Application Examples

Caz 1: Blower Control for Small Sewage Treatment Plant

Echipamente: 3 sets of 5.5kW aeration blowers, 3-faza 400V

Control configuration: 3RT2026-1AP00 + 3RU2016-1CB00 thermal overload relay + Siemens PLC

Avantaje: Dimensiune compactă, integrated auxiliary contacts, simplified cabinet layout & consum redus de energie

Caz 2: Food Packaging Conveyor Line

Echipamente: Multiple 3kW conveyor motors with 230V AC control circuit

Control configuration:3RT2026-1AP00 + 3RH2111-1AP00 auxiliary contact block

Avantaje: Fast installation, high reliability for humid food workshop environment

  1. Ghid de selecție & Quick Coding Rules

Quick Selection Mnemonic

3RT2026 defined by 25A rated current

AP stands for 230V AC coil voltage

Standard 1NO+1NC with screw terminal wiring

Direct upgrade substitute for old 3RT1026

Perfect match for 11kW motor at 400V supply

Quick Coding Rules

  1. Model breakdown:3RT2(Serie)+026(25O)+1(bobina AC)+AP(230V)+00(Standard build)
  2. Potrivire curentă:25A AC-3 =11kW@400V;40A AC-1 for resistive heating loads
  3. Replacement rule:Direct drop-in swap from 3RT1026-1AP00 without mounting hole modification
  4. Terminal option:00=Screw terminal;60=Spring-cage terminal per site requirement

VII. Ghid de depanare

Fault SymptomRoot CauseRemedy
Contactorul nu reușește să tragăNo/low coil supply voltageCheck control circuit & measure coil input voltage
Excessive operating humDust/oil contamination on core pole faceClean core surface, inspect short-circuit ring
Severe contact erosionOverload or frequent switchingUpgrade to higher rating contactor & optimize control logic
Bobina supraîncălzităOvervoltage or high ambient temperatureStabilize input voltage & improve cabinet ventilation
Poor auxiliary contact conductionContact oxidation or mechanical wearCurățați contactele; replace contactor if heavily worn

VIII. Conformitatea transportului aerian & Certificari

Shipping Classification: Non-hazardous goods, fara baterie cu litiu incorporata, compliant with IATA DGR

CE Approval: Conform EN 60947-4-1, Cert No.:CE 0123

UL Approval: Complies with UL 508, File No.:E249461

Conformitate RoHS: Conforms to Directive 2011/65/EU, restricted hazardous substance free

  1. Order Information

Cod de comandă:3RT2026-1AP00

Minimum Pack Quantity:1 unit per carton

Perioada de garanție:12 luni

Recommended Spare Parts:3RU2016-1CB00(releu termic de suprasarcina),3RH2111-1AP00(auxiliary contact block)

Application Scope of Siemens 3RT2026-1AP00 (AC-3 25A@400V, 11kW, 230V AC Coil, 1NO+1NC Aux. Contacte)

Rated Application: 3-phase motor ≤11kW@400V; Resistive load max.40A(AC-1), Montare pe șină DIN, 230VAC control circuit as standard.

  1. Priority Application Industries & Segments

1.1 HVAC & Aer condiționat (Largest consumption volume)

  1. Cabinet air-conditioner & condenser fans:2.2~7.5kW centrifugal blowers
  2. Fresh air handlers, smoke exhaust & fire supplementary fans:3~11kW 3-phase fans
  3. Cooling tower & chilled water circulation pumps (4kW/5.5kW/7.5kW)

Matching: Paired with 3RU2016 thermal relay for motor overload protection, cabinet built-in installation.

1.2 Aprovizionare cu apă & Wastewater Treatment

  1. Sewage lift pumps, self-priming pumps & chemical dosing agitator pumps (1.5~11 kW)
  2. Raw water booster pumps & filter backwash pumps for water purification plants
  3. Residential secondary water supply booster pumps, duty-standby start-stop control(single pump ≤11kW)

1.3 Food Packaging & Light Industry Automation

  1. Packaging machine belt & film winding motors (0.75~5,5 kW)
  2. Dough mixers & filling agitator motors
  3. Roller drive motors for filling production line & conveyor start-stop control

1.4 Prelucrarea lemnului & Small Machine Tools

  1. Sanders, bench saws & drill spindle motors (3~7,5 kW)
  2. Air compressor host control for 7.5kW/11kW screw & piston compressors

1.5 Logistică & Warehouse Conveying Equipment

  1. Belt & roller conveyor drive motors (1.5~7,5 kW)
  2. Small lifting equipment drive motors (motor load ≤11kW)
  3. Power control for mini shuttle machines in automated warehouses

1.6 Clădire & Civil Electrical Works

  1. Basement drainage pumps, civil defense ventilation fans, fire damper linked blowers
  2. Temporary site concrete mixers & construction dust extraction fans

1.7 Cold Chain Refrigeration

Start-stop control for cold room evaporator fans & chiller circulation pumps (3~7,5 kW)

  1. Resistive Load Applications (AC-1:40A Max.)

Direct usage for heating tubes, drying oven heating circuits, incandescent lamp banks & cabinet space heaters; total single/3-phase resistive load ≤40A.

  1. Non-Recommended Operating Conditions
  2. High-frequency jogging (>60 cicluri/min): Welders & frequent forward/reverse machines lead to rapid contact burnout; adopt dedicated AC-4 contactor instead
  3. Motors over 11kW@400V: Upgrade to higher rating 3RT2035/3RT2045 series
  4. Severe corrosive atmosphere (electroplating, strong acid chemical workshop): Sealed anti-corrosion type required
  5. Heavy vibration environment(minerit, vehicle-mounted construction machinery): Anti-vibration base or vehicle-specific contactor needed to avoid accidental coil dropout
  6. High-power DC loads (DC motor & battery circuit): Specially designed DC-coil DC contactor required
  7. Standard Matching Control Schemes
  8. Basic motor control circuit: 3RT2026-1AP00 + 3RU2016 thermal relay + 230VAC pushbutton start-stop
  9. Star-Delta starter: Same model contactor for main & star-point connections (star-delta startup for motor ≤11kW)

Prev: