Это АББ F200 Series 4-pole Type B Автомат защити цепи остаточного тока (УЗО) with a rated current of 63A and a rated residual operating current of 30mA. This model is obsolete. The original manufacturer replacement part number is 2CSF204568R1630 (F204B-63/0.03-4TE). It is designed for industrial applications equipped with frequency converters, UPS and other devices, and provides protection against smooth DC leakage current.
- Пояснение кода модели
| Модельный сегмент | Определение | Подробное описание |
| F204 | Base Model | F200 Series, 4-pole residual current circuit breaker |
| Б | Тип остаточного тока | Тип Б, capable of detecting AC, pulsating DC and smooth DC residual current (0-1000Гц) |
| 63 | Номинальный рабочий ток | 63А, continuous current rating |
| 0.03 | Номинальный остаточный рабочий ток | 0.03A = 30mA, high-sensitivity protection against direct human contact |
| 2CSF204592R1630 | Код заказа | Unique official ABB identification code for purchasing and traceability |
| 4ТО | Тип монтажа | Standard DIN rail mounting with 4-pole terminals (marked on partial versions) |
- Основные технические характеристики
| Категория | Технические данные | Примечания |
| Основные характеристики | ||
| Тип продукта | Автомат защити цепи остаточного тока (УЗО) | No overload or short-circuit protection; must be used with MCB |
| Ряд | System pro M compact® F200 | ABB modular power distribution product line |
| поляки | 4П (Л1, Л2, Л3, Н) | Protection for 3-phase 4-wire systems |
| Номинальное напряжение | 400В и (50/60Гц) | Operating voltage range: 380-415В |
| Номинальный ток (В) | 63А | Compliant with IEC/EN 61008-1 |
| Номинальный остаточный рабочий ток (IΔn) | 30мА | Instantaneous type (no time delay) |
| Тип остаточного тока | Тип Б | Comprehensive protection against AC, pulsating DC and smooth DC leakage current |
| Параметры производительности | ||
| Разрывная способность (IΔm) | 3тот | Breaking capacity under rated conditions |
| Время работы | ≤0.04s @ IΔn=30mA | Meets requirements for rapid personal safety protection |
| Rated Residual Non-operating Current (IΔno) | 15мА | No tripping below this value to avoid nuisance tripping |
| Кнопка тестирования | Встроенный | For regular functional testing |
| Физические характеристики | ||
| Размеры (Ш × В × Г) | 70mm × 85mm × 60mm | Стандартная модульная конструкция, occupies 4 module units |
| Монтаж | 35мм DIN-рейка | Compliant with EN 50022 |
| Тип терминала | Bi-directional cylindrical terminals | Facilitates cable connection and enhances safety |
| Масса | Приблизительно. 360г | Weight per unit |
| Среда & Сертификаты | ||
| Рабочая температура | -25°C ~ +55°C | Performance may be affected beyond this range |
| Температура хранения | -40°С ~ +85°С | |
| Влажность | 5% ~ 95% (неконденсирующийся) | |
| Защита от проникновения | IP20 | Finger-proof, not suitable for outdoor use |
| Сертификаты | МЭК/EN 61008-1, МЭК/EN 61008-2-1 | CE certified, complies with international safety standards |
| Lifecycle Status | ||
| Статус | Obsolete | Stock still available via some distributors |
| Discontinued Date | Jun-24 | Official record |
- Полный список моделей (F204 Type B)
| Модель | Код заказа | Номинальный ток | Rated Residual Current | Функции |
| F204 B-25/0.03 | 2CSF204592R1250 | 25А | 30мА | 4-pole Type B, basic model |
| F204 B-40/0.03 | 2CSF204592R1400 | 40А | 30мА | 4-pole Type B, medium current |
| F204 B-63/0.03 | 2CSF204592R1630 | 63А | 30мА | 4-pole Type B, standard industrial model |
| F204 B-63/0.1 | 2CSF204592R2630 | 63А | 100мА | 4-pole Type B, higher sensitivity |
| F204 B-63/0.3 | 2CSF204592R3630 | 63А | 300мА | 4-pole Type B, equipment protection |
| F204 B-63/0.5 | 2CSF204592R4630 | 63А | 500мА | 4-pole Type B, system protection |
| F204 B-80/0.03 | 2CSF204592R1800 | 80А | 30мА | 4-pole Type B, high current |
| F204 B-100/0.03 | 2CSF204592R1100 | 100А | 30мА | 4-pole Type B, extra high current |
| F204 B-125/0.03 | 2CSF204592R1125 | 125А | 30мА | 4-pole Type B, maximum current |
| F204 B-63/0.03-4TE | 2CSF204568R1630 | 63А | 30мА | Replacement model, 4-pole Type B, standard terminals |
- Решения по замене & Cross-Brand Equivalents
4.1 Original Manufacturer Replacements
| Оригинальная модель | Запасная модель | Причина замены | Совместимость |
| F204 B-63/0.03 (2CSF204592R1630) | F204 B-63/0.03-4TE (2CSF204568R1630) | Product upgrade with optimized terminal design | Fully compatible, прямая замена |
| DDA204 B-63/0.03 AP-R (2CSB204592R1630) | FI-Block series, integrated design | Identical mounting dimensions and functions |
4.2 Cross-Brand Compatible Replacements
| Бренд | Модель | Technical Matching Rate | Примечания |
| Шнайдер | iC60H RCCB 4P 63A 30mA Type B | 95% | Dimensionally compatible, equivalent performance |
| Сименс | 5SU1356-6KK63 | 90% | Slight difference in tripping characteristics |
| Legrand | 4102 63 03 Б | 90% | Different wiring terminals |
| Чинт (Китай) | NXBLE-400/4P 63A 30mA Type B | 85% | Cost-effective with complete certifications |
- Среды приложений & Typical Cases
5.1 Recommended Applications
Системы промышленной автоматизации: Frequency converters, сервоприводы, Шкафы ПЛК; protects against smooth DC leakage current.
Медицинское оборудование: Operating rooms, ICU devices; provides top-level leakage protection.
Дата-центры: Системы ИБП, server cabinets; prevents nuisance tripping caused by power fluctuation.
Renewable Energy: Фотоэлектрические инверторы, системы хранения энергии; protects DC side leakage.
Коммерческие здания: Kitchen equipment, central air conditioning, elevator control systems; protection for 3-phase loads.
5.2 Non-Recommended Applications
Pure residential single-phase loads: Type B is overqualified; Type AC is sufficient.
Outdoor humid environments: IP20 rating is inadequate; additional enclosure protection required.
Explosive hazardous areas: Explosion-proof products must be used.
Applications requiring overload/short-circuit protection: This unit only provides leakage protection and shall be used together with MCB.
5.3 Типичные случаи применения
Случай 1: Automotive Manufacturing Workshop
Equipment: Robotic welding systems, converter-driven production lines
Проблема: Frequent nuisance tripping of conventional Type AC RCCBs affected production.
Решение: Install F204 B-63/0.03 to protect against smooth DC leakage generated by converters.
Результат: Nuisance tripping rate reduced by 90%, production efficiency improved by 15%.
Случай 2: Hospital Operating Room
Equipment: Anesthesia machines, patient monitors, surgical lights
Requirements: Highest safety level, zero nuisance tripping and fast response.
Решение: Adopt F204 B-63/0.03 combined with S204-B63 MCB.
Результат: Complies with medical equipment safety standards and ensures operational safety.
- Поиск неисправностей & Maintenance Manual
6.1 Распространенные неисправности & Решения
| Явление неисправности | Возможные причины | Действия по устранению неполадок |
| Частые отключения | 1. Actual circuit leakage | 1. Test circuit insulation with megohmmeter after power off |
| 2. DC leakage from loads | 2. Verify if loads require Type B RCCB | |
| 3. Product aging | 3. Check production date; replace if service life exceeds 10 годы | |
| 4. Ослабленные клеммы проводки | 4. Retighten wiring terminals | |
| Failure to trip | 1. Повреждена кнопка тестирования | 1. Replace test button assembly |
| 2. Internal trip mechanism fault | 2. Send for repair or replace the unit | |
| 3. Неправильная проводка (neutral wire disconnected) | 3. Check wiring and ensure neutral wire is properly connected | |
| Cannot be reset | 1. Mechanical lock failure | 1. Manually reset after power off; replace if failed |
| 2. Persistent leakage | 2. Eliminate leakage fault before resetting | |
| 3. Чрезмерно высокая температура окружающей среды | 3. Improve ventilation and lower ambient temperature | |
| Indicator light off | 1. Damaged indicator lamp | 1. Replace indicator lamp |
| 2. Internal circuit fault | 2. Send for repair or replace the unit |
6.2 Maintenance Procedures
- Routine Inspection (Ежемесячно)
Visually inspect for damage or discoloration.
Press test button to confirm normal tripping and reset.
Check terminals for looseness and overheating marks.
- Periodic Maintenance (Ежегодно)
Clean unit surface with dry soft cloth after power cut.
Check firmness of DIN rail mounting.
Measure insulation resistance (≥1MΩ).
Record test results.
- Replacement Cycle
Normal operating conditions: 10 годы
Суровые условия (высокая температура / высокая влажность): 5~7 years
Frequent tripping conditions: 3~5 years
6.3 Quick Diagnosis Tips
Type B RCCB handles DC leakage well.
Check wiring first for frequent tripping; load type matters most.
Replace unit immediately if test button malfunctions.
Power off and clear faults before resetting.
Replace after 10 years for reliable safety.
- Рекомендации по выбору
- Residual Current Type Selection: Choose Type B for systems with converters, UPS or medical devices; Type AC for general lighting and sockets; Type A for pulsating DC loads.
- Rated Current Selection: Номинальный ток ≥ 1.2 times total load current. 63A is suitable for most industrial control cabinets.
- Residual Current Rating Selection: 30мА для индивидуальной защиты; 100~300mA for equipment protection; 500mA~1A for system protection.
- Выбор полюса: 2P for single-phase systems; 3P for 3-phase 3-wire systems; 4П (с нейтральным проводом) for 3-phase 4-wire systems.
- Replacement Principle: Prioritize upgraded models from the same series for obsolete products to guarantee identical dimensions and performance.