Шинная вилка ABB PDP22-FBP - Контактор,автоматический выключатель,датчик,Кодер,ПЛК,Конвертер

Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

 Шинная вилка ABB PDP22-FBP - Контактор,автоматический выключатель,датчик,Кодер,ПЛК,Конвертер

электрический/

Шинная вилка ABB PDP22-FBP

PROFIBUS DP-V1 FieldBusPlug Overview: ABB FBP series PROFIBUS DP-V1 bus plug (bus adapter). It connects FBP-enabled motor controllers to PROFIBUS DP network, supporting DP-V1 (extended diagnostics), which differentiates it from the legacy PDP21-FBP (DP-V0 only). Typical compatible devices: UMC100-FBP, UMC22-FBP, FBP motor starters, MCC drawer units ✅ Model suffix definition (длина кабеля) PDP22-FBP.025: 0.25 м ...

  • Подробная информация о продукте

PROFIBUS DP-V1 FieldBusPlug

Обзор: ABB FBP series PROFIBUS DP-V1 bus plug (bus adapter). It connects FBP-enabled motor controllers to PROFIBUS DP network, supporting DP-V1 (extended diagnostics), which differentiates it from the legacy PDP21-FBP (DP-V0 only).

Typical compatible devices: UMC100-FBP, UMC22-FBP, FBP motor starters, MCC drawer units

✅ Model suffix definition (длина кабеля)

PDP22-FBP.025: 0.25 м

PDP22-FBP.050: 0.5 м (Номер детали.: 1SAJ240100R1005)

PDP22-FBP.100: 1 м

PDP22-FBP.200: 2 м

PDP22-FBP.500: 5 м (Номер детали.: 1SAJ240100R1050)

📌 Core Technical Specifications

Bus protocol: PROFIBUS DP-V0 / DP-V1 (DP-V1 supports acyclic read/write and extended diagnostics)

Скорость передачи данных: До 12 Мбит/с, PROFIBUS certified slave

Источник питания: 24 В Вашингтоне, потребляемая мощность ок.. 0.9 Вт

Bus connector: A-coded M12

Класс защиты: IP65 (suitable for cabinet exterior and MCC drawer application)

Индикация: Статус / diagnostic LED

Монтаж: Direct plug-in to FBP device port, Монтаж на DIN-рейку не поддерживается

Сертификаты: CE, кУЛ; Соответствует RoHS

Код ТН ВЭД: 85176200

✨ Key Advantages for MCC Drawers

Separable bus plug and control unit: The bus node remains online when the drawer is pulled out, without disrupting communication of other stations on the bus, ideal for MCC maintenance.

Factory pre-assembled cable with crimped terminals, reduces on-site wiring errors.

Matching GSD file: `ABB_34e0.gsd` (for UMC100-FBP), included in the PBE91-FBP engineering package.

🆚 Comparison within the same family

  1. PDP21-FBP: DP-V0 only, no DP-V1 extended diagnostics, постепенно выведено из употребления
  2. PDP22-FBP: DP-V0+DP-V1 with extended diagnostics, mainstream active model
  3. PDQ22-FBP: Same DP-V1 protocol, DIN rail mount version, no prefabricated cable

⚠️ Выбор & Примечания по устранению неполадок

  1. Back-end equipment must be equipped with native FBP interface (standard UMC100 without FBP interface is incompatible).
  2. Cable length selection: PROFIBUS specification limits branch length; M12 branch cables should not be excessively long.
  3. LED diagnostic guide:

Горит постоянно: Bus online, normal operation

Мигает: Ошибка связи / duplicate station address / несоответствие скорости передачи данных

ВЫКЛЮЧЕННЫЙ: Missing 24V DC supply

  1. Варианты замены: PDQ22-FBP (DIN rail version) for equivalent DP function; MRP21-FBP for Modbus RTU migration.

Сименс / Феникс Контакт / Weidmüller conventional DP-V1 connectors are merely RS485 wiring adapters. PDP22-FBP is an ABB FBP-system-specific PROFIBUS DP-V1 slave adapter with built-in protocol stack, GSD support and data parsing, not a simple wiring connector.

  1. Interface System (Основное отличие)

PDP22-FBP: Rear side is ABB proprietary FBP neutral interface (not standard DP/RS485). Only compatible with FBP devices: UMC100-FBP, UMC22-FBP, FBP motor starters. Front side is A-coded M12 PROFIBUS.

FBP design concept: The motor controller itself has no bus chip; all bus logic resides inside the plug. To change bus type, simply replace the plug (DP to Modbus / Девайснет, use MRP21 / DNP21 directly while keeping the controller unchanged).

Third-party DP-V1 connectors (Siemens 6ES7972, Феникс Контакт, Вайдмюллер): Rear side is standard DB9 / М12, connecting to devices with native RS485/DP port. The device itself integrates the DP protocol stack; the connector only performs signal routing, termination resistor switching and shielding.

⚠️ Not interchangeable: Standard DP connectors cannot mate with FBP port; PDP22 cannot connect to standard inverters or instruments with native DP port.

  1. Функциональное позиционирование: Built-in Slave Protocol Stack vs Passive Adapter

PDP22-FBP: Embedded DP-V1 slave protocol chip, it is a PROFIBUS slave by itself. It communicates with the back-end FBP device via dedicated serial link and encapsulates data into DP-V1 telegrams for the bus. It requires GSD file `ABB_34e0.gsd` for PLC configuration.

Supports DP-V1 acyclic access and extended diagnostics; fault information such as overload, phase loss and earth fault from the FBP device is forwarded by PDP22.

Conventional DP connectors: Passive or simple active adapters, no protocol stack and no GSD file. The protocol stack is hosted in the inverter / инструмент / IO module; the connector only handles wiring and termination.

  1. Unique MCC Drawer Feature (ABB Strength)

PDP22-FBP: Plug and drawer can be separated. The bus node stays online when drawer is extracted, bus communication remains intact, which is highly beneficial for MCC maintenance without affecting other stations.

Standard DP connectors: Hard-linked to the device. Removing the device disconnects the bus node and breaks the daisy-chain topology.

  1. Аппаратное обеспечение, Власть & Топология

PDP22-FBP: 24 V DC powered, 0.9 W power consumption, IP65, factory fixed-length prefabricated cables (0.25/0.5/1/2/5 м), no built-in termination resistor; termination resistor is fitted at the end M12 connector. Топология: Branch type following FBP system specification.

Siemens DB9 DP connector: IP20 cabinet use, built-in toggle termination resistor, no external 24V supply required. Most Phoenix Contact M12 DP connectors are passive, powered by bus differential signal; typical daisy-chain straight topology.

  1. Diagnostic LED

PDP22-FBP: LED indicates both bus status and back-end FBP device communication status, to distinguish bus fault from internal motor controller fault.

LED on conventional DP connectors: Mostly only indicates bus signal status, cannot view internal diagnostics of the connected device.

  1. Выбор & Replacement Boundary
  2. For ABB FBP MCC and UMC100-FBP applications: Only PDP22-FBP / PDQ22-FBP are valid; standard Siemens DP connectors cannot substitute.
  3. For standard inverters, инструменты, third-party IO with native DP port: Use Siemens / Phoenix Contact DP connectors, PDP22 is not applicable.
  4. Family comparison: PDQ22-FBP is DIN rail mount, поддержка до 4 FBP units; PDP22 is single-channel with prefabricated outgoing cable.
  5. Сравнительная таблица
ЭлементABB PDP22-FBPСименс / Phoenix Contact DP-V1 Connector
NatureDP-V1 slave adapter (with protocol stack)RS485 wiring connector
Rear interfaceABB proprietary FBP interfaceStandard DB9 / M12 PROFIBUS
Источник питания24 V DC requiredPassive, no external power
GSD fileДа, ABB_34e0.gsdНет, GSD belongs to the end device
MCC drawer hot-swapПоддерживается, drawer removal does not break bus nodeНе поддерживается, removing device disconnects node
Termination resistorNot integrated, fitted at bus endBuilt-in switchable termination resistor
Класс защитыIP65, suitable for drawer outside cabinetMainly IP20 (DB9 version)
Applicable devicesUMC100-FBP, FBP motor startersAll devices with native PROFIBUS DP port

Распространенная ошибка

Many users mistake PDP22-FBP as a simple M12 DP plug and try connecting it to standard DP instruments, resulting in communication failure. The core principle: FBP is a bus-separated architecture, bus logic is implemented in the plug, while the motor controller only performs I/O and protection functions.

  1. Full Model List for PDP22-FBP Series (PROFIBUS DP-V1, single-channel prefabricated cable version)
МодельДлина кабеляOrder Part No.ПротоколМонтаж
PDP22-FBP.0250.25 м1SAJ240100R1003DP-V0+DP-V1Direct plug-in to FBP port, no DIN rail
PDP22-FBP.0500.50 м1SAJ240100R1005DP-V0+DP-V1Direct plug-in to FBP port, no DIN rail
PDP22-FBP.1001.00 м1SAJ240100R1010DP-V0+DP-V1Direct plug-in to FBP port, no DIN rail
PDP22-FBP.2002.00 м1SAJ240100R1020DP-V0+DP-V1Direct plug-in to FBP port, no DIN rail
PDP22-FBP.5005.00 м1SAJ240100R1050DP-V0+DP-V1Direct plug-in to FBP port, no DIN rail

Legacy discontinued model: PDP21-FBP (DP-V0 only, no V1 diagnostics), available in same lengths .025/.050/.100/.200/.500, replaced by PDP22-FBP.

  1. DP Family: PDQ22-FBP (Multi-port DIN rail version, same DP-V1 protocol)
МодельКоличество портовOrder Part No.Функции
PDQ22-FBP.04 FBP channels (1 DP node)1SAJ240200R0050Крепление на DIN-рейку, 1 station address for up to 4 UMC-FBP, IP65

III. Complete FBP Bus Plug Family (Same FBP interface, different fieldbus protocols)

1) ПРОФИБУС ДП (Current Series)

  1. PDP21-FBP: DP-V0 (Снято с производства)
  2. PDP22-FBP: DP-V0/V1, single-channel prefabricated cable (table above)
  3. PDQ22-FBP: DP-V0/V1, 4-port DIN rail type

2) Модбус РТУ

MRP21-FBP (025/050/100 длина, Номер детали. 1SAJ250000Rxxxx)

3) Девайснет

DNP21-FBP (025/050/100 длина, Номер детали. 1SAJ230000Rxxxx)

4) CANopen

COP21-FBP (025/050/100 длина, Номер детали. 1SAJ230100Rxxxx)

5) Ethernet

MTQ22-FBP (ЭтерНет/IP / Модбус TCP, FBP Ethernet adapter)

  1. Matching DP Accessories for PDP22 / PDQ22
  2. PDX11-FBP extension cable: 050/100/300/500 (0.5/1/3/5 м)
  3. PDR11-FBP.150: 150Ω termination resistor
  4. PDA11-FBP.050: DB9 to M12 adapter
  5. CDA11-FBP.0: PDQ22 DIN rail mounting bracket
  6. Правило именования модели (PDP22-FBP)

PDP = PROFIBUS DP

22 = DP-V1 version (21 = DP-V0 legacy version)

FBP = FieldBusPlug (ABB proprietary neutral interface)

Суффикс .025/.050 = cable length (метр)

Предыдущий:

Следующий:

Оставить ответ

Оставить сообщение