Finder 7S.14.9.024.0220 Forced Guided Contact Safety Relay Module

Finder 7S.14.9.024.0220 Forced Guided Contact Safety Relay Module Model Code Interpretation Segment Code Meaning Series Code 7S Finder 7S series forced guided contact safety relay module, соответствует EN 50205:2002 Type A Contact Configuration 14 4-столб, 2 Нормально открытый + 2 Normally Closed contacts Mounting & Терминал 9 Монтаж на DIN-рейку, cage-clamp terminal, 22.5ширина мм ...

  • Подробная информация о продукте

Finder 7S.14.9.024.0220 Forced Guided Contact Safety Relay Module

  1. Интерпретация кода модели
СегментКодЗначение
Код серииFinder 7S series forced guided contact safety relay module, соответствует EN 50205:2002 Тип А
Конфигурация контактов144-столб, 2 Нормально открытый + 2 Normally Closed contacts
Монтаж & Терминал9Монтаж на DIN-рейку, cage-clamp terminal, 22.5ширина мм
Напряжение катушки2424V DC control coil
Версия & Особенность220Standard version without extra functions
  1. Core Specification Table
КатегорияПараметрПримечания
Basic Info
ПроизводительFinderFamous Italian relay brand
Тип продуктаForced guided contact safety relay moduleNon-latching type
Номер заказа7S.14.9.024.0220 / 7S1490240220Two formats are both applicable
Электрические параметры
Напряжение катушки24В ВашингтонеStandard industrial control voltage
Потребляемая мощность катушки1.2ВтTypical value
Contact Arrangement2НО+2НЗ (4П)Forced guided design for synchronous contact operation
Номинальный ток6A @ 250V AC (АС-1)Rated value for different load types
6A @ 30V DC (DC-1)
3A @ 230V AC (АС-15)
Контактный материалAgNi Silver Nickel AlloyHigh conductivity and wear resistance
Механический & Параметры окружающей среды
Тип установкиDIN-рейка (В 60715)22.5mm compact width
Тип терминалаCage-clampScrewless wiring, простая установка
Protection GradeIP20Finger-proof, suitable for cabinet interior
Рабочая температура-40°С ~ +70°СWide temperature range for industrial use
Температура хранения-40°С ~ +85°С
СертификацияВ 50205:2002 Тип А, В 13849-1International safety relay standards
Срок службыМеханический: 10⁷ operations
Электрический: 10⁵ operations at rated load
  1. Cross-brand Replacement Reference
БрендМодельSimilaritiesРазличия
ГрибPNOZ X2.8P 24VDC2НО+2НЗ, 24В постоянного тока, forced guided contactProfessional safety relay, higher price and richer functions
Сименс3TK2825-1BB402НО+2НЗ, 24В постоянного тока, DIN rail mountBetter compatibility in industrial automation
ШнайдерZelio SR2B121BD2НО+2НЗ, 24В постоянного тока, forced guided contactDifferent terminal design, экономически эффективный
ОмронG9SA-321-T0752НО+2НЗ, 24В постоянного тока, safety certifiedКомпактный размер, ideal for limited space
  1. 7S Series Main Model List
МодельContact LayoutНапряжение катушкиТип терминалаСпециальная функция
7S.12.9.024.02202П (1НО+1НЗ)24В ВашингтонеCage-clampСтандартный
7S.14.9.024.02204П (2НО+2НЗ)24В ВашингтонеCage-clampСтандартный (this product)
7S.16.9.024.02206П (3NO+3NC)24В ВашингтонеCage-clampСтандартный
7S.14.9.230.02204П (2НО+2НЗ)230В иCage-clampСтандартный
7S.14.9.024.42204П (2НО+2НЗ)24В ВашингтонеCage-clampLED status indicator
7S.14.9.024.52204П (2НО+2НЗ)24В ВашингтонеВинтовой терминалСтандартный
7S.34.9.024.02204П (2НО+2НЗ)24В ВашингтонеCage-clamp10Номинальный ток
  1. Поиск неисправностей & Руководство по техническому обслуживанию

5.1 Common Fault Analysis

Явление неисправностиВозможные причиныInspection Steps
Coil fails to pull in1. Insufficient or reversed coil voltage1. Measure coil voltage to confirm 24V DC
2. Burnt coil2. Test coil resistance (normal: approx 480Ω)
3. Ослабленная проводка3. Check terminal tightness
No contact movement1. Jammed forced guided mechanism1. Check mechanical flexibility after power off
2. Oxidized or burnt contacts2. Inspect contact surface damage
3. Mechanical wear3. Verify contact travel distance
Контактное прилипание1. Arc burn caused by overload or short circuit1. Check actual load exceeding rating
2. Contact material fatigue2. Replace relay module
LED indicator off1. Damaged LED1. Check power supply connection
2. Power disconnection2. Replace with identical module for test
3. Internal circuit failure

5.2 Обслуживание & Replacement Suggestion

  1. Safety Priority: Cut off power and wait at least 5 minutes for capacitor discharge before maintenance.
  2. Модульная структура: On-site repair is not recommended; integral replacement is preferred.
  3. Процедура замены

Record wiring positions by photos or sketches

Remove old module from DIN rail

Install new module and reconnect wires accordingly

Power on and verify normal operation

  1. Preventive Maintenance

Inspect terminal connection every 6 месяцы

Avoid overload, reserve 30% current margin

Shorten replacement cycle to 2-3 years under harsh conditions

  1. Сценарии применения & Industry Cases

6.1 Applicable Fields

ПромышленностьТипичное применениеSafety Function
Machinery ManufacturingEmergency stop circuit, safety door monitoringPrevent accidental startup, protect operators
Automatic Production LineSafety light curtain, two-hand control circuitSecure operating area safety
Elevator & EscalatorDoor lock monitoring, safety loopAvoid unexpected elevator movement
Железнодорожный транзитDoor control, braking systemComply with railway safety standards
Packaging MachineryGuardrail monitoring, аварийная остановкаPersonnel injury prevention

6.2 Inadmissible Working Conditions

High vibration environment such as stamping machines, shockproof bracket required

Humid and dusty environment, IP54+ sealed enclosure needed

Ultra-high frequent switching over 10 cycles per minute, solid state relay recommended

High current load over 6A / 250В и, contactor required for capacity expansion

6.3 Selection Tips & Avoidance Notes

  1. Distinguish forced guided contact from ordinary relay; В 50205 compliant type mandatory for safety application
  2. Confirm coil voltage, avoid AC and DC confusion; this model is 24V DC
  3. Match load type with corresponding rated current (AC-1/AC-15/DC-1)
  4. Reserve enough installation space for 22.5mm width module
  5. Ensure compliance with EN 13849-1 for industrial safety usage

Application Scenarios of Finder 7S.14.9.024.0220

Equipped with forced guided safety contacts, conforming to EN13849 and EN50205 safety standards, applied for equipment safety loop control.

  1. General Industrial Machinery
  2. Machine tools: Emergency stop circuit, safety door interlock, tool magazine safety lock
  3. Stamping & forging machines: Guard fence detection, slide safety limit
  4. Машины для литья под давлением: Mold safety door, manipulator area protection interlock
  5. Automatic Production Line
  6. Conveyor line: Light curtain safety protection, station access judgment
  7. Assembly equipment: Two-hand startup circuit, robot fence access control
  8. Sorting & упаковочные машины: Flip cover protection, fault emergency stop interlock
  9. Лифтинг & Hoisting Equipment
  10. Small lift, cargo elevator door control safety circuit
  11. Crane lifting tool limit protection, power-off safety lock
  12. Light Industry & Special Machinery
  13. Safety stop interlock for printing and textile machinery
  14. Safety door monitoring for wood cutting equipment
  15. Fault power-off protection for fans and water pumps
  16. Транспорт & Building Auxiliary
  17. Automatic door and escalator safety detection circuit
  18. Vehicle industrial control, miniature railway equipment safety protection
  19. Control Cabinet Internal Control
  20. System emergency power-off safety loop
  21. High voltage cabinet access control and leakage safety interlock

Unsuitable Environments

Non-sealed cabinet with strong corrosion and heavy dust

Ultra-high frequency switching working condition

Working current exceeding 6A rated load