Siemens QPL25.050B is a high-performance gas pressure switch. Designed for medium and low pressure monitoring ranging from 5-50 mbar, it features IP54 protection grade and a mechanical service life of 100,000 циклы. It is widely used for safety protection of combustion systems. Check model parameters, pressure range and mounting interface during procurement to ensure full compatibility with system requirements.
- Model Code Definition
| Сегмент кода | Значение | Описание |
| QPL | Код серии продукта | Basic series of Siemens gas pressure switches for gas and air pressure monitoring |
| 25 | Структура & rated parameters | Ряд 25, rated current 6A AC, rated voltage 250V AC/DC, IP54 protection |
| 50 | Pressure adjustment range | Adjustable range: 5-50 mbar (0.5-5.0 kPa) |
| Б | Version mark | Стандартный тип, автоматический сброс, SPDT contact configuration |
- Основные параметры спецификации
| Категория | Технические характеристики | Примечания |
| Основные параметры | ||
| Тип продукта | Mechanical gas pressure switch | Safety monitoring for combustion systems |
| Номер заказа. | 1117087 | Official Siemens part number |
| Adjustment Range | 5-50 mbar (0.5-5.0 kPa) | Adjustable set point |
| Max Working Pressure | 690 mbar (69 kPa) | Upper limit of continuous operating pressure |
| Switch Differential | Приблизительно. 5-10 mbar | Pressure difference between switch-on and switch-off |
| Электрические параметры | ||
| Номинальное напряжение | 250 В переменного тока / DC 250V | Максимальное рабочее напряжение |
| Номинальный ток | AC 6A / DC 1A | резистивная нагрузка |
| Тип контакта | SPDT | 1 нормально открытый + 1 нормально закрытый |
| Электрическое соединение | Terminal box compliant with DIN EN 175 301-803 | Сорт 3 защита изоляции |
| Механический & Параметры окружающей среды | ||
| Pressure Port | G1/4 internal thread (ISO228) | Center position at bottom casing |
| Measuring Port | Ø9mm, 10mm length with locking screw | For pressure calibration |
| Температура окружающей среды | -20°С ~ +60°С | Диапазон рабочих температур |
| Medium Temperature | -40°С ~ +60°С | Applicable gas temperature |
| Protection Grade | IP54 | Пыленепроницаемый и водонепроницаемый |
| Mechanical Lifespan | 100,000 циклы | Switch actuation times |
| Applicable Media | Сорт 1/2/3 gases & non-corrosive gas | Natural gas, liquefied petroleum gas, и т. д.. |
- Full QPL25 Series Model List
| Модель | Pressure Range | Max Working Pressure | Примечания |
| QPL25.003B | 0.3-3 mbar | 690 mbar | Low pressure monitoring |
| QPL25.010B | 1-10 mbar | 690 mbar | Ultra-low pressure application |
| QPL25.050B | 5-50 mbar | 690 mbar | Standard medium-low pressure |
| QPL25.150B | 15-150 mbar | 690 mbar | Medium pressure monitoring |
| QPL25.500B | 100-500 mbar | 720 mbar | High pressure monitoring |
- Cross-brand Replacement Comparison
| Бренд | Модель | Pressure Range | Основные различия | Replacement Suggestion |
| Сименс | QPL25.050B | 5-50 mbar | Original authentic product, high stability | Priority choice |
| Honeywell | C6097A | 5-50 mbar | Сниженная цена, similar response speed | Прямая замена |
| Данфосс | KPI 36 | 5-50 mbar | Different mechanical structure, high adjustment precision | Verify mounting dimensions |
| Dungs | LGW50A2 | 5-50 mbar | German brand, надежное качество | Fully compatible |
| Baltur | PAMPA | 5-50 mbar | Burner dedicated, экономически эффективный | Suitable for Baltur combustion systems |
- Распространенное устранение неполадок & Обслуживание
5.1 Распространенные неисправности & Причины
| Явление неисправности | Возможные причины | Troubleshooting Steps |
| No switch action under normal pressure | Improper setpoint; oxidized/damaged contacts; aging/damaged diaphragm; свободная проводка | Recalibrate setpoint; test contact continuity; inspect diaphragm; fasten terminals |
| No switching under abnormal pressure | Excessive switch differential; mechanical stuck; spring fatigue | Adjust differential; clean moving parts; replace spring assembly |
| Frequent contact ablation | Перегрузка; unstable voltage; mismatched contact material | Check load current; install surge suppressor; replace contact assembly |
| Inaccurate pressure reading | Blocked measuring port; deformed diaphragm; calibration error | Clean port; replace diaphragm; recalibrate with standard pressure source |
5.2 Рекомендации по техническому обслуживанию
- Safety Precaution
Cut off gas supply and release pressure
Disconnect power supply
Cool down equipment to room temperature
- Calibration Procedure
① Remove protective cover and locate adjusting screw
② Connect standard pressure source and set target value
③ Clockwise rotation increases set pressure, counter-clockwise decreases
④ Test switching action and confirm accurate trigger point
⑤ Reinstall cover and ensure tight sealing
- Component Replacement
Diaphragm: Dismount with special tools, pay attention to gasket installation direction
Контакт: Replace whole switch module instead of single contact
Spring: Use identical specification spare part to guarantee precision
- Application Environment & Industry Cases
6.1 Применимые сценарии
✅ Recommended Applications
Safety monitoring for industrial & civil gas burners
Pressure protection system of gas boilers
Pressure control of natural gas pipelines
Gas supply system of industrial furnaces
Pressure monitoring for biogas power generation equipment
❌ Inadmissible Applications
High-pressure gas system over 690 mbar
Corrosive gas atmosphere
Medium temperature exceeding 60°C or below -20°C
Severe vibration and outdoor exposed installation without protection
6.2 Typical Industry Applications
| Промышленность | Приложение | Функция |
| ОВК | Commercial gas boiler | Monitor gas pressure to ensure combustion efficiency and safety |
| Food Processing | Baking furnace gas system | Avoid incomplete combustion caused by low pressure |
| Energy Industry | Biogas power station | Stabilize biogas pressure and protect generating units |
| Manufacturing | Ceramic kiln | Precise temperature control via gas pressure regulation |
| Commercial Kitchen | Large cooking equipment | Safety interlock to prevent gas leakage accidents |
- Selection Tips & Avoidable Risks
Мнемоника выбора
QPL series for gas service, 25 stands for 6A rating
Last three digits define pressure range, B means standard auto-reset
050 model fits 5-50 mbar, G1/4 thread for installation
IP54 solid protection, match gas medium properly
Ключевые примечания
- Pressure Matching
Keep actual working pressure within 20%-80% of adjustment range to maintain accuracy.
- Требования к установке
Mount vertically with diaphragm downward to avoid condensed water accumulation.
Install filter at pressure port to prevent internal impurity damage.
Secure wiring firmly to avoid false triggering.
- Safety Regulations
Interlock with gas leakage alarm device.
Conduct regular inspection and calibration every 6 месяцы.
Perform pressure and leakage test after maintenance.
- Purchase Notice
Choose genuine Siemens products; counterfeit items have unstable quality.
Keep original package and certificate for after-sales service.
Working Principle of QPL25.050B
Core principle: Air pressure deforms diaphragm, mechanical linkage drives contact on-off to realize overpressure interlock protection
- Pressure Sensing
Gas flows into inner chamber through G1/4 port and acts on rubber diaphragm, driving axial displacement with pressure variation.
- Mechanical Force Balance
Diaphragm thrust counterbalances preset spring tension. Rotate adjusting screw to change spring preload and set trigger pressure threshold.
- Linkage Actuation
When pressure rises to set value, diaphragm overcomes spring resistance and pushes rod to drive lever mechanism. Spring rebounds when pressure drops below threshold.
- Contact Switching
Lever movement switches SPDT contacts, reverses circuit status and transmits electric signal for burner start-stop and alarm interlock.
- Differential Pressure Stabilization
Fixed pressure differential prevents frequent switching and unnecessary equipment startup/shutdown.
- Режим сброса
Standard automatic reset; contacts recover initial state once pressure returns to normal range.
Application Scenarios of QPL25.050B
Applicable Sites
- Low pressure monitoring and protection for gas boilers and water heaters
- Supply pressure interlock control of oil and gas industrial burners
- Pressure stabilization detection for commercial kitchen stoves and hot air furnaces
- Medium-low pressure monitoring of natural gas and liquefied gas pipelines
- Safety protection for furnace and drying equipment gas supply
- Start-stop interlock for clean combustible gas such as biogas and coal gas
Forbidden Sites
- Gas pipelines with pressure higher than 690mbar
- Gas medium containing corrosion, dust and oil contaminants
- Ambient temperature below -20℃ or above 60℃
- Sites with fierce vibration and uncovered outdoor installation
Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи