Leuze BCL22S-M312 Laser Barcode Scanner

(Лозунг, not Lenze) Заказ №.: 50032097, BCL22 series fixed-mount 1D laser barcode scanner (line-scan type) Model Decoding `BCL 22 S M 312` BCL22: Серия продуктов, industrial fixed barcode reader S: Single-line scanning M: High-speed version, 1000 scans per second (N version = 800 scans/s) 312: Optical variant, reading range 50-260 mm, barcode module 0.2-0.8 mm Key Technical ...

  • Подробная информация о продукте

(Лозунг, нет Ленц)

Заказ №.: 50032097, BCL22 series fixed-mount 1D laser barcode scanner (line-scan type)

Model Decoding

`BCL 22 S M 312`

BCL22: Серия продуктов, industrial fixed barcode reader

С: Single-line scanning

М: High-speed version, 1000 scans per second (N version = 800 scans/s)

312: Optical variant, reading range 50-260 mm, barcode module 0.2-0.8 mm

Основные технические характеристики

ЭлементСпецификация
Источник света655 nm red laser, laser class 2
Scan Rate1000 scans/s
Reading Distance50 … 260 mm
Barcode Module0.2~0.8 mm
Supported BarcodesCode39/93/128, EAN‑UPC, Interleaved 2‑of‑5, Codabar, Pharmacode
Источник питанияDC 10‑30 V, Макс. 310 mA
ввод/вывод2 цифровые входы / 2 цифровые выходы, output max. 700 mA
Коммуникационные интерфейсыRS232 process port, RS232 service configuration port; 15‑pin male Sub‑D
Защита от проникновенияIP65
Размеры68 × 82 × 28 mm, weight 370 g
Рабочая температура0~+40℃, storage ‑20~+60℃

Приложение

Conveyor line barcode reading, логистическая сортировка, упаковочное оборудование, production-line part identification, warehouse automation. Supports Auto-Config automatic setup, external trigger reading, multi-code reading (до 63 codes).

Интерфейсы & Аксессуары

15-pin male Sub-D connector; matching cable: KD BCL 2. MA30/MA31 modules extend Leuze multiNet-plus RS485 bus networking.

Замена / Совместимые модели

  1. BCL22-SM312 (identical original part)
  2. BCL22-SN312: N-variant, 800 scans/s, identical optics
  3. Upgrade alternative: BCL348i SM 100 (new-generation, supports RS232/422/485 and Ethernet)

Common Fault Points & Used-Unit Inspection Checklist

  1. Polygon mirror motor aging: аномальный шум, intermittent decode failures, stationary laser scan line
  2. Oxidation or broken wires at 15-pin Sub-D connector
  3. Scratched laser window leading to unstable decoding
  4. Damaged I/O output channels caused by over-current

Примечание: This device is manufactured by Leuze. Lenze is a drives brand; the two are frequently confused.

BCL22S-M312 (Лозунг) 15-Pin Male Sub-D Pinout

Device side: 15-pin male Sub-D. MA2 / MA4 connection modules are strongly recommended; direct crimping of Sub-D plugs is not advised. Power supply DC10-30 V; I/O is PNP output, inputs active-high.

ПриколотьСигналОписание
1SW‑IN1Digital Input 1: external scan trigger
2SW‑IN2Digital Input 2: auxiliary function (reset / barcode gate)
3SW‑OUT2Switch Output 2: decode success / status signal
4SW‑OUT1Switch Output 1: barcode read valid signal
5GND_SAI/O output ground
6VDD_INMain power positive DC10‑30 V
7GND_INMain power 0 V reference
8ЧПЗащитная земля; must connect to chassis ground for noise immunity
9RXD‑PROProcess‑port RS232‑RXD (scanner receive)
10TXD‑PROProcess‑port RS232‑TXD (scanner transmit barcode data)
11Сдержанный, do not connect
12Сдержанный, do not connect
13Сдержанный, do not connect
14Сдержанный, do not connect
15Сдержанный, do not connect

Примечания по проводке

  1. Коммуникация: Barcode data uses pins 9/10 RS232 process port. The 9-pin service configuration port resides on the MA wiring module and is not present on the 15-pin connector.
  2. Trigger Mode: Apply 24 V high level to SW-IN1 for one-shot trigger; 0 V stops scanning.
  3. Выходы: SW-OUT1 / 2 are PNP, output voltage equals supply VDD_IN, Макс. 700 mA. When connecting to PLC inputs, tie PLC common terminal to 0 V.
  4. MA2 / MA4 original modules are highly recommended. Home-brewed 15-Sub-D cables frequently cause communication instability and noise-related data loss.
  5. Always connect PE protective earth. Un-grounded units on conveyor systems suffer garbled data and false triggering.

Matching Cable Part-Numbers

KD BCL2: Standard cable with power, I/O and RS232 signals, typical lengths 3 m / 5 m; Order No. 50036410.

MA30 / MA31: MultiNet-Plus bus modules for RS485 multi-scanner networking.

Direct Replacement Comparison

BCL22S-M312: single-line laser scanner, 1000 scans/s, reading range 50-260 mm, barcode module 0.2-0.8 mm, RS232, 2-в / 2-вне, IP65, for high-speed conveyor-line 1D barcode acquisition.

Imported Upgrade Replacements (project-level drop-in compatible, configuration reuse)

  1. BCL348i SM 100

Optical range 50-280 mm, 1000 Hz scan rate; adds TCP-IP Ethernet while retaining RS232, 2-в / 2-out I/O. Preferred upgrade for BCL22 series retrofits; Order No. 50124782.

Примечание: mounting hole pattern differs; custom adapter bracket required.

  1. BCL22-SM312: Exact original spare-part replacement, Order No. 50032097.

Domestic Alternative Scanners (for production-line retrofits)

Domestic ModelКлючевые характеристикиПримечания
Newland NLS‑FS500‑1DSingle‑line laser, 50‑300 mm, 1000 scans/s; RS232, 2IN/2OUT; IP65Conveyor‑line 1D reading; output format can emulate Leuze protocol, экономически эффективный
Hikrobot MV‑ID2000‑LSingle‑line laser, large depth‑of‑field; RS232/Ethernet configurable I/OFor new projects requiring direct MES Ethernet upload

Примечание: Domestic alternatives have different mechanical mounting dimensions. Serial protocol frames require commissioning; true plug-and-play is not possible. For legacy production-line spare-parts, prefer the BCL348i SM100.

Practical Used-Unit Test Procedure for BCL22

  1. Power-on and listen to polygon motor: steady low hum is normal. Rattling, jitter or stationary scan line indicates motor failure; repair costs are high, avoid purchasing such units.
  2. Inspect laser window for scratches or haze; scratches cause partial-field decode failures.
  3. I/O test: apply 24 V trigger to IN1; OUT1 must assert 24 V upon successful decode. Absent output indicates burnt output transistor.
  4. RS232 loop-back test by shorting TXD/RXD. Verify no broken conductors or bent / oxidized pins inside the 15-pin connector.
  5. Barcode read test using 0.3-0.5 mm module barcode across full 50-260 mm working range. Frequent failures at nearor far-range indicate degraded optics.

BCL22S-M312 Scan Frequency

1000 scans per second (1000 scans/s)

M = high-speed variant: 1000 Гц

Sibling N-variant (BCL22S-N312): 800 scans/s

Дополнительный: Polygon-mirror single-line laser delivers 1000 scan lines per second, suited for high-speed conveyor lines.

Optical version 312: reading range 50-260 mm, barcode module 0.2-0.8 mm.

BCL22S-M312 ↔ S7-200 SMART RS232 Wiring

⚠️ The native S7-200 SMART port is RS485 and cannot connect directly to RS232 scanner. SB CM01 signal board is mandatory, configured for RS232 mode, using Free-Port communication to receive barcode strings.

For BCL22 15-Sub-D male connector: MA2 / MA4 wiring modules are strongly recommended; avoid direct soldering to Sub-D plugs.

Hardware Cross-Wiring (3-wire RS232, no hardware handshaking)

BCL22 (15‑Pin Sub‑D) ПриколотьSignal DescriptionSB‑CM01 Terminal
Pin10 TXD‑PRO (Scanner Transmit)Barcode data output from scannerTerminal 4 RxA (PLC Receive)
Pin9 RXD‑PRO (Scanner Receive)Commands sent to scannerTerminal 1 TxB (PLC Transmit)
Pin7 GND_IN (Power Ground)RS232 signal reference groundTerminal 3 M (PLC logic ground)

Rule of thumb: Scanner TX connects to PLC RX; scanner RX connects to PLC TX; common ground is mandatory. Missing ground leads to garbled characters and dropped data.

Власть & I/O Wiring (external-trigger mode, typical factory setup)

BCL22 power supply:

Pin6 VDD_IN: DC24 V positive

Pin7 GND_IN: 24 V return / 0 В

Pin8 PE: protective earth, connect chassis to ground for noise suppression

External scan trigger:

SW-IN1 (Контакт 1): driven by PLC digital output; 24 V high-level triggers scan, 0 V stops.

SW-OUT1 (Контакт 3): PNP output asserts 24 V on successful decode; wired to PLC digital input.

SB-CM01 System-Block Configuration (Micro/WIN SMART)

  1. System Block → SB CM01, communication mode select: RS232
  2. BCL22 factory-default serial parameters:

Скорость передачи данных: 9600

Data bits: 8, Stop bits: 1, Паритет: None

  1. PLC Port 1 (SB-CM01) set to Free-Port mode; SMB130 = 1600 (9600, 8-N-1 Free-Port).

Register note: SB-CM01 maps to Port 1. Free-Port control byte SMB130. Receive buffer uses SMB134-SMB141. RCV instruction targets Port 1, do not use Port 0 (on-board RS485).

BCL22 Scanner Parameter Setup (Leuze-Config software)

  1. Режим вывода: trigger-based reading; transmit barcode string automatically upon successful decode, suffix CR(0Д) or CR+LF(0D0A).
  2. Disable XON/XOFF software flow-control; disable RTS/CTS hardware handshaking.
  3. Trigger source: rising edge on external IN1 for single-shot scan.
  4. Output format: transmit barcode payload only, no extra protocol headers.

PLC Free-Port Receive Logic

Use RCV instruction; define carriage-return CR (160Д) as message end delimiter.

Upon complete receipt of barcode string, copy buffer contents to VB memory area; re-arm RCV instruction for next acquisition.

Timeout-only termination is discouraged. BCL22 appends CR character to every output string; frame delimiter is far more reliable.

Field Troubleshooting

  1. Garbled characters: missing common ground; baud-rate / parity mismatch; cable shield grounding at both ends.
  2. No data received: TX/RX swapped; download RS232 system-block configuration and power-cycle PLC to activate SB-CM01.
  3. I/O trigger does not start scanning: IN1 needs valid 24 V high level; scanner internal parameter must enable external-trigger mode.
  4. Длина кабеля >15 m: RS232 is unsuitable for long distances. Use MA31 module for MultiNet-Plus RS485 bus extension.

Fall-back without SB-CM01

Native Port 0 is RS485. Fit an active RS232-RS485 converter. RS232 side connects to BCL22; converter RS485 side connects to PLC Port 0 terminals 3 & 8. Configure Port 0 for Free-Port. For industrial environments, SB-CM01 solution is preferred; converters incur higher noise-error risk