Reference distance 100 mm, Measuring range ±35 mm;ПНП-выход;2 m fixedcable version
- Разбивка кода модели
| Сегмент кода | Определение |
| HG‑C | Серия продуктов: CMOS Micro Лазерный датчик смещения |
| 1100 | Reference distance 100 mm, measuring range ±35 mm |
| ‑P | PNP open‑collector output;Model without ‑P = NPN output (HG‑C1100) |
- Электрическое ядро & Механические характеристики
| Элемент | Технические характеристики |
| Reference measuring distance | 100 мм |
| Measuring range | ±35 mm (65~135 mm) |
| Repeatability | 70 μm |
| Linearity | ±0.1 % F.S. |
| Temperature characteristic | 0.03 % F.S./℃ |
| Laser source | Red semiconductor laser, Class 2, 655 nm, max. 1 mW, beam spot φ120 μm(at reference distance) |
| Источник питания | DC 12‑24 V ±10 %, ripple P‑P ≤10 % |
| Current consumption | ≤40 mA @24 V;≤65 mA @12 V |
| Switch output | PNP open‑collector;Макс. source current 50 mA;Light‑ON / Dark‑ON selectable;auto‑recovery short‑circuit protection built‑in |
| Аналоговый выход | Напряжение: 0‑5 V (alarm 5.2 V);Текущий: 4‑20 mA (alarm 0 mA) |
| Время ответа | Переключаемый: 1.5 ms / 5 ms / 10 ms |
| External input | PNP non‑contact input; assignable functions: Zero‑set, Teach, Laser OFF, External trigger |
| Protection rating | IP67 |
| Рабочая температура | ‑10~+45 ℃ (No dew‑condensation or icing allowed);Хранилище:‑20~+60 ℃ |
| Vibration resistance | 10‑55 Hz, 1.5 mm double amplitude on all axes, 2 h;Shock resistance 500 m/s²(50 G), 3 times per axis |
| Cable | 5‑core composite cable, standard 2 m;Макс. total extension length 10 m with ≥0.3 mm² conductors |
| Масса | Approx. 85 g (including cable);Die‑cast aluminum housing, acrylic front cover |
| Сертификаты | CE, UKCA, РоХС, FDA, UL/c‑UL |
- Wiring Definition (PNP Version HGC1100P)
5core cable color assignment:
| Cable Color | Сигнал | Описание |
| Коричневый | +В | DC12‑24 V power positive |
| Синий | 0В | Power ground |
| Черный | Выход управления | PNP switching output |
| Розовый | External Input | PNP external function input (Zero‑set / Teach / Laser OFF / Trigger) |
| Серый | Аналоговый выход | Shared for 0‑5 V voltage & 4‑20 mA current |
| Щит | AGND | Analog ground, connect to PLC analog module ground |
External input valid condition: +4 V~+V;Invalid: 00.6 V or open circuit.
- Intraseries Model Comparison
| Модель | Reference Distance | Диапазон измерения | Repeatability | Выход |
| HG‑C1030‑P | 30 мм | ±5 mm | 10 μm | ПНП |
| HG‑C1050‑P | 50 мм | ±15 mm | 30 μm | ПНП |
| HG‑C1100‑P | 100 мм | ±35 mm | 70 μm | ПНП |
| HG‑C1200‑P | 200 мм | ±80 mm | 200 μm | ПНП |
| HG‑C1400‑P | 400 мм | ±200 mm | 300‑800 μm | ПНП |
- Package Contents & Дополнительные аксессуары
Standard Delivery
- HGC1100P sensor main unit (integrated 2 m cable) ×1
- Hardcopy instruction manual ×1
Nonstandard, order separately
MSHG01 stainlesssteel mounting bracket (for M3 screws)
M3 mounting screws are NOT supplied with sensor.
- Типичные сценарии применения
- Толщина, stepheight & warpage measurement (plates, PCB, thinfilm materials)
- Robot height closedloop positioning, insertiondepth inspection for actuators
- Remainingmaterial detection for packaging lines, overlap / presence detection
- Part orientation discrimination, Oring/gasket presence verification
- IP67 rated for splashprone production stations (measurement failure occurs if lens dewcondensates)
- Примечания к выбору & Запрещенные операции
- ✘ Do NOT let target object go outside 65135 mm measuring range, insufficientlight alarm will trigger and analog output will switch to alarm level.
- ✘ Do NOT scratch acrylic front cover; NO organic solvent cleaning. Only clean with lintfree soft cloth.
- ✘ Strictly avoid dewcondensation and icing. IP67 does NOT prevent internal condensation which directly causes measurement error.
- ✘ Route sensor cables separately from highpower cables to avoid measurement drift; singleend grounding for analog shielded cable is recommended.
- ✘ Specularreflective or highlytransparent workpieces produce abnormal readings; matte diffusereflective targets yield optimal performance.
- ✘ Laser Class 2: Never stare directly into laser beam spot.
- ✘ Extended cables must be ≥0.3 mm² crosssection; total cable length shall not exceed 10 m.
- Troubleshooting Table
| Симптом неисправности | Possible Root Cause | Корректирующие действия |
| Insufficient‑light alarm | Target out‑of‑range, misalignment, low target reflectivity | Ensure target stays within 65‑135 mm; adjust mounting angle; improve target reflectance |
| Output short‑circuit alarm | Load short‑circuit on output channel | Выключить питание, inspect wiring and load; sensor auto‑resets after fault removal |
| Laser hardware failure | Laser diode damage | Contact manufacturer for repair; no on‑site fix available |
| EEPROM abnormality | Internal memory corruption | Contact manufacturer for repair |
| Zero‑set failure | Target out‑of‑measuring‑range or offset mode active | Place target within valid range; exit Offset mode |
- Crossmodel Compatibility & Справочник по замене
- Панасоник intraseries NPN alternative: HGC1100 (only output polarity differs; all other specs identical)
- Thirdparty alternatives: Keyence IL065; Omron ZX2LD100. Evaluate beam spot, repeatability and analogoutput wiring before retrofitting.
Crossbrand Model Comparison for Panasonic HGC1100P
Reference baseline specs: Reference distance 100 mm, measuring range ±35 mm (65135 мм), repeatability 70 μm, PNP switching output + 05 V /420 mA analog output, IP67, 1.5/5/10 ms switchable response time, Class 2 red laser, integrated body with local display & keys.
⚠️ No dropin 100pin / footprint compatible replacement. Retuning wiring, PLC scaling and mounting bracket are mandatory for any crossbrand swap.
Imported Brand Comparison Table
| Бренд | Reference Model | Repeatability | Выход | Ключевые различия | Replacement Evaluation |
| Панасоник | HG‑C1100‑P | 70 μm | ПНП;0‑5V/4‑20 mA;External Input;Local display & keys | Baseline reference unit | Reference model |
| Кейенс | IL‑100 | 40 μm | ПНП/НПН;0‑5V/4‑20 mA; IO‑Link;Local display | Narrower measuring range ±30, different housing dimension, Class 1 laser, smaller spot, более высокая стоимость | Performance‑oriented alternative; watch range boundary limits |
| Омрон | ZX2‑LD100 + ZX2‑LDA41 amplifier | 50 μm | Requires separate amplifier unit; аналоговый + switch output | Split‑head & amplifier system, NOT all‑in‑one unit, completely different cabling layout | Major modification workload; cannot reuse existing integrated‑sensor installation space |
| БОЛЬНОЙ | OD2‑100T1 | 80 μm | ПНП;0‑10V/4‑20 mA;IO‑Link | Analog voltage output 0‑10 V (not 0‑5 V), PLC scaling logic must be rewritten, different housing size | Identical measuring range; PLC program modification required |
Domestic Allinone Alternatives (Fixedcable, ПНП + dual analog outputs, local digital display)
| Бренд | Reference Model | Reference Distance | Ключевые различия | Replacement Evaluation |
| Atonm(Atom) | LD1‑H100‑P | 100 мм | Very close parameters; mounting hole pattern differs; температура. drift 0.03 %F.S./℃; Class 2 laser | Preferred domestic retrofit option. Measuring range fully matched; only mounting bracket needs rework |
| Lanbao | PDE‑CR100TGIU‑P | 100 мм | Additional RS485 digital interface; different housing; spot φ120 μm, Class 2 laser | Suitable for applications requiring digital data upload |
Panasonic OEM Internal Replacements
- HGC1100: NPNoutput variant, optical / диапазон / mechanical dimensions unchanged. Only output polarity differs; PLC wiring must be adjusted.
- HGC1100L3PJ: M12connector version (replaces fixed 2 m cable), IOLink supported, identical optical specs. Requires M12type cable assembly.
⚠️ Critical Replacement Risk Reminders
- Measuringrange boundary difference: Keyence IL100 works 75130 mm, narrower than HGC1100P 65135 mm. If original process uses the 6575 mm nearend zone, IL100 will trigger insufficientlight alarms and is not directly applicable.
- Analog voltage mismatch: SICK OD2100T1 outputs 010 V while Panasonic outputs 05 V. PLC analog channel scaling formulas must be rewritten.
- Splitsystem trap: Omron ZX2LD100 is only a sensor head; amplifier ZX2LDA41 is mandatory. Extra cabinet space is needed; high retrofitting overhead.
- Mechanical mounting: All thirdparty competitors have different housing outlines and M3 mounting hole layouts. Original mounting bracket MSHG01 cannot be reused; new bracket / machining required.
- Externalinput logic: Valid PNP input voltage thresholds vary across brands. Reverify zeroset / teach / trigger signal levels against target datasheet after replacement.
✅ Quick Selection Guidelines
- Minimalmodification, keep original scaling logic: Atonm LD1H100P, full 65135 mm range match, dual 05 V /420 mA analog outputs.
- Higher stability, sufficient budget: Keyence IL100, respect minimum measurable distance 75 mm constraint.
- IOLink communication required: SICK OD2100T1, be sure to rewrite PLC scaling code.
- Избегать: Omron ZX2 series, high modification workload for splitamplifier architecture.
Application Scenarios — Panasonic HGC1100P Laser Displacement Sensor
Core specs recap: Reference distance 100 mm, measuring range 65135 mm (±35 mm), repeatability 70 μm, PNP switching +05 V/420 mA analog outputs, IP67, Class 2 red laser. Optimized for distance, высота, stepheight and warpage measurement on diffusereflective targets. Not suitable for specularreflective or highly transparent objects.
📦 Packaging & Логистическая отрасль
- Remainingroll diameter detection: Monitor residual thickness of film / adhesivetape rolls; trigger rollchange alert at lowresidual threshold.
- Packagingarticle height inspection: Verify stack height of cartons / bags; detect missing parts, shortheight or overfilled packages.
- Sealingtape presence & warpage inspection: Detect tape lifting / missing tape; identify warped package edges.
- Materiallevel height detection: Measure material height inside magazine / bin for lowmaterial / fullbin judgement.
🔧 Automotive Component Manufacturing
- Gasket / Oring assembly verification: Judge proper seating, missing installation or protrusion via height difference measurement.
- Stampedpart stepheight & flatwarpage inspection: Evaluate flatness and step height of sheetmetal stampings; identify deformation or missing material.
- Injectionmold gateresidue height inspection: Judge whether gate residual height is outoftolerance for NG rejection.
- Fixture workpiecepresence check: Verify insertion depth; detect misplaced or reversed parts.
📜 Electronics & PCB Industry
- PCB board warpage measurement: Quantify circuitboard bending deformation for outoftolerance judgement.
- Gasket / contactspring height inspection: Measure compressed height of connector springs; detect damaged or missing springs.
- Indirect thinfilm thickness measurement: Dualsensor opposedsetup for filmthickness measurement; singlesensor measures surfaceheight variation over base substrate.
⚠️ Direct measurement on transparent thinfilm causes signal loss; use diffusereflective backing plate.
🤖 Robotics & Общая автоматизация
- Robot height positioning: Heightranging before robot grasping for closedloop height compensation.
- Toolingfixture height verification: Inspect locatingsurface height of production fixtures to identify fixture wear.
- Assembly pressfit depth monitoring: Realtime monitoring of component insertion / pressin depth; alarm for pressfit defects.
🏭 Generalpurpose Machining
- Plate height / offset detection: Measure height of aluminum / plastic plates; detect offset or lifting.
- Rollgap monitoring: Track rollergap variation to detect roller wear.
- Workpiecethickness differential sorting: Detect height difference across batches to perform OK / NG part sorting.
💧 Splashprone Working Conditions (IP67)
Applicable for stations with occasional water splashes. Lens dewcondensation / icing is strictly forbidden. Condensed water vapor directly induces measurement drift and failure.
❌ Nonapplicable Scenarios (Selection Pitfalls)
- Specularhighreflectivity workpieces: Strong specular reflection bounces laser directly back to sensor → unstable jumping readings.
- Fully transparent / hightransmittance workpieces (стекло, clear PET): Laser passes through target, no usable return light.
- Continuous dewcondensation / icing environment: IP67 rating cannot resist internal condensation.
- Working distance persistently outside 65135 mm: Insufficientlight alarm is triggered.
Output Usage Notes
Overheight / underheight limit alarm: Use PNP switching output with configurable threshold.
Continuous value transmission to PLC: Adopt 05 V voltage or 420 mA analog output for distance scaling conversion.
Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи