Феникс Контакт ELR1-24DC-600AC-30, Номер заказа. 2297154 Complete Model Decoding Model: ELR1-24DC-600AC-30 ELR1: Series → ELR1 single-phase 1 single-phase electronic load relay (solid-state contactor, contactless switch, suitable for motor loads) 24округ Колумбия: Control side supply / drive voltage: 24 V DC 600AC: Rated operating voltage of main circuit: AC 0…600 V 30: Rated continuous operating current: 30 ...

  • Подробная информация о продукте

Феникс Контакт ELR1-24DC-600AC-30, Номер заказа. 2297154

  1. Complete Model Decoding

Модель: ELR1-24DC-600AC-30

  1. ELR1: Series → ELR1 single-phase
  2. 1 single-phase electronic load реле
  3. (solid-state contactor, contactless switch, suitable for motor loads)
  4. 24округ Колумбия: Control side supply / drive voltage: 24 В Вашингтоне
  5. 600переменного тока: Rated operating voltage of main circuit: AC 0…600 V
  6. 30: Rated continuous operating current: 30 А
  7. 2297154: Official unique Финикс Contact order number

Полное название продукта: ELR 1-24DC/600AC-30 Solid-State Contactor

  1. Основные электрические параметры
ЭлементСпецификация
Номер заказа.2297154
Управляющее напряжение24 В Вашингтоне (permissible range: 19.2~30 V DC)
Напряжение главной цепиAC 0~600 V, 50/60 Гц
Rated Load Current30 А (резистивная нагрузка)
Applicable Load TypeSingle-phase AC loads; фанаты, нагревательные элементы, small single-phase motors
Switching ComponentBidirectional triac (бесконтактный)
Частота переключенияMuch higher than mechanical contactors, suitable for frequent switching
ИзоляцияOptoelectronic isolation; galvanic isolation between control circuit and main circuit
Тип монтажа35 мм Монтаж на DIN-рейку
СвязьScrew terminal connection
Ambient Operating Temperature-20 ℃ ~ +60 ℃ (требуется снижение мощности выше 40 ℃)
  1. Ключевые особенности

✅ No mechanical contacts, no electric arcs, низкий уровень шума, увеличенный срок службы, ideal for frequent start-stop operation

✅ Built-in overvoltage absorption circuit to suppress inductive load surge

⚠️ Important Restriction: Single-phase solid-state relay. Not for direct control of three-phase loads; only applicable to single-phase AC loads

⚠️ For inductive loads (моторы, катушки), sufficient current margin is required; 30% current derating is recommended

  1. Приколоть / Определение терминала

А1 / А2: Control terminals for 24 В Вашингтоне

А1(+), А2(-)

л / Н: AC input terminals of main circuit

ВНЕ: Load output terminal

  1. Типичные сценарии применения

Control of electric heaters inside industrial control cabinets

Frequent start-stop of single-phase fans and conveyor motors

Temperature control loops for packaging machinery, test equipment and ovens

AC loads requiring low-noise, maintenance-free switching

  1. Альтернатива & Same-Series References
  2. Lower-current variants in the same series: ELR1-24DC-600AC-10 (10 А), ELR1-24DC-600AC-20 (20 А)
  3. For three-phase solid-state switches: Refer to ELR3 series (three-phase solid-state contactors)
  4. Competitor equivalents: Schneider SSP series, Omron G3PA single-phase solid-state relays
  5. Примечания к закупкам

Distinguish model suffixes: Do not confuse ELR1 (однофазный) / ELR3 (трехфазный)

Use order number 2297154 strictly to avoid delivery of other current ratings

Solid-state components generate significant heat; sufficient clearance for heat dissipation is required for dense installation inside cabinets

Application Scenarios — Phoenix Contact ELR 1-24DC/600AC-30 (Order No.2297154)

Product Overview Recap

Single-phase solid-state contactor (contactless SSR)

Контроль: 24 В Вашингтоне; Главная цепь: ≤600 V AC, рейтинг 30 А; DIN rail mounted; optoelectronic isolation; bidirectional triac output; optimized for frequent switching of single-phase AC loads

Основные преимущества: Arc-free, no mechanical wear, низкий уровень шума, high-speed frequent switching. Ограничение: Self-heating, current derating mandatory for inductive loads.

Critical Premise: Only supports single-phase AC loads; cannot directly drive three-phase motors

  1. General Standard Industrial Scenarios

1.1 Resistive Heating Loads (Most Common Application)

  1. Control of heating tubes in ovens, tunnel furnaces and thermal processing equipment
  2. Heating circuits for injection molding and extruder barrels
  3. Industrial thermostats, hot air blowers and duct electric heaters
  4. Heating elements of heat-sealing machines and hot stamping equipment in packaging machines

✅ Advantage: PID high-frequency continuous switching by temperature controllers rapidly wears contacts of mechanical contactors; ELR1 perfectly fits this working condition

1.2 Single-Phase Fans & Насосы (Inductive Loads)

Application requirement: 25%~30% current derating for load selection

  1. Control cabinet cooling fans, industrial exhaust fans and ducted single-phase fans
  2. Small single-phase centrifugal pumps, circulating water pumps and fume exhaust fans
  3. Air supply units for drying equipment

⚠️ Note: Large inrush current upon motor startup; recommended actual load ≤20~22 A for the 30 Модель

1.3 Lighting Loads

  1. High-power halogen lamp banks and infrared heating lamp arrays in workshops
  2. High-power lighting arrays in test laboratories

❌ Not recommended: LED drivers and electronic ballast loads (high inrush current; RC snubber circuit is recommended)

  1. Industry-Specific Field Applications

▶ Packaging Machinery

  1. Heating control for heat shrink tunnels
  2. Actuation of heat-seal bars on vertical / horizontal packaging machines
  3. Single-phase drive motors on conveying lines and hot air drying systems

▶ Plastics & Rubber Machinery

  1. Heating rod control for each temperature zone of extruders and pelletizers
  2. Start-stop control of heating circuits for mold temperature controllers

▶ HVAC & Environmental Test Equipment

  1. Heaters for high-low temperature test chambers and constant temperature & humidity chambers
  2. Hot air circulation systems for purification equipment
  3. Heating modules of industrial dehumidifiers

▶ New Energy & Lithium Battery Production Lines

  1. Heating control for electrode drying ovens
  2. Hot air devices for dust removal equipment

Преимущество: No sparks for dust-free workshops (the device itself is NOT explosion-proof; explosion-proof enclosure is mandatory for hazardous areas)

▶ Food & Фармацевтическое оборудование

  1. Electric heating systems for food baking lines and sterilization equipment
  2. Hot air drying units for cleaning equipment

Преимущество: Contactless operation prevents metallic dust generation, meeting operation requirements for cleanrooms

▶ Automated Test Equipment

  1. Switching of high-power loads on aging test benches
  2. Adjustable AC load switching devices in laboratories
  3. Cluster control of high-power AC solenoid coils
  4. Неприменимые сценарии (Selection Red Lines)
  5. ❌ Direct control of three-phase asynchronous motors (ELR1 is single-phase SSR; only controls one phase. Strictly prohibited as main three-phase switch. Select ELR3 series for three-phase loads)
  6. ❌ Frequent startup of high-power single-phase compressors (severe startup inrush current may cause triac breakdown)
  7. ❌ Applications relying on the device for long-term overload & защита от короткого замыкания (solid-state relays have poor short-circuit withstand capability; автоматические выключатели / fuses must be installed upstream)
  8. ❌ Unprotected outdoor open-air installation (must be fitted inside control cabinets)
  9. ❌ High-frequency high-voltage inductive loads without RC snubber circuits
  10. Recommended Supporting Configuration for On-Site Deployment
  11. Индуктивные нагрузки (моторы, катушки): Parallel Phoenix Contact RC absorption modules to suppress back EMF
  12. Multiple units mounted side-by-side on DIN rail: Maintain minimum clearance ≥10 mm between adjacent devices; current derating required when cabinet ambient temperature>45 ℃
  13. Upstream protection: Deploy gG fuses; circuit breakers alone cannot provide reliable short-circuit protection
  14. Preferred component for PID temperature control systems; switching frequency can reach several cycles per second, service life far exceeding mechanical contactors

Mounting Specification — Phoenix Contact ELR 1-24DC/600AC-30 (2297154)

  1. Standard Mounting Form

Standard mounting: Snap-on installation on 35 мм DIN-рейка (TH35-7.5)

  1. Integrated DIN rail locking clip on device rear side; no additional brackets required
  2. Mandatory mounting orientation: Вертикальная установка (terminals facing up/down; cooling fins arranged vertically)

❌ Horizontal side mounting & inverted installation are forbidden! Horizontal placement blocks natural convection cooling, leading to overheating shutdown and triac damage.

  1. Монтаж & Dismantling Procedures
  2. Hook the upper clip onto the DIN rail;
  3. Press down the main body until an audible “щелкнуть” confirms the lower clip locks onto the rail;
  4. Removal: Pry open the bottom clip with a flat screwdriver and lift the device upwards.
  5. Thermal Clearance Requirements (Критический! 30 A solid-state contactors generate considerable heat)

Single Independent Installation

Vertical clearance (top & bottom): ≥50 mm ventilation space

Lateral clearance: ≥10 mm if adjacent space is vacant

Multiple Units Mounted Side-by-Side on the Same DIN Rail

Minimum clearance between adjacent devices: ≥10 mm

Zero-clearance tight arrangement is prohibited

Maintain ≥15 mm clearance if cabinet temperature>40 ℃

For large-scale continuous installation, forced air cooling via cabinet axial fans is recommended

  1. Спецификация проводки (Screw Terminals)

Terminal Assignment

А1(+), А2(-): 24 V DC control circuit

л, ВНЕ: Main circuit for single-phase AC loads

Wiring Parameters

  1. Тип терминала: Anti-loosening screw terminals
  2. Applicable conductors:

Solid single-core wire: 0.5~10 mm²

Stranded flexible wire: Crimp lugs are recommended

  1. Recommended tightening torque: 1.2~1.5 N·m

⚠️ Insufficient torque → excessive heating; excessive torque → thread slipping or terminal base cracking.

Wiring Layout Suggestion

Separate routing for control cables (А1/А2) and high-power cables (L/OUT) для уменьшения электромагнитных помех

Minimize length of power wiring to reduce voltage drop and heat generation

  1. Ambient Operating Boundary Conditions
  2. Место установки: Inside control cabinets, Класс защиты IP20

❌ Direct exposure to open air; avoid dust, moisture and condensation contacting the device

  1. Permissible operating temperature: -20 ℃ ~ +60 ℃

Current derating is mandatory when ambient temperature>40 ℃

  1. Avoid these installation positions:

Directly above transformers, power resistors and other heat-generating components

Poorly ventilated dead zones inside cabinets

Locations with persistent strong vibration (continuous vibration loosens terminal screws)

  1. Optional Heat Dissipation Accessories

For continuous full-load operation in enclosed cabinets, DIN rail-mounted aluminum heat sinks can be attached to the rear of the device to reduce housing temperature.

No heat sink supplied as standard; cooling relies on integrated housing fins for natural convection.

  1. Strictly Prohibited Operations
  2. Do not suspend the device by cables; all mechanical load shall be supported by the DIN rail
  3. Do not block cooling fins on sides and rear surface
  4. Do not connect multiple ELR1 units in parallel for current sharing (inconsistent on-resistance causes uneven current distribution and burnout)
  5. Do not install contactors / circuit breakers tightly adjacent to solid-state contactors without heat clearance

Standard Description for Engineering Drawings

The ELR1-24DC/600AC-30 shall be vertically mounted on TH35 standard DIN rail. Lateral clearance between adjacent devices ≥10 mm. Separate routing for control and power circuits. Момент затяжки клемм: 1.2~1.5 N·m. Ensure adequate natural ventilation for heat dissipation.

 